Introduction
Spider
Engineering manual
04-04-02
1.1 Description
The Spider unit is a microcontroller based system, configurable to suit different application
needs. It is designed to match the two or three door power unit also with one door unit added.
The control system can control pumps with double coil (Denison 9A, Brueninghaus EP, Sauer
Sundstrand KA or similar pumps) or single coil in one direction (Denison 5A).
The unit can be mounted inside the power unit, in the power unit door, on the outside of the
power unit or delivered separate with wall brackets or panel flange to be wired in by the
customer. Cable sets can be supplied as an option.
The configuration of the pre-programmed system functions is done using the front panel with
help from the text displays or via a serial connection from a laptop. The configuration mode can
be protected with a password.
The Spider unit can control the system with different settings of electric motor/pump
configuration.
One to four pumps for one drive:
EM
DRIVE
DRIVE
EM
DRIVE
EM
DRIVE
EM
EM
EM
EM
EM
EM
DRIVE
EM
EM
DRIVE
DRIVE
DRIVE
EM
EM
EM
EM
EM
DRIVE
DRIVE
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
1(14)
04-04-02
Two to four pumps for two drives with common function. If one stops by a fault the other will
also stop:
EM
EM
DRIVE
DRIVE
DRIVE
DRIVE
EM
EM
DRIVE
DRIVE
EM
EM
DRIVE
DRIVE
EM
DRIVE
DRIVE
EM
DRIVE
DRIVE
EM
DRIVE
DRIVE
EM
EM
EM
EM
EM
EM
EM
The Monitor function can health monitor the power unit switches and give information on the text
display about warnings or alarms. An alarm will stop the electric motor or motors if the digital
interlock output is connected via a relay to the starter interlock circuit. Up to 4 pumps can be
controlled in parallel for the same drive
M
M
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
2(14)
04-04-02
The Basic function has added functions for power limitation and closed loop speed feedback via
a PID-regulator. Inputs are available for analog or digital speed encoders.
The unit can also monitor analog signals on the display such as speed, E-motor current,
pressure etc.
The Shredder function has the same functions as Basic and added functions for reversing by an
overload-stopped drive. It is possible to maximise the number of reversals within a time limit and
stop the drive when exceeded. The drive can be set to change direction after an adjustable time
interval.
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
3(14)
04-04-02
The Friction function has the same functions as Basic and added functions for control of two
hydraulic drives driven together with a ratio between the motors.
The Friction slave function has the same functions as Basic and added functions for control of
two hydraulic drives driven together with a ratio in relation to the master setpoint.
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
4(14)
04-04-02
The Synchro function has the same functions as Basic and added functions for position control
between two hydraulic drives. It is possible by an external signal to set the angle between the
rolls. Ratio drive is also possible. This mode requires digital speed encoders.
The Spider unit front has push-buttons for start and stop of the drive, local/remote, speed
setpoint by increase and decrease in local mode, inch reverse, regulated/non-regulated drive
and auto/manual drive in shredder mode. These push-button functions can be bypassed in the
configuration of the system functions.
All inputs and outputs are configurable and can be connected to pre-programmed functions in
the setup of the system. All signals are as standard wired to contact terminals or via fieldbus port
(optional).
The digital inputs can be configured to functions for eg. start/stop, reverse, reset, monitoring of
the power unit, auxiliary monitor where it is possible to set the function and display monitor text.
The digital outputs can be configured to functions for eg. common alarm/warning, ready to use,
drive started, shredder blocked, cooler and heater control. The outputs are of dry relay contact
type.
The analog inputs can be configured to functions for eg. tank temp, speed, pressure, power for
monitoring and control. The inputs can be configured for current loop or voltage.
The analog outputs can be configured to monitor eg. speed, pressure, temp. The outputs can be
configured for current loop or voltage.
The system includes a drive monitoring function with drive time counters, alarm/warning list and
8 scalable log channels with data download via serial interface. A remote drive monitoring
system with access via GSM can be added as an option.
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
5(14)
04-04-02
E01P x x x - xxxx
Article group for Spider
Serial number
Function:
Drive 2 config:
M= Monitor function
0= No Emotor, No pump
1= 1 Emotor - 1 Pump
2= 1 Emotor - 2 Pumps
3= 2 Emotors - 2 Pumps
4= 2 Emotors - 3 Pumps
5= 2 Emotors - 4 Pumps
6= 3 Emotors - 3 Pumps
7= 3 Emotors - 4 Pumps
8= Emotor common w.drive 1 - Tandem pump1
9= Emotor common w.drive 1 - Tandem pump2
B = Basic function
S = Shredder function
Z = Synchro function
F = Friction function
R = MRC function
Drive 1 config:
1= 1 Emotor - 1 Pump
2= 1 Emotor - 2 Pumps
3= 2 Emotors - 2 Pumps
4= 2 Emotors - 3 Pumps
5= 2 Emotors - 4 Pumps
6= 3 Emotors - 3 Pumps
7= 3 Emotors - 4 Pumps
8= 1Emotor - Tandem pump 1
9= 1Emotor - Tandem pump 2
2011 0347
Individual number
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
6(14)
04-04-02
7(14)
04-04-02
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
8(14)
04-04-02
-Bug in swashangle feedback could stop the PWM output for drive 2.
-Interrupt disable time shortened down.
-Encoder interrupt time reduced to give better performance with two
5000ppr pulse encoders.
-Error in reading of REG 106 and REG206 could cause watchdog problem.
-Counters reduced to one turn in synchro-counter mode.
9(14)
04-04-02
Error too large warning not possible for slave in Synchro mode
Version 3.0.1
Ready 00-05-30
Bug fixes:
MAN/AUT indication failed at shredder blocked when using digital input for
MAN/AUT switching
Version 3.0.2
Ready 00-08-16
Bug fixes:
Error time in ERROR TOO LARGE function accumulates with too short drop-out
time as a result.
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
10(14)
04-04-02
Version 3.0.3
Ready 00-10-05
Error function in ERROR TOO LARGE function bypassed when speed signal is higher then setpoint
signal if parameter C(I)11 is set to 100%.
Version 3.1.0
Ready 00-12-06
Version 3.1.1
Ready 01-09-27
Bug fixes:
Parallel functions for power limitation not possible with two pumps driving one
motor in Shredder drive mode.
Version 3.2.0
Ready 01-12-03
Version 4.0.0
Ready 03-06-19
Version 4.0.1
Ready 03-09-10
Bug fixes:
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
11(14)
04-04-02
276 0004
Prototype during first time of developement of the system.
276 0004 rev.A
Layout ready 96-07-26
Card no. 11-57
New amplifiers for the PWM output.
Pull-down resistors for keypads.
Inputs for swashangle feeedback.
100 msec filter for the analog inputs.
Normally closed inputs for external stop buttons.
276 0004 rev.B
Card no. 58-271, 273-281, 355-360, 442-444
Layout ready 97-04-18
Pull-up and pull-down resistors for the serial communication port.
Two positions on input selection jumper (voltage/current) for analogue inputs.
Smaller changes to avoid jumpers on the backside of the card caused by missing connections in
rev.A version.
276 0004 rev.C
Card no. 272, 282-290
Layout ready 98-07-01
Relays on digital outputs.
Fuses for PWM outputs.
Separate memory card for configurated parameters and Real Time Clock.
Connections for front panel membrane switches.
245V supply jumper.
Changed circuit for swashangle feedback.
276 0004 rev.D
Layout ready 98-10-05
Card no. 291-354, 361-370, 446
Smaller changes to avoid jumpers on the backside of the card caused by short circuit in rev.C
version.
Layout ready 98-02-16
Card no. 371-441, 445, 447-453, 502-521
Smaller changes to simplify mounting of terminals.
276 0004 rev.E
Layout ready 99-06-05
Card no. 454-501, 522-573
Indication for supply to stroker output amplifiers.
Test pins for supply voltages and current feedback.
276 0004 rev.F
Layout ready 00-02-24
Card no. 574 Connection for analogue output card.
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
12(14)
04-04-02
276 0020
Prototype during first time of developement of updated Spider .
Card no. 2001-2005
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
13(14)
04-04-02
Power supply
M
B
0
1
2
S
Z
F
R
Drive 1 config.
No Emotor - No pump
1 Emotor - 1 pump
1 Emotor - 2 pumps
2 Emotors - 2 pumps
2 Emotors - 3 pumps
2 Emotors - 4 pumps
3 Emotors - 3 pumps
3 Emotors - 4 pumps
1 Emotor - Tandem pump 1
1 Emotor - Tandem pump 2
Pressure control
0
1
2
3
4
5
6
7
8
9
0
1
2
3
RMS
0
1
2
Drive 2 config.
No Emotor - No pump
(Single)
1 Emotor - 1 pump
1 Emotor - 2 pumps
2 Emotors - 2 pumps
2 Emotors - 3 pumps
2 Emotors - 4 pumps
3 Emotors - 3 pumps
3 Emotors - 4 pumps
Emotor common w. drive1- Tandem pump1
Emotor common w. drive1- Tandem pump2
0
1
2
3
4
5
6
7
8
9
Monitor [M]:
Basic
[B]:
Shredder [S]:
Synchro [Z]:
Friction [F]:
None
With antenna on Spider box
With antenna on Power unit
Fieldbus card
0
1
2
3
Mounting
None
Profibus
Not decided
Not decided
Heater
*)
*)
*)
*)
*)
Not used
Drive 1
Drive 2
Both drives
1
2
3
4
5
6
7
0
1
None
Installed in Spider box
Display
0
1
LCD (Standard)
VFD (Required for Chinese characters)
The contents of this information are subject to change without notice or obligation. Information herein should be confirmed before placing orders.
14(14)