Você está na página 1de 2

ANNEXURE - E

Guidelines for Grid connectivity of Solar RTPV systems:


1. The interested applicants of domestic, commercial, educational institutions,
industrial establishments etc, who are consumers of BESCOM can submit on line / off line applications for installing SRTPV power plants duly paying the
registration fee along with necessary documents such as latest Electricity bill,
declaration for not availing the subsidy from MNRE.
2. The rooftop/terrace must have easy access. The roof of the building should not
be less than 10 feet height. The PV module shall be mounted on the roof of the
building.
3. The fee payable are as follows:
Sl.No. Capacity of proposed SRTPV plant

Registration
fee

Facilitation
fee

Rs.500/-

Rs.1000/-

1.

Upto and inclusive of 5.0 kWp

2.

Above 5.0 kWp and below 50 kWp

Rs.1000/-

Rs.2000/-

3.

Above 50 kWp and up to 1000 kWp

Rs.2000/-

Rs.5000/-

4. The AEE, C, O&M Sub-Division is the signing authority for PPA up to installed
capacity of 50kWp and EE, C, O&M Division is the signing authority for PPA if
the proposed SRTPV capacity is 50kWp and above.
5. If the proposed capacity of SRTPV is more than 500kWp, draft Power Purchase
Agreement is to be submitted to GM, DSM, Corporate office for onward
submission to Commission for draft PPA approval.
6. The sub-divisional officer shall be nodal point of contact for Solar RTPV
program.
7. The applicant can select any PV modules and
install the SRTPV System.

reputed system installer to

8. Only BESCOM empanelled Grid tied inverter and meter should be used.
9. The Sub-divisional officers are empowered
commissioning of SRTPV systems upto 10kWp.

to

accord

approval

for

10. Approval of Electrical Inspectorate, Government of Karnataka is required for


commissioning of SRTPV systems above 10kWp.

11. The sub divisional officers are empowered to service the SRTPV systems upto
5kWp and above 5kWp SRTPV plant is to be commissioned with the assistance
of MT staff.
12. The up-gradation of infrastructure upto the point of interconnectivity should be
carried by the SRTPV consumer at their own cost under prevailing conditions
of deposit contribution work. i.e service line, meter, metering cubicle, CT s,
Transformer.
13. The upgradation of infrastructure beyond the point of interconnectivity is to be
taken up by the BESCOM, if required.
14. The check meter should be provided for SRTPV systems capacity of more than
20kWp.
15. BESCOM approved meters, CTs, PTs and metering cubicle shall be provided.
16. The 3 phase 4 wire metering system should be provided if the existing metering
system is of 3 phase 3 wire system.
17. Interconnection voltages as per KERC:
Sl.
No.

System Capacity

Voltage level

Upto & inclusive 5 kWp

240 Volts

Above 5 kWp to upto 50 kWp

415 Volts

Above 50 kWp & above upto 500 kWp

11 KV

18. It is the total responsibility of the SRTPV applicant for planning, design,
construction, reliability, protection and safe operation of all the equipments
subject to the regulations for construction, operation maintenance,
connectivity and other statutory provisions as per CEA guide lines.
19. The Technical, safety, grid connectivity standards are to be followed as per the
technical standards.
20. BESCOM personnel reserve the right to inspect the entire plant routinely at
any time as per the distribution code approved by KERC.
21. The consumer shall pay the Electricity tax and other statutory levies,
pertaining to SRTPV generation, as levied from time to time.
22. Solar meter reading will be taken for statistical purpose only in net-metering
systems.