Você está na página 1de 4

Pile Cap of Footing F1:

fc'(N/mm2) = 21
fy(N/mm2) = 325
Total SL on Column(kN) = 934
Column short dimension(mm) = 300
Column long dimension(mm) = 375
Total number of pile =
Dia of pile(mm) =
Pile c/c Spacing(times dia) =
Edge offset of Cap(mm) =

2
450
4
150

Cap short dimension(mm) = 750


Cap long dimension(mm) = 2325
Av. Load factor = 1.55
Total FL on Column(kN) = 1448
FL on Each Pile(kN) = 724
Depth of Cap(mm) = 950

Column Punching:
Effective Depth of Cap(mm) =
Design Shear Strength(N/mm2) =
Punching area(mm2) =
Concrete Punching Shear(kN) =

770
1.29
1155000
1494
OK

Pile Punching:
Effective Depth of Cap(mm) =
Design Shear Strength(N/mm2) =
Punching area(mm2) =
Concrete Punching Shear(kN) =

770
1.29
577500
747
OK

Flexaral Shear:
Dist. Of CS from CC(mm) =
Dist. Of PC from CC(mm) =
Applied Shear(kN) =
Design Shear Strength(Nmm2) =
Design Shear(kN) =

920
787.5
298
0.65
374
OK

Moment:
Moment(kN-m) = 461

Mu(kN-m) Mu(kN-m)
(ABS)
461.45
461.45

E. depth
(mm)
770

Width
(mm)
750

Mu1
(kN-m)
2343.25

Mu2
(kN-m)
0.00

As(mm2)

As'(mm2)

2120

Temperature reinf.(mm2)= 469


Minimum reinf.(mm2)= 2488
1.33 Times Structural reinf.(mm2)= 2819