Você está na página 1de 3

MUHAMMAD JAHANGIR

Contact # 0334-3814620(0300-9675579)
House No A-2022 PH –II ,GULSHAION –E-
HADEED BIN QASIM KARACHI
E-mail: jahangirjam@yahoo.com

OBJECTIVE: SEEKING A CHALLENGING IN OPPORTUNITY IN PROGRESSIVE


ORGANIZATION IN THE HELD OF ELECTRICAL AND CONTROL.

EXPERIENCE: 05YEARS

Present job: As an Electrical technician in Fauji Fertilizer Bin Qasim Ltd Karachi
(15 Oct, 2008 to till date).
Apprenticeship
Training: I’ve got two year apprenticeship in the field of “Electrical technician”
from Fauji Fertilizer Bin Qasim Ltd Karachi.
(12-01-2007 to 12-10-2008).
People Steel Mills
Karachi.
Electrical Technician (Dec 2005 to Jan 2007)
JDW Sugar Mills Electrical Technician (Sep 2004 to Dec 2005)
R.Y. Khan
 Performed routine inspection, maintenance & protection testing
of LV, MV transformers rating upto 12 MVA hermetically
sealed, AEG, ABB, cutler hammer.(13.8KV/2.4KV,480V)
 Performed inspection, maintenance LV, MV circuit breakers,
AEG, ABB, Cutler hammer.(VCB 2.4KV, ACB 480V)

 Worked on Different Voltage Level i.e 2.4KV/60HZ,


480V/60HZ, 120V/60HZ, 208V/60HZ, 380V/50HZ ,
220V/50HZ,
 Performed routine checking, and maintenance of UPS (on-
Line ) rated up to 100 KVA
 Performed preventive maintenance jobs of motors on the basis
quarterly and yearly.
 Worked in the Erection of the Plant (JDW Plant).
 Did all the Powers and control Connections of the Plant
Machines.
 Overhauling of Motors.
 Trouble-shouting of all MCC (AEG, Siemens)
 Installed, Troubled-shouted and did connections of VFD
Danfoss VLT to 75 KW.
 Meggering, Earthing, and all checks with DVM and Clamp
Meter.
 Participated in Drawing of Control and Power Diagrams.
BMR(Balancing Modernization and Revamping) of DAP and Ammonia Plant.

I participated in the following activities:

 Installation, testing, commissioning, LV switch gears, LV motors


starters with AREVA teams and also involved in checking of its
control loop.

 Supervised of DESCON and AJC team for installation of PA system,


fire alarm, lighting system, grounding system, LV motors, Cable trays,
laying power control and grounding cables and termination. Also
supervised the casual labours during the TA of NH3 unit and DAP
plant.

 Coordinated with various departments when required for the


adjustment of electrical equipments such as Cable trays, Lights, PA
and Telephone system.

 Held responsibilities to arrange material for DAP and NH3 Revamp


such as Cable Trays, Cables (Control Power Ground) lamps industrial
power plug cable ties and gland.

 Involved in material inspection a handling for DAP revamp project.

 Studied drawing and materials concerning DAP Revamp these:


 Cable trays
 Cable laying
 Layout plan for lights, industrial power plugs,
grounding.
 Motors installation lay out plan
EDUCATION:
Diploma of Associate Engineer in “Electrical Technology” in 1st
Division. (S.P.I Sadiqabad in 2004)
Metric Science in 2nd Division from (Bahawal Pur Secondary Board of
Education)
SPECIAL IMPROVEMENT COURSES:

• Fire fighting training


• Permit to work system (PTW)
• Emergency Procedures
• PPE,s Training

PERSONAL INFORMATION:

Father’s Name : Jam Faiz Ahmed


Date of Birth : 19 March, 1985
Status : Married
Religion : Islam
Nationality : Pakistani
Domicile : Punjab (Rahim Yar Khan)
N.I.C : 31304-7959429-9

Você também pode gostar