Você está na página 1de 4

STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton

Project

Perencanaan Desain Awal dan Detail Design Jalan Tol Terbanggi Besar Pematang
No. Test
Panggang Kayu Agung

Location

Basic Design Planning and Detail Design for Terbanggi Besar Pematang Panggang
GL
Kayu Agung Tol Road

Tested by

Petrus.M. team, (pmtes.com)

GWL

- 8.00 m

Date of Test

6 AGUSTUS
2016

Area of Cone
STA =

DEPTH (M)
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
2.20
2.40
2.60
2.80
3.00
3.20
3.40
3.60
3.80
4.00
4.20
4.40
4.60
4.80
5.00
5.20
5.40
5.60
5.80
6.00
6.20
6.40
6.60
6.80
7.00
7.20
7.40
7.60
7.80
8.00
8.20
8.40
8.60
8.80
9.00
9.20
9.40
9.60
9.80
10.00
10.20
10.40
10.60
10.80
081213288147

10 cm^2

Area of Mantle

150 cm^2

S-2

139+800
READING PRESURE
GAUGE
x kgf

y kgf

CONE
RESISTANCE
(qc) kg/cm2

0
0
16
18
20
18
20
18
16
14
20
22
26
30
36
28
32
42
50
58
60
65
75
80
58
68
70
80
85
75
60
58
42
36
30
32
36
38
40
42
40
42
48
48
40
48
56
60
65
60
65
75
75
90
95

0
0
26
28
32
30
34
30
28
28
30
34
38
44
48
40
46
48
56
68
68
70
80
85
90
80
78
85
95
100
90
75
66
54
48
40
46
48
48
50
50
50
54
54
56
50
62
68
74
80
75
80
90
100
105

0
0
16
18
20
18
20
18
16
14
20
22
26
30
36
28
32
42
50
58
60
65
75
80
58
68
70
80
85
75
60
58
42
36
30
32
36
38
40
42
40
42
48
48
40
48
56
60
65
60
65
75
75
90
95

LOKAL
FRICTICION
(fs) kg/cm2
0.00
0.00
1.00
1.00
1.20
1.20
1.40
1.20
1.20
1.40
1.00
1.20
1.20
1.40
1.20
1.20
1.40
0.60
0.60
1.00
0.80
0.50
0.50
0.50
3.20
1.20
0.80
0.50
1.00
2.50
3.00
1.70
2.40
1.80
1.80
0.80
1.00
1.00
0.80
0.80
1.00
0.80
0.60
0.60
1.60
0.20
0.60
0.80
0.90
2.00
1.00
0.50
1.50
1.00
1.00

pmtes.com

TOTAL LOKAL
TOTAL
FRICTION
FRICTION
(Lf) Kg/cm
(Tf) kg/cm
0
0
20
20
24
24
28
24
24
28
20
24
24
28
24
24
28
12
12
20
16
10
10
10
64
24
16
10
20
50
60
34
48
36
36
16
20
20
16
16
20
16
12
12
32
4
12
16
18
40
20
10
30
20
20

0
0
20
40
64
88
116
140
164
192
212
236
260
288
312
336
364
376
388
408
424
434
444
454
518
542
558
568
588
638
698
732
780
816
852
868
888
908
924
940
960
976
988
1000
1032
1036
1048
1064
1082
1122
1142
1152
1182
1202
1222

fs / qc (%)

6.25
5.56
6.00
6.67
7.00
6.67
7.50
10.00
5.00
5.45
4.62
4.67
3.33
4.29
4.38
1.43
1.20
1.72
1.33
0.77
0.67
0.63
5.52
1.76
1.14
0.63
1.18
3.33
5.00
2.93
5.71
5.00
6.00
2.50
2.78
2.63
2.00
1.90
2.50
1.90
1.25
1.25
4.00
0.42
1.07
1.33
1.38
3.33
1.54
0.67
2.00
1.11
1.05

petrus.petergo@gmail.com

STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton


Project

Perencanaan Desain Awal dan Detail Design Jalan Tol Terbanggi Besar Pematang
No. Test
Panggang Kayu Agung

Location

Basic Design Planning and Detail Design for Terbanggi Besar Pematang Panggang
GL
Kayu Agung Tol Road

Tested by

Petrus.M. team, (pmtes.com)

GWL

- 8.00 m

Date of Test

6 AGUSTUS
2016

Area of Cone
STA =

DEPTH (M)
11.00
11.20
11.40

081213288147

10 cm^2

Area of Mantle

150 cm^2

S-2

139+800
READING PRESURE
GAUGE
x kgf

y kgf

CONE
RESISTANCE
(qc) kg/cm2

105
120
120

115
125
130

105
120
120

LOKAL
FRICTICION
(fs) kg/cm2
1.00
0.50
1.00

pmtes.com

TOTAL LOKAL
TOTAL
FRICTION
FRICTION
(Lf) Kg/cm
(Tf) kg/cm
20
10
20

1242
1252
1272

fs / qc (%)
0.95
0.42
0.83

petrus.petergo@gmail.com

STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton


Project

Perencanaan Desain Awal dan Detail Design Jalan Tol Terbanggi Besar Pematang
No. Test
Panggang Kayu Agung

Location

Basic Design Planning and Detail Design for Terbanggi Besar Pematang Panggang
GL
Kayu Agung Tol Road

Tested by

Petrus.M. team, (pmtes.com)

GWL

- 8.00 m

Date of Test

6 AGUSTUS
2016

Area of Cone
STA =

DEPTH (M)
11.60
11.80
12.00
12.20
12.40
12.60
12.80
13.00
13.20
13.40
13.60
13.80
14.00
14.20
14.40
14.60
14.80
15.00
15.20
15.40
15.60
15.80
16.00
16.20

081213288147

10 cm^2

Area of Mantle

150 cm^2

S-2

139+800
READING PRESURE
GAUGE
x kgf

y kgf

CONE
RESISTANCE
(qc) kg/cm2

120
110
100
105
105
130
130
140
135
135
135
165
160
155
155
155
185
175
160
150
160
170
180
250

125
135
120
115
110
135
140
160
150
140
145
180
170
160
160
175
190
180
175
165
175
185
195
251

120
110
100
105
105
130
130
140
135
135
135
165
160
155
155
155
185
175
160
150
160
170
180
250

LOKAL
FRICTICION
(fs) kg/cm2
0.50
2.50
2.00
1.00
0.50
0.50
1.00
2.00
1.50
0.50
1.00
1.50
1.00
0.50
0.50
2.00
0.50
0.50
1.50
1.50
1.50
1.50
1.50
0.10

pmtes.com

TOTAL LOKAL
TOTAL
FRICTION
FRICTION
(Lf) Kg/cm
(Tf) kg/cm
10
50
40
20
10
10
20
40
30
10
20
30
20
10
10
40
10
10
30
30
30
30
30
2

1282
1332
1372
1392
1402
1412
1432
1472
1502
1512
1532
1562
1582
1592
1602
1642
1652
1662
1692
1722
1752
1782
1812
1814

fs / qc (%)
0.42
2.27
2.00
0.95
0.48
0.38
0.77
1.43
1.11
0.37
0.74
0.91
0.63
0.32
0.32
1.29
0.27
0.29
0.94
1.00
0.94
0.88
0.83
0.04

petrus.petergo@gmail.com

STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton


Project

Perencanaan Desain Awal dan Detail Design Jalan Tol Terbanggi Besar Pematang
No. Test
Panggang Kayu Agung

Location

Basic Design Planning and Detail Design for Terbanggi Besar Pematang Panggang
GL
Kayu Agung Tol Road

Petrus.M. team, (pmtes.com)

GWL

- 8.00 m

Date of Test

6 AGUSTUS
2016

Tested by

10 cm^2

Area of Cone

Area of Mantle

150 cm^2

S-2

139+800

STA =

CPT SONDIR

0.0

-5.0

Depth (m)

-10.0

-15.0

-20.0

-25.0

-30.0

081213288147

qc kg/cm2

50

100

150

200

250

TF kg/cm

500

1000

1500

2000

2500

LF kg/cm2 0,5

1,0

1,5

2,0

2,5

pmtes.com

petrus.petergo@gmail.com

Você também pode gostar