Warning

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

PCS0534

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local distributor.

AIR CONDITIONING SYSTEM


COOLING ONLY
HE AT PUMP

[ 60 Hz ]
[ 60 Hz ]

For high outdoor temperature use


Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an
outdoor unit with anti-corrosion treatment.

The air conditioners manufactured


by Daikin Industries have
received ISO 9001 certification for
quality assurance.
Certificate Number. JMI-0107
JQA-0495
JQA-1452

All Daikin Industries locations


and subsidiaries in Japan have
received environmental
management system standard
ISO 14001 certification.
Daikin Industries, Ltd.
Domestic Group
Certificate Number. EC99J2044

About ISO 14001


ISO 14001 is the standard defined by the
International Organization for Standardization (ISO)
relating to environmental management systems.
Our group has been acknowledged by an
internationally accredited compliance organisation
as having an appropriate programme of
environmental protection procedures and activities
to meet the requirements of ISO 14001.

Head Office:
Umeda Center Bldg., 4-12, Nakazaki-Nishi
2-chome, Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 18-1, Konan
2-chome, Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/

r e a t io n o f

c All rights reserved


Printed in Japan 02/05/003 SW HP SS

The specifications, designs, and information in this brochure are subject to change without notice.

o m fo r t

Cooling only
Capacity *1

HP

2.5

10

15

20

kW

5.6

6.8

8.1

11.4

14.3

15.8

24.0

29.2

47.9

58.4

Btu/h

19,100

23,200

27,800

38,900

48,800

53,900

81,800

99,600

163,500

199,400

kcal/h

4,820

5,850

7,000

9,800

12,300

13,500

20,600

25,100

41,200

50,200

FHC50KVE

FHC60KVE

FHC71KVE

FHC100KVE

FH(Y)C125KVE

FHYC140KVE

R50GVAL

R60GVAL

R71FUVAL

R100FUVAL

R125FUTAL(R125KUYALK)

R140KUTALK/YALK

Indoor unit

FH50BVE

FH60BVE

FH71BVE

FH100BVE

FH125BVE

Outdoor unit

R50GVAL

R60GVAL

R71FUVAL

R100FUVAL

R125FUTAL

FA71FVEK

FA100FVEK

R71FUVAL

R100FUVAL

Indoor unit

FV71LAVE

FV100LAVE

FV125LAVE

Outdoor unit

R71FUVAL

R100FUVAL

R125FUTAL

FDM03FAVAL

FDM04FAVAL

FDM05FAVAL

FDYM06FAVAL

R71FUVAL

R100FUVAL

R125FUTAL

R140KUTALK

FD03KVAL

FD04KVAL

FD05KTAL

FD06KTAL

FD08KTAL

FD10KTAL

FD15KTAL

FD20KTAL

R71FUVAL

R100FUVAL

R125FUTAL

RU06KTAL

RU08KUTAL
RU08KTAL

RU10KUTAL
RU10KTAL

RU08KUTAL 2
RU08KTAL 2

RU10KUTAL 2
RU10KTAL 2

R71FUVAL

R100FUVAL

RU08KUTAL
RU08KTAL

RU10KUTAL
RU10KTAL

RU08KUTAL 2
RU08KTAL 2

RU10KUTAL 2
RU10KTAL 2

CEILING MOUNTED
CASSETTE TYPE
Page 9 11

Specifications Page 22

Indoor unit
Outdoor unit

CEILING SUSPENDED TYPE


Page 12

Specifications Page 22

WALL MOUNTED TYPE


Page 14

Specifications Page 23

Indoor unit
Outdoor unit

FLOOR STANDING TYPE


Page 14

Specifications Page 23

PACKAGED AIR CONDITIONERS

LOW STATIC
PRESSURE TYPE

Specifications Page 24

Indoor unit
Outdoor unit

FDB50KVE

FDB60KVE

FDB71KVE

R50GVAL

R60GVAL

R71FUVAL

MIDDLE STATIC
PRESSURE TYPE
DUCT
CONNECTION

Page 15 16

Specifications Page 24

Indoor unit
Outdoor unit

HIGH STATIC
PRESSURE TYPE

Specifications Page 25 26

Indoor unit
Outdoor unit
Outdoor unit

(Type without factory charged refrigerant)

OUTDOOR UNIT
Page 17 18
R50GVAL

R60GVAL

R125KUYALK R125FUTAL

R140KUTALK
R140KUYALK

RU06KTAL

Notes)
*Capacities of FD series are gross capacities which do not include a deduction for evaporator fan motor heat.

*1. The values given on the right are for the FHYC type. Values for other types may differ slightly.
The values given for 8HP to 20HP are for the FD type.

Cooling only
Page 19 20

Simultaneous operation system TWIN MULTI OPERATION

Capacity *1

HP

Specifications
Page 27 29

10

15.8

22.2

26.6

Btu/h

53,900

75,800

90,800

kcal/h

13,500

19,100

22,900

FHYC71KVE 2
R140KUTALK

FHYC100KVE 2
R200KUTAL/YAL

FHYC125KVE 2
R250KUTAL/YAL

FHY71BVE 2
R140KUTALK

FHY100BVE 2
R200KUTAL/YAL

FHY125BVE 2
R250KUTAL/YAL

FDYM04FAVAL 2
R200KUTAL/YAL

FDYM05FAVAL 2
R250KUTAL/YAL

R200KUTAL
R200KUYAL

R250KUTAL
R250KUYAL

kW

CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit

Simultaneously running
2 to 4 units completely
distributes comfort across
wide spaces.

CEILING SUSPENDED
TYPE
Indoor unit
Outdoor unit

DUCT CONNECTION
MIDDLE STATIC PRESSURE
TYPE
Indoor unit
Outdoor unit

Simultaneous control with


2 units in spacious room

Simultaneous control with


3 units for irregularly shaped room

OUTDOOR UNIT
Page 17 18
R140KUTALK

Page 19 20

*1. The values given on the right are for the FHYC type.

Simultaneous operation system TRIPLE MULTI OPERATION

Capacity *1

Page 19 20

Specifications
Page 27 29

Specifications Page 27 28

Simultaneous operation system DOUBLE TWIN MULTI OPERATION

HP

10

kW

15.8

22.2

22.2

26.6

Btu/h

53,900

75,800

75,800

90,800

kcal/h

13,500

19,100

19,100

22,900

FHYC50KVE 3
R140KUTALK

FHYC71KVE 3
R200KUTAL/YAL

FHYC50KVE 4
R200KUTAL/YAL

FHYC60KVE 4
R250KUTAL/YAL

FHY50BVE 3
R140KUTALK

FHY71BVE 3
R200KUTAL/YAL

FHY50BVE 4
R200KUTAL/YAL

FHY60BVE 4
R250KUTAL/YAL

R200KUTAL
R200KUYAL

R250KUTAL
R250KUYAL

CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit

CEILING SUSPENDED
TYPE
Indoor unit
Outdoor unit

DUCT CONNECTION
MIDDLE STATIC PRESSURE
TYPE
FDYM03FAVAL 3
R200KUTAL/YAL

Indoor unit
Outdoor unit

OUTDOOR UNIT
Page 17 18
R140KUTALK
*1. The values given on the right are for the FHYC type.

R200KUTAL
R200KUYAL

Large room air conditioned by


simultaneous control of four
distributed units

Heat pump
Capacity *1

2
5.8

2.5
6.5

3
8.1

4
11.4

Btu/h

19,800

22,200

27,800

38,900

48,800

53,900

kcal/h

4,990

5,590

7,000

9,800

12,300

13,500

6.3

7.19

9.0

12.8

16.2

18.1

Btu/h

21,500

24,500

30,600

43,700

55,200

kcal/h

5,420

6,180

7,700

11,000

13,900

FHYC50KVE

FHYC60KVE

FHYC71KVE

FHYC100KVE

FHYC125KVE

FHYC140KVE

RY50GVAL

RY60GVAL

RY71FUVAL

RY100FUVAL

RY125FUTAL

RY140KUTALK/YALK

FHY50BVE

FHY60BVE

FHY71BVE

FHY100BVE

FHY125BVE

RY50GVAL

RY60GVAL

RY71FUVAL

RY100FUVAL

RY125FUTAL

FHYB71FVAL

FHYB100FVAL

FHYB125FVAL

RY71FUVAL

RY100FUVAL

RY125FUTAL

Indoor unit

FAY71FVE

FAY100FVE

Outdoor unit

RY71FUVAL

RY100FUVAL

FVY71LAVE

FVY100LAVE

FVY125LAVE

RY71FUVAL

RY100FUVAL

RY125FUTAL

FDYM03FAVAL

FDYM04FAVAL

FDYM05FAVAL

FDYM06FAVAL

RY71FUVAL

RY100FUVAL

RY125FUTAL

RY140KUTALK

HP
kW

Cooling

kW

Heating

5
14.3

6
15.8

8
22.2

10
27.1

15
43.5

20
53.0

75,700

92,500

148,000

181,000

19,100

23,300

37,400

45,600

23.2

29.5

44.8

56.8

61,900

79,200

100,700

153,000

194,000

15,600

20,000

25,400

38,500

48,800

FDY08KATAL/YAL

FDY10KATAL/YAL

FDY15KATAL/YAL

FDY20KATAL/YAL

RY200KUTAL/YAL

RY250KUTAL/YAL

RY200KUTAL
RY200KUYAL

RY250KUTAL
RY250KUYAL

CEILING MOUNTED CASSETTE TYPE

Page 9 11
Indoor unit
Specifications Page 30

Outdoor unit

CEILING SUSPENDED TYPE

Page 12
Indoor unit
Specifications Page 30

Outdoor unit

CEILING MOUNTED BUILT-IN TYPE

Page 13
Indoor unit
Specifications Page 31

Outdoor unit

WALL MOUNTED TYPE

Page 14
Specifications Page 31

FLOOR STANDING TYPE

Page 14
Indoor unit
Specifications Page 32

Outdoor unit

PACKAGED AIR CONDITIONERS

LOW STATIC PRESSURE


TYPE

Specifications
Page 33

DUCT
CONNECTION
Page 15 16

Indoor unit
Outdoor unit

FDYB50KAVE

FDYB60KAVE

FDYB71KAVE

RY50GVAL

RY60GVAL

RY71FUVAL

MIDDLE STATIC PRESSURE


TYPE

Specifications
Page 32

Indoor unit
Outdoor unit

HIGH STATIC PRESSURE


TYPE

Specifications
Page 34

Indoor unit
Outdoor unit

RY200KUTAL/YAL 2 RY250KUTAL/YAL 2

OUTDOOR UNIT
Page 17 18

RY50GVAL

RY60GVAL

RY71FUVAL

RY100FUVAL

RY125FUTAL

RY140KUTALK
RY140KUYALK

Notes)
*Cooling capacities of FDY series are gross capacities which do not include a deduction for evaporator fan motor heat.

*1. The values given on the right are for the FHYC type. Values for other types may differ slightly.
The values given for 8HP to 20HP are for the FDY type.

RY200KUTAL 2
RY200KUYAL 2

RY250KUTAL 2
RY250KUYAL 2

Heat pump
Page 19 20

Simultaneous operation system TWIN MULTI OPERATION


Capacity

*1

HP

10

15.8/18.1

22.2/22.7

26.6/28.4

Btu/h

53,900/61,900

75,800/77,500

90,800/97,000

kcal/h

13,500/15,600

19,100/19,500

22,900/24,400

FHYC71KVE 2
RY140KUTALK

FHYC100KVE 2
RY200KUTAL/YAL

FHYC125KVE 2
RY250KUTAL/YAL

FHY71BVE 2
RY140KUTALK

FHY100BVE 2
RY200KUTAL/YAL

FHY125BVE 2
RY250KUTAL/YAL

FDYM04FAVAL 2
RY200KUTAL/YAL

FDYM05FAVAL 2
RY250KUTAL/YAL

RY200KUTAL
RY200KUYAL

RY250KUTAL
RY250KUYAL

kW

Cooling / Heating

Specifications
Page 34 36

CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit

Simultaneously running
2 to 4 units completely
distributes comfort across
wide spaces.

CEILING SUSPENDED
TYPE
Indoor unit
Outdoor unit

DUCT CONNECTION
MIDDLE STATIC PRESSURE TYPE
Indoor unit
Outdoor unit

Simultaneous control with


2 units in spacious room

Simultaneous control with


3 units for irregularly shaped room

Large room air conditioned by


simultaneous control of four
distributed units

OUTDOOR UNIT
Page 17 18
RY140KUTALK

Simultaneous operation system TRIPLE MULTI OPERATION


Capacity

*1

Cooling / Heating

Page 19 20

Specifications
Page 34 36

Page 19 20

Specifications Page 34 36

Simultaneous operation system DOUBLE TWIN MULTI OPERATION

HP

10

kW

15.8/18.1

22.2/22.7

22.2/22.7

26.6/28.4

Btu/h

53,900/61,900

75,800/77,500

75,800/77,500

90,800/97,000

kcal/h

13,500/15,600

19,100/19,500

19,100/19,500

22,900/24,400

FHYC50KVE 3
RY140KUTALK

FHYC71KVE 3
RY200KUTAL/YAL

FHYC50KVE 4
RY200KUTAL/YAL

FHYC60KVE 4
RY250KUTAL/YAL

FHY50BVE 3
RY140KUTALK

FHY71BVE 3
RY200KUTAL/YAL

FHY50BVE X 4
RY200KUTAL/YAL

FHY60BVE 4
RY250KUTAL/YAL

FDYB71KAVE 3
RY200KUTAL/YAL

FDYB50KAVE 4
RY200KUTAL/YAL

FDYB60KAVE 4
RY250KUTAL/YAL

RY200KUTAL
RY200KUYAL

RY250KUTAL
RY250KUYAL

CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit

CEILING SUSPENDED
TYPE
Indoor unit
Outdoor unit

DUCT CONNECTION
LOW STATIC PRESSURE TYPE
Indoor unit
Outdoor unit

DUCT CONNECTION
MIDDLE STATIC PRESSURE TYPE
FDYM03FAVAL 3
RY200KUTAL/YAL

Indoor unit
Outdoor unit

OUTDOOR UNIT
Page 17 18
RY140KUTALK

RY200KUTAL
RY200KUYAL

*1. The values given on the right are for the FHYC type.

Super cassette type is more compact, lighter and


easier to install than the conventional types.
Maintainability also greatly improved.

CEILING
MOUNTED CASSETTE
CEILING-MOUNTED
CASSETTE TYPE
TYPE
F H (Y )C 5 0 1 4 0 K
Accessory required for indoor unit (option)
Sound level

3 5 /3 0
[High]

[Low]

Wired LCD remote controller

Wireless LCD remote controller


A signal rec eiver must be
added to the indoor unit.

dB

FHYC71K

Compact and aesthetic square panel type


Uniform panel size for all models.

BRC1C61

BRC7C613W
(for c ooling only type)

Note: R emote c ontroller c able not


inc luded. C ables must be
proc ured loc ally.

BRC7C612W
(for heat pump type)

The conventional 100 140models' rectangular panel types have all been
converted to the same compact square type as the 50 71models. This
permits smooth interior harmony of ceilings with the lighting fixtures.
Installation of multiple air conditioners of different capacities will also be
Signal receiver unit
(Installed type)

Quiet design

100~140
Wireles s remote c ontroller and s ignal
rec eiver unit are s old as a s et.

Uses the newly developed "Diffuser Turbo Fan" with application


of aircraft technology.

50~71

Quiet operation is realized by a unified structure of 3-dimensional


blades and air diffuser for arranging the flow of air in the air
conditioner.

Freedom of selection of installation location


(

Since a multi-flow system is used, 4-way, 3way or 2-way air flow can easily be
selected, permitting installation in
locations corresponding to interior

Diffuser

FHYC125F)

Can also be installed in high ceilings.

Two Select thermo-sensors


Max. 4.2 m(FHYC100K140K)

Note : For 3-way or 2-way air flow installation,


the sealing member (option) for air
discharge outlet must be used to
close off the unused outlet(s).

Thermo-sensors on both indoor unit and wired remote controller (option). Temperature detection can be set closer to
the living area to further improve comfort level.

3-Dimensional blade

* Indoor unit's thermo-sensor must be used when the air conditioner is controlled
from another room. (Wireless remote controller does not have a thermo-sensor.)

Standard
High ceiling

FH(Y)C50K71K
4-way
3-way
2-way
air flow
air flow
air flow

FH(Y)C100K140K
4-way
3-way
2-way
air flow
air flow
air flow

2.7 m
3.0 m
3.5 m

3.2 m
3.6 m
4.2 m

3.0 m
3.3 m
3.5 m

3.5 m
3.8 m

3.6 m
4.0 m
4.2 m

4.2 m
4.2 m

Standard setting

Pattern

Swings within the range of 10 to 65.

Adjustment pockets in the four corners of


the panel make height adjustment of the
main unit much easier.

Draft prevention setting

Pattern

Swing angle is set from 10 to 40 so


people are not subjected to strong winds
(Recommended where there are seats near
the air conditioner).

Setting to prevent soiling of ceiling

Swing angle is within a range of 30 to 65


to prevent blowing against the ceiling. (This
recommended for those who are particular
about cleanliness of the ceiling).

The FH(Y)C50K 71K are thin


models (230 mm) which can
be installed in narrow false
ceiling space.

10

10

65

50

10
30

65

Provided with high lift drain


water lift-up mechanism
(Increased lift of drain pipe up
to 750 mm from the ceiling).

Min. 245 mm

( )

10

40

40

Has been set to standard setting at time of shipment. This can be changed using the remote control.
9

Top class of the industry

Simplifies height adjustment of the main


unit.

There are 3 patterns in auto swing operation

30 dB
36 dB

Main unit is lighter and more compact to


further simplify installation
FH(Y)C100K 140K

Note: Set to standard 4-way air flow when shipped.


High ceiling types
and
will be set for
remote control operation.

Pattern

Low

35 dB
42 dB

Note: Operating sound may increase more than that when used with 3-way air flow
or 2-way air flow, or when used together with a optional kit.

Number of air flow outlets used

High ceiling

High

FH(Y)C71K
FH(Y)C125K

Criteria for ceiling height and number of air flow outlets

Ceiling
height

Indoor unit

30
65

65

Because of the light weight, suspension is possible without an


upper lift.

10

750 mm

CEILING SUSPENDED TYPE

Accessory required for indoor unit (option)

F H ( Y ) 5 0 1 2 5 B

Wired LCD remote controller

Wireless LCD remote controller

Maintenance is simple

A signal rec eiver must be


added to the indoor unit.

Soiling of ceiling reduced 3040% (compared to conventional models).


Conventional system

Cleaning is simple because of the "Non-dew Flap" with no flocking.


Although flocking is presently used on flaps to prevent dewing, the
new flaps are "Non-dew Flaps" that do not soil easily and are easy to

New system

BRC1C61
Sound level

Horizontal
discharge

Newly set angle

3 9 /3 5

Non-dew flap

Stepping motor

[High]

Presently set angle

dB

Signal receiver unit


BRC7E66
(Installed type)
(for c ooling only type)
BRC7E63W
(for heat pump type)

Wireles s remote c ontroller and s ignal


rec eiver unit are s old as a s et.

FHY71B

Newly set angle

Upgrade to an even more quiet and


compact system.

Presently set angle

The ceiling tends to become soiled by


dust in the air temporarily blowing out
horizontally when resetting the flap angle.

[Low]

Note: R emote c ontroller c able not


inc luded. C ables must be
proc ured loc ally.

Thanks to the stepping motor,the flap can


be set to the new setting directly
preventing soiling due to the air flow not
hitting the ceiling.

A high efficiency mildew-proof long-life filter is provided as


standard parts. Maintenance not required for about one year
(2, 500 hrs).

Distributes comforting air flow throughout the room


Auto-swing for comfort in all directions.

Maintenance cost reduced since cleaning of the heat exchanger


is only necessary once every 3 years.
Maintenance cost is reduced by using a high-efficiency long-life filter
since maintenance is required only once every 3 years as compared
to once every 2 years as was previously the case.

Once

Wide air discharge openings produce a spreading 100 air flow.

Once
2years

3years

(Conventional model)

(New model)
New model
100

Maintenance is simple
Installable on ceilings
3. 5 m high.

Long-life filter lasts about 1 year *


Maintenance not required.
* For dust concentration of 0.15 mg/m3

Usingthe optional accessories produces anevenhigher level of comfort


Fresh air intake kit (Option)
Allows intake of fresh air from the outdoors. When neither heating
nor cooling is required, fresh air can be circulated by only using the
fan. This is especially useful in buildings in which ventilation fans

Fresh air intake kit

Intake duct

Two time settings (2500 hrs and 1250 hrs) are available to match the installation
environment. Maintenance time warning is displayed on the remote controller
(filter sign).

Branch duct chamber (Option)

Air filter

In addition to discharging air from the outlet on the decoration panel,


a duct can be connected to the air conditioner itself for an additional
discharge outlet. The additional discharge outlet is useful for areas
which tend to be crowded or near doors or windows where the
temperature is affected by the outside temperature.

(Outdoor)

Two Select thermo-sensors


Thermo-sensors on both indoor unit and wired remote controller (option). Temperature detection can be set closer to
the living area to further improve comfort level.
* Indoor unit's thermo-sensor must be used when the air conditioner is controlled
from another room. (Wireless remote controller does not have a thermo-sensor.)

Hood

Branch duct chamber


Discharge duct

Note : Intake duct, hood, air filter, insect screen, fireproof damper, etc. must be procured at a local outlet if needed.

Note :
Discharge duct, discharge panel, etc.
must be procured at a local outlet if
needed.

Drain-up kit (option) can be


easily incorporated.

Discharge panel

Three types of kits are available for


specific installation conditions.
For the details, see page.37.

Notes : Use only one branch duct chamber per air conditioner.
Close the decoration panel's outlet on the chamber installation side with the sealer
for the air discharge outlet.

Heat pump only

Drain-up kit (built inside main unit)

Heat pump only


(Option)

11

600 mm

12

CEILING MOUNTED BUILT-IN TYPE

WALL MOUNTED TYPE


Accessory required for indoor unit (option)

F A ( Y ) 7 1 /1 0 0 F

F H Y B 7 1 1 2 5 F

Wired LCD remote controller

A signal rec eiver must be


added to the indoor unit.

Sound level

Sound level

Accessory required for indoor unit (option)

4 1 /3 5
[High]

Wireless LCD remote controller

[Low]

dB

4 1 /3 7

Wired LCD remote controller

[High]

[Low]

dB

FAY71F(Cooling)
FHYB71F

BRC1C61

Note: R emote c ontroller c able not


inc luded. C ables must be
proc ured loc ally.

Wall mounted type units feature the lowest sound


levels in the industry and greatly upgraded comfort,
thanks to the high fan speed mode.

With the use of simple ducts, discharge outlets can be


located in a multitude of ways. Top priority given to interior
decor, built-in type units realize ideal air current distribution.

Signal receiver unit

BRC1C61
Note: R emote c ontroller c able not
inc luded. C ables must be
proc ured loc ally.

BRC7C69W
(Installed type)
(for c ooling only type)
BRC7C64W
(for heat pump type)

Wireles s remote c ontroller and s ignal


rec eiver unit are s old as a s et.

"High fan speed mode" for further comfort.


If an indoor "High fan speed mode" type unit is
installed in a long, narrow store or in the corner
of a room,there is approximately a 10% increase
in air volume. A comfortable air stream will reach
distant areas.

By separating the air outlet from the main unit and blowing air, various
conditions will be cleared such as in modified stores, state of sunshine
and gathering of people to realize comfortable air conditioning.
Heat pump only

FLOOR STANDING TYPE


F V ( Y ) 7 1 1 2 5 L A

Highly Flexible for Various Application


Highly flexible installation is possible with a complete lineup of optional kits to satisfy the various needs, such as
the design concept, interior decoration and so on.

Sound level

Floor standing type units are easy to install


and maintain; their slimness is suitable for
installation in high-ceiling stores and offices.

Installation examples
(*Optional parts)

4 1 /3 5 dB
[High]

[Low]

FVY71LA

Cassette style (standard filter)

Standard

Long-life filter
Liquid crystal control panel
(Standard equipment)

Long-life filter

The unit can be installed, if there is a space of 350 mm


above ceiling. (when suction panel is used.)

Air suction panel*

With duct (case 1)

Air suction
canvas bellows*

Cassette style (high efficiency filter)

Min.
350 mm

High-efficiency
filter*
Screening
door*

Access panel*
Air suction
canvas bellows*

Air suction panel*

Long-life Filter is provided as a standard accessory.

Drain-up pump is equipped as Standard accessory with


250 mm lift.

The panel can also be removed and used for remote


control such as controlling air conditioning from a
different room or from near the cashier.

Ceiling return

With duct (case 2)

Long-life filter

Long-life filter

250 mm

Access panel*

Screening
door*

These units are number one in the world in quietness and lightness.
The use of a high-efficiency, long-life filter reduces maintenance time and cost.

Maintenance cycle
Parts

Previous model

Filter

Once

Heat exchanger

Once

2 weeks

New model
Once

1 year

Access panel*

2 year

Once

3 year

The heat exchanger has been subjected to antibacterial treatment and mildew proofing.

Heat pump only

(Option)

13

14

DUCT CONNECTION LOW STATIC


PRESSURE TYPE F D ( Y ) B 5 0 7 1 K ( A )

DUCT CONNECTION MIDDLE STATIC


F D ( Y ) M 0 3 0 6 F A
PRESSURE TYPE
Accessory required for indoor unit (option)
Wired LCD remote controller

Sound level

Wireless LCD remote controller

Accessory required for indoor unit (option)

4 1 /3 8

A signal rec eiver must be


added to the indoor unit.

[High]

[Low]

dB

For heat pump type

FDB50K

Wired LCD remote controller

Wireless LCD remote controller


A signal rec eiver must be
added to the indoor unit.

Note: The unit shown in the photo is a dedicated cooling type.


Switch box dimensions differ for combination cooling/heating type.

Sound level

4 2 dB
[Low]

BRC1C61

BRC4C64 (for c ooling only type) Signal receiver unit

(Separate type)

Note: R emote c ontroller c able not


inc luded. C ables must be
proc ured loc ally.

BRC4C62 (for heat pump type)

Wireles s remote c ontroller and s ignal


rec eiver unit are s old as a s et.

FDM03FA

By placing the main unit into the false ceiling, the room's
design and finish remain beautiful and undisturbed. Together
with minimal operating sound,the units are perfect for rooms
where atmosphere is important.

These duct type air conditioners can be installed in the ceiling space
for an attractive interior finish. Daikin's middle static pressure duct type
air conditioners are compact and quiet, well-suited for use in a wide
variety of duct type air conditioning systems for homes, stores, and
offices.

BRC1C61
Note: R emote c ontroller c able not
inc luded. C ables must be
proc ured loc ally.

Signal receiver unit


(Separate type)

BRC4C62
Wireles s remote c ontroller and s ignal
rec eiver unit are s old as a s et.

For cooling only type


Digital remote controller

Remote controller

KRC47-2 / KRC47-4

KRC47-1

Suction Chamber
(standard equipment)
Air Filter (Field supply)
fig.1.0.

Heat pump only

Superior freedom of layout

The duct system allows the most efficient location of discharge outlets in
accordance with the room layout.

DUCT CONNECTION HIGH STATIC


PRESSURE TYPE F D ( Y ) 0 3 2 0 K ( A )

The standard-equipment rear intake chamber simplifies the duct


connecting work.

Compact, 295 mm height design makes installation possible where the


ceiling space is limited.

Accessory required for indoor unit (option)


Sound level

Ordinary duct
(procured locally)

Air conditioner
295 mm

For heat pump type

Ordinary duct
(procured locally)

46
[Low]

305 mm or more
Air intake

Air blow

dB

Wired LCD remote controller

Wireless LCD remote controller


A signal rec eiver must be
added to the indoor unit.

FD03K

FD05K
Heat pump only

FDY15KA

High static pressure that allows long duct and long


refrigerant piping enables flexible installation.
Recommended for spacious and large-volume areas like
large stores or factories.

BRC1C61
Note: R emote c ontroller c able not
inc luded. C ables must be
proc ured loc ally.

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)

Signal receiver unit


(Separate type)

BRC4C62
Wireles s remote c ontroller and s ignal
rec eiver unit are s old as a s et.

For cooling only type

When air conditioning two rooms simultaneously, the air


discharged into each room must be circulated back to the air
conditioner. To ensure this, a ventilation duct should be
installed for each room or one of the indicated ventilation
grilles should be installed on the partitioning wall or under the
door between the rooms.

Digital remote controller

Door-installed
ventilation grille

Wall-installed
ventilation grille Under-door cutout

KRC47-5

Remote controller

KRC47-3

Cooling only
Heat pump only

Partitioning wall

Ventilates air through the


partitioning wall. (see right)

Ventilation grille

Ventilation grille

Under-door cutout

FDY08-10KA only

Note : The under-door cutout method should be used only


when there is a small volume of air flow.

15

16

Outdoor Unit
Flexible design
for large room or
multi-use
R50G

R60G
RY50G

R(Y)71FU

RY60G

R125KU
RU06K
R(Y)140KU

R(Y)100/125FU

RU08K(U)
R(Y)200KU

Piping can be drawn out from three directions - front, left side, or below.

Reduces installation space.


( Applies to R71125FU and 140KU )

Equipped with "high static pressure" fan.

Also adapts to year-round cooling

Common width and depth make series installation easy.

RY200KU and RY250KU can adapt up to 0C.

RU08/10K models are available


in two types depending on
installation conditions

50

R(Y)200KU R(Y)200KU R(Y)250KU

"Air Flow Adjustment Guide" (standard equipment).


( Applies to R71125FU and 140KU )

RU08/10KU models are factory shipped with


refrigerant charged for 5 meters of piping.
RU08/10K models are factory shipped with no
refrigerant charged.

690 mm

Outdoor units include as standard equipment the "Air Flow Adjustment


Guide" which lets you set as desired the air flow in any one of four
directions in accordance with your layout. Cushions effect of air flow
striking against obstructions in front of the unit (walls,etc.) and prevents
"short circuits" from being formed.

(Heat pump only)

50

Long hypotenuse blades


(Optimal camber)

200 and 250 models can be combined for


centralized, horizontal-series installation

Long hypotenuse blades with a gentle camber make the pressure rise on the
surface of the blades smooth and uniform, while suppressing break away of
the flow. As a result, it prevents rise in draft resistance produced due to lack of
open space behind the unit, and prevents air power from dropping.

RU10K(U)
R(Y)250KU

Cross-section of "Air Flow Adjustment Guide".


1280 mm

1280 mm

1280 mm

Allowable refrigerant pipe length and height difference

30

R(Y)200KU

As show in the diagram, the air flow adjustment guide is factory set
so that exhaust air flow is inclined 30 degrees. The guide can be set
to direct the air flow to the left, right or down as well as upward, so
you can adjust the direction according to the place of installation.

R(Y)250KU

Pre-charged
*1

Max. length

5m

(Equivalent length 70 m)

5m

50 m

50 m

(Equivalent length 70 m)

Max. height
difference

30 m
30 m

Note: Additional refrigerant charging is required if the refrigerant pipe is


longer than the indicated length.

Anti-Corrosion treatment of heat exchange fins.

Main functions for extra comfort.

( Applies to all outdoor units )

The special acrylic precoated fin (PE fin) for anti-corrosion treatment
on the outdoor unit heat exchanger ensures greater resistance against
salt damage and atmospheric pollution than ever.

Greater of corrosion resistance


Against salt corrosion

Corrosion
resistance grade

Against acid corrosion

Non-treated fin

PE fin

Non-treated fin

PE fin

5 6

5 6

*Please look for available functions for the model you select.

Auto-swing

Program "Dry"

Construction.
Aluminium

R125KUYALK has been added to the list of


models capable of operating with outdoor air
temperatures of up to 54C.

Fan operation
mode

Self diagnosis
function

Auto-restart

OPTIONAL
FUNCTIONS

Timer selector

Automatic Cool/Heat
Change-over

Hot start

Fresh air intake

Draft preventive
function

Long life filter

Mold resistant
treatment for filter

Filter sign

Ceiling soiling
prevention

High ceiling
application

High fan
speed mode

Twin / triple /
double twin multi
application
(See page 1920)

(Refer to the Specifications for details on other model)

17

Two select
thermo-sensors

Hydrophilic film
Aluminium
C orrosion resistanc e ac rylic resin

18

Anti-corrosion
treatment of
outdoor heat
exchanger fins