the Cooper
B-Line Cable Tray
catalog data (SDL, HDL and HPL
Series) in PDMS Design (V11.6 & 12.x):
A.) Example PDMS Design / Usage with the Original (old) AVEVA Cable Tray
Function
And set up the geometric attributes / position of Head and Tail of branch
A.1) Automatic Filling with FixLength Tubes (only available in old Cable Tray
Function)
This function gives you the possibility to conmcentrate on the Fitting placement
only, the handling of the Fixlength tube items (between all fittings, and between
Head and first fitting or the last fitting and the tail) can be managed later after
the routing of cabletrays is finished.
If a re-Routing of an already filled Cable Tray is necessary, there is also an Un-fill
function with deletes al the fixlenth tube items and after finishing re-routing the
items can be set again, easily.
1.) Fill Complete Branch with Fixlength Tube items
a.) Routed Cable tray without fixlength tube items
Set the branch (to be filled with Fixlength Tube items) as the current active
element and choose Fill Branch and apply with OK
Complete Branch should be filled with Fixlenth Tube items (between all fittings,
and between Head and first fitting abd between the last fitting and the tail of
branch)
b.) Set the branch (to be filled with Fixlength Tube items) as the current active
element and choose Un-Fill Branch and apply with OK
For the Complete Branch all Fixlenth Tube items should be deleted again
B.) Example PDMS Design / Usage with the Original (new) AVEVA Piping Function
(Specs are in the System twice with Extension *P indicated for selection in
the Piping Application)
And set up the geometric attributes / position of Branch Head and Tail of a branch
:
Note : Due to an unsolved problem in the Aveva PDMS Software the implied Tubes
are not set up with an ubstruction volume, just all the fittings (including the Fix
Length Tubes)