Você está na página 1de 3

QUOTATION: DFMZ2170134

DATE: January 26, 2017

Quotation Addressed To:

Purchase Order To Be Made To:

Aashish Gaurav
University of Waterloo
200 University Avenue,
Waterloo, ON,,
N2L 3G1

BCA Scientific Inc.


178 Rushton Road,
Toronto, ON, M6G 3J3
Fax: 905*820*8958

ONE (1) X DESIGN FILTRATION MODEL # EXT-04-DC, CLASS 1, TWO-STAGE CARBON,


EXTRACTION HOOD (4 FT)
Features include:

o
o
o
o
o
o
o
o
o
o
o
o

Unit Price

Nominal exterior dimensions - 44" wide x 23" deep x 44" high


Nominal interior dimensions - 43" wide x 22" deep x 23" high
Constructed from corrosion resistant 1/2" seam welded white
polypropylene
Variable solid state speed control
Two stage chemical filter system to remove customer specific chemicals
Removable front panel for quick and easy chemical tray changes
Quick change disposable MERV 7 pre-filter located prior to Carbon filters
Energy efficient T8 fluorescent light fixture
Lighted on/off switches for motor and fluorescent light
10" hand opening
Fully opening vertical rising clear acrylic face shield
Pass thru grommet located on side panel for passing electrical cords

$8,925.00

Optional Accessories:

EXT-4W - Stainless steel work surface - 18 gauge, type 304, #4 finish

$480

EXT-04B - Painted steel knock down base frame - 30" working height
EXT-04BA - Painted steel knock down base frame for - 36" working
height
EXT-C4 - Castors to form mobile unit
EXT-D1 - GFI duplex outlet located on interior side panel - each
AL-200 - Digital alarm package - monitors hood face velocity
SV-01 - Service valve located on side panel (Air, gas, vacuum) - each

$1350

Page 1 of 2

$1350
$450
$300
$1250
$300

QUOTATION # DFMZ2170134

DESIGN FILTRATION INC. MODEL # EXT-04-DC


TWO STAGE CARBON EXTRACTION HOOD

TERMS:
1) Prepayment in full prior to shipment, CDN funds.
2) Delivery point - FOB your dock, tailgate delivery.
3) Estimated delivery 5-7 weeks, after approved submittals.
4) Customer to specify list of chemicals to be used in extraction hood, to supplement manufacturer
recommendation for specific chemical filter required.
5) HST extra if applicable.
WARRAN TY: One (1) year parts and labor.
SIGNED: Ashley Coon, P.Eng.

DISCLAIMER / LIMIT OF LIABILITY CHEMICAL FILTER PREVENTATIVE MAINTENANCE

DESIGN FILTRATION MICROZONE INC (manufacturer) and BCA SCIENTIFIC INC (distributor) recommend regular preventative
maintenance for chemical extraction hoods.

The chemical filters used in this extraction hood, must be checked and replaced regularly by the customer to ensure they are not
loaded and have sufficient adsorption/absorption capacity.

The life expectancy of the filters is dependant on usage, including volume, concentration and type of chemicals used, in addition
to the age of chemical filters. When in doubt, the chemical filters should be replaced. Only use replacement chemical filters
recommended by the manufacturer Design Filtration Microzone Inc for your particular application.

The customer is required to set-up a preventative maintenance schedule and agrees to assume all responsibility for care,
maintenance and required change-out of chemical filters. Should the customer require the name of a service company to provide
on-going preventative maintenance, testing and/or replacement of chemical filters, they should contact Design Filtration
Microzone Inc @ 1-888-636-8609 for a list of recommended service companies.

In no event will Design Filtration Microzone Inc (manufacturer) or BCA Scientific Inc (distributor) be liable for any damages
whatsoever, including, but not limited to any direct, incidental, consequential, special, exemplary or other indirect damages arising
out of the use of this equipment.

Você também pode gostar