Você está na página 1de 2

September

2016
Revision 1

Blades
B22 M3

Intel E5-2400
Up to 384GB RAM
2 - SFF HDD slots

B200 M4

Intel E5-2600 v3 or v4
Up to 1.5TB RAM
2 - SFF HDD slots

19" Rackmount
B420 M4

Intel E5-4600 v3 or v4
Up to 3TB RAM
4 - SFF HDD slots

C220 M4

Intel E5-2600 v3 or
v4
24 DDR4 RAM Slots
4-LFF or 8-SFF HDD
Slots
2 PCIe Slots

C240 M4

Intel E5-2600 v3 or v4
24 DDR4 DIMM Slots
24-SFF or 12-LFF HDD
Slots
Up to 6 PCIe Slots

The UCS Mini 5108 chassis can support up to 4 power supplies. They can be either AC or DC, but you must not mix the two
types in the same chassis. For DC power Cisco uses a 48VDC PSU, and for AC they support between 100-240v.
For 120 volt AC based chassis configs there are some restrictions on the number of supported blades. Below is a chart
that shows different PSU configurations and the number of blades supported in that configuration. Both DC and 200240v power supplies do not have these restrictions.

There is only one cooling fan option for the


UCS Mini, and each 5108 chassis will require
8 cooling fans each.
UCS Systems also require a large amount of
air to move through the chassis, Cisco
recommends leaving plenty of room in front
and behind the rack so that
proper ventilation is possible.
A fully loaded UCS Mini can create as much
as 13,000 BTU/hr if fully populated with
B200 blades.
The recommended operating temperature is
50-95 degrees Fahrenheit with no more then
90% humidity.