Sikalastic 110 - RC flat roof structures.

doc / Page 1 of 2

Method Statement
Sikalastic-110 RC Flat Roof Structures

Product

Sikalastic-110

Description

Sikalastic-110
is
a
water
based
1-part
MMA
modified
Polyurethane/bituminous coating, formulated to form a highly elastic,
seamless and crack bridging membrane.

Tools/Materials

Electric stirrer (approximately 300 400 rpm), hand-held grinder, steel wire
brush, brush roller, clean cloth, Sikalastic-110, etc.

Planning

Prior to starting the work, calculate the total coating areas in m .


2
Consumption is approximately ~1kg/m /mm thick.

Surface Preparation

The concrete substrate must be clean and free from all traces of loose
material, dust, surface contamination such as form oil, curing membranes (if
used), oil, grease, etc.

Weak concrete must be removed and surface defects such as blowholes and
voids must be fully exposed.
The substrate should be well dampened but free of surface water and leaks.
Application

1. The substrate should be well dampened but free of surface water and
leaks.
2. Stir the Sikalastic-110 thoroughly with an electric stirrer until a
homogenous mixture is achieved.
3. Leave the product to settle after stirring to allow entrapped air to escape.
4. Apply first coat of with 1-part of Sikalastic-110 diluted with 3-part of clean
water and apply to the prepared surface by means of roller, brush or
spray.
5. First coat can be applied immediately after the primer.
6. For indoor or inadequately ventilated area, allow 30 minutes between
the primer and the first coat.
7. Leave the whole system to cure for 48 hours at 23 C, 50 % r.h. before
overlaying with screed.

Protection

It is recommended to overlay sikalastic-110 with a protective screed for


additional mechanical protection and to avoid colour changes due to UV
exposure.

Cleaning

Clean all working tools and equipment immediately with water after used.
Once hardened, the material can only be removed mechanically.

This report has been prepared based on Sikas current knowledge and experience of Sikas products when properly stored, handled and applied under normal conditions.
It only applies to the application and product referred to in this report. In case of changes in the parameters of the application, such as changes in substrates etc., or in
case of a different application, consult Sikas Technical Service prior to using Sikas products. The user of the product must test the products suitability for the intended
application and purpose. Consult the current technical data sheet. Except as expressly stated in writing Sikas warranty is governed exclusively by our current sales
conditions. In particular, Sika does not warrant the correct application of its products.
9/2003

Sikalastic 110 - RC flat roof structures.doc / Page 2 of 2

Safety Precautions

Wear gloves and goggles during application. If in contact with skin, wash
thoroughly with soap and water. If in contact with eyes or mucous membrane,
flush immediately with plenty of water and seek medical attention without
delay. Use with adequate ventilation.

_________________________________________________________________________________

Note

For more information, refer to our Chemical Safety Data Sheet (available
upon request).
This is a general method statement and therefore specific conditions of use
cannot be anticipated. It is the specialist applicators responsibility to review
the actual site conditions and specify detailing requirements.