Você está na página 1de 12

NOZZLE

N1

NOZZLE TYPE

WN, R

SIZE
SERVICE
NO.

8" SCH 80
Rich solvent feed

DESCRIPTION

SYMBOL

Max. allowable stress value


of nozzle
Max. Allow. stress value of
Shell or Head
Max. allowable stress value
of reinf. Pad

Sn
SV

Internal Design Pressure

Pi

Design temperature

Td

Inside diameter of Shell or


Head skirt

Inside radius of shell

Nominal Thickness of Vessel

tnom-vessel

1
2
3

9
10

Nominal thickness of vessel


(Less. Cor. Allowance)
Ratio of major axis to minor
axis of ellipsoidal head

Sp

t
D/2h

11

Factor for ellipsoidal head

K1

12

Shell thickness required

tr

13

Joint efficiency of Shell or


Head

14

Outside diameter of Nozzle

Do

15

Act. thickness of nozzle


(nom. thickness)

tact

16

Inside radius of nozzle

rn

17

Inside diameter of nozzle

18

Length of nozzle neck

19

Joint efficiency of Nozzle

En

20

Joint efficiency

E1

21

Corrosion allowance

CA

22

Thickness Corroded

tcorroded

23

Thickness of pad

te

24

Corection factor

Strength reduction factor

fr1
fr2

25

fr3
fr4

26
27
28

Inward projection of nozzle

Nominal thickness of internal


projection of nozzle
Required thickness of
seamless nozzle

ti

FILLET SIZE EVALUATION (UW-16)


Nominal thickness of nozzle
29
wall
Nominal thickness of vessel
30
shell or head
The smaller of 3/4 in (19 mm)
31 or thickness of thinner of tn
or tin (6 mm) or
Smaller of 1/4
32 0.7 tmin (outward and inward
weld)
0.7 X tmin (inward weld if use
33
pad)
1/2 tmin (element weld if use
34
pad)

trn

tn
t
tmin
tc, t1, t2
tw
t4
WL1

35

Fillet leg size

WL2
WL3

REINFORCEMENT CALCULATION (UG-37)


36

Area required

A
A1

37

Area available in shell

A1
A1 (used)
A2

38

Area available in nozzle


projecting outward

38

Area available in nozzle


projecting outward

A2
A2 (used)
A3

39

Area available in inward


nozzle

A3
A3
A3 (used)

Area available in outward


weld

A41

41 Area available in inward weld

A43

40

42 Total available area

43

Acceptance criteria
(Adequately reinforced)

[Comparison between available area and required area

REINFORCING PAD SIZE (UG 40)


limit X1
44

Limit of Compensation
Parallel to the vessel wall (X)

limit X2
Used

45 Outside diameter of pad

Dp
limit 1

46

Limit of Compensation
Normal to the vessel wall

limit 2
Used

REINFORCEMENT CALCULATION WITH REINFORCEMENT PAD (UG 37) (UG - 41, Fig. UG - 41.1)
47

Area required

48

Area available in shell

A1 (used)
A2

49

Area available in nozzle


projecting outward

A2
A2 (used)

50
51

Area available in inward


nozzle
Area available in outward
weld

A3 (used)
A41

52

Area available in outer weld

A42

53

Area available in inward weld

A43

54

Area available in element

A5

55

Total available area

56

Acceptance criteria
(Adequately reinforced)

[Comparison between available area and required area with addit

STRENGTH OF REINFORCEMENT
57 Total Weld Load
Weld load for strength path
1-1
Weld load for strength path
59
2-2
Weld load for strength path
60
3-3
58

61 Acceptance criteria

Notes:

W
W1-1
W2-2
W3-3

[Comparison between total weld load to sum of weld load for stre
path.]

N1
WN, RF
8" SCH 80

RATING

150#

POSITION

SHELL

ELEV.

CALCULATION

REFERENCE

VALUE

ASME II Part D

118

ASME II Part D

138

ASME II Part D

138
0.5
150
1950
975

thickness + CA

7.21
4.21
Appendix 1-4 (b)

Table UG-37

0.9

UG-27

4.21

UG-45

1
2170
9.525
1075.475
2150.95
304.8

Tabel UW-12
Unadequately Reinforced (Repad is
required)UG-37 (a)

1
1
0

Unadequately
required)

Reinforced (Repad is

tact - CA

9.525
12.7

Fig. UG -37

UG-37

0.855

UG-37

0.855

UG-37

0.855

UG-37

1
23.8125
9.525
4.57

9.525
7.21
UW -16 (b)

7.21

UW -16 (b)

5.047

UW -16 (b)

5.047

UW -16 (b)

3.605
7.21
7.21
7.21

9067.123
6432.944
92.12739
the larger value

6432.944
152.7793

parison between available area and required area.]

201.834
the smaller value

152.7793
293.6116
387.8849
387.8849

the smaller value

293.6116
44.45017
44.45017

Adequately
Reinforced
Unadequately
required)

6968.235

Reinforced (Repad is

d -- {UG - 40 (b)(1)}

2150.95

UG-40 (b) (2)

1089.21

The largest of X1 or X2
{UG - 40 (b)}

2150.95
4301.9

UG-40 c

18.025

UG-40 c

23.225

largest of limit 1 or limit 2


-- {UG - 40 (c)}

23.225

Same as A above

9067.123

Same as A1 above

6432.944

NT PAD (UG 37) (UG - 41, Fig. UG - 41.1)

152.7793
773.6971
the smaller value

152.7793

ween available area and required area with addition of repad.]

ween total weld load to sum of weld load for strength at every
path.]

Same as A3 above

293.6116
44.45017
51.9841
44.45017
27075.13
34095.35

Adequately
Reinforced

UG-41 (b)(2)

370.2604

UG-41 (b)(1)

3770.759

UG-41 (b)(1)

90.07755

UG-41 (b)(1)

3833.619

Satisfactory

150#

UNIT
MPa
MPa
MPa
MPa
C
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm

SA 516 70

mm
mm
mm
mm
mm

mm
mm
mm
mm
mm
mm
mm
mm
mm

mm2
mm2
mm2
mm2
mm2

mm2
mm2
mm2
mm2
mm2
mm2
mm2
mm2
mm2

mm
mm
mm
mm
mm
mm
mm

mm2
mm2
mm2
mm2
mm2

ry

mm2
mm2
mm2
mm2
mm2
mm2

kN
kN
kN
kN

Você também pode gostar