PREMIUM B-Series Right angle gear drives in single/double reduction are intended to satisfy
characteristic requirements and conditions encountered in cooling tower applications. This series
covering models B-114 to B-145 (having ratio range of 1.22/1 to 4.57/1) in single stage and B-214 to B245 (having ratio range of 5.06/1 to 15.4/1) in double stage are exclusively meant for Cooling Tower
installations with features like uni-cast case, 3-point foundation, pump-less lubrication and combination
of labyrinth double oil seal arrangement towards fan end.
PREMIUM ABM-Series are designed to ensure that critical dimensions correspond to that of
Equivalent models.
This catalogue contains specifications, dimensions and ratings for selection of standard gear drives
against usual applications. Our engineers will be pleased to assist in case of unusual conditions
attracting special requirements.
Salient Features
Spiral Bevel Gears: These are manufactured from high quality case-hardening alloy steel, generated in
Klingelnberg cyclo-palloid system and lap finished in matching sets.
Helical Gears: These gears are machined from high quality alloy case-hardening steel, which are individually
flank ground to precision grade accuracy. Case hardened surface with softer core provides improved wear
resistance and fatigue strength.
Housing: Single piece grey cast iron casing is of rigid construction with necessary reinforcements. Provided with
easily accessible service ports they are suitably designed on CAD work stations to absorb fan loads and to dampen
noise and vibration. The three point foundation facilitates in achieving alignment.
For ABM Series: The gearbox housing are designed to ensure that critical dimensions correspond to those of
equivalent models.
Bearings: Taper Roller / Cylindrical Roller bearings from major manufacturers are used throughout. These
bearings are of ample capacity to support combined thrust and radial loads and are sized to meet or exceed the
minimum life requirement of AGMA / CTI.
Shafting: Input shaft integral with bevel pinion is machined from case-hardening alloy steel. Direct hardening steel
is used in case of output shaft. The cylindrical seats for bearings, wheel, seal, coupling, fan are finished by
precision grinding. These are also designed to accommodate external overhung loads and fan stresses, as
appropriate. Specific requirement towards fan fitment dimensions and input drive system must be addressed
during placement of order.
For ABM Series: The shaft extensions and positions are inline with the dimensional configuration of equivalent
drives.
Shaft Seals: The shaft extensions are fitted with spring-loaded rubber seals to prevent outflow of oil. The ingress of
external contaminants is particularly arrested on fan end by employing double-seals with a grease accumulation
between them. In addition, metallic labyrinth seal on output extension takes care of the moist atmosphere
containing micro bubbles of water particles.
Lubrication: Lubrication of gears and bearings is entirely self-contained by splash. Oil slinger on the input shaft
produces positive splash which, in turn, ensures continuous circulation of oil to top bearing through cast channels
and baffles. Recommended Lubricants are shown on the next page based on Ambient temperature.
Rotation: High Speed Shaft rotation speed : 1500 ~ 1750 r/min
Reduction Ratio: The Actual ratio may vary from the Nominal ratio by approx. 3%
Cooling: Standard gear units are cooled by normal heat dissipation through convection/radiation from externally
exposed surface. Thermal ratings are overriding when the discharge air temperature is 50C or less. Contact
Premium Transmission Ltd. (PREMIUM) when the discharge temperature exceeds 50C.
Direction of Rotation: As per standard practice of cooling tower gearboxes both input and output shaft rotate
CLOCKWISE when viewed on to respective shaft end. For any other requirement of shaft rotations, the gear
drives should be ordered accordingly. Backstop devices can be supplied upon request. Contact PREMIUM for
additional information / dimensional drawings.
Environment: These gearboxes are not designed for Corrosive or Explosive gas environments.
Altitude: Designed for Altitudes for 1000 m or less.
Selection Procedure
1.0
Gearbox ratio = Input speed / Output speed = Motor speed / Fan speed
1.1
Motor ratings as listed in rating charts correspond to input rpm at 1750 and 1500 rpm against standard
nominal reduction ratios.
1.2
A suitable model can therefore be selected from the table which represents a ratio closest to the desired
one and motor power at desired input speed.
2.0
Check for Output bearing L10 life (>100000 operating hours) in consideration with external loads
generated by the fan.
Design inputs required: Fan Static Weight, Aerodynamic thrust load
3.0
Check for Input bearing L10 life (>50000 operating hours) Design input required: Floating Shaft Length,
Floating Shaft weight, Floating Shaft arrangement (With / Without intermediate Support)
Unit
Ambient Temp 0C
-7 to +5
1500-750
VG 100
VG 150
VG 220
750-450
VG 150
VG 220
VG 320
450-250
VG 220
VG 320
VG 320
250-95
VG 320
VG 460
VG 460
Size
B-114
B-116
B-118
B-120
B-122
B-125
B-128
B-132
B-135
B-140
B-145
Net.
Weight
(kg)
90
130
152
182
236
258
310
520
670
880
990
Gross
*Oil
Weight Quantity
(kg)
(Liter)
98
5
143
7
167
10
199
14
259
20
282
25
340
35
570
52
730
65
950
78
1060
96
Unit
Size
B-214
B-216
B-218
B-220
B-222
B-225
B-228
B-232
B-235
B-240
B-245
Net.
Weight
(kg)
285
300
320
360
480
588
788
1050
1596
2130
2780
Gross
*Oil
Weight Quantity
(kg)
(Liter)
310
7
328
10
351
15
391
20
524
25
644
35
863
50
1150
85
1748
90
2340
130
3060
180
TRIBOL
TRAXOL
Viscosity
mm/s (cSt)
at 400C PREMIUM Bharat
Traxol Petroleum
G-32
Indian
Oil
Hindustan
Petroleum
BP
Energol
Castrol
SPARAN
Mobilgear
Shell
Cepsa
Kluberoil
Omala Oil Engranges GEM 1
Aral
Chevron
Gear
Compound
Tribol
VG 460
Amocam
Oil 460
Servomesh
SP 460
Parthan
EH - 460
GR-XP
460
Alpha
MW 460
Spartan EP Mobilgear
460
634
Omala
460
HP 460
460
Degol
BG 460
EP 460
Trebol
1100/460
VG 320
G-32
Amocam
Oil 320
Servomesh
SP 320
Parthan
EH - 320
GR-XP
320
Alpha
MW 320
Spartan EP Mobilgear
320
632
Omala
320
HP 320
320
Degol
BG 320
EP 320
Trebol
1100/320
VG 220
Amocam
Oil 220
Servomesh
SP 220
Parthan
EH - 460
GR-XP
220
Alpha
MW 220
Spartan EP Mobilgear
220
930
Omala
220
HP 220
220
Degol
BG 220
EP 220
Trebol
1100/220
VG 150
Amocam
Oil 150
Servomesh
SP 150
Parthan
EH - 460
GR-XP
150
Alpha
MW 150
Spartan EP Mobilgear
150
629
Omala
150
HP 150
150
Degol
BG 150
EP 150
Trebol
1100/150
VG 100
Amocam
Oil 100
Servomesh
SP 100
Parthan
EH - 460
GR-XP
100
Alpha
MW 100
Spartan EP Mobilgear
100
627
Omala
100
HP 100
100
Degol
BG 100
EP 100
Trebol
1100/100
Unit
Input
Rpm
1.22
1.35
1.5
1.66
1.84
2.03
2.25
2.49
1.517 1.679
1.846
2.038
2.250
2.478
2.76
3.05
3.38
3.73
4.13
4.57
2.762 3.053
3.389
3.722
4.125
4.563
Actual Ratio
1.219 1.345
1750
38
32
26
22
19
17
14
13
11
10
1500
33
28
23
20
17
15
13
11
10
1750
63
53
43
37
32
28
24
22
19
17
15
13
12
10
1500
56
47
38
33
28
25
22
19
17
15
13
12
10
1750
90
76
62
53
46
40
35
31
27
24
21
19
17
15
1500
80
68
55
47
41
36
31
28
24
21
19
17
15
14
1750
103
87
71
61
53
46
40
35
31
27
24
22
19
17
1500
91
77
63
54
47
40
36
31
27
24
21
19
17
15
1750
154
130
106
90
79
68
60
53
46
41
36
33
29
26
1500
136
115
94
80
70
60
53
47
41
36
32
29
26
23
1750
209
176
144
123
107
93
81
71
62
55
49
44
39
35
1500
185
156
127
109
94
82
72
63
55
49
43
39
34
31
1750
287
241
198
169
147
127
111
98
86
76
67
60
54
48
1500
254
213
175
149
130
112
98
87
76
67
59
53
48
42
1750
401
337
276
236
205
178
155
137
119
106
94
84
75
67
1500
354
298
244
208
181
157
137
121
106
94
83
74
66
59
1750
547
460
377
322
279
243
212
187
163
145
128
115
102
91
1500
484
407
333
284
247
214
188
165
144
128
113
102
90
81
1750
766
666
557
476
413
363
317
280
252
218
193
174
156
140
1500
677
589
493
421
365
321
280
247
222
193
171
154
138
124
1750
1037
886
740
644
576
503
440
390
340
303
267
240
214
191
1500
917
783
654
570
509
444
389
344
300
268
236
212
189
169
114
116
118
120
122
125
128
132
135
140
145
AGMA and CTI recommend a minimum Service factor of 2.0 for gear drives in cooling tower fan service when drive by electric
motor or steam turbine.
*When gear drives are to be selected using a service factor other than 2.0, multiply the 'Service Rating' from the table by
2.0 to get the 'Mechanical Rating'. The 'Mechanical Rating is then divided by the appropriate service factor to obtain the new
'Service Rating' at the required 'Service factor".
Forced lubrication is required for sizes marked Red Italics. Contact PREMIUM for additional information.
SIZE
B-114
350
370
240
B-116
380
430
260
B-118
415
460
275
B-120
450
490
300
B-122
485
530
325
B-125
505
550
350
B-128
610
630
375
B-132
690
690
410
B-135
830
760
430
B-140
925
840
485
B-145
985
940
530
38.018
38.002
45.018
45.002
48.018
48.002
55.030
55.011
58.030
58.011
65.030
65.011
75.030
75.011
85.035
85.013
95.035
95.013
110.035
110.013
125.040
125.015
32.018
32.002
38.018
38.002
45.018
45.002
50.018
50.002
55.030
55.011
60.030
60.011
70.030
70.011
80.030
80.011
90.035
90.013
95.035
95.013
110.035
110.015
E1
F1
L1
L2
75
68
80
73
390
120
180
300
100
28
28
M12
90
83
100
93
400
140
185
330
110
28
32
M16
105
95
110
100
450
155
205
355
110
32
32
M16
110
100
120
110
505
165
235
390
120
32
40
M20
120
110
125
115
545
180
255
440
120
40
40
M20
125
115
140
130
580
185
265
480
130
40
40
M24
145
135
150
140
640
230
300
580
160
40
40
M24
175
165
180
170
700
235
320
600
180
40
40
M30
195
185
200
190
800
260
370
640
180
50
50
M30
210
200
210
200
920
305
420
790
220
50
60
M36
210
200
220
210
1020
350
470
900
240
50
60
M36
SIZE
M1
M2
N1
N2
N3
Y1
B-114
M12
M12
30
14
200
60
13.0
14
B-116
M12
M16
35
18
225
70
15.0
18
B-118
M16
M16
35
18
253
70
15.0
18
B-120
M16
M20
45
22
270
90
17.0
22
B-122
M20
M20
45
22
300
90
17.0
22
B-125
M20
M20
50
26
320
100
17.0
26
B-128
M20
M20
50
26
330
100
17.0
26
B-132
M20
M20
65
33
430
130
25.0
32
B-135
M24
M24
65
33
550
130
25.0
32
B-140
M24
M30
77
39
580
155
50.0
40
B-145
M24
M30
77
39
620
155
50.0
40
10.000
9.964
14.000
13.957
14.000
13.957
16.000
15.957
16.000
15.957
18.000
17.957
20.000
19.948
22.000
21.948
25.000
24.948
28.000
27.948
32.000
31.969
10.000
9.964
10.000
9.964
14.000
13.957
14.000
13.957
16.000
15.957
18.000
17.957
20.000
19.948
22.000
21.948
25.000
24.948
25.000
24.948
28.000
27.948
Z1
41.000
35.000
40.800
34.800
48.500
41.000
48.300
40.800
51.500
48.500
51.300
48.300
59.000
53.500
58.800
53.300
62.000
59.000
61.800
58.800
69.000
64.000
68.800
63.800
79.500
74.500
79.300
74.300
90.000
85.000
89.800
84.800
100.000 95.000
99.800
94.800
116.000 100.000
115.800 99.800
132.000 116.000
131.800 115.800
Z2
3.0
2.8
3.5
3.2
3.5
3.2
4.0
3.8
4.0
3.8
4.0
3.8
4.5
4.3
5.0
4.8
5.0
4.8
6.0
5.8
7.0
6.8
Input
Rpm
5.06
5.6
6.2
6.86
7.59
8.4
9.3
10.3
11.4
12.6
14
15.4
214
1750
35
34
33
31
29
26
24
22
19
17
14
13
1500
30
29
29
27
25
22
20
19
16
14
12
11
1750
53
52
50
47
44
40
36
33
30
27
22
20
1500
46
45
43
40
37
34
31
28
26
23
19
17
1750
70
69
67
64
58
55
49
45
41
36
30
27
1500
60
59
57
55
50
47
42
39
35
31
26
23
1750
105
105
105
99
84
76
65
55
50
44
38
35
1500
90
90
90
85
72
65
56
47
43
37
32
30
1750
150
143
134
129
118
108
98
79
72
63
54
49
1500
129
122
115
111
101
92
84
68
62
54
46
42
1750
210
210
210
194
176
149
130
106
98
87
74
68
1500
180
180
180
166
151
128
111
91
84
75
63
58
1750
288
288
288
288
234
205
178
152
140
120
101
97
1500
247
247
247
247
201
176
152
130
120
103
87
83
1750
387
387
387
387
333
283
253
203
187
164
142
139
1500
332
332
332
332
285
242
217
174
160
140
122
119
1750
521
521
521
497
450
396
333
302
269
230
208
192
1500
447
447
447
426
386
339
286
259
231
197
178
164
1750
777
753
690
661
613
565
497
419
386
340
306
282
1500
666
646
592
567
526
484
426
359
331
292
262
242
1750
956
956
956
956
869
782
695
628
546
471
435
401
1500
819
819
819
819
745
670
5596
538
468
404
373
344
216
218
220
222
225
228
232
235
240
245
l AGMA and CITI recommend a minimum Service factor of 2.0 for gear drives in cooling tower fan service when drive by
electric motor or steam turbine.
l *When gear drives are to be selected using a service factor other than 2.0, multiply the 'Service Rating" from the table by
2.0 to get the 'Mechanical Rating is then divided by the appropriate service factor to obtain the
new 'Service Rating' at the require 'Service Factor'.
l Force Lubrication is required for sizes marked Red italics. Contact PREMIUM for additional information.
SIZE
70.030
70.011
75.030
75.011
85.035
85.013
90.035
90.013
100.035
100.013
110.035
110.013
125.040
125.015
140.040
140.015
160.040
160.015
180.040
180.015
200.046
200.017
32.018
32.002
38.018
38.002
45.018
45.002
50.018
50.002
55.030
55.011
60.030
60.011
70.030
70.011
80.030
80.011
90.035
90.013
95.035
95.3013
110.035
110.013
B-214
490 500
265
B-216
540 550
285
B-218
595 615
300
B-220
655 650
325
B-222
710 750
350
B-225
755 785
380
B-228
810 800
415
B-232
1005 915
455
B-235
B-240
B-245
P1
E1
F1
L1
L2
L3
M1
75
68
140
130
435
150
205
370
120
28
25
40
M12
M12
90
83
140
130
500
170
225
410
140
28
30
45
M16
M12
105
95
170
160
540
185
255
450
140
32
30
50
M16
M16
110
100 170
160
600
200
280
490
178
32
30
50
M20
M20
120
110 210
200
665
225
315
540
178
40
40
60
M20
M20
125
115 210
200
705
250
335
600
210
40
40
65
M24
M20
145
135 210
200
711
280
340
610
210
40
40
70
M24
M20
175
165 250
240
1016
318
485
915
270
40
50
80
M30
M20
195
185 300
290
1020
330
480
860
270
50
50
90
M30
M20
210
200 300
290
1130
430
530
960
280
50
50
100 M36
M24
210
200 350
340
1284
485
60
50
110 M36
M30
SIZE
M2
N1
N2
S1
Y1
Z1
Z2
B-214
M12
14
10.0 300
28
60.0
15.0
16
B-216
M12
18
12.0 320
30
70.0
18.0
18
B-218
M16
18
12.0 340
30
70.0
18.0
18
B-220
M16
22
16
360
32
89.0
22.4
22
B-222
M20
22
16
405
32
89.0
22.4
22
B-225
M20
26
20
440
36
105
25.0
26
B-228
M20
26
20
457
36
105
25.0
26
B-232
M24
33
20
486
38
135
35.0
32
B-235
M24
33
20
540
135
35.0
32
B-240
M24 1
39
24
690
140
42.0
36.0
B-245
M24 1
39
24
790
160
46.0
36.0
20.000
19.948
20.000
19.948
22.000
21.948
25.000
24.948
28.000
27.948
28.000
27.948
32.000
31.938
36.000
35.938
40.000
39.938
45.000
44.938
45.000
44.938
10.000
9.964
10.000
9.964
14.000
13.957
14.000
13.957
16.000
15.957
18.000
17.957
20.000
19.948
22.000
21.948
25.000
24.948
25.000
24.948
28.000
27.948
74.5
74.3
79.5
79.3
90.0
89.8
95.0
94.8
106.0
105.8
116.0
115.8
132.0
131.8
148.0
147.7
169.0
168.7
190.0
189.7
210.0
209.7
35.000
34.800
41.000
40.800
48.500
48.300
53.500
53.300
59.000
58.800
64.000
63.800
74.500
74.300
85.000
84.800
95.000
94.800
100.000
99.800
116.000
115.800
4.5
4.3
4.5
4.3
5.0
4.8
5.0
4.8
6.0
5.8
6.0
5.8
7.0
6.8
8.0
7.7
9.0
8.7
10.0
9.7
10.0
9.7
Allowable Thrust Load (kN) on Slow Speed Shaft for B-Series Single Reduction unit. Limited by Output bearing Life (100,000 Hrs L10)
Nominal
Ratio
1.22/1
1.35/1
1.50/1
1.66/1
1.84/1
2.03/1
2.25/1
2.49/1
2.76/1
3.05/1
3.38/1
3.73/1
4.13/1
4.57/1
Nominal
Ratio
1.22/1
1.35/1
1.50/1
1.66/1
1.84/1
2.03/1
2.25/1
2.49/1
2.76/1
3.05/1
3.38/1
3.73/1
4.13/1
4.57/1
Nominal Fan
Speed
1434
1296
1167
1054
951
862
778
703
634
574
518
469
424
383
Nominal Fan
Speed
1230
1111
1000
904
815
739
667
602
544
492
444
402
363
328
Unit Size
B-114
0.3
0.6
1.0
1.3
1.6
1.8
2.0
2.3
2.5
2.7
2.9
3.0
3.2
3.4
B-116
0.3
0.7
1.1
1.4
1.8
1.9
2.0
2.3
2.6
2.8
3.0
3.2
3.4
3.6
B-118
0.4
0.8
1.2
1.5
1.9
2.0
2.1
2.3
2.6
3.0
3.2
3.2
3.5
3.7
B-120
0.6
0.8
1.2
1.6
2.0
2.2
2.3
2.5
2.8
3.3
3.5
3.4
3.7
4.0
B-122
0.7
0.9
1.3
1.8
2.4
2.8
3.4
3.8
4.2
4.6
5.2
5.5
6.0
6.3
B-114
0.3
0.7
1.1
1.4
1.7
1.9
2.2
2.4
2.6
2.8
3.1
3.2
3.4
3.6
B-116
0.4
0.8
1.2
1.6
2.0
2.3
2.5
2.6
2.7
3.1
3.4
3.6
3.9
4.1
B-118
0.6
0.8
1.2
1.6
2.0
2.1
2.1
2.4
2.7
3.1
3.4
3.6
3.9
4.2
B-120
0.7
0.9
1.3
1.8
2.2
2.5
2.6
3.2
3.5
4.2
4.8
5.0
5.2
5.4
B-122
0.8
1.0
1.4
2.1
2.6
3.2
3.7
4.2
4.7
5.1
5.6
6.0
6.4
6.8
B-125
7.7
8.9
10.3
11.4
12.4
13.3
14.2
15.1
16.1
17.0
17.8
18.7
19.6
20.4
B-128
10.1
11.6
13.3
14.6
15.8
17.0
18.1
19.2
20.4
21.4
22.5
23.5
24.6
25.7
B-132
11.9
13.7
15.9
17.5
18.9
20.3
21.7
23.0
24.5
25.8
27.1
28.3
29.6
30.9
B-135
16.3
18.7
21.4
23.4
25.3
27.1
28.9
30.6
32.4
34.1
35.8
37.4
39.1
40.8
B-140
14.
17.0
19.8
22.2
24.3
26.3
28.3
30.2
31.9
34.1
36.0
37.7
39.5
41.4
B-145
22.4
25.4
28.9
31.5
33.6
36.2
38.8
41.2
43.8
46.1
48.7
50.9
53.4
55.8
B-128
10.7
12.3
14.1
15.4
16.7
17.9
19.1
20.2
21.4
22.5
23.7
24.7
25.8
27.0
B-132
12.6
14.6
16.8
18.5
20.0
21.5
22.9
24.3
25.7
27.1
28.5
29.8
31.1
32.5
B-135
17.3
19.8
22.6
24.7
26.7
28.6
30.4
32.2
34.1
35.8
37.6
39.3
41.1
42.9
B-140
15.9
18.1
21.0
23.5
25.7
27.8
29.9
31.9
33.6
35.9
379
39.6
41.6
43.5
B-145
23.8
27.0
30.6
33.3
35.5
38.2
40.9
43.4
46.1
48.6
51.2
53.5
56.1
58.6
Unit Size
B-125
8.2
9.5
11.0
12.1
13.1
14.1
15.0
15.9
16.9
17.8
18.8
19.6
20.5
21.5
Allowable Thrust Load (kN) on Slow Speed Shaft for B-Series Double Reduction unit. Limited by Output bearing Life (100,000 Hrs L10)
Nominal
Ratio
5.06/1
5.60/1
6.20/1
6.86/1
7.59/1
8.4/1
9.3/1
10.3/1
11.4/1
12.6/1
14/1
15.4/1
Nominal
Ratio
5.06/1
5.60/1
6.20/1
6.86/1
7.59/1
8.4/1
9.3/1
10.3/1
11.4/1
12.6/1
14/1
15.4/1
Nominal Fan
Speed
346
313
282
255
231
208
188
170
154
139
125
114
Nominal Fan
Speed
296
268
242
219
196
179
161
146
132
119
107
97
Unit Size
B-214
8.5
8.8
8.8
9.3
9.5
10.0
10.6
11.0
12.1
12.6
13.3
14.0
B-216
9.4
9.6
9.7
10.2
10.7
10.8
11.7
12.5
12.5
13.5
15.2
15.9
B-218
12.7
13.0
13.2
13.5
14.4
14.4
15.5
16.3
16.7
17.9
19.7
20.6
B-220
15.1
15.4
15.0
15.8
17.4
18.5
20.1
21.9
22.8
24.3
26.0
26.9
B-222
16.2
16.6
17.1
17.7
18.6
19.5
20.6
23.7
24.7
26.5
28.5
29.5
B-225
18.1
17.7
17.2
18.9
20.1
22.7
24.7
27.8
29.0
30.6
33.5
34.7
B-228
20.1
20.1
19.1
19.0
23.2
25.5
28.0
30.8
32.1
35.0
38.7
39.5
B-232
32.0
31.5
31.2
31.2
34.8
38.7
41.1
46.5
48.2
51.3
55.3
56.0
B-235
37.3
37.3
36.6
38.0
40.3
43.9
48.9
51.4
54.5
59.1
62.7
65.0
B-240
36.0
37.6
39.4
41.1
42.8
44.7
48.5
54.1
56.3
60.2
64.3
66.8
B-245
64.0
63.8
62.6
62.6
66.0
70.1
74.9
80.3
86.3
92.7
96.5
100.1
B-228
22.1
22.2
21.2
21.1
25.5
27.8
30.4
33.3
34.7
37.6
41.4
42.2
B-232
24.7
34.3
34.1
34.1
37.9
41.8
44.4
49.8
51.6
54.8
59.0
59.8
B-235
40.5
40.6
40.0
41.5
44.0
47.6
52.7
55.4
58.6
63.3
67.0
69.5
B-240
39.4
41.1
43.1
44.9
46.7
48.8
52.7
58.4
60.7
64.8
69.0
71.6
B-245
69.0
68.9
67.9
68.0
71.6
75.8
80.8
86.4
92.6
99.2
103.2
107.0
Unit Size
B-214
9.1
9.5
9.5
10.0
10.2
10.7
11.4
11.8
12.9
13.5
14.2
14.9
B-216
10.1
10.4
10.5
11.1
11.6
11.7
12.6
13.4
13.5
14.6
16.3
16.9
B-218
13.7
14.0
14.3
14.6
15.5
15.6
16.7
17.5
17.9
19.2
21.0
22.0
B-220
16.4
16.7
16.3
17.1
18.8
19.9
21.6
23.5
24.3
25.9
27.6
28.6
B-222
17.6
18.1
18.6
19.2
20.2
21.2
22.3
25.4
26.5
28.3
30.4
31.5
B-225
19.8
19.5
19.0
20.8
22.0
24.6
26.8
29.9
31.1
32.8
35.8
37.1
Unit Size
Nominal
Ratio
B-214
B-216 B-218
B-235 B-240
B-245
5.06/1
5.188
5.124
5.196
5.124
5.112
5.120
5.112
5.124
5.196
5.124
5.112
5.6/1
5.595
5.688
5.707
5.688
5.707
5.782
5.595
5.693
5.623
5.688
5.707
6.2/1
6.273
5.295
6.315
6.379
6.341
6.221
6.295
6.295
6.341
6.379
6.341
6.86/1
6.901
7.011
6.912
6.979
7.034
6.979
6.808
6.966
6.912
6.979
6.912
7.59/1
7.658
7.658
7.554
7.676
7.736
7.676
7.486
7.661
7.601
7.676
7.602
8.4/1
8.437
8.437
8.464
8.476
8.542
8.476
8.267
8.460
8.394
8.476
8.394
9.3/1
9.396
9.396
9.265
9.355
9.428
9.355
9.124
9.337
9.265
9.355
9.265
10.3/1
10.265 10.265 10.125 10.237 10.125 10.455 10.265 10.375 10.499 10.456 10.125
11.4/1
11.489 11.489 11.483 11.276 11.152 11.517 11.307 11.428 11 .565 11.517 11.152
12.6/1
12.748 12.748 12.569 12.567 12.429 12.835 12.601 12.735 12.889 12.835 12.429
14/1
13.928 13.928 13.736 13.982 13.963 13.982 13.963 13.972 13.955 13.982 13.963
15.4/1
15.442 15.442 15.327 15.454 15.432 15.454 15.432 15.509 15.424 15.454 15.433
Net.
Weight (kg)
Gross
Weight (kg)
*Oil Quantity
(Liter)
ABM-118
95
115
ABM-128
205
231
16
ABM-132
386
435
40
ABM-222
715
782
65
ABM-225
890
1005
80
ABM-228
896
1012
80
ABM-232
896
1012
80
* Oil Quantity as mentioned above are for reference only. The units are to be filled up with the exact marking as
per dipstick supplied.
Input Speed
Gear
Fan Speed
*Service Rating
r/min
Ratio
r/min
(k/W)
1750
2.71/1
648
29.0
1500
2.71/1
554
26.0
1750
3.27/1
535
28.0
1500
3.27/1
459
25.0
1750
3.78/1
463
24.0
1500
3.78/1
397
21.0
1750
4.11/1
426
21.0
1500
4.11/1
365
18.5
1750
4.89/1
358
17.0
1500
4.89/1
307
15.0
'Service ratings listed above include a service factor of minimum 2.0 as per AGMA / CTI recommendation for enclosed gear
drives in cooling tower application.
Model : ABM-128
Input Speed
Gear
Fan Speed
*Service Rating
r/min
Ratio
r/min
(k/W)
1750
3.45/1
507
59.0
1500
3.45/1
435
52.0
1750
4.10/1
427
59.0
1500
4.10/1
366
52.0
1750
4.56/1
384
59.0
1500
4.56/1
329
52.0
1750
5.11/1
342
51.0
1500
5.11/1
294
45.0
1750
5.50/1
318
50.0
1500
5.50/1
273
44.0
1750
6.12/1
286
45.0
1500
6.12/1
245
39.5
1750
6.50/1
269
42.0
1500
6.50/1
231
37.0
1750
7.33/1
239
37.0
1500
7.33/1
205
32.5
"Service ratings listed above include a service factor of minimum 2.0 as per AGMA / CTI recommendation for enclosed gear
drives in cooling tower application.
10
Model : ABM-132
Input Speed
Gear
Fan Speed
*Service Rating
r/min
Ratio
r/min
(k/W)
1750
5.77/1
303
66.0
1500
5.77/1
260
58.0
1750
7.71/1
227
51.0
1500
7.71/1
195
45.0
1750
8.66/1
202
43.0
1500
8.66/1
173
38.0
1750
9.83/1
178
34.0
1500
9.83/1
153
30.0
*Service ratings listed above include a service factor of minimum 2.0 as per AGMA / CTI recommendation for enclosed gear
drives in cooling tower application.
11
Model : ABM-222
Input Speed
r/min
Gear
Ratio
Fan Speed
r/min
* Service Rating
(kW)
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
6.47/1
6.47/1
7.89/1
7.89/1
8.80/1
8.80/1
10.16/1
10.16/1
11.18/1
11.18/1
12.93/1
12.93/1
270
232
222
190
199
170
172
148
157
134
135
116
140
120
140
120
140
120
140
120
140
120
140
120
'Service ratings listed above include a service factor of minimum 2.0 as per AGMA / CTI recommendation for enclosed gear
drives in cooling tower application
12
Model
ABM-225
ABM-228
ABM-232
Model
13
C (mm)
Input Speed
Gear
Fan Speed
*Service Rating
r/min
Ratio
r/min
(kW)
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
1750
1500
8.85/1
8.85/1
10.28/1
10.28/1
11.18/1
11.18/1
13.00/1
13.00/1
9.65/1
9.65/1
10.83/1
10.83/1
11.55/1
11.55/1
12.98/1
12.98/1
14.84/1
14.84/1
11.44/1
11.44/1
198
169
170
146
157
134
135
115
181
156
162
139
152
130
135
116
118
101
153
131
156
134
156
134
156
134
156
134
217
186
204
175
191
164
191
164
174
149
217
186
D (mm)
E (mm)
F (Keyway)
I (mm)
ABM-225
867
222
105.66 (4.160")
1 X 5/8 X 6
60.325 (2.375")
ABM-228
862
200
158.17 (6.227")
1 X X 7
66.675 (2.625")
ABM-232
862
200
158.17 (6.227")
1 X X 7
66.675 (2.625")
* Service Ratings listed above include a service factor of minium 2.0 as per AGMA / CTI recommendation for enclosed gear drives in cooling tower fan service.
3
8
7
4
6
1
ITEM NO.
1
DESCRIPTION
QTY.
01
BEVEL WHEEL
01
OUTPUT SHAFT
01
INPUT BEARING
02
OUTPUT BEARING
02
01
02
01
5
11
10
2
3
12
6
9
1
4
8
ITEM NO.
1
2
3
4
5
6
7
8
9
10
11
12
DESCRIPTION
INPUT SHAFT WITH BEVEL PINION
BEVEL WHEEL
HELICAL PINION SHAFT
OUTPUT WHEEL
OUTPUT SHAFT
INPUT BEARING
INTERMEDIATE BEARING
OUTPUT BEARING
INPUT OIL SEAL
OUTPUT OIL SEAL
WATER SLINGER (LABYRINTH)
OIL SLINGER
QTY.
01
01
01
01
01
02
02
02
01
02
01
01
14
TRAXOL
G-32