Metasol
Molded case circuit breaker / Earth leakage circuit breaker
Ics = 100%Icu
Ui = 750V
Uimp = 8kV
MCCB/ELCB
Metasol MCCB
Upgrade breaking capacity
460V
85kA
ABL400c
ABL800c
85kA
85kA
75kA
65kA
50kA
50 65kA
ABH50c
ABH125c
ABH250c
ABS400c
35 50kA
35 50kA
35 50kA
ABS125c
ABS250c
ABN400c
ABN800c
25 37kA
25 37kA
25 37kA
35 37kA
400AF
800AF
26kA
ABN250c
18 26kA
18kA
ABS800c
50 65kA
25 50kA
37kA
14kA
ABH400c
ABS50c
ABS60c
ABN100c
10 18kA
10 18kA
1018kA
ABN50c
ABN60c
5 14kA
5 14kA
5 14kA
30AF
50AF
60AF
ABS30c
100AF
125AF
250AF
S125AF :
S250AF :
H250AF :
N400AF :
S400AF :
S630AF :
S800AF :
10 18kA
25 37kA
25 37kA
35 50kA
25 37kA
50 65kA
35 50kA
50 65kA
Metasol ELCB
Upgrade breaking capacity
460V
85kA
EBL400c
EBL800c
85kA
85kA
75kA
65kA
50kA
EBS800c
5065kA
5065kA
EBH50c
EBH125c
EBH250c
EBS400c
2550kA
3550kA
3550kA
3550kA
37kA
EBS125c
EBS250c
EBN400c
EBN800c
2537kA
2537kA
2537kA
3537kA
400AF
800AF
26kA
EBN250c
1826kA
18kA
14kA
EBH400c
EBS50c
EBS60c
EBN100c
1018kA
1018kA
1018kA
EBN50c
EBN60c
514kA
514kA
514kA
30AF
50AF
60AF
EBS30c
100AF
125AF
250AF
10516560mm
9015560mm
7513060mm
Metasol MCCB
AF
Type
30AF
ABN
ABS
ABH
ABL
ABS30c
14kA
50AF
60AF
ABN50c
14kA
ABN60c
14kA
ABS50c
18kA
ABS60c
18kA
ABH50c
50kA
ABN400c
37kA
ABN800c
37kA
ABS125c
37kA
ABS250c
37kA
ABS400c
50kA
ABS800c
65kA
ABH125c
50kA
ABH250c
50kA
ABH400c
65kA
ABN100c
18kA
ABL400c
85kA
ABL800c
85kA
50mm
60mm
7513060mm
9015560mm
10516560mm
Metasol ELCB
AF
Type
30AF
EBN
EBS
EBH
EBL
EBS30c
14kA
50AF
60AF
EBN50c
14kA
EBN60c
14kA
EBS50c
18kA
EBS60c
18kA
EBH50c
50kA
EBN400c
37kA
EBN800c
37kA
EBS125c
37kA
EBS250c
37kA
EBS400c
50kA
EBS800c
65kA
EBH125c
50kA
EBH250c
50kA
EBH400c
65kA
EBN100c
18kA
EBL400c
85kA
EBL800c
85kA
System overview
Breaker
Internal auxiliaries
Plug-in kit (ELCB only)
Insulation barrier
Handle Lock
11
Internal Accessories
Internal Accessories can be commonly used in all Metasol MCCB and ELCB
(Notice: Exception of SHT, UVT in ELCB)
Internal accessories
AX
AX
AL
AL
AX
AL
AL
AX
SHT/UVT
AX
AL
AL
AX
SHT/UVT
SHT/UVT
53
103
203
13
External Accessories
Designed for various mount and user safety.
External accessories
Plug-in base
It makes to extract and/or rapidly replace the circuit breaker without having to touch
connections.(Easy replacement and maintenance)
Locking device
- Fixed padlock
- Removable padlock
- Key lock device on direct handle
Insulation barrier
These allow the insulation characteristics between the phases at the connections
to be increased.
15
MCCB
MCCB model
ABN: Economic type
ABS: Standard type
ABH: High capacity type
Standardized characteristics
Ui: Rated insulation voltage
Uimp: Impulse withstand
voltage
Ue: Rated operational voltage
Icu: Ultimate breaking
capacity
Ics: S
ervice breaking capacity
Utilization
category
Rated frequency
Manufacturer
Standard
Symbol indicating
suitability for isolation
as defined by IEC 947-2
MCCB
Upstream connections
Fixing hole
Product name
Brand name
Operating handle
Indication of closed (I/ON) position
Indication of open (O/OFF) position
Certification mark
Company logo
"push to trip" button
Fixing hole
Downstream connections
16
ELCB
ELCB model
EBN: Economic type
EBS: Standard type
EBH: High capacity type
Rated frequency
Standard
Manufacturer
Utilization category
Symbol indicating
suitability for isolation
as defined by IEC 947-2
ELCB
Upstream connections
Fixing hole
Brand name
Indication of closed (I/ON) position
Indication of open (O/OFF) position
Product name
Trip indication by earth fault
Operating handle
Residual current(In) setting
"push to trip" button for earth fault
"push to trip" button for overcurrent trip
Company logo
Certification mark
Fixing hole
Downstream connections
17
External configuration
MCCB
Handle
Function of indications
- ON OFF TRIP
Resetting
When the handle indicates "tripped" position it
must first be reset by moving the handle to
the OFF position and then closing is
possible
Trip-Free even if the handle is held at ON,
the breaker will trip if an over current flows
Suitable for Verification of the main contact
position under abnormal conditions because
the handle doesnt indicate open position
Handle
Terminal
Arc-Extinguishing
unit
Arc-Extinguishing unit
LS patent technique PASQ
Arc-Extinguishing unit
PASQ : Puffer Assisted Self-Quenching
Reduction of arc voltage for a short time
Hybrid
chamber
Contact
Mechanism
Grid
Assy
Trip
18
Trip button
ELCB
Residual
indication LED
Residual test
Button
Residual
detection unit
(ZCT + Main board)
19
MCCBs
AF
30AF
Type
50AF
60AF
E-Type
S-Type
N-Type
S-Type
H-Type
N-Type
S-Type
2-pole
ABE32b
ABS32c
ABN52c
ABS52c
ABH52c
ABN62c
ABS62c
3-pole
ABE33b
ABS33c
ABN53c
ABS53c
ABH53c
ABN63c
ABS63c
4-pole
ABS34c
ABN54c
ABS54c
ABH54c
ABN64c
ABS64c
Rated current, In
Rated operational
AC(V)
voltage, Ue
DC(V)
1, 15, 20, 30
(3, 5, 10) Note)
40, 50
460
690
690
690
690
690
690
500
500
500
500
500
500
460
750
750
750
750
750
750
2.5
2.5
10
2.5
690V
480/500V
7.5 (5)
7.5
10
35
7.5
10
415/460V
2.5
14 (10)
14
18
50
14
18
380V
2.5
18 (14)
18
22
50
18
22
30 (25)
30
35
100
30
35
500V(3P)
10
30
10
250V(2P)
10
30
10
50
100
100
100
100
100
759660mm
7513060mm
7513060mm
(Fig. 1)
(Fig. 1)
(Fig. 2)
(Fig. 1)
Ratings
34 page
36 page
38 page
38 page
40 page
Curves
98 page
98 page
98 page
99 page
98 page
Drawings
105 page
106 page
106 page
107 page
106 page
Note) 1.The short-circuit breaking capacities in ( ) are applied to the rated current in (3, 5, 10A)
2. MCCBs MCCB
can be applied to both 50 and 60Hz.
Metasol
Type
AF
30AF
ABN
ABS
ABS30c
14kA
50AF
60AF
100AF
ABN50c
14kA
ABN60c
14kA
ABN100c
18kA
ABS50c
18kA
ABS60c
18kA
125AF
250AF
ABN250c
26kA
ABS125c
37kA
ABS250c
37kA
58
22
ABH
20
ABH50c
50kA
ABH125c
50kA
50
ABH250c
50kA
60
50
64
68
75
(Fig. 1)
82
4.5
More info.
7513060mm
9015560mm
7.4
WHD
(3-pole)
130
Dimensions (mm)
100
84
Ics=%Icu
115
DC
50
220/250V
N-Type
125AF
250AF
S-Type
H-Type
N-Type
S-Type
H-Type
ABN102c
ABS102c
ABH102c
ABN202c
ABS202c
ABH202c
ABN103c
ABS103c
ABH103c
ABN203c
ABS203c
ABH203c
ABN104c
ABS104c
ABH104c
ABN204c
ABS204c
ABH204c
690
690
690
690
690
500
500
500
500
500
500
750
750
750
750
750
750
10
10
26
35
10
26
35
18
18
37
50
26
37
50
22
42
50
30
42
50
35
85
100
65
85
100
10
20
30
10
20
30
10
20
30
10
20
30
100
100
100
100
100
100
7513060mm
9015560mm
10516560mm
(Fig. 1)
(Fig. 2)
(Fig. 3)
44 page
46 page
98 page
99 page
100 page
106 page
107 page
108 page
47
165
144
126
50
102
59.4
155
100
135
50
50
8.2
8.2
42 page
4.5
100AF
58
60
60
64
68
82
90
(Fig. 2)
60
35
64
70
68.5
105
(Fig. 3)
86.85
21
MCCBs
AF
400AF
N-Type
S-Type H-Type
L-Type
2-pole
ABN402c
ABS402c ABH402c
ABL402c
3-pole
ABN403c
ABS403c ABH403c
ABL403c
4-pole
ABN404c
ABS404c ABH404c
ABL404c
Type
Type and Pole
Rated current, In
Rated operational
AC(V)
690
690 690
690
voltage, Ue
DC(V)
500
500 500
500
750
750 750
750
8 8
Rated short-circuit breaking capacity(Icu)
kA (Sym), IEC 60947-2
AC
690V
8 10
14
480/500V 18
35 50
65
415/460V 37
50 65
85
380V
42
65 70
100
220/250V 50
75 85
125
DC
500V(3P) 10
20 40
40
250V(2P) 10
20 40
40
Ics=%Icu
100 100
75
100
140257109mm
(3-pole)
(Fig. 4)
More info.
Ratings
48 page
Curves
101 page
Drawings
109 page
Note) 1.The short-circuit breaking capacities in ( ) are applied to the rated current in (3, 5, 10A)
2.Standard type is designed on the basis of 40 of ambient temperature.
800AF
ABN
ABN400c
37kA
ABN800c
37kA
ABS
ABS400c
50kA
ABS800c
65kA
ABH
ABH400c
65kA
1200AF
1000AF
13
AF
400AF
Type
3.There are certain products for hot areas. (30~250AF on the basis of 55, 400~800AF on the basis of 50)
48
215
150
41
ABS1200b
65kA
48
ABS1000b
65kA
225
257
52.5
95
105
ABL
ABL400c
85kA
ABL800c
85kA
ABL1000b
85kA
109
ABL1200b
85kA
113
145
22
(Fig. 4)
800 AF
1000 AF
1200 AF
N-Type
S-Type
L-Type S-Type
ABN802c
ABS802c
ABL802c -
- -
ABN803c
ABS803c
ABL803c ABS1003b
ABL1003b ABS1203b
ABS1203bE
ABL1203b
ABS804c
ABL804c ABS1004b
ABL1004b ABS1204b
ABL1204b
ABN804c
L-Type
1000
S-Type
L-Type
1200
690
690
690 600
600 600
600
600
500
500
500 -
- -
750
750
750 690
690
690
690
690
6 6
6 6 6
8 8 8
10
14 -
- -
25
45
65 50
75 50
50
75
37
65
85 65
85 65
65
85
45
75
100 65
85 65
65
85
50
85
125 100
125 100
100
125
10
20
40 -
- -
50
50
10
20
40 -
- -
100
100
75 50
50 50
210280109mm
220400105mm
220400105mm
(Fig. 5)
(Fig. 6)
(Fig. 6)
50 page
52 page
52 page
53 page
52 page
101 page
102 page
102 page
102 page
102 page
110 page
111 page
111 page
112 page
111 page
116
90
48.5
17
21.4
(Fig. 5)
44
70 70
220
20
113
145
40
95
105
109
90
98.5
110
400
25
96
150
243
280
53
25
56
13.5
93
(Fig. 6)
102.5
105
122.5
159
230
17
48.5
23
MCCBs
AF
30AF
Type
Type and Pole
3-pole
50AF
60AF
S-Type
N-Type
S-Type
H-Type
N-Type
S-Type
ABS33cM
ABN53cM
ABS53cM
ABH53cM
ABN63cM
ABS63cM
Rated current, In A
16, 24
60
Rated operational
AC(V)
690
690
690
690
690
690
voltage, Ue
DC(V)
500
500
500
500
500
500
750
750
750
750
750
750
AC 690V
2.5
2.5
10
2.5
480/500V
7.5
7.5
10
35
7.5
10
415/460V
14
18
50
14
18
380V
18
18
22
50
18
22
220/250V
30
30
35
100
30
35
500V(3P)
10
30
10
100
100
100
100
Dimensions (mm)
WHD
7513060mm
7513060mm
9015560mm
7513060mm
(3-pole)
(Fig. 1)
(Fig. 1)
(Fig. 2)
(Fig. 1)
More info.
Ratings
36 Page
38 Page
38 Page
40 Page
Curves
103 Page
103 Page
104 Page
103 Page
Drawings
106 Page
106 Page
107 Page
106 Page
DC
100
Ics=%Icu
14
100
ABS
ABS30cM
14kA
100AF
ABN50cM
14kA
ABN60cM
14kA
ABN100cM
18kA
ABS50cM
18kA
ABS60cM
18kA
125AF
250AF
ABN250cM
26kA
ABS125cM
37kA
ABS250cM
37kA
58
22
ABH
ABH50cM
50kA
ABH125cM
50kA
50
ABH250cM
50kA
60
50
64
68
75
82
(Fig. 1)
24
4.5
60AF
130
ABN
50AF
84
30AF
115
AF
50
Type
7.4
Metasol MCCB
100AF
125AF
N-Type
S-Type
ABN103cM
ABS103cM
250AF
H-Type
N-Type
ABH103cM
H-Type
ABS203cM
ABH203cM
60, 75, 90
60, 75, 90
S-Type
690
690
690 690
500
500
500 500
500
500
750
750
750 750
750
750
690
690
10 8
10
10
26
35 18
26
35
18
37
50 26
37
50
22
42
50 30
42
50
35
85
100 65
85
100
10
20
30 10
20
30
100
100
100
100
100
100
10516560mm
(Fig. 1)
(Fig. 2)
(Fig. 3)
42 Page
44 Page
46 Page
103 Page
104 Page
104 Page
106 Page
107 Page
108 Page
58
60
60
64
68
82
90
(Fig. 2)
47
165
144
126
50
102
59.4
155
100
135
50
50
8.2
9015560mm
8.2
7513060mm
4.5
60
35
64
70
68.5
105
86.85
(Fig. 3)
25
MCCBs
AF
30AF
50AF
H-Type
N-Type
S-Type
ABH52c
ABN53c
ABS53c
ABH53c
ABN63c
ABS63c
ABN54c
ABS54c
ABH54c
ABN64c
ABS64c
S-Type
N-Type
3-pole
ABS33c
4-pole
ABS34c
Type
Type and Pole
2-pole
Rated current, In
Rated operational
voltage, Ue
15, 20, 30
750
S-Type
690
AC(V)
60AF
750
750
750
690 690
690
690 690
750
750
Rated short-circuit breaking capacity(Icu) kA (Sym), IEC 60947-2
2.5
2.5
10
2.5
480/500V
7.5
7.5
10
35
7.5
10
415/460V
14
14
18
50
14
18
380V
18
18
22
50
18
22
220/250V
30
30
35
100
30
35
100
100
100
100
100
AC
690V
Ics=%Icu
100
7513060mm
7513060mm
9015560mm
7513060mm
(3-pole)
(Fig. 1)
(Fig. 1)
(Fig. 2)
(Fig. 1)
More info.
Ratings
36 page
38 page
38 page
40 page
Curves
98 page
98 page
99 page
98 page
Drawings
106 page
106 page
107 page
106 page
Dimensions (mm)
WHD
ABS
ABS30c
14kA
100AF
ABN50c
14kA
ABN60c
14kA
ABN100c
18kA
ABS50c
18kA
ABS60c
18kA
125AF
250AF
ABN250c
26kA
ABS125c
37kA
ABS250c
37kA
58
22
ABH
ABH50c
50kA
ABH125c
50kA
ABH250c
50kA
60
50
64
68
75
(Fig. 1)
26
50
82
4.5
60AF
130
ABN
50AF
84
30AF
115
AF
50
Type
7.4
125AF
250AF
N-Type
S-Type
H-Type
N-Type
S-Type
ABS102c
ABH102c
ABN103c
ABS103c
ABH103c
ABN203c
ABS203c
ABH203c
ABN104c
ABS104c
ABH104c
ABN204c
ABS204c
ABH204c
690
690
750
750
750
10
10
26
18
H-Type
-
750
10
35
18
26
35
37
50
26
37
50
22
42
50
30
42
50
35
85
100
65
85
100
100
100
100
100
100
750
750
100
7513060mm
9015560mm
10516560mm
(Fig. 1)
(Fig. 2)
(Fig. 3)
44 page
46 page
98 page
99 page
100 page
106 page
107 page
108 page
58
60
90
(Fig. 2)
60
64
68
82
47
165
144
126
50
102
59.4
155
100
135
50
50
8.2
8.2
42 page
4.5
100AF
60
35
64
70
68.5
105
(Fig. 3)
86.85
27
MCCBs
AF
400AF
N-Type
Type
Type and Pole
S-Type H-Type
L-Type
2-pole
3-pole
ABN403c
ABS403c ABH403c
ABL403c
4-pole
ABN404c
ABS404c ABH404c
ABL404c
Rated current, In
Rated operational
AC(V)
690
690 690
690
750
750 750
750
voltage, Ue
8 8
Rated short-circuit breaking capacity(Icu)
kA (Sym), IEC 60947-2
AC
690V
8 10
14
480/500V 18
35 50
65
415/460V 37
50 65
85
380V
65 70
100
75 85
125
100 100
75
42
220/250V 50
Ics=%Icu
100
140257109mm
(3-pole)
(Fig. 4)
More info.
Ratings
48 page
Curves
101 page
Drawings
109 page
28
AF
400AF
800AF
ABN
ABN400c
37kA
ABN800c
37kA
ABS
ABS400c
50kA
ABS800c
65kA
ABH
ABH400c
65kA
ABL
ABL400c
85kA
Type
ABL800c
85kA
800 AF
N-Type
S-Type
L-Type
ABN803c
ABS803c
ABL803c
690 690 690
750
750
750
8 8 8
10
14
25
45
65
37
65
85
45
75
100
50
85
125
100
100
75
210280109mm
(Fig. 5)
50 page
101 page
96
150
243
280
48
41
48
215
53
150
225
257
52.5
25
56
13.5
13
110 page
95
95
105
109
105
109
113
(Fig. 4)
145
(Fig. 5)
113
145
29
ELCBs
AF
30AF
50AF
60AF
S-Type
N-Type
S-Type
H-Type
N-Type
S-Type
EBN52c
3-pole
EBS33c
EBN53c
EBS53c
EBH53c
EBN63c
EBS63c
4-pole
EBS34c
EBS54c
EBH54c
EBS64c
Type
Type and Pole
2-pole
Protective function
Rated current, In
Overload, Short-circuit
Overload, Short-circuit
Overload, Short-circuit
Overload, Short-circuit
60
30, 100/200/500mA
30, 100/200/500mA
30, 100/200/500mA
30,100/200/500mA
220/460
220/460
220/460
220/460
0.1 sec
0.1 sec
0.1 sec
0.1 sec
(5, 10)
, 15, 20, 30
Note) 3
kV
14 (10)
14 18
50
14
18
220/250V
30 (25)
30 35
100
30
35
Ics=%Icu 100
100
100 100
100
100
100
AC
Dimensions (mm)
WHD
9015560mm
7513060mm
(Fig. 1)
(Fig. 2)
(Fig. 1)
7513060mm 7513060mm
(3-pole)
(Fig. 1)
More info.
Ratings
56 page
58 page
58 page
60 page
Curves
98 page
98 page
99 page
98 page
Drawings
113 page
113 page
114 page
113 page
AF
30AF
EBN
EBS
EBH
EBS30c
14kA
50AF
60AF
100AF
EBN50c
14kA
EBN60c
14kA
EBN100c
18kA
EBS50c
18kA
EBS60c
18kA
EBH50c
50kA
125AF
4.5
Type
7.4
250AF
EBN250c
26kA
EBS125c
37kA
EBS250c
37kA
EBH125c
50kA
EBH250c
50kA
(Fig. 1)
30
125AF
250AF
N-Type
S-Type
H-Type
N-Type
S-Type
H-Type
EBN102c
EBN202c
EBN103c
EBS103c
EBH103c
EBN203c
EBS203c
EBH203c
EBN104c
EBS104c
EBH104c
EBS204c
EBH204c
Overload, Short-circuit
Overload, Short-circuit
Overload, Short-circuit
30, 100/200/500mA
30,100/200/500mA
30,100/200/500mA
220/460
220/460
220/460
0.1 sec
0.1 sec
0.1 sec
18
37
50
26
37
50
35
85
100
65
85
100
100
100
100
100
100
100
10516560mm
(Fig. 1)
(Fig. 2)
(Fig. 3)
62 page
64 page
66 page
98 page
99 page
100 page
113 page
114 page
115 page
165
144
102
50
135
155
50
47
4.7
100
50
8.2
9015560mm
8.2
7513060mm
4.5
100AF
60
58
60
90
64
68
60
35
64
70
66.5
105
68.5
82
(Fig. 2)
86.85
(Fig. 3)
31
ELCBs
AF
400AF
N-Type
S-Type
H-Type
L-Type
3-pole
EBN403c
EBS403c
EBH403c
EBL403c
4-pole
EBN404c
EBS404c
EBH404c
EBL404c
Type
Type and Pole
Protective function
Rated current, In
30, 100/200/500mA
220/460
voltage, Uimp
kV
220/460
220/460
220/460
6 6 6
0.1 sec
0.1 sec
0.1 sec
0.1 sec
Rated short-circuit breaking capacity
(Icu) kA (Sym), IEC 60947-2
AC
415/460V 37
50
65
85
220/250V 50
75
85
125
100
100
75
Ics=%Icu
Dimensions (mm)
100
WHD
140257109mm
(3-pole)
(Fig. 4)
More info.
Ratings
68 page
Curves
101 page
Drawings
116 page
EBS
EBS400c
50kA
EBS800c
65kA
EBH
EBH400c
65kA
EBS1000b
65kA
EBS1200b
65kA
EBN800c
37kA
150
EBN400c
37kA
1200AF
215
EBN
1000AF
225
800AF
257
AF
400AF
Type
13
Note) 1. MCCBs other than 1000/1200AF can be applied to both 50 and 60Hz.
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
95
105
EBL
EBL400c
85kA
109
EBL800c
85kA
113
145
(Fig. 4)
32
800 AF
1000 AF
1200 AF
N-Type
S-Type
L-Type S-Type
S-Type
EBN803c
EBS803c
EBL803c EBS1003b
EBS1203b
- -
220/460
1000
1200
30, 100/200/500mA
100/200/500mA
100/200/500mA
220/460 220/460
220/460
220/460
6 6 6
0.1 sec
0.1 sec
- -
0.1 sec
0.1 sec
0.1 sec
37
65
85 85
85
50
85
125 125
125
100
100
75 -
210280109mm
220565105mm
(Fig. 5)
(Fig. 6)
70 page
70 page
101 page
102 page
117 page
118 page
21.4
98.5
110
400
360
25
206
165
165
525
13.5
96
95
109
113
(Fig. 5)
145
40
90
105
44
70 70
220
20
243
150
280
48.5
17
90
116
93
(Fig. 5)
102.5
105
122.5
159
231
17
48.5
33
30AF MCCB
ABE30b
Ratings
30AF
Frame size
Type and Pole
E-Type
2-pole
ABE32b
3-pole
ABE33b
4-pole
Rated current, In
3-5-10-15-20-30A
AC : 460V
AC : 460V
ABE32b
6kV
E-Type
AC 690V
460V
2.5kA
415V
2.5kA
380V
2.5kA
220/250V
ABE33b
5kA
DC 500V (3P)
250V (2P)
lcs=%Icu
50%
Protective function
Overload, Short-circuit
Hydraulic-Magnetic
12In
8500 operations
Mechanical
Electrical
1500 operations
Connection
Front connection
Standard
Optional
Mounting
Dimensions (mm)
2p
3p
50
75
96
96
c1 Note)
60
60
c2 Note)
80
80
Pole
d
a
c2
c1
105 page
Trip curves
98 page
Accessories
74 page
Screw fixing
Standard
Weight, kg
Standard
0.5
0.7
2p
3p
Certification Pole
CE marking
Note) Depth by door cut size : c1 for large cut, c2 for small cut
34
Ordering types
Breaker types
Accessories
ABE type (2.5kA/460V)
Rated current, In
2-pole
3-pole
3A
ABE32b/3
ABE33b/3
5A
ABE32b/5
ABE33b/5
10 A
ABE32b/10
ABE33b/10
15 A
ABE32b/15
ABE33b/15
20 A
ABE32b/20
ABE33b/20
30 A
ABE32b/30
ABE33b/30
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
SHT
Shunt Trip
Maximum possibilities
T-position
R-position
Option of AX or AL
External accessories
Name
ABE30b
B-03B
Insulation barrier
TBS23
Short type
35
30AF MCCB
ABS30c
Ratings
Frame size
30AF
S-Type
2-pole
ABS32c
3-pole
ABS33c
4-pole
ABS34c
Rated current, In
(3-5-10)-15-20-30A
AC: 690V
DC: 500V
ABS32c
AC: 750V
8kV
S-Type
capacity, Icu
2.5 kA
AC 690V
7.5 (5)kA
480/500V
IEC 60947-2 (lcu)
415V
14 (10)kA
380V
18 (14)kA
220/250V
30 (25)kA
ABS33c
14 (10)kA
460V
5 kA
DC 500V(3P)
250V(2P)
5 kA
lcs=%Icu
100%
Protective function
Overload, Short-circuit
Thermal-Magnetic
400A
Mechanical
25000 operations
Electrical
10000 operations
Connection
Front connection
Standard
Optional
Rear connection
Plug-in
ABS34c
Mounting
Standard
Dimensions (mm)
2p
3p
4p
d
a
50
75
100
a
c1
b
130
130
130
c1 Note) 2
60
60
60
c2 Note) 2
64
64
64
82
82
82
0.7
0.9
2p
3p
4p
Pole
c2
106 page
Trip curves
98 page
Accessories
74 page
Screw fixing
Weight, kg
Standard
Certification Pole
CE marking
0.5
Note) 1. The short-circuit breaking capacities in ( )are applied to the rated current in (3, 5, 10A)
2. Depth by door cut size : c1 for large cut, c2 for small cut
3. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
36
Ordering types
Breaker types
Accessories
ABS type (10kA/460V)
Rated current, In
2-pole
3-pole
4-pole
3A
ABS32c/3
ABS33c/3
ABS34c/3
5A
ABS32c/5
ABS33c/5
ABS34c/5
10 A
ABS32c/10
ABS33c/10
ABS34c/10
Electrical auxiliaries
ABS type (14kA/460V)
Rated current, In
2-pole
3-pole
4-pole
15 A
ABS32c/15
ABS33c/15
ABS34c/15
20 A
ABS32c/20
ABS33c/20
ABS34c/20
30 A
ABS32c/30
ABS33c/30
ABS34c/30
AX
Auxiliary Switch
AL
Alarm Switch
AX+AL
Combination switch
SHT
Shunt Trip
UVT
Undervoltage trip
Maximum possibilities
T-position
R-position
Option of AX or AL or AX+AL
External accessories
Name
ABS30c
IB13
Insulation barrier
TCL13
TCS13
DH100
DHK100
EH100
RTR1
PB-A3
Plug-in kit
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
37
50AF MCCB
ABN50c, ABS50c, ABH50c
Ratings
50AF
Frame size
N-Type
S-Type
2-pole
ABN52c
ABS52c
ABH52c
3-pole
ABN53c
ABS53c
ABH53c
4-pole
ABN54c
ABS54c
ABH54c
H-Type
15-20-30-40-50A
Rated current, In
AC: 690V
DC: 500V
AC: 750V
ABS52c
8kV
N-Type
capacity, Icu
AC 690V
480/500V
H-Type
5kA
10kA
7.5kA
10kA
35kA
14kA
18kA
50kA
415V
14kA
18kA
50kA
380V
18kA
22kA
50kA
220/250V
460V
30kA
35kA
100kA
DC 500V(3P)
5kA
10kA
30kA
250V(2P)
5kA
ABS53c
S-Type
2.5kA
100%
lcs=%Icu
Protective function
10kA
30kA
100%
100%
Overload, Short-circuit
Thermal-Magnetic
25000 operations
Electrical
10000 operations
Connection
Front connection
Standard
Optional
Rear connection
Plug-in
ABS54c
Mounting
Standard
Dimensions (mm)
Screw fixing
2p
3p
4p
2p
3p
4p
2p
3p
4p
a
d
50
75
100
50
75
100
60
90
120
a
c1
b
130
130
155
c1 Note)
60
60
60
c2 Note)
64
64
64
82
82
82
Pole
c2
Trip curves
98, 99 page
Accessories
74 page
Weight, kg
Standard 0.5
Certification Pole
CE marking
0.7
0.9
0.5
0.7
0.9
0.7
1.2
2p
3p
4p
2p
3p
4p
2p
3p
4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
38
Ordering types
Breaker types
Accessories
ABN type (14kA/460V)
Rated current, In
2-pole
3-pole
4-pole
15 A
ABN52c/15
ABN53c/15
ABN54c/15
20 A
ABN52c/20
ABN53c/20
ABN54c/20
30 A
ABN52c/30
ABN53c/30
ABN54c/30
40 A
ABN52c/40
ABN53c/40
ABN54c/40
50 A
ABN52c/50
ABN53c/50
ABN54c/50
Rated current, In
15 A
Electrical auxiliaries
AX
Auxiliary Switch
2-pole
4-pole
AL
Alarm Switch
ABS54c/15
AX+AL
ABS52c/15
3-pole
ABS53c/15
20 A
ABS52c/20
ABS53c/20
ABS54c/20
30 A
ABS52c/30
ABS53c/30
ABS54c/30
40 A
ABS52c/40
ABS53c/40
ABS54c/40
50 A
ABS52c/50
ABS53c/50
ABS54c/50
2-pole
3-pole
4-pole
15 A
ABH52c/15
ABH53c/15
ABH54c/15
20 A
ABH52c/20
ABH53c/20
ABH54c/20
30 A
ABH52c/30
ABH53c/30
ABH54c/30
40 A
ABH52c/40
ABH53c/40
ABH54c/40
50 A
ABH52c/50
ABH53c/50
ABH54c/50
Combination switch
SHT
Shunt Trip
UVT
Undervoltage trip
Maximum possibilities
T-position
R-position
Option of AX or AL or AX+AL
External accessories
ABN50c
ABS50c
Name
ABH50c
IB13
IB23
TCL13
TCL23
TCS13
TCS23
DH100
DH125
DHK100 DHK125
Insulation barrier
EH100
EH125
RTB2
RTR1
RTR2
PB-A3
PB-C3
Plug-in kit
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
39
60AF MCCB
ABN60c, ABS60c
Ratings
60AF
Frame size
N-Type
S-Type
2-pole
ABN62c
ABS62c
3-pole
ABN63c
ABS63c
4-pole
ABN64c
ABS64c
15-20-30-40-50-60A
Rated current, In
AC: 690V
DC: 500V
AC: 750V
ABS62c
8kV
N-Type
capacity, Icu
AC 690V
S-Type
2.5kA
480/500V
5kA
7.5kA
10kA
14kA
18kA
415V
14kA
18kA
380V
18kA
22kA
460V
220/250V 30kA
ABS63c
35kA
DC 500V(3P)
5kA
250V(2P)
5kA
10kA
100%
100%
lcs=%Icu
Protective function
10kA
Overload, Short-circuit
Thermal-Magnetic
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Plug-in
ABS64c
Mounting
Screw fixing
Standard
Dimensions (mm)
Pole
2p 3p 4p 2p 3p 4p
a
d
a
c1
b
130
130
c1 Note)
c2
50
75
100
50
75
60
60
64
64
c2 Note)
100
106 page
Trip curves
98 page
Accessories
74 page
Weight, kg
Standard
Certification Pole
CE marking
0.5
82
82
0.7
0.7
0.9
0.9
2p 3p 4p 2p 3p 4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
40
0.5
Ordering types
Breaker types
Accessories
ABN type (14kA/460V)
Rated current, In
2-pole
3-pole
4-pole
15 A
ABN62c/15
ABN63c/15
ABN64c/15
20 A
ABN62c/20
ABN63c/20
ABN64c/20
30 A
ABN62c/30
ABN63c/30
ABN64c/30
40 A
ABN62c/40
ABN63c/40
ABN64c/40
50 A
ABN62c/50
ABN63c/50
ABN64c/50
60 A
ABN62c/60
ABN63c/60
ABN64c/60
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
Rated current, In
2-pole
3-pole
4-pole
AX+AL
15 A
ABS62c/15
ABS63c/15
ABS64c/15
SHT
Shunt Trip
20 A
ABS62c/20
ABS63c/20
ABS64c/20
UVT
Undervoltage trip
30 A
ABS62c/30
ABS63c/30
ABS64c/30
40 A
ABS62c/40
ABS63c/40
ABS64c/40
50 A
ABS62c/50
ABS63c/50
ABS64c/50
T-position
60 A
ABS62c/60
ABS63c/60
ABS64c/60
R-position
Option of AX or AL or AX+AL
Combination switch
Maximum possibilities
External accessories
ABS60c
Name
ABN60c
IB13
Insulation barrier
TCL13
TCS13
DH100
DHK100
EH100
RTB1
RTR1
PB-A3
Plug-in kit
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
41
100AF MCCB
ABN100c
Ratings
100AF
Frame size
Type and Pole
N-Type
2-pole
ABN102c
3-pole
ABN103c
ABN104c
4-pole
15-20-30-40-50-60-75-100A
Rated current, In
AC: 690V
DC: 500V
AC: 750V
ABN102c
8kV
N-Type
AC 690V
5kA
480/500V
IEC 60947-2 (lcu)
ABN103c
10kA
460V
18kA
415V
18kA
380V
22kA
220/250V
35kA
10kA
DC 500V(3P)
250V(2P)
10kA
lcs=%Icu
100%
Protective function
Overload, Short-circuit
Thermal-Magnetic
400A
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Plug-in
ABN104c
Mounting
Screw fixing
Standard
Dimensions (mm)
Pole
a
d
2p 3p 4p
50
75
100
130 130
130
c1 Note)
60
60
60
c2 Note)
64
64
64
82
82
82
0.5
0.7
0.9
c2
a
c1
b
106 page
Trip curves
98 page
Accessories
74 page
Weight, kg
Standard
Certification Pole
CE marking
2p 3p 4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
42
Ordering types
Breaker types
Accessories
ABN type (14kA/460V)
Rated current, In
2-pole
3-pole
4-pole
15 A
ABN102c/15
ABN103c/15
ABN104c/15
20 A
ABN102c/20
ABN103c/20
ABN104c/20
30 A
ABN102c/30
ABN103c/30
ABN104c/30
40 A
ABN102c/40
ABN103c/40
ABN104c/40
50 A
ABN102c/50
ABN103c/50
ABN104c/50
60 A
ABN102c/60
ABN103c/60
ABN104c/60
Electrical auxiliaries
75 A
ABN102c/75
ABN103c/75
ABN104c/75
AX
Auxiliary Switch
100 A
ABN102c/100
ABN103c/100
ABN104c/100
AL
Alarm Switch
AX+AL
Combination switch
SHT
Shunt Trip
UVT
Undervoltage trip
Maximum possibilities
T-position
R-position
Option of AX or AL or AX+AL
External accessories
Name
ABN100c
IB13
Insulation barrier
TCL13
TCS13
DH100
DHK100
EH100
RTB1
RTR1
PB-A3
Plug-in kit
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
43
125AF MCCB
ABS103c, ABH103c
Ratings
125AF
Frame size
Type and Pole
S-Type
H-Type
2-pole
ABS102c
ABH102c
3-pole
ABS103c
ABH103c
4-pole
ABS104c
ABH104c
15-20-30-40-50-60-75-100-125A
Rated current, In
AC: 690V
DC: 500V
AC: 750V
8kV
ABS102c
S-Type
H-Type
capacity, Icu
8kA
10kA
AC 690V
480/500V
26kA
35kA
37kA
50kA
415V
37kA
50kA
380V
42kA
50kA
220/250V
85kA
100kA
20kA
30kA
460V
DC 500V(3P)
250V(2P) 20kA
30kA
100%
100%
lcs=%Icu
ABS103c
Protective function
Overload, Short-circuit
Thermal-Magnetic
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Plug-in
Mounting
Dimensions (mm)
ABS104c
Pole
d
a
c2
c1
Drawings
107 page
Trip curves
99 page
Accessories
74 page
2p 3p 4p 2p 3p 4p
60
90
120
90
155
155
c1 Note)
60
60
c2 Note)
64
64
82
82
Weight, kg
Standard
Certification Pole
CE marking
0.7
1.2
0.7
120
1.2
2p 3p 4p 2p 3p 4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
44
60
b
b
Screw fixing
Standard
Ordering types
Breaker types
Accessories
ABS type (37kA/460V)
Rated current, In
2-pole
3-pole
4-pole
15 A
ABS102c/15
ABS103c/15
ABS104c/15
20 A
ABS102c/20
ABS103c/20
ABS104c/20
30 A
ABS102c/30
ABS103c/30
ABS104c/30
40 A
ABS102c/40
ABS103c/40
ABS104c/40
50 A
ABS102c/50
ABS103c/50
ABS104c/50
60 A
ABS102c/60
ABS103c/60
ABS104c/60
Electrical auxiliaries
75 A
ABS102c/75
ABS103c/75
ABS104c/75
AX
Auxiliary Switch
100 A
ABS102c/100
ABS103c/100
ABS104c/100
AL
Alarm Switch
125 A
ABS102c/125
ABS103c/125
ABS104c/125
AX+AL
Combination switch
SHT
Shunt Trip
UVT
Undervoltage trip
Rated current, In
2-pole
3-pole
4-pole
15 A
ABH102c/15
ABH103c/15
ABH104c/15
20 A
ABH102c/20
ABH103c/20
ABH104c/20
T-position
30 A
ABH102c/30
ABH103c/30
ABH104c/30
R-position
Option of AX or AL or AX+AL
40 A
ABH102c/40
ABH103c/40
ABH104c/40
50 A
ABH102c/50
ABH103c/50
ABH104c/50
60 A
ABH102c/60
ABH103c/60
ABH104c/60
75 A
ABH102c/75
ABH103c/75
ABH104c/75
100 A
ABH102c/100
ABH103c/100
ABH104c/100
125 A
ABH102c/125
ABH103c/125
ABH104c/125
Maximum possibilities
External accessories
ABS125c
Name
ABH125c
IB23
Insulation barrier
TCL23
TCS23
DH125
DHK125
EH125
RTB2
RTR2
PB-C3
Plug-in kit
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
45
250AF MCCB
ABN250c, ABS250c, ABH250c
Ratings
250AF
Frame size
Type and Pole
N-Type S-Type H-Type
2-pole
ABN202c
ABS202c
ABH202c
3-pole
ABN203c
ABS203c
ABH203c
4-pole
ABN204c
ABS204c
ABH204c
100-125-150-175-200-225-250A
Rated current, In
AC: 690V
DC: 500V
AC: 750V
8kV
N-Type
S-Type
H-Type
capacity, Icu
8kA
8kA
10kA
AC 690V
480/500V
18kA
26kA
35kA
26kA
37kA
50kA
415V
26kA
37kA
50kA
380V
30kA
42kA
50kA
220/250V
65kA
85kA
100kA
DC 500V(3P)
10kA
20kA
30kA
250V(2P)
10kA
ABS203c
460V
lcs=%Icu
100%
Protective function
20kA
30kA
100%
100%
Overload, Short-circuit
Thermal-Magnetic
12In
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Plug-in
Mounting
Dimensions (mm)
ABS204c
2p
3p
4p
2p
3p
4p
2p
3p
4p
105
105
140
105
105
140
105
105
140
a
c1
b
165
165
165
c1 Note)
60
60
60
c2 Note)
64
64
64
87
87
87
1.2
1.6
1.1
1.2 1.6
2p
3p
4p
2p
3p
2p
Pole
d
a
c2
108 page
Trip curves
100 page
Accessories
74 page
Screw fixing
Standard
Weight, kg
Standard 1.1
Certification Pole
CE marking
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
46
4p
3p
4p
Ordering types
Breaker types
Accessories
ABN type (25kA/460V)
Rated current, In
2-pole
3-pole
4-pole
100 A
ABN202c/100
ABN203c/100
ABN204c/100
125 A
ABN202c/125
ABN203c/125
ABN204c/125
150 A
ABN202c/150
ABN203c/150
ABN204c/150
175 A
ABN202c/175
ABN203c/175
ABN204c/175
200 A
ABN202c/200
ABN203c/200
ABN204c/200
225 A
ABN202c/225
ABN203c/225
ABN204c/225
250 A
ABN202c/250
ABN203c/250
ABN204c/250
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
AX+AL
Combination switch
Rated current, In
2-pole
3-pole
4-pole
SHT
Shunt Trip
100 A
ABS202c/100
ABS203c/100
ABS204c/100
UVT
Undervoltage trip
125 A
ABS202c/125
ABS203c/125
ABS204c/125
150 A
ABS202c/150
ABS203c/150
ABS204c/150
175 A
ABS202c/175
ABS203c/175
ABS204c/175
T-position
200 A
ABS202c/200
ABS203c/200
ABS204c/200
R-position
Option of AX or AL or AX+AL
225 A
ABS202c/225
ABS203c/225
ABS204c/225
250 A
ABS202c/250
ABS203c/250
ABS204c/250
Maximum possibilities
2-pole
3-pole
4-pole
100 A
ABH202c/100
ABH203c/100
ABH204c/100
125 A
ABH202c/125
ABH203c/125
ABH204c/125
150 A
ABH202c/150
ABH203c/150
ABH204c/150
175 A
ABH202c/175
ABH203c/175
ABH204c/175
200 A
ABH202c/200
ABH203c/200
ABH204c/200
225 A
ABH202c/225
ABH203c/225
ABH204c/225
250 A
ABH202c/250
ABH203c/250
ABH204c/250
External accessories
Name
ABH250c
B33
Insulation barrier
TCL33
TCS33
DH250
DHK250
EH250
RTB3
RTR3
PBA250C
Plug-in kit
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
47
400AF MCCB
ABN400c, ABS400c, ABH400c, ABL400c
Ratings
400AF
Frame size
Type and Pole
N-Type
S-Type
H-Type
2-pole
ABN402c
ABS402c
ABH402c
ABL402c
3-pole
ABN403c
ABS403c
ABH403c
ABL403c
4-pole
ABN404c
ABS404c
ABH404c
ABL404c
L-Type
250-300-350-400A
Rated current, In
AC: 690V
DC: 500V
AC: 750V
8kV
ABS403c
capacity, Icu
5kA
AC 690V
35kA
50kA
65kA
65kA
85kA
380V 42kA
65kA
70kA
100kA
220/250V 50kA
75kA
85kA
125kA
DC 500V(3P) 10kA
20kA
40kA
40kA
250V(3P) 10kA
20kA
40kA
40kA
100%
100%
100%
75%
Overload, Short-circuit
Thermal-Magnetic
8~12In
Mechanical
1000 operations
Connection
Front connection
Standard
Mounting
Standard
Dimensions (mm)
Pole
d
a
c2
c1
101 page
Accessories
75 page
Plug-in
Screw fixing
2p 3p 4p 2p 3p 4p 2p 3p 4p 2p 3p 4p
140 140 184 140 140 184 140 140 184 140 140 184
c1 Note)
109 page
4000 operations
Electrical
Optional
Trip curves
c2 Note)
Weight, kg
Standard 5.2 6.2 7.8 5.2 6.2 7.8 5.2 6.2 7.8 5.2 6.2 7.8
Certification Pole
CE marking
2p 3p 4p 2p 3p 4p 2p 3p 4p 2p 3p 4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
48
14kA
50kA
Protective function
Drawings
10kA
415/460V 37kA
lcs=%Icu
8kA
18kA
480/500V
IEC 60947-2 (lcu)
ABL404c
Ordering types
Breaker types
Accessories
ABN type (37kA/460V)
Rated current, In
2-pole
3-pole
4-pole
250 A
300 A
350 A
400 A
2-pole
3-pole
4-pole
250 A
300 A
350 A
400 A
2-pole
3-pole
4-pole
250 A
300 A
350 A
400 A
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
SHT
Shunt Trip
UVT
Undervoltage trip
Maximum possibilities
T-position
R-position
2-pole
3-pole
4-pole
250 A
300 A
350 A
400 A
N-70
External accessories
IBL400
Insulation barrier
T1-43A
T1-44A
N-70
E-70U
MI-43
MI-44
PB-I3-FR
Plug-in kit
49
800AF MCCB
ABN800c, ABS800c, ABL800c
Ratings
800AF
Frame size
Type and Pole
N-Type
S-Type
2-pole
ABN802c
ABS802c
ABL802c
3-pole
ABN803c
ABS803c
ABL803c
4-pole
ABN804c
ABS804c
Rated current, In
L-Type
ABL804c
500-630-700-800A
AC: 690V
DC: 500V
AC: 750V
ABS803c
8kV
N-Type
capacity, Icu
8kA
AC 690V
S-Type
L-Type
10kA
14kA
415/460V
380V 45kA
75kA
100kA
220/250V 50kA
85kA
125kA
lcs=%Icu
100%
Protective function
ABL804c
100%
Overload, Short-circuit
Thermal-Magnetic
8~12In
2500 operations
Mechanical
500 operations
Electrical
Connection
Front connection
Standard
Plug-in
Optional
Mounting
Pole
Trip curves
101 page
Accessories
75 page
3p
4p
2p
3p
2p
3p
4p
c1 Note)
c2 Note)
c1
Weight, kg
Certification Pole
CE marking
2p
3p
4p
2p
3p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
50
4p
110 page
2p
a
c2
a
Drawings
Screw fixing
Standard
Dimensions (mm)
75%
4p
2p
3p
4p
Ordering types
Breaker types
Accessories
ABN type (37kA/460V)
Rated current, In
2-pole
3-pole
4-pole
500 A
630 A
700 A
800 A
2-pole
3-pole
4-pole
500 A
630 A
700 A
800 A
2-pole
3-pole
4-pole
500 A
630 A
700 A
800 A
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
SHT
Shunt Trip
UVT
Undervoltage trip
Maximum possibilities
T-position
R-position
E-80U
N-80
External accessories
IBL800
Insulation barrier
T1-63A
T1-64A
N-80
E-80U
MI-83S
MI-84S
PB-J3-FR
Plug-in kit
51
1000/1200AF MCCB
ABS1000b/1200b, ABL1000b/1200b
Ratings
Frame size
1000AF
1200AF
S-Type
L-Type
S-Type
2-pole
3-pole
ABS1003b
ABL1003b
ABS1203b
ABL1203b
4-pole
ABS1004b
ABL1004b
ABS1204b
ABL1204b
Rated current, In
1000A
AC: 600V
690V
6kV
capacity, Icu
45kA 65kA
S-Type L-Type
S-Type L-Type
45kA 65kA
50kA 75kA
65kA 85kA
65kA 85kA
220/250V 100kA 125kA
100kA 125kA
lcs=%Icu
Adjustable instantaneous
for each phase
1200A
AC 690V
L-Type
50% 50%
Protective function
50% 50%
Overload, Short-circuit
Thermal-Magnetic
3~6In ...
Mechanical
2500 operations
Electrical
500 operations
Connection
Standard
Front connection
Mounting
Standard
Screw fixing
Dimensions (mm)
Pole
3p
4p
3p
4p
c2
a
220
290
220
290
400
400
400
400
105
105
105
105
159
159
159
159
Standard
19.6
25.7
19.6
25.7
c1
Weight, kg
Certification
Pole
CE marking
3p 4p
ABS1003b
ABS1004b
3p 4p
ABS1203b
ABS1204b
Drawings
111 page
Trip curves
102 page
52
Ordering types
Breaker types
Rated current, In
MCCB
3-pole
4-pole
1000 A
ABS1003b/1000
ABS1004b/1000
1200 A
ABS1203b/1200
ABS1204b/1200
ON
OFF
TRIP
AX
3-pole
4-pole
1000 A
ABL1003b/1000
ABL1004b/1000
1200 A
ABL1203b/1200
ABL1204b/1200
AL
AX2
AL1
AL2
AX1+AL
AX2+AL
Voltage
(V)
AC
DC
Current (A)
Voltage
Current (A)
(V)
125
20
20
30
250
20
20
125
0.4
0.05
500
10
250
0.2
0.03
Shunt Trip
UVT
Undervoltage trip
AC
DC
100~110V
125V
200~220V
380~440V
480~550V
24V
48V
100~110V
125V
200~220V
Time rating
Operational voltage
Continuous
100~110V
125V
200~220V
380~440V
Time rating
Operational voltage
Trip voltage
Continuous
85~110% of
control voltage
20~70% of
control voltage
53
Ratings
1200AF
Frame size
Type and Pole
S-Type
2-pole
3-pole
ABS1203bE
4-pole)
Rated current, In
1200A
AC: 600V
AC: 600V
Long time
pick-up time
Short time
pick-up time
Current, IR
Current, Im
Instantaneous Current, It
pick-up time
LED Pre-Alarm
Rated frequency
(0.5-0.6-0.7-0.8-0.9-1.0)In, adjustable...
5sec 20% at 6Ir, fixed
(2-3-4-5-6-8-10)ln, adjustable...
0.1-0.2-0.3 sec, adjustable...
11ln, fixed
within 0.03 sec, fixed
between 70 to 110% of set current Ir: LED flickering
over 110% of set current Ir: stays on
50-60Hz selectable by the switch of the trip unit
S-Type
AC 690V
45kA
480/500V
50kA
415/460V
65kA
380V
65kA
220/250V
100kA
lcs=%Icu
50%
Protective function
Overload, Short-circuit
Electronic type
Endurance
Mechanical
Electrical
500 operations
Connection
Standard
Front connection
Mounting
Standard
Screw fixing
Dimensions (mm)
d
Pole
2500 operations
3p
c2
a
a
c1
220
400
105
6kV
Drawings
112 page
159
Trip curves
102 page
Weight, kg
21
54
Standard
Ordering types
Breaker types
MCCB
ON
OFF
TRIP
Rated current, In 3P
1200 A
ABS1203bE
AX
AL
AX1
AX2
Voltage
AL1
AL2
AX1+AL
AX2+AL
(V)
AC
DC
Current (A)
Voltage
Current (A)
(V)
125
20
20
30
250
20
20
125
0.4
0.05
500
10
250
0.2
0.03
Shunt Trip
UVT
Undervoltage trip
AC
DC
100~110V
125V
200~220V
380~440V
480~550V
24V
48V
100~110V
125V
200~220V
Time rating
Operational voltage
Continuous
100~110V
125V
200~220V
380~440V
Time rating
Operational voltage
Trip voltage
Continuous
85~110% of
control voltage
20~70% of
control voltage
55
30AF ELCB
EBS30c
Ratings
Frame size
30AF
S-Type
2-pole(2-sensor)
3-pole(3-sensor)
EBS33c
EBS34c
4-pole(3-sensor)
Rated current, In
0.1 sec
AC: 220/460V
6kV
Wiring system
2-pole(2-sensor)
3-pole(3-sensor)
4-pole(3-sensor)
S-Type
14 (10)kA
AC 460V
14 (10)kA
415V
30 (25)kA
220/250V
100%
lcs=%Icu
Protective function
400A
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Mounting
Dimensions (mm)
3p
4p
d
a
75
100
a
c1
b
130
130
c1 Note) 2
60
60
c2 Note) 2
64
64
82
Pole
c2
113 page
Trip curves
98 page
Accessories
74 page
Screw fixing
Standard
Weight, kg
Standard
Certification Pole
CE marking
0.9
3p
4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. The short-circuit breaking capacities in ( ) are applied to the rated current in (5, 10A)
4. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
5. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
56
82
0.7
Ordering types
Breaker types
Accessories
EBS type (14kA/460V)
Rated current, In
4-pole
5A
EBS33c/5/30
EBS34c/5/30
10 A
EBS33c/10/30
EBS34c/10/30
15 A
EBS33c/15/30
EBS34c/15/30
20 A
EBS33c/20/30
EBS34c/20/30
30 A
EBS33c/30/30
EBS34c/30/30
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
AX+AL
Combination switch
Maximum possibilities
3-pole
4-pole
5A
EBS33c/5/100
EBS34c/5/100
T-position
Not available
10 A
EBS33c/10/100
EBS34c/10/100
R-position
Option of AX or AL or AX+AL
15 A
EBS33c/15/100
EBS34c/15/100
20 A
EBS33c/20/100
EBS34c/20/100
30 A
EBS33c/30/100
EBS34c/30/100
External accessories
Name
EBS30c
IB13
Insulation barrier
TCL13
TCS13
DH100
DHK100
EH100
RTR1
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
57
50AF ELCB
EBN50c, EBS50c, EBH50c
Ratings
50AF
Frame size
Type and Pole
N-Type
S-Type
2-pole(2-sensor) EBN52c
H-Type
-
- EBS54c EBH54c
15-20-30-40-50A
Rated current, In
0.1 sec
AC: 220/460V
6kV
EBN53c
12W
2-pole(2-sensor)
3-pole(3-sensor)
4-pole(3-sensor)
N-Type
S-Type
H-Type
capacity, Icu
14kA
18kA
50kA
14kA
18kA
50kA
220/250V
30kA
35kA
100kA
AC 460V
415V
lcs=%Icu
Protective function
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Mounting
Dimensions (mm)
2p
3p
3p
4p
3p
4p
d
a
75
75
75
100
90
120
a
c1
b
130
130
155
c1 Note)1
60
60
60
c2 Note)1
64
64
64
82
82
82
Pole
c2
Trip curves
98, 99 page
Accessories
74 page
Screw fixing
Standard
Weight, kg
Standard
Certification Pole
CE marking
0.5
0.7
0.7
0.9
1.2
2p
3p
3p
4p
3p
4p
Note) 1. Depth by door cut size : C1 for large cut, C2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
4. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
58
Ordering types
Breaker types
Accessories
EBN type (14kA/460V)
Rated
current, In
In: 30mA
In: 100/200/500mA
2-pole
3-pole
2-pole
3-pole
15 A
EBN52c/15/30
EBN53c/15/30
EBN52c/15/100
EBN53c/15/100
20 A
EBN52c/20/30
EBN53c/20/30
EBN52c/20/100
EBN53c/20/100
30 A
EBN52c/30/30
EBN53c/30/30
EBN52c/30/100
EBN53c/30/100
40 A
EBN52c/40/30
EBN53c/40/30
EBN52c/40/100
EBN53c/40/100
50 A
EBN52c/50/30
EBN53c/50/30
EBN52c/50/100
EBN53c/50/100
current, In
AX
Auxiliary Switch
AL
Alarm Switch
AX+AL
Electrical auxiliaries
In: 30mA
In: 100/200/500mA
3-pole
4-pole
3-pole
4-pole
15 A
EBS53c/15/30
EBS54c/15/30
EBS53c/15/100
EBS54c/15/100
20 A
EBS53c/20/30
EBS54c/20/30
EBS53c/20/100
EBS54c/20/100
30 A
EBS53c/30/30
EBS54c/30/30
EBS53c/30/100
EBS54c/30/100
40 A
EBS53c/40/30
EBS54c/40/30
EBS53c/40/100
EBS54c/40/100
50 A
EBS53c/50/30
EBS54c/50/30
EBS53c/50/100
EBS54c/50/100
Combination switch
Maximum possibilities
T-position
Not available
R-position
Option of AX or AL or AX+AL
External accessories
3-pole
4-pole
3-pole
4-pole
15 A
EBH53c/15/30
EBH54c/15/30
EBH53c/15/100
EBH54c/15/100
20 A
EBH53c/20/30
EBH54c/20/30
EBH53c/20/100
EBH54c/20/100
30 A
EBH53c/30/30
EBH54c/30/30
EBH53c/30/100
EBH54c/30/100
IB13
IB23
40 A
EBH53c/40/30
EBH54c/40/30
EBH53c/40/100
EBH54c/40/100
TCL13
TCL23
50 A
EBH53c/50/30
EBH54c/50/30
EBH53c/50/100
EBH54c/50/100
TCS13
TCS23
DH100
DH125
EBN50c
EBS50c
EBH50c
Name
Insulation barrier
EH125
RTB2
RTR1
RTR2
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
59
60AF ELCB
EBN60c, EBS60c
Ratings
60AF
Frame size
Type and Pole
2-pole(2-sensor)
3-pole(3-sensor)
N-Type
S-Type
- -
EBN63c
EBS63c
4-pole(3-sensor) -
Rated current, In
0.1 sec
AC: 220/460V
6kV
Wiring system
2-pole(2-sensor)
3-pole(3-sensor)
4-pole(3-sensor)
N-Type
S-Type
capacity, Icu
14kA
18kA
14kA
18kA
AC 460V
415V
220/250V
30kA
35kA
100%
lcs=%Icu
Protective function
Thermal-Magnetic
12In
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Mounting
Pole
113 page
Trip curves
98 page
Accessories
74 page
3p
3p
4p
75
75
100
130
130
130
60
60
60
64
64
64
d
a
c2
a
c1
c1 Note)1
c2 Note)1
82
82
82
Standard
0.7
0.7
0.9
3p
3p
4p
Drawings
Screw fixing
Standard
Dimensions (mm)
100%
EBS63c
EBS64c
60A
Weight, kg
Certification Pole
CE marking
Note) 1. Depth by door cut size : C1 for large cut, C2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
4. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
60
Ordering types
Breaker types
Accessories
EBN type (14kA/460V)
Rated
In: 30mA
In: 100/200/500mA
current, In
60 A
3-pole
3-pole
EBN63c/60/30
EBN63c/60/100
Electrical auxiliaries
AX
Auxiliary Switch
In: 30mA
In: 100/200/500mA
AL
Alarm Switch
3-pole
4-pole
3-pole
4-pole
EBS63c/60/30
EBS64c/60/30
EBS63c/60/100
EBS64c/60/100
AX+AL
Combination switch
Maximum possibilities
T-position
Not available
R-position
Option of AX or AL or AX+AL
External accessories
EBS60c
Name
EBN60c
IB13
Insulation barrier
TCL13
TCS13
DH100
DHK100
EH100
RTB1
RTR1
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
61
100AF ELCB
EBN100c
Ratings
100AF
Frame size
Type and Pole
N-Type
2-pole(2-sensor)
EBN102c
3-pole(3-sensor)
EBN103c
4-pole(3-sensor)
EBN104c
Rated current, In
60-75-100A
30, 100/200/500mA (Adjustable)
0.1 sec
AC: 220/460V
6kV
EBN103c
Wiring system
12W
2-pole(2-sensor)
3-pole(3-sensor)
4-pole(3-sensor)
N-Type
18kA
AC 460V
18kA
415V
220/250V
35kA
lcs=%Icu
100%
Protective function
12In
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Mounting
Dimensions (mm)
Pole
d
a
c2
a
c1
113 page
Trip curves
98 page
Accessories
74 page
2p
3p
4p
75
75
100
c1 Note)1
60 60 60
c2 Note)1
64 64 64
82 82 82
Screw fixing
Standard
Weight, kg
Standard
Certification Pole
CE marking
0.5
0.7
0.9
2p
3p
4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
4. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
62
Ordering types
Breaker types
Accessories
EBN type (18kA/460V)
Rated current, In
3-pole
4-pole
60 A
EBN102c/60/30
EBN103c/60/30
EBN104c/60/30
75 A
EBN102c/75/30
EBN103c/75/30
EBN104c/75/30
100 A
EBN102c/100/30
EBN103c/100/30
EBN104c/100/30
Rated current, In
60 A
Electrical auxiliaries
2-pole
3-pole
4-pole
AX
Auxiliary Switch
EBN102c/60/100
EBN103c/60/100
EBN104c/60/100
AL
Alarm Switch
EBN104c/75/100
AX+AL
75 A
EBN102c/75/100
100 A
EBN103c/75/100
Combination switch
Maximum possibilities
T-position
Not available
R-position
Option of AX or AL or AX+AL
External accessories
EBN100c
IB13
Name
Insulation barrier
TCL13
TCS13
DH100
DHK100
EH100
RTB1
RTR1
Handle Lock
Note) For more detail see 82 pageNote) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
63
125AF ELCB
EBS103c, EBH103c
Ratings
125AF
Frame size
Type and Pole
S-Type
H-Type
2-pole(2-sensor) -
EBS103c
EBH103c
4-pole(3-sensor)
EBS104c
EBH104c
Rated current, In
15-20-30-40-50-60-75-100-125A
AC: 220/460V
6kV
EBS103c
2-pole(2-sensor)
3-pole(3-sensor)
4-pole(3-sensor)
S-Type
H-Type
capacity, Icu
37kA
50kA
37kA
50kA
85kA
100kA
100%
100%
AC 460V
415V
220/250V
lcs=%Icu
Protective function
25000 operations
Mechanical
Electrical
10000 operations
Connection
Front connection
Standard
Rear connection
Optional
Mounting
Pole
99 page
Accessories
74 page
3p
90
120
90
120
155
155
155
c1 Note)1
60
60
60
60
c2 Note)1
64
64
64
64
82
82
82
82
Standard
1.2
1.2
3p
4p
Weight, kg
Certification Pole
CE marking
3p
4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
4. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
64
4p
155
Trip curves
4p
114 page
3p
d
a
c2
a
c1
Drawings
Screw fixing
Standard
Dimensions (mm)
3-pole(3-sensor)
Ordering types
Breaker types
Accessories
EBS type (37kA/460V)
Rated
current, In
In: 30mA
In: 100/200/500mA
3-pole
4-pole
3-pole
15 A
EBS103c/15/30
EBS104c/15/30
EBS103c/15/100 EBS104c/15/100
4-pole
20 A
EBS103c/20/30
EBS104c/20/30
EBS103c/20/100 EBS104c/20/100
30 A
EBS103c/30/30
EBS104c/30/30
EBS103c/30/100 EBS104c/30/100
40 A
EBS103c/40/30
EBS104c/40/30
EBS103c/40/100 EBS104c/40/100
50 A
EBS103c/50/30
EBS104c/50/30
EBS103c/50/100 EBS104c/50/100
AX
Auxiliary Switch
60 A
EBS103c/60/30
EBS104c/60/30
EBS103c/60/100 EBS104c/60/100
AL
Alarm Switch
75 A
EBS103c/75/30
EBS104c/75/30
EBS103c/75/100 EBS104c/75/100
AX+AL
100 A
125 A
In: 30mA
In: 100/200/500mA
3-pole
4-pole
3-pole
Electrical auxiliaries
R
Combination switch
Maximum possibilities
T-position
Not available
R-position
Option of AX or AL or AX+AL
4-pole
15 A
EBH103c/15/30
20 A
EBH103c/20/30
30 A
EBH103c/30/30
40 A
EBH103c/40/30
50 A
EBH103c/50/30
60 A
EBH103c/60/30
75 A
EBH103c/75/30
100 A
125 A
External accessories
EBS125c
Name
EBH125c
IB23
Insulation barrier
TCL23
TCS23
DH125
DHK125
EH125
RTB2
RTR2
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
65
250AF ELCB
Ratings
250AF
Frame size
Type and Pole
N-Type
S-Type
2-pole(2-sensor) EBN202c
H-Type
-
- EBS204c EBH204c
Rated current, In
100-125-150-175-200-225-250A
AC: 220/460V
EBN203c
Wiring system
6kV
2-pole(2-sensor)
12W
3-pole(3-sensor)
4-pole(3-sensor)
N-Type
S-Type
H-Type
capacity, Icu
26kA
37kA
50kA
26kA
37kA
50kA
lcs=100%Icu
220/250V
65kA
85kA
100kA
AC 460V
415V
lcs=%Icu
Protective function
EBS203c
12In
20000 operations
Mechanical
Electrical
5000 operations
Connection
Front connection
Standard
Rear connection
Optional
Mounting
Dimensions (mm)
Pole
d
a
c2
a
c1
Drawings
115 page
Trip curves
100 page
Accessories
74 page
2p
3p
3p
4p
3p
4p
105
105
140
105
140
105
165
165
165
c1 Note)1
60
60
60
c2 Note)1
64
64
64
87
87
87
Screw fixing
Standard
Weight, kg
Standard
1.1
1.2 1.2
1.5 1.2
1.5
Certification Pole
CE marking
2p
3p
3p
4p
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
4. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
66
3p
4p
Ordering types
Breaker types
Accessories
EBN type (25kA/460V)
Rated
current, In
In: 30mA
2-pole
In: 100/200/500mA
3-pole
2-pole
3-pole
100 A
125 A
150 A
175 A
200 A
225 A
250 A
AX
Auxiliary Switch
AL
Alarm Switch
AX+AL
current, In
In: 30mA
In: 100/200/500mA
3-pole
4-pole
Combination switch
Maximum possibilities
Electrical auxiliaries
3-pole
4-pole
100 A
125 A
150 A
175 A
200 A
225 A
250 A
T-position
Not available
R-position
Option of AX or AL or AX+AL
External accessories
EBH type (50kA/460V)
Rated
current, In
4-pole
3-pole
4-pole
100 A
125 A
150 A
175 A
200 A
225 A
250 A
EBN250c
EBS250c
EBH250c
IB23
Name
Insulation barrier
TCL33
TCS33
DH250
DHK250
EH250
RTB3
RTR3
Handle Lock
Note) For more detail see 82 page
Inde type: This cover is used without auxiliary Handle.
D-Handle type: This cover is used with D-Handle.
N-Handle type: This cover is used with N-Handle.
67
400AF ELCB
EBN400c, EBS400c, EBH400c, EBL400c
Ratings
400AF
Frame size
Type and Pole
N-Type
EBS403c
EBH403c
EBL403c
EBS404c
EBH404c
EBL404c
250-300-350-400A
30, 100/200/500mA (Adjustable)
0.1 sec
220/460V
6kV
3-pole(3-sensor)
4-pole(3-sensor)
Rated short-circuit breaking
capacity, Icu
AC 415/460V 37kA
50kA
65kA
85kA
220/250V 50kA
75kA
85kA
125kA
100%
100%
100%
Thermal-Magnetic
8~12In
Electrical
1000 operations
Connection
Standard
Front connection
Mounting
Standard
Screw fixing
Pole
d
a
c2
a
c1
Trip curves
101 page
Accessories
75 page
3p 4p
3p 4p
3p 4p 3p 4p
c1 Note)1
c2 Note)1
116 page
4000 operations
Mechanical
Dimensions (mm)
Drawings
Weight, kg
Certification Pole
CE marking
3p 4p
3p 4p 3p
3p
- - - -
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. 4-Pole products ampacity on neutral conductor is equal to or less than 50% of the rated current.
4. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
68
75%
L-Type
3-pole(3-sensor) EBN403c
Rated current, In
EBL404c
H-Type
4-pole(3-sensor) EBN404c
EBS403c
S-Type
Ordering types
Breaker types
Accessories
EBN type (25kA/460V)
Rated
current, In
In: 30mA
3-pole
In: 100/200/500mA
4-pole
3-pole
4-pole
250 A
300 A
350 A
400 A
In: 30mA
In: 100/200/500mA
3-pole
4-pole
3-pole
4-pole
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
250 A
SHT
Shunt Trip
300 A
UVT
Undervoltage trip
350 A
400 A
In: 30mA
In: 100/200/500mA
3-pole
4-pole
3-pole
Maximum possibilities
T-position
Not available
R-position
4-pole
250 A
300 A
350 A
400 A
In: 30mA
In: 100/200/500mA
3-pole
4-pole
3-pole
4-pole
250 A
300 A
350 A
400 A
E-70U
N-70
External accessories
IBL400
Insulation barrier
T1-43A
T1-44A
N-70
E-70U
MI-43
MI-44
69
800AF ELCB
Ratings
800AF
Frame size
Type and Pole
N-Type
S-Type
L-Type
3-pole(3-sensor) EBN803c
EBS803c
EBL803c
4-pole(3-sensor) -
500-630-700-800A
Rated current, In
0.1 sec
220/460V
6 kV
3-pole(3-sensor)
4-pole(3-sensor)
Rated short-circuit breaking
capacity, Icu
65kA
85kA
85kA
125kA
100%
100%
75%
Protective function
8~12In
Electrical
Trip curves
101 page
Accessories
75 page
500 operations
Standard
Front connection
Mounting
Standard
Screw fixing
Pole
3p
d
a
c2
a
c1
210
280
c1 Note)1
109
c2 Note)1
113
145
11.5
117 page
2500 operations
Connection
Dimensions (mm)
Drawings
220/250V 50kA
lcs=%Icu
AC 415/460V 37kA
Endurance
Weight, kg
Standard
Certification Pole
CE marking
3p
-
Note) 1. Depth by door cut size : c1 for large cut, c2 for small cut
2. Do not test withstand voltage or insulation resistance test between poles to avoid the damage of the PCB.
3. Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
70
Ordering types
Accessories
Breaker types
EBN type (37kA/460V)
Rated
current, In
3p
3p
500 A
EBN803c/500/30 EBN803c/500/100
630 A
EBN803c/630/30 EBN803c/630/100
700 A
EBN803c/700/30 EBN803c/700/100
800 A
EBN803c/800/30 EBN803c/800/100
3p
3p
500 A
EBS803c/500/30 EBS803c/500/100
630 A
EBS803c/630/30 EBS803c/630/100
700 A
EBS803c/700/30 EBS803c/700/100
800 A
EBS803c/800/30 EBS803c/800/100
Electrical auxiliaries
AX
Auxiliary Switch
AL
Alarm Switch
SHT
Shunt Trip
UVT
Undervoltage trip
Maximum possibilities
T-position
Not available
R-position
3p
3p
500 A
EBL803c/500/30 EBL803c/500/100
630 A
EBL803c/630/30 EBL803c/630/100
700 A
EBL803c/700/30 EBL803c/700/100
800 A
EBL803c/800/30 EBL803c/800/100
E-80U
N-80
External accessories
IBL800
Insulation barrier
T1-63A
T1-64A
N-80
E-80U
MI-83S
MI-84S
71
1000/1200AF ELCB
EBS1003b, EBS1203b
Ratings
1000AF
Frame size
S-Type
S-Type
3-pole(3-sensor) EBS1003b
EBS1203b
4-pole(4-sensor) -
1000A
1200A
Rated current, In
100/200/500mA (Adjustable)
0.1 sec
AC: 460V
S-Type S-Type
AC 415/460V
85kA
220/250V
125kA
3~6In ...
3-pole(3-sensor)
Mechanical
Electrical
Adjustable instantaneous
for each phase
1200AF
2500operations
500operations
Connection
Standard
Front connection
Mounting
Standard
Screw fixing
Dimensions (mm)
Pole
220
565
105
159
Weight, kg
27.1
118 page
Trip curves
102 page
Standard
Note) Rated non-trip current sensitivity is equal to or less than 50% of the rated current sensitivity.
72
3p
d
c2
a
a
c1
Ordering types
Breaker types
MCCB
ON
OFF
TRIP
Rated current, In 3p
1000 A
EBS1003b/1000/100
1200 A
EBS1203b/1200/100
AX
AL
AL1
Voltage
AX1+AL1
(V)
AC
DC
Current (A)
Voltage
Current (A)
(V)
125
20
20
30
250
20
20
125
0.4
0.05
500
10
250
0.2
0.03
73
Accessories
SHT
Shunt Trip
AX
UVT
Auxiliary
Switch
Undervoltage
trip
AL
Left-hand seat
Right-hand seat
Alarm Switch
AX
Auxiliary
Switch
AX+AL
AL
Alarm
Switch
Combination switch
AX+AL
Combination
switch
Maximum possibilities
Position
Left-hand
seat
74
Type
ABN100c
ABH125c
2p 3/4p 2p
ABH250c
EBN100c
EBH125c
EBH250c
3/4p
2/3/4p
2/3/4p
3/4p
2/3/4p
AX
AL
AX+AL
AX
Right-hand
AL
seat
AX+AL
SHT/UVT 1
AL AL
AL AL
Alarm Switch
Alarm Switch
SHTSHT
SHTSHT
Shunt Trip
Shunt Trip
UVTUVT
UVTUVT
Undervoltage trip
Undervoltage trip
AX AX
AX AX
Auxiliary Switch
Auxiliary Switch
Option of connecting
AX or AL or AX+AL
This seat is not available for 2-pole breakers.
Option of connecting
SHT or UVT or AX or AL or AX+AL
This seat is not available for ELCB.
Maximum possibilities
Position
Left-hand
seat
Right-hand
seat
MCCB
ELCB
(400~800AF)
(400~800AF)
AX
AL
SHT/UVT
AX
AL
SHT/UVT
Type
75
Accessories
Combinations of accessories
Right-hand
seat
Main breaker
Left-hand
seat
Series
S-Type
Type
H-Type
L-Type
Pole
AX
AX2
AX3 (4)
AL
AL2
AL3(4)
SHT(UVT)
SHT(UVT)2
AX+AL
AX+AL2
AX+AL3(4)
AX2+AL
AX2+AL2
AX2+AL3(4)
AX3(4)+AL
AX3(4)+AL2
AX3(4)+AL3(4)
AX+SHT(UVT)
MCCB (30~250AF)
N-Type
76
ABE 32b
2 Pole
MCCB (400~800AF)
ABN 53c/54c
ABN 52c
ABN 63c/64c
ABN 402c/403c/404c
ABE 33b
ABN 62c
ABN 103c/104c, ABN 103d/104d
ABN 802c/803c/804c
ABN 102c/102d
ABN 202c/203c/204c
ABS 33c/34c
ABS 32c
ABS 53c/54c
ABS 402c/403c/404c
ABS 52c
ABS 63c/64c
ABS 802c/803c/804c
ABS 62c
ABS 103c/104c
ABS 102c
ABS 202c/203c/204c
ABH 53c/54c
ABH 52c
ABH 103c/104c
ABH 402c/403c/404c
ABH 102c
ABH202c/203c/204c
ABL 402c/403c/404c
ABL 802c/803c/804c
2 Pole
3 Pole
2, 3, 4 Pole
2, 3, 4 Pole
MCCB (1000~1200AF)
ABS 1003b
ABS 1004b
ABS 1203b
ABS 1204b
ABS 1203bE
ABL 1003b
ABL 1004b
ABL 1203b
ABL 1204b
3, 4 Pole
Right-hand
seat
Main breaker
Left-hand
seat
Series
MCCB (30~250AF)
N-Type
S-Type
Type
H-Type
L-Type
Pole
ABE 32b
2 Pole
MCCB (400~800AF)
ABN 53c/54c
ABN 52c
ABN 63c/64c
ABN 402c/403c/404c
ABN 62c
ABE 33b
ABN 103c/104c
ABN 802c/803c/804c
ABN 102c
ABN 202c/203c/204c
ABS 33c/34c
ABS 32c
ABS 53c/54c
ABS 402c/403c/404c
ABS 52c
ABS 63c/64c
ABS 802c/803c/804c
ABS 62c
ABS 103c/104c
ABS 102c
ABS 202c/203c/204c
ABH 53c/54c
ABH 52c
ABH 103c/104c
ABH 402c/403c/404c
ABH 102c
ABH202c/203c/204c
ABL 402c/403c/404c
ABL 802c/803c/804c
3 Pole
2, 3, 4 Pole
2, 3, 4 Pole
2 Pole
MCCB (1000~1200AF)
ABS 1003b
ABS 1004b
ABS 1203b
ABS 1204b
ABS 1203bE
ABL 1003b
ABL 1004b
ABL 1203b
ABL 1204b
3, 4 Pole
AX+SHT(UVT)2
AX2+SHT(UVT)
AX2+SHT(UVT)2
AX3(4)+SHT(UVT)
AX3(4)+SHT(UVT)2
AL+SHT(UVT)
AL+SHT(UVT)2
AL2+SHT(UVT)
AL2+SHT(UVT)2
AL3(4)+SHT(UVT)
AL3(4)+SHT(UVT)2
AX+AL+SHT(UVT)
AX+AL+SHT(UVT)2
AX2+AL2+SHT(UVT)
AX2+AL2+SHT(UVT)2
AX3(4)+AL3(4)+SHT(UVT)
AX3(4)+AL3(4)+SHT(UVT)2
77
Accessories
Combinations of accessories
Right-hand
seat
Main breaker
Left-hand
seat
Left-hand
seat
Right-hand
seat
Main breaker
Series
ELCB (30~250AF)
Pole
AL
AL2
SHT(UVT)
AX+AL
AX+AL2
AX2+AL
AX2+AL2
AX+SHT(UVT)
AX2+SHT(UVT)
AL+SHT(UVT)
AL2+SHT(UVT)
AX+AL+SHT(UVT)
AX2+AL2+SHT(UVT)
78
ELCB (1000~1200AF)
EBN 52c/53c/54c
EBN 63c
EBN 403c/404c
N-Type
EBN 102c/103c/104c
EBN 803c
EBN 202c/203c
EBS 33c/34c
EBS 53c/54c
EBS 403c/404c
EBS 1003b
S-Type
EBS 63c/64c
EBS 803c
EBS 1203b
EBS 103c/104c
Type
EBS 203c/204c
EBH 53c/54c
H-Type
EBH 53c/54c
EBH 403c/404c
EBH 103c/104c
L-Type
EBL 403c/404c
EBL 803c
AX2
Note) 1. When you touch the lead wire under energized condition,
you will be in danger of electric shock.
2. Do not energize on both ends of lead wire.
3. Do not pull out the lead wire excessively or impact on the
product.
AX
Test button
3, 4 Pole
3 Pole
3 Pole
Contact (AX+AL)
MCCB
ON
OFF
TRIP
AX
AL
Rating (AX+AL)
Conventional thermal current, Ith
5A
AC 50/60Hz
DC
Current, Ie
Voltage, Ue
Resistive
load
Inductive
load
125V
250V
500V
30V
Minimum
laod current
Applicable
MCCB/ELCB
5V DC 160mA
Metasol MCCB/ELCB
30V DC 30mA
30~800AF
125V
0.4
0.4
250V
0.2
0.2
79
Accessories
Control voltage, Ue
AC (VA)
DC (W)
1.5
AC/DC 24~30V
1.5
1.5
AC/DC 48~60V
1.5
1.5
AC/DC 100~130V
1.5
1.5
AC/DC 200~250V
1.5
1.5
AC 380~450V
1.5
AC 440~500V
1.5
DC 12V
Voltage
Terminal block type (TBT)
Max.opening time
50ms (max.)
Tightening torque of
terminal screw
8.2 kgfcm
MCCB/ELCB
Metasol MCCB
ABN100c
ABH125c
ABH250c
80
Power consumption
V mA W
AC/DC 24~48
AC 24
14
0.3
AC 100~240/DC 100~220
DC 24
15.4
0.4
AC 380~550
AC 48
14
0.7
DC 48
16
0.8
AC 110
0.7
DC 110
6.6
0.7
AC 220
6.8
1.5
DC 200
7.6
1.5
AC 440
4.3
1.9
AC 480
4.4
3.3
AC 550
4.6
2.4
Voltage
Power consumption
AC (VA)
DC (W)
mA
AC/DC 24V
0.64
0.65
27
AC/DC 48V
1.09
1.1
23
AC/DC 100~110V
0.73
0.75
5.8
AC/DC 200~220V
1.21
1.35
5.4
AC 380~440V
1.67
3.8
AC 440~480V
1.68
3.5
Max.opening time
50ms (max.)
Trip
voltage range
Reset/Closing
8.2 kgfcm
20~70% Vn
0.85Vn
Trip voltage
Reset/closing voltage
Time rating
AC/DC 48
AC/DC 100~125
AC 200~240 / DC 200~240
AC 380~440
AC: 85~1.1Vn
AC: 0.2~0.7Vn
DC: 85~1.25Vn
DC: 0.2~0.7Vn
Continuous
AC 440~480
Terminal numbering
Auxiliary Switch (AX)
81
Accessories
External accessories
Wide range of external accessories provides user-friendly solution for mounting, cable connection, insulation, safety lock and remote control.
Insulation barrier
Terminal cover
Rear terminal
Breaker
Rotary handle
(Direct, Key lock)
Rear terminal
Plug-in kit
Rotary handle
(Extended)
Terminal cover
Insulation barrier
82
Rotary handles
Direct type
Direct type
(DH 30~250AF)
Key lock
(DH 30~250AF)
(N 30~250AF)
The rotary handle operating mechanism is available in either the direct version or in the extended version on the
compartment door. It is always fitted with a compartment door lock and on a request it can be supplied with a
key lock in the open position.
Direct type , D-handle and N-handle
-D-Handle : Directly mountable to a circuit breaker. Trip button is built as standard. Key lock type is optional.
-N-Handle : Directly mountable to a circuit breaker. Door is locked in the Off state. Handle size is greater than D-Handle.
Extended type, E-Handle
It is used in case direct type handle can not be applied because of the longer distance between the breaker and
the panel door.
Type
Direct type
Direct type
Breaker type
Extended type
(Key lock)
MCCB
N-30c
DH100
DHK100
N-40c
DH125
DHK125
ELCB
ABN50c/60c/100c EBN50c/60c/100c
EH100
ABS30c/50c/60c EBS30c/50c/60c
-
EH125
ABS125c EBS125c
ABH50c/125c EBH50c/125c
N-50c - -
ABN/S/H250c
EBN/S/H250c
DH250 DHK250 EH250
N-70
E-70U
ABN/S/H/L400c EBN/S/H/L400c
N-80
E-80U
ABN/S/L630c/800c EBN/S/L630c/800c
(N 400~800AF)
Extended type
L-Type
LINE
R-Type
LOAD
LOAD
LINE
(30~250AF)
LOAD
ON
ON
(400~800AF)
83
Accessories
D-handle
MCCB and D-handle
ABN100c
ABH125c
ABH250c
Tripped
Push to trip
L-Type
S-Type
R-Type
LINE
LINE
LINE
LOAD
LOAD
LOAD
ON
84
ON
ON
ABN100c, EBN100c
ABH125c, EBH125c
ABH250c, EBH250c
Cutting Panel
D (mm)
E (mm)
Breaker
90
92
103.4
100AF
105
108
120
125AF
110
122
250AF
D-Handle
A (mm)
B (mm)
C (mm)
DH100
110.5
78
DH125
132
94
DH250
126
108
121
85
Accessories
LOCKED
D-handle
UNLOCKED
OFF position
Operating
Test
Remove
the key if you operate the handle.
CAUTION
If the door is opened with
much pressure when the
position of handle is ON or
TRIP, the handle lock lever
will be demaged.
ON
Reset
Tripped
OFF
PUSH TO
TRIP
Locking System
Releasing (at ON position)
KEY LOCK
LOCKED
UNLOCKED
OFF position
Releasing
86
E-handle
MCCB and E-handle
ABN100c
ABH125c
ABH250c
Tripped
Push to trip
L-Type
S-Type
R-Type
LINE
LINE
LOAD
LOAD
LINE
LOAD
ON
ON
ON
87
Accessories
E-handle
Installing the E-handle
ABN100c, EBN100c
ABH125c, EBH125c
ABH250c, EBH250c
Cutting Panel
E-Handle
A (mm)
C (mm)
Breaker
EH100
47
53
100AF
EH125
47
53
125AF
EH250
47
53
250AF
Note: An extension shaft that must be adjusted to the distance between back of circuit breaker and door
88
B (mm)
LOCKED
UNLOCKED
OFF position
Operating
Test
Remove
the key if you operate the handle.
CAUTION
If the door is opened with
much pressure when the
position of handle is ON or
TRIP, the handle lock lever
will be demaged.
Reset
ON
OFF
Locking System
Releasing (at ON position)
Releasing
89
Accessories
N-handle
How to mount
1) Drilling on the panel door
All the N handles require the same size of
mounting hole.
Drill the holes according to the Fig. 1
(N-70, N-80)
Mounting base
Dimension A
N-30c :103
N-40c : 103
N-50c : 103
* S : Vertical mounting
<Fig 1>
(N-70, N-80)
Mounting base
Mounting base
Dimension A
N-30c :103
N-40c : 103
N-50c : 103
<Fig 2>
Mounting base
(3) Fixing
Fixing a breaker and a handle at the same
time.
a) As shown in the Fig. 3 a breaker and
a handle can be fixed at the same time
on a mounting base with the 4 (long)
screws enclosed.
(N-70, N-80)
<Fig 3>
lever of lever of
N handleN handle
breaker breaker
handle handle
(N-70, N-80)
<Fig 4>
90
<Fig 5>
locking plate
door
front plate
<Fig 6>
Bad-tilt
<Fig 7>
<Fig 8>
adjusting screw
locking lever
<Fig 9>
b) In the event the door does not lock after closing the door
This happens if the distance between the door panel and
the mounting base the panels of the door is long.
Loosen the adjusting screw in the lock plate and move the
plate in the direction of the arrow as shown in Fig. 10.
<Fig 10>
91
Accessories
N-handle
(1) Operation in the door closed
To have the breaker ON turn the handle to be vertical. <Fig. 11>
To have the breaker OFF turn the handle to be horizontal. <Fig. 12>
If the breaker is tripped, the handle points to the TRIP position.
To reset the breaker turn the handle to Reset position.
<Fig 11>
<Fig 12>
Release
screw
Release
screw
<Fig 13>
Padlocking
Lockable at ON or OFF state with a padlock. (Padlock is not supplied)
- Lockable at OFF state with a padlock is an optional spec.
Pull the lock plate on the front of the handle and fasten the lock. <Fig. 15>
If the breaker is tripped after padlocking at ON state, the handle will point to
the TRIP.
Padlock diameter should be 3.5 ~ 6mm
(N-70, N-80)
<Fig 14>
<Fig 15>
92
Terminal covers
The terminal covers are applied to the circuit-breaker to prevent accidental contact with live parts and thereby guarantee protection
against direct contacts.
Two types by length are available and provide IP20 degree of protection.
Also, covers ara classified in to 2 different type: Independent, Attachable and detachable with D or N Handle
Short type covers, TCS:
For fixed circuit-breakers with rear terminals and for moving parts of plug-in.
Long type covers, TCL:
For fixed circuit-breakers with front, front extended, front for cables terminals.
Terminal covers
Short Type
Inde D-Handle
N-Handle
Long Type
Inde D-Handle
Applied breaker
Pole
N-Handle
TBS22
2P
TBS23
3P
TCS12
TCL12
2P
TCS13
TCS13
TCS13
TCL13
TCL13
TCL13
3P
TCS14
TCS14
TCS14
TCL14
TCS14
TCS14
4P
TCS22
TCL22
2P
TCS23
TCS23
TCL23
TCL23
3P
TCS24
TCS24
TCL24
TCL24
4P
TCS33
TCS33
TCL33
TCL33
2, 3P
TCS34
TCS34
TCL34
TCL34
4P
T1-43A
T1-44A
T1-63A
T1-64A
-
-
MCCB
ELCB
ABE30b
Size extended(A),
mm
Short Type Long Type
ABN50c/60c/100c EBN50c/60c/100c
ABS30c/50c/60c
EBS30c/50c/60c
ABS125c
EBS125c
ABH50c/125c EBH50c/125c
ABN250c, ABS250c EBN250c, EBS250c
ABH250c
EBH250c
2, 3P
ABN/S/H/L400c EBN/S/H/L400c
4P
2, 3P
4P
ABN/S/L/800c EBN/S/L/800c
10 -
5.5 30
5.5 40
5.5
50
- 120
- 141
Note: Terminal covers for 400AF and 800AF MCCBs are in acrylic.
TCS(Short type)
TCL(Long type)
93
Accessories
Insulation barriers
Insulation barrier allows the insulation characteristics between the phases at the connections to be increased.
They are mounted from the front, even with the circuit-breaker already installed, inserting them into the
corresponding slots.
They are incompatible with both the insulating terminal covers.
It is possible to mount the phase separating partitions between two circuit-breakers side by side.
Breaker
Type
MCCB
IB-13
ABN50c/60c/100c EBN50c/60c/100c
ABS30c/50c/60c EBS30c/50c/60c
ABS125c EBS125c
IB-23
ABH50c/125c EBH50c/125c
ABN250c, ABS250c EBN250c, EBS250c
ABH250c EBH250c
IBL400
ABN/S/H/L400c EBN/S/H/L400c
IBL800
ABN/S/L800c EBN/S/L800c
94
ELCB
Breaker
For 2-pole
For 3-pole
For 4-pole
ABN100c 50AF
RTR1-52
RTR1-53
ABN100c 100AF
RTR1-102
RTR1-103
RTR1-104
ABH125c
ABH250c
CL
Breaker
For 2-pole
For 3-pole
For 4-pole
ABN100c
ABH125c
ABH250c
CL
CL
95
Accessories
Mechanical interlock
The mechanical interlock is installed on the front of two breakers mounted side by side, in either the 3-pole or 4-pole version
and prevents simultaneous closing of the two breakers. So it is suitable for consisting of manual sourcechangeover system.
MI
Type
AF
Pole
Mechanical
interlock
1 100AF
2 125AF
3 250AF
4 400AF
8 800AF
3 3P
4 4P
MCCB
ELCB
MI-13, 14
MI-23, 24
MI-33, 34
MI-43, 44
MI-83, 84
Layout
Padlock dimensions
Narrow cutting
Cutting
96
MI-13, 14
MI-23, 24
MI-33, 34
MI-43, 44
A B
A B
A B
A B A B
MI-83, 84
Narrow
Wide
Breaker
3P
4P
100AF
125AF
250AF
400AF
800AF
25
30
35
44
70
25 110.5
30 132
35 126
44 215
70 243
3P
4P
3P
4P
110.5
132
126
215
243
70
84
99
166
210
95
114
134
210
280
Plug-in devices
Plug-in device makes it possible to extract and/or rapidly replace the circuit breaker without having to touch
connections for ship and important installations.
The plug-in base is the fixed part of the plug-in version of the circuit-breaker.
It will be installed directly on the back plate of panel.
The circuit-breaker is racked out by unscrewing the top and bottom fixing screws.
Plug-in base
Arrangement
ABN100c
ABH125c
P lug-in block
Normal
PB-A3-FR
Single-row
PB-A3-1DB
Double-row
PB-A3-2DB
Line-only
PB-A3-FRL
Normal
PB-C3-FR
Single-row
PB-C3-1DB
Double-row
PB-C3-2DB
Line-only
PB-C3-FRL
ABH250c
Normal
PB-D3-FR
400AF
Normal/Line-only
PB-I3-FR/PB-I3-FRL
800AF
Normal
PB-J3-FR
Normal
Remark
Double-row
97
MCCB
AB
10
MCCB
Type
Ampere Frame
Pole
Series
N N-Type
S S-Type
H H-Type
L L-Type
3 30AF
5 50AF
6 60AF
10 100/125AF
20 225/250AF
40
400AF
80 800AF
100 1000AF
120 1200AF
/ 100A
Application
Rated current
General
purpose
Motor
M
protection
2 2-pole
3 3-pole
4 4-pole
Accessory
Rated current
3A
5A
10A
15A
20A
30A
40A
50A
60A
75A
100A
125A
150A
150A
175A
200A
225A
250A
300A
350A
400A
500A
630A
700A
800A
1200A
AX
AX Auxiliary Switch
AL Alarm Switch
SHT Shunt Trip
Undervoltage
UVT
trip
Rotary handle
DH
(Direct)
Rotary handle
EH
(Extended)
RTR
Rear terminal
RTB
SHT=220V
Control voltage
of accessory
SHT
AC/DC 12V
AC/DC 24V
AC/DC 48V
AC/DC 60V
AC/DC
100V~130V
AC/DC
200V~250V
AC 380V~450V
AC 440V~500V
UVT
AC/DC 24V
AC/DC 48V
AC/DC
100V~110V
AC/DC
200V~220V
AC 380V~440V
AC 440V~480V
* Warning: Mounting accessories is not available at the left side of 2pole MCCB (Up to 125AF)
ELCB
EB
ELCB
10
Type
N N-Type
S S-Type
H H-Type
L L-Type
Ampere Frame
Pole
Series
3 30AF
5 50AF
6 60AF
10 100/125AF
20 225/250AF
40
400AF
80 800AF
100 1000AF
120 1200AF
2 2-pole
3 3-pole
4 4-pole
* Warning: Mounting accessories is not available at the right side ELCB (Up to 250AF)
98
/ 100A
Rated current
15A
20A
30A
40A
50A
60A
75A
100A
125A
150A
175A
200A
225A
250A
300A
350A
400A
500A
630A
700A
800A
1000A
1200A
30mA
AX
Rated residual
Accessory
current
AX Auxiliary Switch
AL Alarm Switch
30mA
100/200/500mA Rotary handle
DH
(Direct)
Rotary handle
EH
(Extended)
RTR
Rear terminal
RTB
Position & Type
Left Lead
R LWT Side
Wire
Mounting Type
Left
Terminal
R TBT Side
Block
Mounting Type
Characteristics curves
Breaker types
Compensation curves
ABE30b
Min.
MCCB
ABE30b
Ambient temp. 40
Operational time
Max.
MCCB
ABN50c/60c/100c/100d
ABS30c/50c/60c
ELCB
EBN50c/60c/100c
EBS30c/50c/60c
Sec.
Compensation curves
ABN/S, EBN/S
Breaker types
Min.
Ambient temp. 40
Min.
Min.
Rated current
Max.
Operational time
Operational time
Max.
Min.
Sec.
Sec.
Min.
Rated current
Rated current
99
Characteristics curves
Breaker types
MCCB
ABS125c
Min.
ABH50c/125c
ELCB
EBS125c
EBH50c/125c
Operational time
Max.
Sec.
Min.
Rated current
Min.
Operational time
Max.
Ambient temp. 40
Min.
Ambient temp. 40
100
Sec.
Compensation curves
Rated current
Breaker types
MCCB
ABN250c, ABS250c
ABH250c
Min.
ELCB
EBN250c, EBS250c
EBH250c
Operational time
Max.
Sec.
Min.
Rated current
40
100
20
10
8
6
4
50
10
20
30
40
50
Max.
1
Operational time
Ambient temp. 40
40
20
10
8
6
Min.
4
2
Sec.
240
180
150
120
100
80
60
150
Min.
Compensation curves
1
0.8
0.6
0.4
Magnetic trip
range
(960~1440%)
0.2
100
0.1
0.08
0.06
0.04
50
0.02
10
20
30
40
Ambient temp. 40
50
0.01
1
1.5
6 7 8 9 10
15
20
30
40
50 60
80 100
Rated current
101
Characteristics curves
Breaker types
MCCB
ABN400c, ABS400c, ABH400c, ABL400c
ABN800c, ABS800c, ABL800c
Min.
ELCB
EBN400c, EBS400c, EBH400c, EBL400c
EBN800c, EBS800c, EBL800c
Operational time
Max.
Sec.
Min.
Rated current
240
180
150
120
60
40
Min.
100
10
20
30
40
Max.
40
20
10
8
6
Min.
4
2
Sec.
10
8
6
50
Ambient temp. 40
1
0.8
0.6
0.4
0.2
100
0.1
0.08
0.06
(800~1200%)
Max. breaking time
0.04
50
0.02
10
20
30
40
Ambient temp. 40
102
20
50
Operational time
Compensation curves
50
0.01
1 1.25
6 7 8 9 10
15
20
Rated current
30
40 50
70
100
Breaker types
MCCB
ABS1000b, ABL1000b
ABS1200b, ABL1200b
Min.
ELCB
EBS1003b, EBS1203b
Max.
Sec.
Compensation curves
Operational time
Min.
Ambient temp. 40
Rated current
Breaker types
MCCB
Operational time
Sec.
Min.
Hou.
ABS1200bE
Rated current
103
Characteristics curves
Motor Protection type
Breaker types
MCCB
ABN50cM/60cM/100cM/100dM
Max.
Max.
Sec.
Min.
Sec.
Operational time
Operational time
Min.
ABS30cM/50cM/60cM
Rated current
Rated current
104
Min.
16A~32A
16A~32A
45A~90A
45A~90A
Min.
Max.
Sec.
Ambient temp . 40
Ambient temp . 40
Operational time
Operational time
Min.
Max.
Sec.
Rated
current
compensation
rate
(%)(%)
Rated
current
compensation
rate
Rated
current
compensation
rate
(%)(%)
Rated
current
compensation
rate
Compensation curves
Ambient temp . 40
Ambient temp . 40
Rated current
Rated current
Breaker types
MCCB
240
180
150
120
100
80
60
ABS125cM
ABH50cM/125cM
Min.
40
20
10
8
6
4
2
Max.
1
16A~32A
Operational time
20
10
8
6
Min.
4
2
Sec.
Compensation curves
40
1
0.8
0.6
0.4
0.2
45A~90A
0.1
0.08
0.06
0.04
0.02
0.01
Ambient temp . 40
1.5
6 7 8 9 10
15
20
30
40
50 60
80 100
Rated current
Breaker types
MCCB
ABN250cM, ABS250cM
ABH250cM
Compensation curves
Rated current: 125~225A
Ambient temp. 40
105
Dimensions
MCCB
ABE30b
(mm)
Terminal cover
Insulation barrier
Terminal cover
Terminal cover
Insulation
barrier
Terminal cover
Insulation
barrier
Fixing hole
Terminal cover
Insulation barrier
Terminal cover
DIN-Rail
Fixing hole
Terminal cover
Insulation barrier
Terminal cover
Terminal cover
Insulation
barrier DIN-Rail
Fixing hole
DIN-Rail
2P
3P
Trip test button
Terminal details
(Screw)
(Screw)
(Screw)
(Screw)
Panel drilling
(Screw)
(Screw)
(Holder)
(Holder)
(Holder)
(Holder)
(Holder)
106
(Holder)
3P
MCCB
ABN50c
ABS30c
ABN60c
ABS50c
ABN100c/100d
ABS60c
(mm)
25
25
56
50
13.3
25
50
13.3
50
130
13.3
58
25
75
50
84
115
19
115
130
50
84
19
19
22
115
130
22
50
84
22
75
60
64
100
2P
4.5
7.4
50
50
50
Insulation barrier
Insulation barrier
Insulation barrier
25
3P
68
82
4P
7.5
15
5.
M514
12.5
Connecting
8.2
Terminal details
18
24
( 50A)
(60A)
M814
7.5
8.2
( 50A)
18
24
(60A)
Panel drilling
25
2P
3P
25
4P
52
52
52
110.5
M4 or5
110.5
M4 or5
110.5
M4 or 5
52
77
102
2P
3P
4P
107
Dimensions
MCCB
ABS125c
ABH50c
ABH125c
(mm)
30
80
80
Fixing hole
50
50
80
Insulation barrier
Insulation barrier
Fixing hole
Fixing hole
30
50
Insulation barrier
30
37
37
8.2
50
155
135
16.5
50
155
135
100
22
16.5
50
155
135
100
50
16.5
22
100
22
37
60
8
60
90
30
10
10
30
10
90
58
8
60
82
120
2P
3P
4P
Connecting
M814
16
Terminal details
24
10
Panel drilling
108
3P
30
4P
62
92
2P
3P
52
132
132
30
2P
M4 or5
52
M4 or5
132
M4 or5
52
18
122
4P
MCCB
ABN250c
ABS250c
ABH250c
(mm)
Insulation barrier
Insulation barrier
Fixing hole
Fixing hole
2,3P
4P
Terminal details
Connecting
Panel drilling
M4 or5
2,3P
4P
2,3P
4P
109
Dimensions
MCCB
ABN400c
ABS400c
ABH400c
ABL400c
(mm)
In
Fixing hole
Fixing hole
Fixing hole
2P
3P
Terminal details
4P
Connecting
Panel drilling
M6 or6
142(3p)
187(4p)
142(3p)
187(4p)
3, 4P
3, 4P
M6 or6
Slot "A"
Slot "B"
Slot "C"
2, 3P
110
4P
2, 3, 4P
MCCB
ABN630c
ABS630c
ABL630c
ABN800c
ABS800c
ABL800c
(mm)
34.5
73.5
73.5
73.5
73.5
2P
3P
4P
630AF : 7
800AF : 10
Connecting
Terminal details
Panel drilling
<AUX.Cover>
C
212(3P)
282(4P)
212(3P)
282(4P)
Panel
Cover A
Panel
Cover B
Panel
Cover C
2, 3P
4P
2, 3, 4P
3, 4P
3, 4P
111
Dimensions
MCCB
ABS1000b
ABL1000b
ABS1200b
ABL1200b
(mm)
Mounting hole
Mounting hole
Mounting hole
Mounting hole
Auxiliary handle
Auxiliary handle
3P
4P
or
or
Panel drilling
or
3P
112
4P
3P
4P
MCCB
ABS1203bE
(mm)
Mounting hole
Mounting hole
Auxiliary handle
Auxiliary handle
or
Panel drilling
113
Dimensions
ELCB
EBN50c
EBS30c
EBN60c
EBS50c
EBN100c
EBS60c
(mm)
25
25
25
Insulation barrier
56
13.3
13.3
25
75
100
2,3P
58
60
64
4P
66.5
68
Terminal details
82
Connecting
( 50A)
( 50A)
(60A)
(60A)
Panel drilling
M4 or5
2, 3P
114
4P
2P
3P
4P
4.5
50
29.2
19
19
29.2
7.4
Residual current
(In) setting
50
Residual current
(In) setting
84
Trip indication
by earth fault
115
Trip indication
by earth fault
130
50
84
115
130
2.2
50
50
Insulation barrier
ELCB
EBS125c
EBH50c
EBH125c
(mm)
30
30
Insulation barrier
Fixing hole
Fixing hole
50
50
80
80
Insulation barrier
37.8
4.7
37
10
2.5
4
50
Residual current
(In) setting
16.5
50
100
155
4.7
135
Residual current
(In) setting
16.5
50
100
135
155
37.8
Trip indication
by earth fault
22
8.2
Trip indication
by earth fault
22
90
58
30
90
120
3P
4P
Terminal details
Connecting
Panel drilling
M4 or5
3P
60
82
M4 or5
4P
3P
4P
115
Dimensions
ELCB
EBN250c
EBS250c
EBH250c
(mm)
Insulation barrier
80
80
Insulation barrier
Fixing hole
Fixing hole
Trip indication
Trip indication
by earth fault
22
by earth fault
22
Residual current
Residual current
(In) setting
(In) setting
19.6
50
102
59.4
126
144
165
19.6
50
59.4
126
102
144
165
44.5
CL
14.5
14.5
44.5
105
70
105
2, 3P
4P
Terminal details
Connecting
Panel drilling
M4 or5
2, 3P
116
35
140
4P
2, 3P
4P
ELCB
EBN400c
EBS400c
EBH400c
EBL400c
(mm)
56.5
44
56.5
44
52.5
44
52.5
44
41.5
26.5
12
.5
44
52.5
25
16.5
23.9
41.4
48
48
57.9
46.9
215
150
225
Trip indication
by earth fault
257
16.5 23.9
41.4
48
48
57.9
46.9
215
150
225
257
Trip indication
by earth fault
Residual current
(In) setting
Residual current
(In) setting
51.1
140
184
3P
4P
Terminal details
Connecting
Panel drilling
M6 or6
142(3p)
187(4p)
142(3p)
187(4p)
3, 4P
3, 4P
M6 or6
Slot "A"
Slot "B"
Slot "C"
2, 3P
4P
2, 3, 4P
117
Dimensions
ELCB
EBN630c
EBS630c
EBL630c
EBN800c
EBS800c
EBL800c
(mm)
210
70
44
34.5
34.5
10
13.5
13.5
Earthleakage trip indicator
56
37
73.5
15
280
280
17
23.9
16.5
25
243
150
96
77.6
280
90.6
54.1
73.5
70
70
95
109
113
145
95
109
113
145
3P
Terminal details
Connecting
Panel drilling
Panel
cover A
Panel
cover B
Panel
cover C
3P
118
630AF : 7
800AF : 10
(Handle only)
(AUX. Cover)
ELCB
EBS1000b
EBS1200b
(mm)
Mounting hole
Mounting hole
Auxiliary handle
Reset
Auxiliary handle
Trip test button
Residual current
Reset
(In) setting
Trip test button
for earth fault
Residual current
(In) setting
Trip test button
for earth fault
3P
Panel drilling
60
3P
3P
119
Dimensions
C
L
C
L
MCCB
ABN100c
115
37
87
8.5
25
ABH125c
135
37
87
8.5
30
ABH250c
144
57.5
93.5
8.5
35
Round type
C
L
MCCB
120
ABN100c 50AF
115
42
92
M6
25
ABN100c 100AF
115
52
102
M8
25
ABH125c
135
52
102
M8
30
ABH250c
144
70
106
M8
35
Rotary handles
Direct mounting type (D-Handle, 30~250AF)
t1.2~3.2
t1.2~3.2
2-6
4-5
D
E
B
60
B
C
104
Type
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
Remarks
DH100
110.5
78
90
92
103.4
100AF
DH125
132
94
105
108
120
125AF
DH250
126
108
121
110
122
250AF
t1.2~3.2
t1.2~3.2
Panel
Panel
doordoor
105
52.552.5
105
52.552.5
105105
43 43
N-Handle
N-30c
N-40c
N-50c
Note
100AF
125AF
250AF
A (mm)
103
103
103
150
113
75
t1.2~3.2
51
121
Dimensions
Rotary handles
Extended mounting type (E-Handle) (30~250AF)
t1.2~3.2
~3.2
2-6
4-5
D
E
B
B
C
Type
A (mm)
B (mm)
C (mm)
Remarks
EH100
47
53
100AF
EH125
47
53
125AF
EH250
47
53
250AF
122
158.8
243
E-80U (800AF)
Technical Information
Standard accessories
The following accessories for mounting, connection and insulation are standard
items and are packed with Metasol series circuit breakers.
Item
100AF
125AF
250AF
400AF
800AF
3~50A
2P: 4EA (M514)
3P: 6EA (M514)
4P: 8EA (M514)
60~100A
2P: 4EA (M814)
3P: 6EA (M814)
4P: 8EA (M814)
Fixing
screw
Terminal
bolt
IB-23
IB-23
IB-13
IB-13
IB-23
IB-13
Insulation
barrier
2P: 1EA
3P: 2EA
4P: 3EA
2P: 1EA
3P: 2EA
4P: 3EA
2P: 1EA
3P: 2EA
4P: 3EA
2P: 1EA
3P: 2EA
4P: 3EA
2P: 1EA
3P: 2EA
4P: 3EA
N-30c
N-40c
N-50c
N-70
N-80
ABN 50c/60c/100c
ABS 125c
ABN 250c
ABN 400c
ABN 800c
ABS 30c/50c/60c
ABH 50c
ABS 250c
ABS 400c
ABS 800c
Applied MCCB
ABH 125c
ABH 250c
ABH 400c
ABL 800c
ABL 400c
EBN 50c/60c/100c
EBS 125c
EBN 250c
EBN 400c
EBN 800c
EBS 30c/50c/60c
EBH 50c
EBS 250c
EBS 400c
EBS 800c
Applied ELCB
EBH 125c
EBH 250c
EBH 400c
EBL 800c
EBL 400c
Fixing screw(short)
-
-
-
M616 M616
Fixing screw(long) M485
M485
M485 M6110
M6110
Handle type
DH/EH100
DH/EH125
DH/EH250
M470
M470
123
Technical Information
Connection
Tightening torque
(kgfcm)
Terminal
(mm)
MCCB
[3~50A]
8.2
7.5
7.5
18
18
8.2
24
24
24
18
M514
7
7
7.5
M514
8.2
7.5
7.5
7.5
8.28.2
8.2
18
18
7.5
24
24
M814
M814
10 10
16
16
7
9
9
9
9
9
9
24
24
8
8
M814
24
10
10
9
16
9
9
10
24
18
18
18
8
8
89
8
10
M820
M820
2121
28
M820
24
24
21
28
28
24
24
24
M820
28
18
8
8
9
18
18
18
18
18
9
9
18
18
9
9
10
10
10
25
25
25
10
10
109
10
25
9
25
25
25
10
10
10
25
25
9
25
9
25
10
10
24
24
18
9
9
9
9
9
9
24
21
21 21
21
21
250AF
M8 : 80 ~ 130
M820
28
28
28
24
M820
M820
M820
124
7 9
16
16
9
7
7
916
16
16
M814
18
28
9
9
11.5
7
7
16
11.5
5.5
11.5
11.59
7
9
9
16
16
16
11.
11
5.5
7
7
5.5
11.5
11.5
11.5
7 5.5
7
5.5
1010
24
24
24
18
M8 : 55 ~ 75
M814
M814
M814
M814
5.5
5.5
24
88
18
7
7
7
M814
7.5
M814
8 8
9
7
9
9
24
24
M814
8.2
24
24
24
18
M814
M814
24
125AF
18
5.5
5.5
5.5
11.5
7
11.5
7
11.5
[60~100A]
5.5
24
18
18
18
18
18
24
8.2
8.2
18
M814
M814
M814
7.5
18
24
24
[60~100A]
M514
8.2
18
18
18
5.5
5.5
5.5
100AF
7.57.5
7.5
18
[3~50A]
M8 : 55 ~ 75
M514
M514
7.5
8.2
18
18
18
M514
M514
M514
7.57.5
7.5
8.28.2
8.2
8.2
8.2
M5 : 23 ~ 28
Conductor
(mm)
25
10
Connection
Tightening torque
(kgfcm)
Terminal
(mm)
MCCB
Conductor
(mm)
37
M1030
.5
10
.5
10
29
29.5
13
29
400AF
37
29.5
30
M1030
12.5
12.5
M12 : 400~500
(Terminal, Busbar)
34.5
34.5
4
1
44
M1235
M1235
4
1
44
44
11
800AF
29
11
44
29
13
30
10.5
10.5
125
Technical Information
Safety clearance
When installing a circuit breaker, safety clearances must be kept between the breaker and panels, bars and
other protection devices installed nearby. These safety clearances are depend on the ultimate breaking capacity
and are defined by tests carried out in accordance with standard IEC 60947-2.
When a short circuit interruption occur, high temperatures pressures are present in and above the arc chambers
of the circuit-breaker. In order to allow the pressure to be distributed and to prevent fire and arcing or shortcircuit currents, safety clearances are required.
250V
ABN50c
40
25
ABN60c
40
25
ABN100c
50
30
ABS30c
30
25
ABS50c
40
30
ABS60c
40
30
ABS125c
50
40
ABH50c
50
40
ABH125c
100
80
ABN250c
100
80
ABS250c
100
80
ABH250c
100
80
ABN400c 100 80
ABS400c 100 80
400AF
ABH400c 100 80
ABL400c
ABN800c 100 80
100 80
126
ABL800c
100 80
250AF
460V
125AF
A(mm)
100AF
Description
Frame
size
50
30
ABS30c
30
25
ABS50c
40
30
ABS60c
40
30
ABS125c
50
40
ABH50c
50
40
ABH125c
100
80
ABN250c
100
80
ABS250c
100
80
ABH250c
100
80
ABL400c
ABN800c 100 80
C1
C1
C
C1
C1
ABS400c 100 80
400AF
ABH400c 100 80
ABN400c 100 80
100 80
ABL800c
100 80
Direct
connection
of cable
Connection
by using a
crimp-type
terminal lug
Connection
by using a
crimp-type
terminal lug to
the extended
terminal
127
ABN100c
25
C1
25
40
C1
40
ABN60c
ABN50c
C (mm)
C
C1
250AF
250V
C
C1
125AF
C1 (mm)
460V
C1
100AF
Description
Frame
size
Technical Information
Safety clearance
Insulated length of main terminal of circuit breaker
D1: Connection by solerless terminal with taping
D2: Connection by busbar with taping
D3: Connection by solderless terminal and using insulation barrier
D4: Connection by busbar and using insulation barrier
(mm)
(mm)
(mm)
(mm)
ABN60c
40
40
ABN100c
50
50
ABS30c
30
30
ABS50c
40
40
ABS60c
40
40
ABN400c
50
50
50
50
50
50
50
50
100 100
ABS400c
400AF
ABH400c
100
100
100
100
ABL400c
100
100
800AF ABS800c
150
150
150
150
ABL800c
D4
50
D3
50
50
D2
ABS250c
50
D1
ABH50c
ABH250c
128
D4
40
ABN250c
D3
40
ABH125c
250AF
D2
ABN50c
ABS125c
125AF
D1
100AF
Description
Frame
size
100AF
125AF
250AF
Description
E(mm)
460V
250V
ABN50c
25
15
ABN60c
25
15
ABN100c
25
15
ABS30c
20
15
ABS50c
25
15
ABS60c
25
15
ABS125c
25
15
ABH50c
25
15
ABH125c
50
20
ABN250c
50
15
ABS250c
50
15
ABH250c
50
15
ABN400c 80 40
ABS400c 80 40
400AF
ABH400c 80 40
ABL400c
ABN800c 80 40
80
40
800AF ABS800c 80 40
ABL800c
80
40
129
Technical Information
Safety clearance
Frame
size
100AF
125AF
250AF
Description
F(mm)
ABN50c
10
ABN60c
10
ABN100c
ABS30c
ABS50c
10
ABS60c
10
ABS125c
ABH50c
10
ABH125c
20
ABN250c
ABS250c
ABH250c
ABN400c 10
ABS400c 10
400AF
ABH400c
10
ABL400c
ABN800c 10
800AF ABS800c 10
130
10
ABL800c
10
100AF
125AF
250AF
Description
G(mm)
ABN50c
ABN60c
ABN100c
ABS30c
ABS50c
ABS60c
ABS125c
ABH50c
ABH125c
ABN250c
ABS250c
ABH250c
ABN400c 0
ABS400c
400AF
ABH400c
ABL400c
ABN800c 0
800AF ABS800c
ABL800c
0
0
131
Technical Information
CE conformity marking
The CE conformity marking shall indicate conformity to all the obligations imposed on the
manufacturer, as regards his products, by virtue of the European Community directives providing
for the affixing of the CE marking.
When the CE marking is affixed on a product, it represents a declaration of the manufacturer or of
his authorized representative that the product in question conforms to all the applicable provisions
including the conformity assessment procedures.
132
133
Technical Document
Ampere
Frame
current
30
50
60
100
125
current
10
20
30
40
45
50
55
10
10
10
10
10
10
10
ABS30c
15
15
15
15
15
15
14
13
20
20
20
20
20
20
19
19
18
30
30
30
30
30
30
29
28
27
40
40
40
40
40
40
39
38
36
50
50
50
50
50
49
47
45
60
60
60
60
60
58
56
55
15
50
60
75
100
125
ABN50c, ABS50c
ABN60c, ABS60c
ABN100c
ABH50c, ABS125c, ABH125c
150
175
250
200
225
ABN200c, ABS200c,
ABH250c
250
75
75
75
75
75
73
71
68
100
100
100
100
100
97
94
91
125
125
125
125
125
121
116
107
150
150
150
150
150
145
140
128
175
175
175
175
175
169
163
150
200
200
200
200
200
193
186
171
225
225
225
225
225
217
209
193
250
250
250
250
250
241
233
214
250 250 250 250 246 242 238
250 250
400
300
ABN400c, ABS400c
350
ABH400c, ABL400c
400
800
134
500 500 500 500 492 485 477
500 500
630
ABN800c, ABS800c
700
ABL800c
800
Ampere
Frame
10
20
30
40
45
50
55
15
15
15
15
15
15
15
15
20
20
20
20
20
19
19
18
30
30
30
30
30
30
29
28
27
40
40
40
40
40
40
39
38
36
50
50
50
50
50
49
47
45
60
60
60
60
60
58
56
55
15
30
50
60
100
125
20
50
60
75
100
125
EBS30c
EBN50c, EBS50c
EBN60c, EBS60c
EBN100c
EBH50c, EBS125c, EBH125c
150
175
250
current
200
225
EBN200c, EBS200c,
EBH250c
250
75
75
75
75
75
73
71
68
100
100
100
100
100
97
94
91
125
125
125
125
125
121
116
107
150
150
150
150
150
145
140
128
175
175
175
175
175
169
163
150
200
200
200
200
200
193
186
171
225
225
225
225
225
217
209
193
250
250
250
250
250
241
233
214
250 250 250 250 246 242 238
250 250
400
300
EBN400c, EBS400c
350
EBH400c, EBL400c
400
400 400 400 400 394 388 381
400
500
800
630
EBN800c, EBS800c
700 700 700 700 689 679 668
700 EBL800c 700
800
135
Technical Document
Impact of Altitude
If an MCCB is used in an elevated area higher than 2000m sea level, its operating performance is subject to
dramatic drop in atmospheric pressure and temperature. For example, the air pressure is reduced to 80% of
ordinary pressure at 2,200m and further 50% at 5,500m although the short-circuit performance is not affected. If
it is used in areas of high sea level, you can do correction based on the correction parameter table in high
altitude environment, as described below.
[Correction Parameter Table for Altitude]
136
Altitude
Voltage
Correction
Parameter
Current
Correction
Parameter
2,000m
1.00
1.00
3,000m
0.91
0.98
4,000m
0.82
0.96
5,000m
0.73
0.94
6,000m
0.65
0.92
Vibration
The magnitude of vibration is measured by double amplitude and frequency with the following equation with
accelerator.
g=0.002frequency(Hz)double amplitude (mm)
* g: multiple of gravitational acceleration (g=9.8m/sec2)
There are three types of vibration tests including resonance test, vibration endurance test, and malfunction test
as described below.
1) Resonant Test
Alter the frequency of sinusoidal wave within the range of 0~55Hz gradually with 0.5~1mm of double
amplitude applied to see if there is any occurrence of vibration on a specific part of MCCB.
2) Vibration Endurance Test
A sinusoidal wave with double amplitude of 0.5~1mm and frequency of 55Hz(resonant frequency obtained in
previous clause if there is a resonant point) is manually created to check the operational status.
3) Malfunction Test
Apply vibration for 10 minutes for each condition of altering double amplitude and frequency to check if there
is any malfunction in MCCB.
Impulse
The magnitude of impulse is denoted by the multiple of gravitational acceleration imposed on the equipment
and part. The test is conducted through a drop impulse test.
137
Technical Document
Mounting
Vertical mounting
Condition
Vibration,
Direction
of impulse
Left-right, Left-right,
Front-back Front-back
Top-down Top-down
Internal Impulse
Picture 1, 2, 3, 4
Picture
Picture
1 2
ON
ON
ON
Line Connection
Line Connection
Status of
MCCB
Test
Judgment
Result
Condition
must be normal
138
Picture 3
Picture34
Picture
Picture 2
ON
Picture 4
Cerfications
MCCB
ELCB
Approvals
Type
CE
Type
Approvals
Type
KEMA
Mark
and
name
KEMA
Type
Certificates
IEC
CE
Approvals
Type
KEMA
Mark
and
name
KEMA
Type
Certificates
IEC
KEMA
CE
KEMA
Europe
Netherlands
Korea
Europe
Netherlands
Korea
Europe
Netherlands
ABP104c
EBS33c
ABS33c
ABH102c
EBS34c
ABS34c
ABH103c
EBN52c
ABN52c
ABH104c
ABN53c
ABN202c
EBN53c
ABN54c
ABN203c
EBS53c
ABS52c
ABN204c
EBS54c
ABS53c
ABS202c
EBN63c
ABS54c
ABS203c
EBS63c
ABN62c
ABS204c
EBS64c
ABN63c
ABP202c
EBN102c
ABN64c
ABP203c
EBN103c
ABS62c
ABP204c
ABS63c
ABH202c
EBN104c
ABS64c
ABH203c
EBS33d
ABN102c
ABH204c
EBS34d
EBN52d
EBN53d
EBS53d
EBS54d
EBN63d
EBS63d
EBS64d
ABN402c
ABN403c
ABN404c
ABS33d
ABS402c
ABS34d
ABS403c
ABN52d
ABS404c
ABN53d
ABH402c
ABN54d
ABH403c
ABS52d
ABH404c
ABS53d
ABL402c
ABS54d
ABL403c
ABN62d
ABL404c
ABN63d
ABN602c
ABN64d
ABN603c
ABS62d
ABS63d
ABS64d
ABN102d
ABN103d
ABN104d
MCCB 400~800AF
ABS32d
ELCB 30~250AF
ABN104c
MCCB 30~250AF
Korea
ABS32c
ABN103c
MCCB 30~250AF
Certificates
IEC
EBN102d
EBN103d
EBN104d
EBP53c
EBP54c
EBH53c
ABN604c
EBH54c
ABS602c
ABS603c
EBS103c
ABS604c
EBS104c
ABL602c
EBP103c
EBP104c
ABL603c
ABP52c
ABL604c
EBH103c
ABP53c
ABN802c
EBH104c
ABP54c
ABN803c
EBN202c
ABH52c
ABN804c
EBN203c
ABH53c
ABS802c
ABH54c
ABS803c
EBS203c
ABS102c
ABS804c
EBS204c
ABS103c
ABL802c
EBP203c
ABS104c
ABL803c
EBP204c
ABP102c
ABL804c
EBH203c
ABP103c
EBH204c e
Note: (Completion)
139
LSMS
<Android>
<IOS>
This application is selection
guide of motor starter,
overload relays and MCCBs
For your safety, please read user's manual thoroughly before operating.
Contact the nearest authorized service facility for examination, repair, or adjustment.
Please contact qualified service technician when you need maintenance.
Do not disassemble or repair by yourself!
Safety Instructions
Any maintenance and inspection shall be performed by the personnel having expertise concerned.
HEAD OFFICE
LS-ro 127 (Hogye-dong) Dongan-gu, Anyang-si,
Gyeonggi-Do Korea
Tel. 82-2-2034-4902, 4684, 4429
Fax. 82-2-2034-4555
www.lsis.com
GLOBAL NETWORK
Overseas Subsidiaries
LSIS USA Inc. Chicago, America
LOB 19-205, JAFZA View Tower, Jebel Ali Free Zone, Dubai, United Arab Emirates
Tel: 971-4-886-5360
Fax: 971-4-886-5361
E-mail: hschoib@lsis.com
Tokyo Club Building 13F, 2-6, Kasumigaseki 3-chome, Chiyoda-ku, Tokyo, 100-0013
Tel: 81-3-6268-8241
Fax: 81-3-6268-8240
E-mail: jschuna@lsis.com
No. 15, Liaohexi 3-Road, Economic and Technical Development Zone, Dalian 116600, China
Tel: 86-411-8273-7777
Fax: 86-411-8730-7560
E-mail: tangyh@lsis.com
102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China
Tel: 86-510-8534-6666
Fax: 86-510-522-4078
E-mail: wangzy@lsis.com
E-mail: sjbaik@lsis.com
Overseas Branches
LSIS Co., Ltd, Indonesia
APL TOWER lantai 10 unit 3, Jl. Letjen S. Parman Kav. 28, 11470, Jakarta Barat, Indonesia
Tel: 62-21-2933-7614
Fax: 62-21-2933-7624
E-mail: dioh@lsis.com
2016. 07
Low voltage circuit breakers (E) 2009. 10/(18) 2016. 07 Printed in Korea STAFF