Você está na página 1de 11

Material

rho
NPS
OD
Temp
Int. Press
CA
Mill Toleransi
S

SA 106 Grade B
0.283 lb/in
8 inch
8.625 inch
80 C
250 psi
0.02 inch
12.5 %
20 ksi

Fluida dalam pipa


rho
panjang pipa
Y
Es
Ec
Ej
Eq

Olive Oil

t
tm
nominal thickness
pemilihan pipa
t
tm
ID

R1
Intrados
I
t
tm
nominal thickness
pemilihan pipa
t
tm
ID

176 F

0.125
20000 psi

0.028 lb/in
25 ft
0.4
0.92
0.9
1
0.828

AWP

Allowable Deflection
ID
Z
I
E
self weight of pipe

300 inch

0.064713 inch
0.084713 inch
0.096815 inch
NPS 8" schedule 5s dengan
0.109 inch
0.095 inch
8.407 inch
12 (LR)
1.280488 inch
0.083044 inch
0.103044 inch
0.117765 inch
NPS 8" schedule 10s dengan
0.148 inch
0.13 inch
8.329 inch
422.8349 psi

8.407 inch
6.13 inch
26.5 inch
29.292 msi
247.5824 lb

(t yang dipakai adalah t (pipa l

(ID yang dipakai dari schedule

29292000

weight of content
weight of insulation
total weight
weight per length

466.2848 lb
0 lb
713.8672 lb
2.379557 lb/inch

span L stress
span L deflection
pipe span

143.5579 inch
77.59148 inch
77.59148 inch

Nnumber of Support

3.866404 buah

Ai
Am
Mb
Sl ax
Sl p
Sl mb
Torsi
Fs

55.5101 inch^2
2.916165 inch^2
26770.02 lb.in
4758.827 psi
4945.528 psi
4367.05 psi
214160.2 lb.in
184.6334 lb

longitudinal stress
hoop stress
shear stress

14071.41 psi
9891.055 psi
17594.83 psi

(cara pemilihan cek tm)

Extrados
I
t
tm
nominal thickness
(cara pemilihan cek tm)

0.8678 inch
0.0564 inch
0.0764 inch
0.0873 inch

t yang dipakai adalah t (pipa lurus) pemilihan schedule baru)

D yang dipakai dari schedule baru pipa lurus)

psi

Centerline
I
t
tm
nominal thickness

buah

1
0.064713 inch
0.084713 inch
0.096815 inch

nominal Size Outside Diameter

Increased casting Quality Factor (Ec)


Surface examination (1)
0.85
Magnetic particle method (2)
0.85
Ultrasonic examination (3)
0.95
Type 1 and 2
0.90
Type 1 and 3
1.00
Type 2 and 3
1.00

Straight and Spiral Longitudinal Weld Joint Quality factor


Type of Joint
Examination
Furnance butt weld
As required by specification
Electric resistance weld
As required by specification
Electric fusion weld (SBW)
As required by specification
Electric fusion weld (SBW)
Spot radiograph
Electric fusion weld (SBW)
100% radiograph
Electric fusion weld (DBW)
As required by specification
Electric fusion weld (DBW)
Spot radiograph
Electric fusion weld (DBW)
100% radiograph
By ASTM A211 spesification
As required by specification
Double submerged arc welded
Radiograph
pipe (per API 5L or 5LX)

(Ej)
Ej
0.6
0.85
0.8
0.9
1
0.85
0.9
1
0.75
0.95

Calculation factors for Span


Allowable deflection (in.)
2000
0.125
4000
0.25
6000
0.375
8000
0.5
12000
0.75
14000
0.875
16000
1
18000
1.25
20000
1.5

Common pipe insulation materials


(mass type)
Pipe insulation type
Density (lb/ft^3)
Calcium silicate
12.25
Foam glass
8.50
Polyurethane
2.00
Fiber glass
3.25
Polystyrene
2.00

Você também pode gostar