Você está na página 1de 102

M 20 C

Project Guide Generator Set

Contents

Introduction

Information for the user of this project guide


The project information contained in the following is not binding, since technical data of products
may especially change due to product development and customer requests. Caterpillar reserves the
right to modify and amend data at any time. Any liability for accuracy of information provided herein
is excluded.
Binding determination of data is made by means of the Technical Specication and such other agreements as may be entered into in connection with the order. We will supply further binding data, drawings, diagrams, electrical drawings, etc. in connection with a corresponding order.
This edition supersedes the previous edition of this project guide.
All rights reserved. Reproduction or copying only with our prior written consent.

Caterpillar Motoren GmbH & Co. KG


P. O. Box, D-24157 Kiel
Germany
Phone
+49 431 3995-01
Telefax
+49 431 3995-2193

Edition

M 20 C Generator Set - 08.2012

August 2012

Marine Financing Guidelines


Power :
Cat and MaK.
Financial Products: Construction, term
and repower financing.
Repayment :
Loan terms up to
10 years, with longer
amortizations available.
Financed Amount : Up to 80 % of your
vessel cost.
Rates :
Fixed or variable.
Currency :
US Dollars, Euros and
other widely traded
currencies.

II

Global Resource from One Source


When you select Cat Marine Power for your
vessel, look to Cat Financial for world-class
financial support. With marine lending offices in
Europe, Asia and the US supporting Caterpillars
worldwide marine distribution network, Cat
Financial is anchored in your homeport. We also
have over 20 years of marine lending experience,
so we understand your unique commercial
marine business needs. Whether youre in the
offshore support, cargo, ship assist, towing, fishing or passenger vessel industry, you can count
on Cat Financial for the same high standard you
expect from Caterpillar.
www.CAT.com / CatMarineFinance
Visit our web-site or see your local Cat dealer
to learn how our marine financing plans and
options can help your business succeed.

M 20 C Generator Set - 08.2012

Commissioning
Training

DICARE
Diagnostic Software

Global
Dealer Network

Remanufactured
Parts

Maintenance

Genuine
Spare Parts

Engine
Upgrades

Overhauls

Repairs
Customer Support
Agreements
( CSAs )

Providing integrated solutions for your power system means


much more than just supplying your engines. Beyond complete
auxiliary and propulsion power systems, we offer a broad portfolio of customer support solutions and financing options. Our
global dealer network takes care of you wherever you are
worldwide. Localized dealers offer on-site technical expertise
through marine specialists and an extensive inventory of all the
spare parts you might need.

To find your nearest dealer, simply go to:


MARINE.CAT.COM

M 20 C Generator Set - 08.2012

III

IV

M 20 C Generator Set - 08.2012

Contents

Page

1.

Engine description

1.1

Engine description ...............................................................................................................

1.2

Engine design features ........................................................................................................

2.

General data and operation of the engine

2.1
2.1.1
2.1.2
2.1.3
2.1.4
2.1.5

General data and outputs ....................................................................................................


Output denition ....................................................................................................................
Fuel consumption ..................................................................................................................
Lube oil consumption ...........................................................................................................
Nitrogen oxide emissions (NOx values) IMO II .................................................................
Technical data .......................................................................................................................

3
3
4
4
4
5

2.2
2.2.1

Engine dimensions ...............................................................................................................


Turbocharger at free end .....................................................................................................

7
7

2.3

Restrictions for low load operation ..................................................................................

2.4
2.4.1
2.4.2
2.4.3

Load application and recovery behaviour .......................................................................


Standard loading up procedure ..........................................................................................
Speed control of auxiliary generating sets / DE-drive ....................................................
Speed control of auxiliary generating sets .......................................................................

9
11
12
12

3.

Systems

3.1
3.1.1
3.1.2
3.1.3
3.1.4

Combustion air system ........................................................................................................


General....................................................................................................................................
Air intake from engine room (standard) ............................................................................
Air intake from outside .........................................................................................................
Radiated heat .........................................................................................................................

M 20 C Generator Set - 08.2012

13
13
13
13
13

3.2
3.2.1
3.2.2
3.2.3

Starting air system ...............................................................................................................


Starting air quality requirements ........................................................................................
System diagram .....................................................................................................................
Starting air system components .........................................................................................
a) Receiver capacity acc. to GL recommendation AT1/AT2 ..........................................
b) Compressor AC1/AC2 ......................................................................................................
c) Air starter (tted) AM1 ....................................................................................................

14
14
15
16
16
17
17

3.3
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5

Exhaust system .....................................................................................................................


General....................................................................................................................................
Exhaust expansion joint .......................................................................................................
Silencer ...................................................................................................................................
Exhaust gas boiler (if needed) ............................................................................................
Turbocharger cleaning device ............................................................................................

17
17
17
18
19
20

3.4
3.4.1
3.4.2
3.4.3
3.4.4

3.4.5

Cooling water system ..........................................................................................................


Cooling water quality requirements ...................................................................................
System diagram Heat balances ......................................................................................
System diagram Cooling water system ..........................................................................
Cooling water system components ....................................................................................
a) LT cooling water pump (tted on engine) FP2.............................................................
b) LT cooling water stand-by pump (optional) FP6 .........................................................
c) HT cooling water pump (tted) FP1 ..............................................................................
d) HT cooling water stand-by pump (optional) FP5 ........................................................
e) HT temperature controller (separate) FR1...................................................................
f) LT temperature controller (separate) FR2....................................................................
g) HT ow temp. controller (separate; option: in case of HT heat recovery) FR3 .....
h) Pre-heater (tted) FH5/FP7.............................................................................................
i) HT cooler (separate) FH1................................................................................................
j) LT cooler (separate) FH2 .................................................................................................
k) Header tank FT2 ...............................................................................................................
Recommendation for cooling water system .....................................................................

21
21
22
25
26
26
26
26
26
26
27
27
27
27
27
27
28

3.5
3.5.1
3.5.2
3.5.3

Fuel oil system, MGO/MDO operation ..............................................................................


Quality requirements for MGO/MDO fuel/permitted fuels .............................................
System diagram Fuel oil system, MGO operation ........................................................
System diagram Fuel oil system, MDO operation ........................................................

29
29
30
31

VI

M 20 C Generator Set - 08.2012

3.5.4

MGO/MDO fuel system components .................................................................................


a) Fine lter (tted) DF1 .......................................................................................................
b) Strainer (separate) DF2...................................................................................................
c) Pre-heater (separate) DH1 .............................................................................................
d) MGO/MDO cooler DH3....................................................................................................
e) Feed pump (tted) DP1....................................................................................................
f) Feed pump (separate) DP1 .............................................................................................
g) MGO/MDO service tank DT1..........................................................................................
h) Separator DS1 ..................................................................................................................

32
32
32
32
32
32
32
33
33

3.6
3.6.1
3.6.2
3.6.3
3.6.4

Fuel oil system, HFO operation ..........................................................................................


Requirements for residual fuels for diesel engines (as bunkered) ...............................
Viscosity / temperature diagram ........................................................................................
System diagram Heavy fuel oil operation ......................................................................
HFO system components .....................................................................................................
a) Fine lter (tted) HF1 .......................................................................................................
b) Strainer HF2 ......................................................................................................................
c) Self cleaning lter HF4 ....................................................................................................
d) Viscosimeter HR2 .............................................................................................................
e) Pressure pumps HP1/HP2 ..............................................................................................
f) Circulating pumps HP3/HP4 ...........................................................................................
g) Pressure regulating valve HR1 ......................................................................................
h) Final preheater HH1/HH2 ................................................................................................
i) Mixing tank HT2 ...............................................................................................................
j) Bunker tanks .....................................................................................................................
k) Settling tanks HT5/HT6....................................................................................................
l) Day tank DT1/HT1 ............................................................................................................
m) Separators HS1/HS2........................................................................................................
System diagram Standard HFO supply and booster module ......................................
Standard heavy fuel oil supply and booster module .......................................................
a) Primary lter FIL1 .............................................................................................................
b) Fuel pressure pumps SP1/SP2.......................................................................................
c) Pressure regulating system PCV1.................................................................................
d) Self cleaning ne lter AF1 ............................................................................................
e) Consumption measuring system FLOW1 .....................................................................
f) Mixing tank with accessories T1 ..................................................................................
g) Circulating pumps BP1/BP2 ...........................................................................................
h) Final preheater H1/H2 .....................................................................................................
i) Viscosity control system VA1.........................................................................................
j) Cooler CL1 .........................................................................................................................

34
34
35
36
37
37
37
38
38
38
38
39
39
39
40
40
40
40
41
42
42
42
42
42
42
42
42
42
42
42

3.6.5
3.6.6

M 20 C Generator Set - 08.2012

VII

3.7
3.7.1
3.7.2
3.7.3

3.7.4

Lube oil system .....................................................................................................................


Quality requirements of lube oil ..........................................................................................
System diagram Lube oil system .....................................................................................
Lube oil system components ...............................................................................................
a) Force pump (tted) LP1 ...................................................................................................
b) Prelubrication pump (tted) LP5....................................................................................
c) Stand-by force pump (separate) LP2 ............................................................................
d) Strainer LF4 .......................................................................................................................
e) Self cleaning lter (tted) LF2 ........................................................................................
f) Cooler (tted) LH1 ............................................................................................................
g) Temperature controller LR1............................................................................................
h) Crankcase ventilation C91 ..............................................................................................
i) Separator; treatment at MGO/MDO operation LS1 ....................................................
j) Separator; treatment at HFO operation LS1 ................................................................
Recommendation for lube oil system ................................................................................

4.

Connecting parts engine

4.1

Power take-off ......................................................................................................................

50

4.2
4.2.1
4.2.2
4.2.3

Resilient mounting of baseframe .......................................................................................


Major components ................................................................................................................
Foundation ..............................................................................................................................
Structure-borne sound level LV ...........................................................................................

51
51
52
55

4.3

Generators structural requirements for MaK diesel gensets M 20 C .........................

56

5.

Installation and arrangement

5.1

General installation aspect ................................................................................................

57

5.2

System connections engine ...............................................................................................

58

5.3

Space requirement for dismantling of charge air cooler and turbocharger cartridge 59

VIII

44
44
46
47
47
47
47
47
47
48
48
48
48
48
49

M 20 C Generator Set - 08.2012

5.4

Installation of exible pipe connections .........................................................................

60

5.5

Notes regarding installation exhaust system .................................................................

60

5.6

Installation of crankcase ventilation on the engine ......................................................

61

5.7

Earthing of the engine ..........................................................................................................

62

5.8

Lifting of the engine .............................................................................................................

63

6.

Control and monitoring system

6.1

Engine control panel ............................................................................................................

64

6.2

Genset control .......................................................................................................................

65

6.3

Engine monitoring ................................................................................................................

66

6.4

Measuring points ..................................................................................................................

67

6.5

Local and remote indicators ...............................................................................................

72

6.6

LESS: Large Engine Safety System ....................................................................................

73

7.

Diagnostic trending monitoring DICARE..................................................

75

8.

Engine acceptance test ..................................................................................

77

9.

Engine International Air Pollution Prevention Certicate .......................

78

M 20 C Generator Set - 08.2012

IX

10.

Painting / preservation ...................................................................................

79

11.

Engine parts ......................................................................................................

82

12.

Caterpillar Marine Systems Integration......................................................

83

12.1

The Scope ..............................................................................................................................

83

13.

Appendix ...........................................................................................................

84

13.1
13.1.1
13.1.2
13.1.3

Exhaust system .....................................................................................................................


Resistance in exhaust gas piping .......................................................................................
Exhaust data ..........................................................................................................................
Exhaust gas sound power level ..........................................................................................

84
84
85
87

13.2

Air-borne sound power level..............................................................................................

89

M 20 C Generator Set - 08.2012

1.

Engine description

1.1

Engine description

The M 20 C is a four-stroke diesel engine, non-reversible, turbocharged and intercooled with direct
fuel injection.

In-line engine M 20 C

Cylinder conguration:
Bore:
Stroke:
Stroke/bore ratio:
Swept volume:
Output/cyl.:
BMEP:
Revolutions:
Mean piston speed:
Turbocharging:
Direction of rotation:

6,8,9 in-line
200 mm
300 mm
1.5
9.4 l/Cyl.
170/190 kW
24.1/24.2 bar
900/1,000 rpm
9.0/10.0 m/s
constant pressure system
counter-clockwise,
viewed from the driving end

6 5 4 3

2 1

Free end

Cyl. number

Driving end

Control side

Exhaust side
M 20 C Generator Set - 08.2012

1.

Engine description

1.2

Engine design features

Designed for heavy fuel operation up to 700 cSt/50C, fuel grade acc. to CIMAC H55 K55, ISO
8217, 2010 (E), ISO-F-RMH55 RMK55.
1-piece dry engine block made of nodular cast iron. It includes the crankshaft bearing, camshaft
bearing, charge air duct, vibration damper housing and gear drive housing.
Underslung crankshaft with corrosion resistant main and big end bearing shells.
Natural hardened liners, centrifugally cast, with calibration insert.
Composite type pistons with steel crown and aluminium alloy skirt.
Piston ring set consisting of 2 chromium plated compression rings, rst ring with chromium-ceramic
layer and 1 chromium plated oil scraper ring. Two ring grooves are hardened and located in the
steel crown.
2-piece connecting rod, fully machined, obliquely split with serrated joint.
Cylinder head made of nodular cast iron with 2 inlet and 2 exhaust valves with valve rotators.
Directly cooled exhaust valve seats.
Camshaft consisting of individual cylinder sections allowing a removal of the pieces sideways.
Turbocharger supplied with integrated plain bearings lubricated by engine lubricating oil.
No water cooling for turbocharger.
2-circuit fresh water cooling system with single charge air cooler.
Nozzle cooling for heavy fuel operation with engine lubricating oil.

M 20 C Generator Set - 08.2012

2.

General data and operation of the engine

6 M 20 C
8 M 20 C
9 M 20 C

900 rpm / 60 Hz
Engine
Generator
kW
kWe
1,020
979
1,360
1,305
1,530
1,469

1,000 rpm / 50 Hz
Engine
Generator
kW
kWe
1,140
1,094
1,520
1,459
1,710
1,641

Remark:
The generator outputs are based on 96% efciency and a power factor of 0.8.
Engine output 180/200 kW/cyl. at 900/1,000 rpm ask for availability!

2.1

General data and ouputs

2.1.1 Output denition


The maximum continuous rating stated by Caterpillar refers to the following reference conditions
according to IACS (International Association of Classication Societies) for main and auxiliary engines:
Reference conditions according to IACS (tropical conditions):
Air pressure
100 kPa (1 bar)
Air temperature
318 K (45C)
Relative humidity
60 %
Seawater temperature
305 K (32C)
The permissible overload is 10 % for one hour every twelve hours. The maximum fuel rack position is
limited to 110 % continuous rating.

M 20 C Generator Set - 08.2012

2.

General data and operation of the engine

2.1.2 Fuel consumption


The fuel consumption data refer to the following reference conditions:
Intake temperature
298 K (25C)
Charge air temperature
318 K (45C)
Charge air coolant inlet temperature
298 K (25C)
Net heating value of the diesel oil
42,700 kJ/kg
Tolerance
5%
Specication of the fuel consumption data without engine driven pumps; for each tted pump an
additional consumption of 1 % has to be calculated.

2.1.3 Lube oil consumption


Actual data can be taken from the technical data.

2.1.4 Nitrogen oxide emissions (NOx values) IMO II


NOx limit values according to MARPOL 73/78 Annex VI:

9.20 g/kWh (n = 900 rpm)


9.00 g/kWh (n = 1,000 rpm)

Generator according to cycle D2:

8.80 g/kWh (n = 900 rpm)


8.80 g/kWh (n = 1,000 rpm)

M 20 C Generator Set - 08.2012

2.

General data and operation of the engine

2.1.5 Technical data


Performance Data
Maximum continuous rating acc. ISO
3046/1
Speed
Minimum speed
Brake mean effective pressure
Charge air pressure
Firing pressure
Combustion air demand (ta = 20C)
Specic fuel oil consumption
100%
n = const 1)
85%
75%
50%
2)
Lube oil consumption
NOx-emission 6)
Turbocharger type
Fuel
Engine driven booster pump
Stand-by booster pump
Mesh size MDO ne lter
Mesh size HFO automatic lter
Mesh size HFO ne lter
Lubricating Oil
Engine driven pump
Independent pump
Working pressure at engine inlet
Independent suction pump
Primimg pump pressure/suction pump
Sump tank content/dry sump content
Temperature at engine inlet
Temperature controller NB
Double lter NB
Mesh size double lter
Mesh size automatic lter
M 20 C Generator Set - 08.2012

Cylinder

kW

1,020

1,140

1,360

1,520

1,530

1,710

1/min
1/min
bar
bar
bar
m/h

900
280
24.06
3.3

1,000
300
24.2
3.4

900
280
24.06
3.3

1,000
300
24.2
3.4

900
280
24.06
3.3

1,000
300
24.2
3.4

9,485

185
10,395 10,663

g/kWh
g/kWh
g/kWh
g/kWh
g/kWh
g/kWh

187
-/186
-/188
-/199

m/h/bar
m/h/bar
mm
mm
mm

185
6,135

185
6,790

190
189/189
189/190
191/198
0.6
8.5
KBB HPR4000
1.2/5
0.8/10
0.025
0.010
0.034

9,240
187
-/186
-/188
-/199

190
189/189
189/190
191/198
0.6
8.5
KBB HPR5000
1.2/5
1.0/10
0.025
0.010
0.034

187
-/186
-/188
-/199

190
189/189
189/190
191/198
0.6
8.5
KBB HPR5000
1.2/5
1.2/10
0.025
0.010
0.034

m/h/bar 52.5/10 58.8/10 52.5/10 58.8/10 52.5/10 58.8/10


m/h/bar
35/10
45/10
45/10
bar
4-5
4-5
4-5
m/h/bar

m/h/bar
5/5/8/3
8/5/10/3
8/5/10/3
m
1.7/0.5
2.3/0.5
2.6/0.5
C
55 - 65
55 - 65
55 - 65
mm

mm
65/65
65/65
65/65
mm

mm
0.03
0.03
0.03
5

2.

General data and operation of the engine


Fresh water cooling

Cylinder

Engine content
Pressure at engine inlet min/max
Header tank capacity
Temperature at engine outlet
Two-circuit system
Engine driven pump HT
Independent pump HT
HT-controller NB
Water demand LT-charge air cooler
Temperature at LT-charger air cooler inlet
Heat dissipation
Specic jacket water heat
Specic lube oil heat
Lube oil cooler
Jacket water
Charge air cooler 3)
Heat radiation engine
Exhaust gas
Silencer/spark arrestor NB 25 dBA
Pipe diameter NB after turbine
Maximum exhaust gas pressure drop
Exhaust gas temp after turbine (25C
intake air) 5)
Exhaust gas mass ow (25C intake air) 5)
Exhaust gas temp after turbine (45C
intake air) 5)
Exhaust gas mass ow (45C intake air) 5)
Starting air
Starting air pressure max.
Minimum starting air pressure
Air consumption per start 4)
Max. crankcase pressure, nominal
diameter ventilation pipe

m
bar
m
C

0.12
2.5/6.0
0.1
80 - 90

0.16
2.5/6.0
0.1
80 - 90

0.18
2.5/6.0
0.1
80 - 90

1)

2)
3)
4)
5)
6)

m/h/bar
m/h/bar
mm
m/h
C
kJ/kW
kJ/kW
kW
kW
kW
kW
mm
mm
bar

25/3.4 30/4.2 30/3.4 35/4.2 35/3.4 40/4.2


30/4.0
40/4.0
45/4.0
50
65
65
40/3.2 45/4.0 40/3.2 45/4.0 40/3.2 45/4.0
38
38
38
550
500
142
156
406

158
174
464

189
208
613

550
500
211
232
648

213
234
690

238
261
728

52

69

78

400/400
400
0.03

500/500
500
0.03

500/500
500
0.03

340

kg/h

7,580

362

kg/h

7,150

bar
bar
Nm
mmWs/
mm

550
500

345

290

330

300

337

8,395 11,420 11,723 10,395 13,180


366

309

350

320

357

7,920 10,775 11,060 12,120 12,435


30
7
0.5

30
7
0.5

30
7
0.5

25/50

25/50

25/50

Reference conditions: LCV = 42,700 kJ/kg, ambient temperature 25 C


charge air coolant temperature 25 C, tolerance 5 %, + 1 % for engine driven pump
Standard value, tolerance 0.3 g/kWh, related on full load
Charge air heat based on 45 C ambient temperature
Preheated engine
Tolerance 10 %, rel. humidity 60 %
MARPOL 73/78 Annex VI, Cycle E2, E3, D2
M 20 C Generator Set - 08.2012

2.

General data and operation of the engine

2.2

Engine dimensions

2.2.1 Turbocharger at free end

Engine
Type
6 M 20 C
8 M 20 C
9 M 20 C

Dry
weight *

Dimensions [mm]
L1
6,073
6,798
7,125

L2
5,727
6,475
6,802

H1
2,164
2,335
2,335

H2
1,054
1,054
1,054

W1
1,680
1,816
1,816

W2
627
710
710

[t]
18.8
23.1
26.0

* depending on generator weight


Prime mover and generator are always exibly coupled.

Removal of:
Piston

in transverse direction
in longitudinal direction

X1 = 2,960 mm
X2 = 3,280 mm

Cylinder liner

in transverse direction
in longitudinal direction

Y1 = 2,965 mm
Y2 = 3,140 mm

Reduced removal height with special tools only.


Min. centre distance of 2 gensets:

2,010 mm

Note: The required centre distance can be increased by generator dimensions.


M 20 C Generator Set - 08.2012

2.

General data and operation of the engine

2.3

Restrictions for low load operation and stand-by mode

The engine can be started, stopped and run on heavy fuel oil under all operating conditions.
The HFO system of the engine remains in operation and keeps the HFO at injection viscosity. The
temperature of the engine injection system is maintained by circulating hot HFO and heat losses are
compensated (stand-by mode).
The lube oil treatment system (lube oil separator) remains in operation, the lube oil is separated
continuously (stand-by mode).
The operating temperature of the engine cooling water is maintained by the cooling water preheater
(stand-by mode).
Below 25 % output heavy fuel operation is neither efcient nor economical.
A change-over to diesel oil is recommended to avoid disadvantages as e.g. increased wear and tear,
contamination of the air and exhaust gas systems and increased contamination of lube oil.

Cleaning run of engine


3h

1h

30 min

15 min

PE %
100
Cleaning run after partial load operation
70
Load increase period
approx. 15 min.

50
40
30
20
HFO operation
15
10
8

Restricted HFO operation

6
1h

5 6

8 10

15 20 24 h

Emergency start in the event of black out


Emergency start with gravity feed fuel from the diesel oil day tank is possible.
The bottom edge of the diesel oil tank has to be arranged approx. 4 m above injection pump level.
M 20 C Generator Set - 08.2012
8

2.

General data and operation of the engine

2.4

Load application and recovery behaviour

The permissible load increase according to ISO 8528-5 and IACS must be carried out in several steps,
depending on the mean effective pressure. The ships network must be designed so that this permissible
load increase is kept. The shipyard has to provide the approval of the responsible classication society
in time before classication of the engine.
Guide values for maximum possible sudden power increases as a function of brake mean effective
pressure, pme at declared power.

M 20 C in-line engines
To achieve recovery behaviour according to class requirements
[%]

4. load step

Load increase referred to continuos rating

100
90

80
3. load step

Limiting curve for


3rd load step

70
60
2. load step

Limiting curve for


2nd load step

50

40
Limiting curve for
1st load step

1. load step
30

20
10

10

12

14

16

18

20

22

24

26

28

BMEP at cont. rating of diesel engine


[bar]

Example:

6 M 20 C, 1,140 kW, 1,000 rpm, bmep = 24.2 bar


Curves are provided as typical examples.

1. max. load from 0 % to 33 % output


2. max. load from 34 % to 55 % output
3. max. load from 56 % to 75 % output
4. max. load from 76 % to 100 % output
M 20 C Generator Set - 08.2012

2.

General data and operation of the engine

2.4

Load application and recovery behaviour

Recovery behaviour after a sudden load increase according to load steps depending on pme / unloading
corresponding ISO 8528-5.

10

M 20 C Generator Set - 08.2012

2.

General data and operation of the engine

2.4.1 Standard loading up procedure


Our standard loading procedure for M 20 C in-line engines to achieve recovery behaviour in
accordance with class requirements.

Load

100 %

75 %

55 %

33 %

5-10s 5-10s 5-10s 5-10s

Time

M 20 C Generator Set - 08.2012

11

2.

General data and operation of the engine

2.4.2 Speed control of auxiliary generating sets / DE - drive


Electronic governor system maker Regulateurs Europa (RE)
Type:

Actuator
Governor

2221
Viking 35

Optional Woodward: Actuator UG48


Governor 723+

The engine is equipped with an actuator without mech. back-up governor (optional with back-up). The
electronic governor is delivered as a separate part for installation by the shipyard at a suitable place
(e.g. switchboard).
On request the governor can be installed inside a separate cabinet.
The governor comprises the following functions:

Speed setting range to be entered via parameters


Adjustable acceleration and declaration times
Adjustable synchronizing ramp rates
Starting fuel limiter
Input for stop (not emergency stop)
18 - 32 V DC voltage supply
Alarm output
Isochronous load sharing by master / slave principle
Droop operation selectable

2.4.3 Speed control of auxiliary generating sets


Mechanical governor (optional electronic governor)
Standard settings:
Droop 4 %
Fuel rack 110 %
Speed setting range + 5 %
Standard speed governor, maker RE, type 1102, equipped with:
Speed setting motor (24 V DC/100 % continuous duty) for a setting speed of 4 - 8 sec/Hz
Start fuel limiter
Shut-down solenoid (24 V DC/100 % continuous duty) for remote stop (not for automatic engine stop)
Innitely adjustable from the outside at the governor, 0 - 10 % droop

12

M 20 C Generator Set - 08.2012

3.

Systems

3.1

Combustion air system

3.1.1 General
To obtain good working conditions in the engine room and to ensure trouble-free operation of all
equipment attention shall be paid to the engine room ventilation and the supply of combustion air.
The combustion air required and the heat radiation of all consumers/heat producers must be taken
into account.

3.1.2 Air intake from engine room (standard)

Fans are to be designed for a slight overpressure in the engine room (except cruise vessels).
On system side the penetration of water, sand, dust, and exhaust gas must be prevented.
The air ow must be conveyed directly to the turbocharger.
The temperature at turbocharger lter should not fall below + 10 C.
In cold areas warming up of the air in the engine room must be ensured.

3.1.3 Air intake from outside


The intake air duct is to be provided with a lter. Penetration of water, sand, dust, and exhaust gas
must be prevented.
Connection to the turbocharger is to be established via an expansion joint. For this purpose the
turbocharger will be equipped with a connection socket.
At temperatures below + 10 C the Caterpillar/Application Engineering must be consulted.

3.1.4 Radiated heat


See technical data
To dissipate the radiated heat a slight and evenly distributed air ow is to be conveyed along the
engine exhaust gas manifold starting from the turbocharger.

M 20 C Generator Set - 08.2012

13

3.

Systems

3.2

Starting air system

As required by the classication societies, at minimum two air compressors are required. The nominal
starting air gauge pressure for all MaK engines is 30 bar. The starting air must have a dened quality,
be free from solid particles, oil, and water.

3.2.1 Starting air quality requirements


For proper operation of the engine a starting air quality of class 4 according ISO 8573-1 is required.

Class

1
2
3
4
5
6

Particle size

Particle density

max. in m
0.1
1
5
15
40

max. in mg/m
0.1
1
5
8
10

Water
pressure dew
point in C
-70
-40
-20
3
7
10

Water
mg/m
3
120
880
6,000
7,800
9,400

Oil
Residual oil
content in mg/m
0.01
0.1
1
5
25

The standard DIN ISO 8573-1 denes the quality classes of compressed air as follows:
Oil content
Specication of the residual quantity of aerosols and hydrocarbons which may be contained in the
compressed air.
Particle size and density
Specication of size and concentration of particles which may still be contained in the compressed air.
Pressure dew point
Specication of the temperature to which compressed air may be cooled down without condensation
of the contained vapor. The pressure dew point changes with the air pressure.

14

M 20 C Generator Set - 08.2012

3.

Systems

3.2.2 System diagram

General notes:
For location, dimensions, and design (e.g. exible
connection) of the disconnecting points see engine
installation drawing.
Clean and dry starting air is required.
Notes:
a Control air
d Water drain (to be mounted at the lowest point)
e To other gensets
h Please refer to the measuring point list regarding
design of the monitoring devices.
j Automatic drain valve required
Connecting points:
C86 Connection, starting air
M 20 C Generator Set - 08.2012

Accessories and ttings:


AC1 Compressor
AC2 Stand-by compressor
AM1 Air starter
AR1 Starting valve
AR4 Pressure reducing valve
AR5 Oil and water separator
AT1
Starting air receiver
AT2
Starting air receiver
PI
Pressure indicator
PSL Pressure switch low, only for main
engine
PT
Pressure transmitter
AT1 / AT2 Option:
Typhon valve
Relief valve with pipe connection
15

3.

Systems

3.2.3 Starting air system components


a)

Receiver capacity acc. to GL recommendation AT1/AT2


Number
of gensets
1
2

Number
of receivers
2
2

Receiver capacity
available [l]
125
250

L
mm
1,978
1,868

D
mm
323.9
480

Valve head
DN 40
DN 40

Weight
approx. kg
150
230

1 Starting valve DN 38
2 Filling valve DN 18
3 Inlet lling valve
4 Safety valve G1/2
5 Free connection G1/2
6 Drainage horizontal
7 Drainage vertical
9 Connection G1/2 for vent
10 Outlet starting-air valve
12 Pressure gauge
Option:
8 Typhon valve DN 16
11 Outlet typhon valve

If a CO2 re extinguishing system is installed in the engine room, the blow-off connection of the safety
valve is to be piped to the outside.

Requirement of classication societies (regarding design)


No. of starts:
No. of receivers:

16

6
min. 2

M 20 C Generator Set - 08.2012

3.

Systems

b) Compressor AC1/AC2:

2 compressors with a total output of 50 % each are required.


The lling time from 0 to 30 bar must not exceed 1 hour.
Capacity
V [m/h] = VRec. 30
VRec. - Total receiver volume [m]

c) Air starter (tted) AM1:

3.3

With pressure reducer 30/10 bar. Min. starting air pressure


and air consumption see technical data.

Exhaust system

The exhaust system carries the engines exhaust gases out of the engine room, through piping, to the
atmosphere. A good exhaust system will have a minimum back pressure. Exhaust back pressure is
generally detrimental, as it tends to reduce the air ow through the engine. Indirectly, exhaust back
pressure tends to raise exhaust temperature which will reduce exhaust valve and turbocharger life.

3.3.1 General
Position of exhaust gas nozzle:

A nozzle position of 0, 30, 45, 60 and 90 from the vertical


is possible.
The basic position is 45. The other positions are reached by
using a transition piece.

Design of the pipe cross-section:

The pressure loss is to be minimized in order to optimize fuel


consumption and thermal load of the engine.
Max. ow velocity: 40 m/s (guide value).
Max. pressure loss (incl. silencer and exhaust gas boiler):
30 mbar
(lower values will reduce thermal load of the engine).
Each engine needs an independent exhaust gas routing.

3.3.2 Exhaust expansion joint


6 M 20 C
8/9 M 20 C
M 20 C Generator Set - 08.2012

Diameter DN
400
500

Length [mm]
365
360
17

3.

Systems

3.3.3 Silencer
Design according to the absorbtion principle with wide-band attenuation over great frequency range
and low pressure loss due to straight direction of ow. Sound absorbing lling consisting of resistant
mineral wool.
Sound level reduction 35 dB(A) (standard). Max. permissible ow velocity 40 m/s.

Silencer with spark arrester:

Soot separation by means of a swirl device (particles are spun


towards the outside and separated in the collecting chamber).
Sound level reduction 35 dB(A). Max. permissible ow velocity
40 m/s.
Silencers are to be insulated by the yard. Foundation brackets
are to be provided as an option.

18

M 20 C Generator Set - 08.2012

3.

Systems

Dimension of silencer/spark arrestor and silencer


(in case of Caterpillar supply):

Installation: vertical/horizontal
Flange according to DIN 86044
Counteranges, screws and gaskets are
included, without supports and insulation

Silencer

Spark arrestor and silencer

6 M 20 C
8/9 M 20 C

DN
400
500

Attenuation 35 dB (A)
D
B
L
838
538
3,686
938
588
3,936

kg
680
800

3.3.4 Exhaust gas boiler (if needed)


Each engine should have a separate exhaust gas boiler. Alternatively, a common boiler with separate
gas sections for each engine is acceptable.
Particularly if exhaust gas boilers are installed attention must be paid to the maximum recommended
back pressure.
M 20 C Generator Set - 08.2012
19

3.

Systems

3.3.5 Turbocharger cleaning device


Cleaning the turbocharger compressor:

The components for cleaning (dosing vessel, pipes, shutoff valve) are installed on the engine.
Water is fed before compressor wheel via injection pipes
during full load operation every 24 hours.

Cleaning the turbine blade and


nozzle ring:

The cleaning is carried out with clean fresh water wet


cleaning during low load operation at regular intervals
of 150 hours, depending on the fuel quality.
Cleaning in 3 - 4 intervals of 30 seconds each.
Fresh water of 2 - 2.5 bar is required.

Cleaning intervals
3 - 4 times

C42

20

Injection time
[sec]
30

Fresh water supply, DN 12

M 20 C Generator Set - 08.2012

3.

Systems

3.4

Cooling water system

MaK engines generally use two closed water cooling circuits. The High Temperature (HT) cooling
water circuit is used to cool the engine. The Low Temperature (LT) cooling water circuit cools the
charge air and the lube oil. Moreover, the LT cooling water circuit can be used to cool additional
equipment, e.g. a generator.
The cooling water needs to be treated according to Caterpillar requirements for MaK engines.

3.4.1 Cooling water quality requirements


The engine cooling water is a medium, that must be carefully selected, treated and controlled. In
case of using untreated cooling water corrosion, erosion and cavitation may occur on the walls of the
cooling system.
Deposits may impair the heat transfer and result in thermal overload of the components to be cooled.
The treatment with an anti-corrosion additive has to be effected before the rst commissioning of the
plant.
Requirements
The characteristics of the untreated cooling water must be within the following limits:

distillate or freshwater free from foreign matter (no sea water or waste water)
a total hardness of max. 10 dH
pH-value 6.8 - 8
chloride ion content of max. 50 mg/l

Supplementary information
Distillate: If distilled or fully desalinated water is available, this should preferably be used as engine
cooling water.
Hardness: Water with more than 10 dGH (German total hardness) must be mixed with distillate or be
softened.
Treatment before operating the engine for the rst time
Treatment with anti-corrosion additive should be done prior to the rst operation of the engine to
prevent irreparable initial damage.

It is not allowed to run the engine without cooling water treatment!


M 20 C Generator Set - 08.2012

21

3.

Systems

FW-COOLER HT

3.4.2 System diagram Heat balances


90C
6 M 20 C
V = 25 cbm/h
V = 40 cbm/h

49,8C

84,6C

CHARGE AIR COOLER


Q = 414 kW
v = 40 cbm/h

P = 1020 kW
n = 900 1/min
Q = 156 kW

41,1C

84,6C

41,4C

FW-COOLER LT

ENGINE
6 M20C IMOII

Q = 548 kW

90C

Q = 156 kW

44,1C

LUB. OIL COOLER


Q = 156 kW
v = 40 cbm/h

FW PUMP HT

FW PUMP LT

V = 25 cbm/h
p = 3,2 bar

V = 40 cbm/h
p = 2,7 bar

SW PUMP
V = 50 cbm/h
p = 2,5 bar

38C

32C
V = 40 cbm/h

SEA CHEST

44,4C

FW-COOLER HT

V = 30 cbm/h

V = 45 cbm/h

49,9C

P = 1140 kW
n = 1000 1/min
Q = 174 kW

85C

CHARGE AIR COOLER


Q = 464 kW
v = 45 cbm/h
41C

85C

41,7C

FW-COOLER LT

ENGINE
6 M20C IMOII

Q = 622 kW

90C

Q = 174 kW

90C

LUB. OIL COOLER


Q = 158 kW
v = 45 cbm/h

FW PUMP HT

FW PUMP LT

V = 30 cbm/h
p = 3,9 bar

V = 45 cbm/h
p = 3,2 bar

SW PUMP
38C

V = 55 cbm/h
p = 2,5 bar
32C

V = 45 cbm/h

SEA CHEST

22

M 20 C Generator Set - 08.2012

3.

Systems
44,4C

FW-COOLER HT

V = 30 cbm/h

V = 45 cbm/h

53,3C

84,6C

CHARGE AIR COOLER


Q = 613 kW
v = 45 cbm/h

P = 1360 kW
n = 900 1/min
Q = 208 kW

41,6C

84,0C

41,8C

FW-COOLER LT

ENGINE
8 M20C IMOII

Q = 802 kW

90C

Q = 208 kW

90C

8 M 20 C

LUB. OIL COOLER


Q = 189 kW
v = 45 cbm/h

FW PUMP HT

FW PUMP LT

V = 30 cbm/h
p = 3,1 bar

V = 45 cbm/h
p = 2,4 bar

SW PUMP
V = 70 cbm/h
p = 2,5 bar

38C

32C
V = 45 cbm/h

SEA CHEST

43,7C

FW-COOLER HT

V = 35 cbm/h

V = 45 cbm/h

54,4C

P = 1520 kW
n = 1000 1/min
Q = 232 kW

84,3C

CHARGE AIR COOLER


Q = 648 kW
v = 45 cbm/h
42,0C

84,3C

41,2C

FW-COOLER LT

ENGINE
8 M20C IMOII

Q = 859 kW

90C

Q = 232 kW

90C

LUB. OIL COOLER


Q = 211 kW
v = 45 cbm/h

FW PUMP HT

FW PUMP LT

V = 35 cbm/h
p = 3,7 bar

V = 45 cbm/h
p = 3,2 bar

SW PUMP
38C

V = 80 cbm/h
p = 2,5 bar
32C

V = 45 cbm/h

SEA CHEST

M 20 C Generator Set - 08.2012

23

3.

Systems
44,2C

FW-COOLER HT

V = 35 cbm/h

V = 45 cbm/h

55,3C

84,8C

CHARGE AIR COOLER


Q = 690 kW
v = 45 cbm/h

P = 1530 kW
n = 900 1/min
Q = 234 kW

42,1C

84,3C

41,7C

FW-COOLER LT

ENGINE
9 M20C IMOII

Q = 903 kW

90C

Q = 234 kW

90C

9 M 20 C

LUB. OIL COOLER


Q = 213 kW
v = 45 cbm/h

FW PUMP HT

FW PUMP LT

V = 35 cbm/h
p = 2,9 bar

V = 45 cbm/h
p = 2,4 bar

SW PUMP
V = 80 cbm/h
p = 2,5 bar

38C

32C
V = 45 cbm/h

SEA CHEST

45,2C

FW-COOLER HT

V = 40 cbm/h

V = 45 cbm/h

56,5C

P = 1710 kW
n = 1000 1/min
Q = 261 kW

84,4C

84,9C

CHARGE AIR COOLER

42,4C

FW-COOLER LT

ENGINE
9 M20C IMOII

Q = 728 kW
v = 45 cbm/h
42,6C

Q = 966 kW

90C

Q = 261 kW

90C

LUB. OIL COOLER


Q = 238 kW
v = 45 cbm/h

FW PUMP HT

FW PUMP LT

V = 40 cbm/h
p = 3,5 bar

V = 45 cbm/h
p = 3,2 bar

SW PUMP
38C

V = 80 cbm/h
p = 2,5 bar
32C

V = 45 cbm/h

SEA CHEST

24

M 20 C Generator Set - 08.2012

3.

Systems

3.4.3 System diagram Cooling water system

General notes:
For location, dimensions and design (e.g. exible connection) of the connecting points see engine installation drawing.
With skin cooler not required:

Seawater system (SP1, SP2, SF1, ST1)

Temp. control valve FR3 required, if heat recovery is installed.


Accessories and ttings:
Connecting points:
CH1 Charge air cooler
LH1 Lube oil cooler
C15 Charge air cooler LT, outlet
CR1 Charge air temperature control valve
SF1 Seawater lter
C21 Freshwater pump HT, inlet
CR3 Sensor for charge air temp. control valve
SP1 Seawater pump
C22 Freshwater pump LT, inlet
DH3 Diesel oil cooler
SP2 Seawater stand-by pump
C25 Cooling water, engine outlet
FH1 Freshwater cooler HT
ST1 Sea chest
C37 vent connection
FH2 Freshwater cooler LT
FH3 Heat consumer
LI
Level indicator
Notes:
FH5 Freshwater preheater
LSL Level switch low
e Bypass DN 12
FP1 Freshwater pump (tted on engine) HT
PI
Pressure indicator
f Drain
FP2 Freshwater pump (tted on engine) LT
PSL Pressure switch low
h Please refer to the measuring
FP7 Preheating pump
PSLL Pressure switch low low
point list regarding design of the
FR1 Temperature control valve HT
PT Pressure transmitter
monitoring devices
FR2 Temperature control valve LT
TI
Temperature indicator
FR3 Flow temperature control valve HT
TSHH Temperature switch high
FT1 Compensation tank HT
TT Temperature transmitter (PT 100)
FT2 Compensator tank LT
M 20 C Generator Set - 08.2012

25

3.

Systems

3.4.4 Cooling water system components


The heat generated by the engine (cylinder, charge air and lube oil) is to be dissipated by treated
freshwater acc. to the Caterpillar coolant regulations.
The system components of the LT cooling water circuit are designed for a max. LT cooling water
temperature of 38 C with a corresponding seawater temperature of 32 C in tropical conditions.
Two-circuit cooling:

with two-stage charge air cooler.

a) LT cooling water pump (tted on engine) FP2: Option: separate (FP4)


Capacity: acc. to heat balance
b) LT cooling water stand-by pump (optional) FP6: Capacity: acc. to heat balance
c) HT cooling water pump (tted) FP1:

Option: separate (FP3)


Capacity: acc. to heat balance

d) HT cooling water stand-by pump (optional) FP5: Capacity: acc. to heat balance
e) HT temperature controller (separate) FR1:

P-controller with manual emergency adjustment


(basis). Option: PI-controller with electric drive
(sep. only)
H

30

6/8/9 M 20 C
6/8/9 M 20 C

HT
LT

DN
65
80*

Dimensions [mm]
D
F
G
185
165
154
200
171
267

H
158
151

Weight
[kg]
26
27
*

26

Minimum, depending on total


cooling water ow

M 20 C Generator Set - 08.2012

3.

Systems

f) LT temperature controller (separate) FR2:

g) HT ow temperature controller (separate,


option: in case of HT heat recovery) FR3:

h) Pre-heater (tted) FH5/FP7:

P-controller with manual emergency adjustment.


Option: PI-controller with electric drive.

P-controller with manual emergency adjustment.


Option: PI-controller with electric drive.

Consisting of circulating pump 1), electric preheater 2)


and control cabinet (separate).
1)
2)

Capacity
Output

3.5 m/h
7.5 kW

i) HT cooler (separate) FH1:

Plate type, size depending on the total heat to be


dissipated.

j) LT cooler (separate) FH2:

Plate type (plates made of titanium), size depending


on the total heat to be dissipated.

k) Header tank FT2:

Arrangement: min. 4 m / max. 16 m above crankshaft centre line (CL).


Size acc. to technical engine data.
All continuous vents from engine are to be
connected.

M 20 C Generator Set - 08.2012

27

3.

Systems

3.4.5 Recommendation for cooling water system


Drain tank with lling pump:

It is recommended to collect the treated water during


maintenance work (to be installed by the yard).

Option for fresh and seawater, vertical design.


Rough calculation of power demand for the electric
balance.

Electric motor driven pumps:

HV
P=

[kW]
367

P PM V H -

28

Power [kW]
Power of electr. motor [kW]
Flow rate [m/h]
Delivery head [m]
Density [kg/dm]
Pump efciency
0.70 for centrifugal pumps

PM = 1.5 P
PM = 1.25 P
PM = 1.2 P
PM = 1.15 P
PM = 1.1 P

< 1.5
kW
1.5 - 4 kW
4 - 7.5 kW
> 7.5 - 40 kW
> 40
kW

M 20 C Generator Set - 08.2012

3.

Systems

3.5

Fuel oil system, MGO/MDO operation

MaK diesel engines are designed to burn a wide variety of fuels. See the information on fuel requirements in section MDO / MGO and heavy fuel operation or consult the MaK technical product support.
For proper operation of MaK engines the minimum MaK requirements for storage, treatment and
supply systems have to be observed; as shown in the following sections.

3.5.1 Quality requirements for MGO/MDO fuel/permitted fuels


Two fuel product groups are permitted for MaK engines:

MGO
Designation

MDO

ISO 8217:2010

ISO-F-DMA

Max. viscosity
[cSt/40 C]
2.0 - 6.0

ASTM D 975-78

No. 1 D
No. 2 D
DIN EN 590

2.4
4.1
8

DIN

Designation
ISO-F-DMB
ISO-F-DMZ
No. 2 D
No. 4 D

Max. viscosity
[cSt/40 C]
11
6
4.1
24.0

Min. injection viscosity 1.5 mm/s (cSt)


Max. injection viscosity 12 mm/s (cSt)

M 20 C Generator Set - 08.2012

29

3.

Systems

3.5.2 System diagram - Fuel oil system, MGO operation

General notes:
For location, dimensions and design (e.g. exible connection) of the connecting points see engine installation drawing.

Notes:
a Day tank level above engine
d Take care for feeding height
p Free outlet required
s Please refer to the measuring point list regarding design of the monitoring devices
Accessories and ttings:
DF1 Fuel ne lter (duplex lter)
DF2 Fuel primary lter (duplex lter)
DF3 Fuel coarse lter
DH3 Diesel oil cooler
DP1 Diesel oil feed pump
DP3 Diesel oil transfer pump (to day tank)
DR2 Fuel pressure regulating valve
DT1 Diesel oil day tank
DT4 Diesel oil storage tank
KP1 Fuel injection pump
KT1 Drip fuel tank

30

FQI Flow quantity indicator


LI
Level indicator
LSH Level switch high
LSL Level switch low
PDI Diff. pressure indicator
PDSH Diff. pressure switch high
PI
Pressure indicator
PSL Pressure switch low
TI
Temperaute indicator

Connecting points:
C71 Fuel inlet engine tted transfer pump
C72 Fuel outlet engine tted transfer pump
C73 Fuel inlet, to engine-tted pump
C75 Connection, stand-by pump
C78 Fuel outlet
C80 Drip fuel connection
C81 Drip fuel connection
C81b Drip fuel connection (lter pan)

M 20 C Generator Set - 08.2012

3.

Systems

3.5.3 System diagram Fuel oil system, MDO operation

General notes:
For location, dimensions and design (e.g. exible connection) of the connecting points see engine installation drawing.
Notes:
d Take care for feeding height
p Free outlet required
s Please refer to the measuring point list regarding design of the monitoring devices
Accessories and ttings:
DF1 Fuel ne lter (duplex lter)
DF2 Fuel primary lter (duplex lter)
DF3 Fuel coarse lter
DH1 Diesel oil preheater
DH2 Electrical preheater (separator)
DH3 Diesel oil cooler
DP1 Diesel oil feed pump
DP2 Diesel oil stand-by feed pump
DP3 Diesel oil transfer pump (to day tank)
DP5 Diesel oil transfer pump (separator)
DR2 Fuel pressure regulating valve
DS1 Separator
DT1 Diesel oil day tank
DT4 Diesel oil storage tank
KP1 Fuel injection pump
KT1 Drip fuel tank
M 20 C Generator Set - 08.2012

FQI Flow quantity indicator


LI
Level indicator
LSH Level switch high
LSL Level switch low
PDI Diff. pressure indicator
PDSH Diff. pressure switch high
PI
Pressure indicator
PSL Pressure switch low
TI
Temperaute indicator
TSL Temperature switch low

Connecting points:
C73 Fuel inlet
C75 Connection, stand-by pump
C78 Fuel outlet
C80 Drip fuel connection
C81 Drip fuel connection
C81b Drip fuel connection (lter pan)

31

3.

Systems

3.5.4 MGO/MDO fuel system components


a) Fine lter (tted) DF1:

Duplex lter, mesh size see technical data.

b) Strainer (separate) DF2:

Mesh size 0.32 mm, dimensions see HFO-system.

c) Pre-heater (separate) DH1:

Heating capacity
Peng. [kW]
Q [kW] =
166
Not required:
MGO 7 cSt/40C
Heated day tank

d) MGO/MDO cooler DH3:

Required to prevent overheating of the day tank.

e) Feed pump (tted) DP1:

Capacity see technical data.

f) Feed pump (separate) DP1:

Capacity see technical data.

32

M 20 C Generator Set - 08.2012

3.

Systems

g) MGO/MDO service tank DT1:

The classication societies require the installation


of at least two service tanks. The minimum volume
of each tank should, in addition to the MDO/MGO
consumption of the generating sets, enable an eight
hours full load operation of the main engine.
Cleaning the MDO/MGO by an additional separator
should, rst of all, be designed to meet the
requirements of the diesel generator sets on board.
The tank should be provided with a sludge
compartment including a sludge drain valve and an
overow pipe from the MDO/MGO service tank.

h) Separator DS1:

Recommended for MGO


Required for MDO
The utilisation must be in accordance with the
makers ofcial recommendation (details from the
head ofce).
Veff [l/h] = 0.28 Peng. [kW]

M 20 C Generator Set - 08.2012

33

34

1)

1)

Density at 15C

Kin. viscosity at
100C

%
(m/m)

%
(m/m)

% (V/V)

%
(m/m)

mg/kg

mg/kg

mg/kg

mg/kg

mg/kg

Ash

Total sedim, after


ageing

Water

Sulphur

Vanadium

Aluminium + Silicon

Zinc

Phosphor

Calcium

max

max

max

max

max

max

25

50

0.3

12 6)

Fuel shall be free of used lubricating oil (ulo)

Kinematic viscosity at 100 C mm/s (cSt)


Kinematic viscosity at 50 C mm/s (cSt)
Kinematic viscosity at 100 F Redw. I sec.

0
6

30

15

15

3.5

0.10

0.10

60

10

975 3)

7
30
200

40

150

0.5

CIMAC
D15

CIMAC
E25

CIMAC
F25

CIMAC
G35

CIMAC
H35

CIMAC
K35

14

24

10
40
300

30

15

15

40

150

3.5

0.5

0.10

0.10

14

30

60

15

980 4)

15
80
600

200

0.10

15

15

5)

25
180
1500

30

15

15

60

3.5

0.5

0.10

30

60

25

991

350

0.15

20

35
380
3000

0.15

18

45
500
5000

350

991

30

15

15

60

3.5

0.5

0.10

30

60

35

55
700
7000

0.15

22

450

1,010

RMB30 RMD80 RME180 RMF180 RMG380 RMH380 RMK380

CIMAC
C10

CIMAC
K45

991

6)

5)

4)

3)

2)

CIMAC
K55

991

30

15

15

60

450

3.5

0.5

0.10

0.15

22

30

60

55

1,010

RMH700 RMK700

CIMAC
H55

ISO: 920
ISO: 960
ISO: 975
ISO: not limited
ISO: Carbon Residue 2.5/10

30

15

15

60

450

3.5

0.5

0.10

0.15

22

30

60

45

1,010

RMH500 RMK500

CIMAC
H45

Fuel oil system, HFO operation

max

5)

960 2)

RMB30

CIMAC
B10

3.6

max

max

max

max

min

min

max

max

Limit

RMA10

CIMAC
A10

Systems

An indication of the approximate equivalents in


kinematic viscosity at 50 C and Redw. I sec.
100 F is given below:

%
(m/m)

Pour point (winter)


(summer)

Carbon Residue
(Conradson)

Flash point

cSt

Dim.

kg/m

Characteristic

Related to
ISO8217 (2010):E-

Designation

3.

3.6.1 Requirements for residual fuels for diesel engines (as bunkered)

M 20 C Generator Set - 08.2012

3.

Systems

3.6.2 Viscosity/temperature diagram

M 20 C Generator Set - 08.2012

35

3.

Systems

3.6.3 System diagram Heavy fuel oil operation


C76 , C78
Peak pressure max. 16 bar

General notes:
For location, dimensions and design (e.g. exible connection) of the connecting points see engine installation drawing.
No valve ttings with loose cone must be installed by the shipyard in the admission and return lines.
Accessories and ttings:
Notes:
Heavy fuel day tank
DH3
Fuel oil cooler from MDO operation HT1
ff Flow velocity in circuit system 0.5 m/
HT2
Mixing tank
DT1
Diesel oil day tank
s
HT5/HT6 Settling tank
HF1
Fuel ne lter (duplex lter)
p Free outlet required
KP1
Fuel injection pump
HF2
Fuel primary lter
s Please refer to the measuring point
KT2
Sludge tank
HF3
Fuel coarse lter
list regarding design of the monitoring
FQI
Flow quantity indicator
HF4
Self cleaning fuel lter
devices
LI
Level indicator
HH1
Heavy fuel nal preheater
u From diesel oil separator or diesel oil
LSH
Level switch high
HH2
Stand-by nal preheater
transfer pump
LSL
Level switch low
HH3
Heavy fuel preheater
All heavy fuel oil pipes must be insulated.
PDI
Diff. pressure indicator
HH4
Heating coil
---- heated pipe
PDSH
Diff. pressure switch high
HP1
Fuel pressure pump
PDSL
Diff. pressure switch low
HP2
Fuel stand-by pressure pump
Connecting points:
PI
Pressure indicator
HP3
Fuel circulating pump
C76
Inlet duplex lter
PT
Pressure transmitter
HP4
Fuel stand-by circulating pump
C78
Fuel outlet
Temperature indicator
HP5
Heavy fuel transfer pump (separator) TI
Drip fuel
Temperature transmitter (PT 100) C81
HP6
Stand-by transfer pump (separator) TT
C81b Drip fuel (lter pan)
VI
Viscosity indicator
HR1
Fuel pressure regulating valve
VSH
Viscosity control switch high
HR2
Viscosimeter
VSL
Viscosity control switch low
HS1/HS2 Heavy fuel separator

36

M 20 C Generator Set - 08.2012

3.

Systems

3.6.4 HFO system components


Supply system:

A closed pressurized system between day tank and


engine is required as well as the installation of an
automatic backflushing filter with a mesh size of
10 m (absolute).

a) Fine lter (tted) HF1:

Mesh size 34 m
Differential pressure indication and alarm contact
tted

b) Strainer HF2:

Mesh size 0.32 mm

M 20 C Generator Set - 08.2012

Output
[kW]

DN

5,000
10,000
20,000
> 20,000

32
40
65
80

H1

H2

206
250
260
370

180
210
355
430

[mm]
249
330
523
690

220
300
480
700

37

3.

Systems

c) Self cleaning lter HF4:

Mesh size 10 m (absolute)

8,000 kW, DN 50

> 8,000 kW, DN 100

Dismantling of lter
element
300 mm

Dismantling of lter
element
300 mm

d) Viscosimeter HR2:

This device regulates automatically the heating of


the nal-preheater depending on the viscosity of
the bunkered fuel oil, so that the fuel will reach the
nozzles with the viscosity required for injection.

e) Pressure pumps HP1/HP2:

Screw type pump with mechanical seal.


Installation vertical or horizontal. Delivery head 5 bar.
Peng. [kW]
Capacity
V [m/h] = 0.4
1,000

f) Circulating pumps HP3/HP4:

Screw type pump with mechanical seal.


Installation vertical or horizontal. Delivery head 5 bar.
Peng. [kW]
Capacity

V [m/h] = 0.7
1,000

38

M 20 C Generator Set - 08.2012

3.

Systems

g) Pressure regulating valve HR1:

Controls the pressure at the engine inlet, approx. 4 bar.

Engine outputs

3,000 kW

> 3,000 kW

h) Final preheater HH1/HH2:

Heating media:
Electric current (max. surface power density 1.1 W/cm)
Steam
Thermal oil
Temperature at engine inlet max. 150 C.
Vent

i) Mixing tank HT2:

Engine output

Volume

[kW]

[l]

[kg]

4,000

50

950

323

750

70

10,000

100

1,700

323

1,500

120

> 10,000

200

1,700

406

1,500

175

M 20 C Generator Set - 08.2012

Dimensions [mm]

Weight

Inlet
from
pressure
pump
Outlet to
engine

39

3.

Systems

j) Bunker tanks:

In order to avoid severe operational problems due


to incompatibility, each bunkering must be made in
a separate storage tank.

k) Settling tanks HT5/HT6:

In order to ensure a sufcient effect, the following


settling tank designs are permitted:
2 settling tanks, each with a capacity sufcient
for 24 hours full load operation of all consumers
1 settling tank with a capacity sufcient for 36
hours full load operation of all consumers and
automatic lling
Settling tank temperature 70 - 80 C

l) Day tank DT1/HT1:

Two day tanks are required. The day tank capacity


must cover at least 4 hours/max. 24 hours full load
operation of all consumers. An overow system into
the settling tanks and sufcient insulation are required.

Guide values for temperatures


Fuel viscosity
cSt/50 C
30 - 80
80 - 180
> 180 - 700

m) Separators HS1/HS2:

40

Tank temperature
[C]
70 - 80
80 - 90
max. 98

Caterpillar recommends to install two self-cleaning


separators. Design parameters as per supplier
recommendation. Separating temperature 98 C.
Maker and type are to be advised by Caterpillar.

M 20 C Generator Set - 08.2012

3.

Systems

Symbols
FLOW1

Flowmeter

SP1/SP2 Screw displacement


BP1/BP2 pump

3.6.5 System diagram Standard HFO supply and booster module


Steam heated
Option:

Thermal oil heated


Electric heated

H1/H2

steam heater*

CL1

Cooler

VA1

Viscosimeter

FIL1

Duplex filter

AF1

Automatic filter

T1

Mixing tank

PD1

Metal bellows
accumulator

COV1
COV3

Change over valve

PCV1

Pressure regulating
valve

CV1

Control valve
Y-strainer
Steam trap
Globe valve
Non-return valve
Safety valve, angle
Magnet valve
test valve
Brass pres. gauge
shock absorber
Ball valve locking
device
Ball valve
Butterfly valve
Pipe with insulation
Pipe with insulation &
trace heating
Scope of supply
module

DPA
DPI
DPS
FI
GS
LAL
LS
M
PI
PS
TA
TI
TS
VA
VIC
*
M 20 C Generator Set - 08.2012

Diff. pressure alarm


Diff. pressure indicator
Diff. pressure switch
Flow indicator
Limit switch
Level alarm low
Level switch
Motor drive
Pressure indicator
Pressure switch
Temperature alarm
Temperature indicator
Temperature sensor
Viscosity alarm
Viscosity controller
option: thermal oil heater
or electric heater

41

3.

Systems

3.6.6 Standard heavy fuel oil supply and booster module


Pressurized System, up to IFO 700 for steam and thermal oil heating, up to IFO 180 for elect. heating
Technical specication of the main components:
a) Primary lter FIL1
1 pc. duplex strainer 540 microns
b) Fuel pressure pumps, vertical installationSP1/SP2
2 pcs. screw pumps with mechanical seal
c) Pressure regulating system PCV1
1 pc. pressure regulating valve
d) Self-cleaning ne lter AF1
1 pc. automatic self cleaning ne lter 10 microns absolute (without by-pass lter)
e) Consumption measuring system FLOW1
1 pc. owmeter with local totalizer
f) Mixing tank with accessories T1
1 pc. pressure mixing tank

approx. 99 l volume from 4,001 - 20,000 kW


(with quick-closing valve)

g) Circulating pumps, vertical installation BP1/BP2


2 pcs. screw pumps with mechanical seal
h) Final preheater H1/H2
2 pcs. shell and tube heat exchangers

each 100 % (saturated 7 bar or thermal oil 180 C)


each 100 % electrical

Heating medium control valve CV1


Control cabinet
1 pc. control valve with built-on positioning drive
1 pc. control cabinet for electr. preheater

(steam/thermal oil)
(electrical)

i) Viscosity control system VA1


1 pc. automatic viscosity measure and control system
j) Cooler CL1
1 pc. shell and tube heat exchanger for operating on MGO/MDO
42

M 20 C Generator Set - 08.2012

3.

Systems

Module controlled automatically with alarms and starters


Pressure pump starters with stand-by automatic
Circulating pump starters with stand-by automatic
PI-controller for viscosity controlling
Starter for the viscosimeter
Analog output signal 4 - 20 mA for viscosity
Alarms
Pressure pump stand-by start
Low level in the mixing tank
Circulating pump stand-by start
Self cleaning ne lter clogged
Viscosity alarm high/low
The alarms with potential free contacts
Alarm cabinet with alarms to engine control room and connection possibility for remote start/stop and
indicating lamp of fuel pressure and circulating pumps
Performance and materials:
The whole module is piped and cabled up to the terminal strips in the electric switch boxes which
are installed on the module. All necessary components like valves, pressure switches, thermometers,
gauges etc. are included. The fuel oil pipes are equipped with trace heating (steam, thermal oil or
electrical) where necessary.

Capacity [kW]
< 3,000
< 4,500
< 6,000
< 9,000
< 12,000
< 16,000
< 24,000
< 32,000
M 20 C Generator Set - 08.2012

Type
Steam / Thermal
Electric
Steam / Thermal
Electric
Steam / Thermal
Electric
Steam / Thermal
Electric
Steam / Thermal
Steam / Thermal
Steam / Thermal
Steam / Thermal

Weight [kg]
1,800
1,700
2,600
2,400
3,200
3,000
3,600
3,200
4,000
4,200
5,400
6,000

L x B x H [mm]
2,800 x 1,200 x 2,000
3,000 x 1,200 x 2,100
3,200 x 1,300 x 2,100
3,400 x 1,400 x 2,100
3,600 x 1,400 x 2,100
4,200 x 1,600 x 2,100
5,000 x 1,700 x 2,100
6,000 x 2,000 x 2,100
43

3.

Systems

3.7

Lube oil system

The engine lube oil performs several basic functions:


Transportation of dirt and wear particles to the lters
Cooling of the heat-affected parts, such as piston, cylinder liner, valves or cylinder head
Protection of bearings from shocks of cylinder ring
Lubrication of metal surfaces / reduction of wear and friction
Neutralisation of corrosive combustion products
Corrosion protection of metal surfaces

3.7.1 Quality requirements of lube oil


The viscosity class SAE 40 is required.
Wear and tear and thus the service life of the engine are depending on the lube oil quality. Therefore
high requirements are made for lubricants:
Constant uniform distribution of the additives at all operating conditions. Perfect cleaning (detergent
effect) and dispersing power, prevention of deposits from the combustion process in the engine.
Sufcient alkalinity in order to neutralize acid combustion residues. The TBN (total base number)
must be between 30 and 40 KOH/g at HFO operation. For MDO operation the TBN is 12 - 20 depending
on sulphur content.

44

M 20 C Generator Set - 08.2012

3.

Systems

The following oils have been tested and approved by Caterpillar:


Manufacturer

Diesel oil/marine-diesel
oil operation
AGIP
DIESEL SIGMA S
CLADIUM 120
BP
ENERGOL HPDX 40
ENERGOL DS 3-154
ENERGOL IC-HFX 204
VANELLUS C3
CHEVRON, CALTEX, DELO 1000 MARINE
TEXACO
TARO 12 XD
TARO 16 XD
TARO 20 DP
TARO 20 DPX
CASTROL
MARINE MLC
MHP 154
TLX PLUS 204
CEPSA
KORAL 1540
ESSO
EXXMAR 12 TP
EXXMAR CM+
ESSOLUBE X 301
MOBIL

MOBILGARD 412
MOBILGARD ADL
MOBILGARD M 430
MOBILGARD 1-SHC 1)
DELVAC 1640
SHELL
GADINIA
GADINIA AL
ARGINA S
ARGINA T
TOTAL LUBMARINE RUBIA FP
DISOLA M 4015
AURELIA TI 4030
GULF
LUKOIL
I
II

1)

II
x
x

x
x
x

HFO operation

CLADIUM 300 S
CLADIUM 400 S
ENERGOL IC-HFX 304
ENERGOL IC-HFX 404

x
x
x
x

TARO 30 DP
TARO 40 XL
TARO 40 XLX

x
x
x

TLX PLUS 304


TLX PLUS 404

x
x

EXXMAR 30 TP
EXXMAR 40 TP
EXXMAR 30 TP PLUS
EXXMAR 40 TP PLUS
MOBILGARD M 430
MOBILGARD M 440
MOBILGARD M 50

x
x
x
x
x
x

ARGINA T
ARGINA X

x
x

AURELIA TI 4030
AURELIA TI 4040

x
x

SEA POWER 4030


SEA POWER 4040
NAVIGO TPEO 40/40
NAVIGO TPEO 30/40

x
x
x
x

II

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x

Approved in operation
Permitted for controlled use
When these lube oils are used, Caterpillar must be informed as currently there is insufcient experience available for MaK engines.
Otherwise the warranty is invalid.
Synthetic oil with a high viscosity index (SAE 15 W/40). Only permitted if the oil inlet temperatures can be decreased by 5 - 10 C.

M 20 C Generator Set - 08.2012

45

3.

Systems

3.7.2 System diagram Lube oil system

General notes:
For location, dimensions and design (e.g.
exible connection) of the connecting
points see engine installation drawing.
Notes:
h Please refer to the measuring
point list regarding design of the
monitoring devices
o See crankcase ventilation installation instructions 5.7
Connecting points:
C46a Stand-by force pump, suction
side
C58
Force pump, delivery side
C60
Separator connection, suction
side or drain or lling pipe
C61
Separator connection, delivery
side or from bypass lter
C91
Crankcase ventilation to stack

46

Accessories and ttings:


LF2
Self cleaning lube oil lter
LF4
Suction strainer
LH1
Lube oil cooler
LH2
Lube oil preheater
LP1
Lube oil force pump
LP2
Lube oil stand-by force pump
LP9
Transfer pump (separator)
LR2
Oil pressure regulating valve
LS1
Lube oil separator
LT1
Lube oil sump tank

LI
LSL
LSH
PDI
PDSH
PI
PSL
PSLL
TI
TSH
TSHH

Level indicator
Level switch low
Level switch high
Diff. pressure indicator
Diff. pressure switch high
Pressure indicator
Pressure switch low
Pressure switch low low
Temperature indicator
Temperature switch high
Temperature switch high

M 20 C Generator Set - 08.2012

3.

Systems

3.7.3 Lube oil system components


a) Force pump (tted) LP1:

Gear pump

b) Prelubrication pump (tted) LP5:

Delivery head 5 bar.


For inland waterway vessels and multi engine plants
only.

c) Stand-by force pump (separate) LP2:

Per engine according to classication society


requirement
Screw type/gear type pump

d) Strainer LF4:

Mesh size 2 - 3 mm

e) Self-cleaning lter (tted) LF2:

The self-cleaning lter protects the engine against


solid particles.
Mesh size 30 m (absolute), type 6.48, make Boll &
Kirch.

M 20 C Generator Set - 08.2012

47

3.

Systems

f) Cooler (tted) LH1:

Tube type

g) Temperature controller LR1:

Not required

h) Crankcase ventilation C91:

At engine 2 x DN 50. Approx. 1 m after the connection


point has to be enlarged to DN 65.
It must be equipped with a condensate trap and
continuous drain. It has to be arranged separately
for each genset. Crankcase pressure max. 150 Pa.

i) Separator;
treatment at MGO/MDO operation LS1:

Recommended with the following design:


Separating temperature 85 - 95 C
Quantity to be cleaned three times/day
Self-cleaning type
Veff [l/h] = 0.18 Peng [kW]

j) Separator;
treatment at HFO operation LS1:

Required with the following design:


Separating temperature 95 C
Quantity to be cleaned ve times/day
Self-cleaning type
Veff [l/h] = 0.29 Peng [kW]

48

M 20 C Generator Set - 08.2012

3.

Systems

3.7.4 Recommendation for lube oil system


For each engine a separate lube oil system is recommended.
Lube oil quantities/change intervals:

Recommended / circulating quantity:


The change intervals depend on:
fuel quality
fuel quality
quality of lube oil treatment (lter, separator)
engine load
By continuous checks of lube oil samples (decisive
are the limit values as per MaK Operating Media)
an optimum condition can be reached.

External lubricating oil piping system information


After bending and welding all pipes must be cleaned by using an approved cleaning process.

Expansion joints
Pipe expansion joints are required to compensate piping movements and vibrations. The bellows are
designed according to the pressure of the medium.

M 20 C Generator Set - 08.2012

49

4.

Connecting parts engine

4.1

Power take-off

The PTO output is limited to 675/750 kW at 900/1,000 rpm.


The connection requires a highly exible coupling.
The primary mass of the exible coupling has to be limited to 56 kg.
A combination (highly exible coupling / clutch) will not be supplied by Caterpillar. The weight force of
the clutch cannot be absorbed by the engine and must be borne by the succeeding machine.
The coupling hub is to be adapted to suit the PTO shaft journal.
The denite coupling type is subject to conrmation by the torsional vibration calculation.

Space for removal of lube oil pump.


50

M 20 C Generator Set - 08.2012

4.

Connecting parts engine

4.2

Resilient mounting of baseframe

4.2.1 Major components


Gensets have to be resiliently mounted.
Resilient elements for insulation of dynamic engine forces and structural-borne noise with integrated
stoppers to limit the engine movements.
Flexible pipe connections for all media
Alignment plates
The ships foundation does not require machining. Unevenness is to be compensated by alignment
plates (to be provided by the shipyard).
Engine type
6 M 20 C
8/9 M 20 C
*

Resilient elements
12 *
14 *

No. of elements can vary, due to genset weight

Important note:
The resilient mounting alone does not provide any guarantee for a silent ship operation. Other
sources of noise like propeller, gearbox and aux. engines have to be considered as well.

M 20 C Generator Set - 08.2012

51

4.

Connecting parts engine

4.2.2 Foundation
6 M 20 C

Alignment tolerance, vertical 1.0 mm

Resilient element with fail-safe


design (horizontal and vertical
stopper)

52

M 20 C Generator Set - 08.2012

4.

Connecting parts engine

8 M 20 C

Alignment tolerance, vertical 1.0 mm

Resilient element with fail-safe


design (horizontal and vertical
stopper)

M 20 C Generator Set - 08.2012

53

4.

Connecting parts engine

9 M 20 C

Alignment tolerance, vertical 1.0 mm

Resilient element with fail-safe


design (horizontal and vertical
stopper)

54

M 20 C Generator Set - 08.2012

4.

Connecting parts engine

4.2.3 Structure-borne sound level LV, expected (measured in the test cell)

Structure borne noise level M 20 C Genset


above/below resilient mounting measured at testbed in Kiel
(values below depend on resilient element type and foundation mobility)
120

sound velocity [dB] ref: v 0 = 5 x 10 -8 m/s

110
100

105

104
98
91

89

87

90

87

85
79

77

80
70

73

71

70

67

64

62
58

60

56
50

50
40

40
30

above resilient mounting


below resilient mounting

20
10

SUM

8000

4000

2000

1000

500

250

125

63

31,5

frequency 1/1 octave band [Hz]

tolerance: +/- 2 dB

Engine movement due to vibration referred to the global vibration characteristics of the engine:
The basis for assessing vibration severity are the guidelines ISO 10816-6.
According to these guideline, the MaK engine will be assigned to vibration severity grade 28, class 5.
On the engine block the following values will not be exceeded:
Displacement
Vibration velocity
Vibration acceleration

M 20 C Generator Set - 08.2012

Seff
Veff
aeff

< 0.448 mm
< 28.2 mm/s
< 44.2 m/s

f > 2 Hz < 10 Hz
f > 10 Hz < 250 Hz
f > 250 Hz < 1000 Hz

55

4.

Connecting parts engine

4.3

Generators structural requirements for MaK diesel gensets M 20 C


Assembly control dimension XX and end oat marked on the bearing

* Bore distances without tolerances 0.8 mm,


the location of the holes has to be agreed

Mounting ap for anti-condensation heater is required above the mounts


With air cooling the air outlet is required above the mounts
Plain bearings must be removable without coupling removal
Type
6 M 20 C
8 M 20 C
9 M 20 C

56

Stator
design

D max.

B 20

1,210

1,350

1,200

200

285

150

22

250

M 20 C Generator Set - 08.2012

5.

Installation and Arrangement

5.1

General installation aspect

Inclination angles of ships at which engine running must be possible:


Rotation X-axis:
Static: heel to each side:
Dynamic: rolling to each side:

15 C
22.5 C

Rotation Y-axis:
Static: trim by head and stern:
Dynamic: pitching:

5 C
7.5 C

M 20 C Generator Set - 08.2012

57

5.

Installation and Arrangement

5.2

System connections engine

C15
C21
C22
C23
C25
C28
C37
C39
C60
C61
C62a
C73
C75
C78
C81b
C86
C91
C91a

Charge air cooler LT, outlet


Freshwater pump HT, inlet
Freshwater pump LT, inlet
Freshwater dtand-by pump HT, inlet
Freshwater, outlet
Freshwater pump LT, outlet
Vent
Drain cooling water
Separator connection, suction side
Separator connection, delivery side
Drain pre lube pump
Fitted fuel pump, inlet
Fuel stand-by pump, connection
Fuel, outlet
Fuel duplex lter, drip oil
Starting air
Crankcase ventilation
Exhaust gas outlet
6 M 20 C
8/9 M 20 C

DN 50
DN 65
DN 65
DN 50
DN 50
DN 50
DN 10
DN 25
DN 32
DN 32
DN 32
DN 20
DN 20
DN 20
DN 10
DN 40
DN 50
DN 400
DN 500

C91

C75
C78
C28
C23
C73

C22

C81b
C39

C62a
C61

C60

C91a

C86

C37
C25
C15
C21

58

M 20 C Generator Set - 08.2012

5.

Installation and Arrangement

5.3

Space requirement for dismantling of charge air cooler and turbocharger cartridge

Charge air cooler cleaning


Cleaning is carried out with charge air cooler dismantled. A container to receive the cooler and cleaning
liquid is to be supplied by the yard. Intensive cleaning is achieved by using ultrasonic vibrators.
Turbocharger removel / maintenance
Caterpillar recommends to provide a lifting device above the bearing housing of the turbocharger (see
B).
Weight of turbocharger [kg]
Turbocharger
complete
6 M 20 C
236
8/9 M 20 C
354

Silencer

M 20 C Generator Set - 08.2012

25
55

Dimensions [mm]

Compressor Turbine CarRotor


housing
housing tridge
46
87

51
87

54
88

13
20

515
670

268
276

892 1,330
1,025 1,400

E
830
910
59

5.

Installation and Arrangement

5.4

Installation of exible pipe connections

Flexible pipe connections become necessary to connect resilient mounted engines with external
piping systems. These components have to compensate the dynamic movements of the engines in
relation to the external piping system.
The shipyards pipe system must be accurately arranged so that anges or screw connections do t
without lateral or angular offset. It is recommended to adjust the nal position of the pipe connections
after engine alignment is completed.
It is important to provide support as close as possible to the exible connection and stronger as usual.
The pipes outside the exible connection must be well xed and clamped to prevent vibrations, which
could damage the exible connections.

Installation of steel expansion joints


Steel expansion joints can compensate movements in line and transversal to their center line. They
are not for compensating twisting movements. Expansion joints are very stiff against torsion.

5.5

Notes regarding installation exhaust system

Arrangement of the rst expansion joint directly on the transition pipe


Arrangement of the rst xed point in the conduit directly after the expansion joint
Drain opening to be provided (protection of turbocharger and engine against water)
Each engine requires one individual exhaust gas pipe (a common pipe for several engines is not
permissible).

During commissioning and maintenance work, checking of the exhaust gas back pressure by means
of a temporarily connected measuring device may become necessary.
For this reason, a measuring socket is to be provided approx. 1 - 2 m after the exhaust gas outlet of the
turbocharger at an easily accessible place.
If it should be impossible to use standard transition piece supplied by Caterpillar, the weight of the
transition piece manufactured by the shipyard must not exceed the weight of the standard transition
piece. A drawing including the weight will then have to be submitted for approval.

60

M 20 C Generator Set - 08.2012

5.

Installation and Arrangement

5.6

Installation of crankcase ventilation on the engine

For the piping of crankcase ventilations please consider the following design criteria:

Outlet crankcase ventilation has to be arranged separately for each engine


The pipes should run upwards
A free ventilation under all trim conditions
Condensate backow into crankcase has to be prevented
Provide a permanent drain

Main vent pipe

Expansion joint for resilient


mounting engine

Drain

Piping sizes for crankcase ventilation


Engine Type

Engine connecting
point(s)

Main vent pipe

6/8/9 M 20 C

2 x DN 50

2 X DN 65

M 20 C Generator Set - 08.2012

Collecting vent with


lubricating oil circulation
tank (observe class rules)
DN 80

61

5.

Installation and arrangement

5.7

Earthing of the engine

Information about the execution of the earthing


The earthing has to be carried out by the shipyard during assembly on board. The engine already has
M 16, 25 mm deep threaded holes with the earthing symbol in the engine foot. If the engine is resiliently
mounted, it is important to use exible conductors.
In case of using welding equipment it is important to earth the welding equipment close to the welding
area (the distance should not exceed 10 m).

Earthing connection on the engine

62

M 20 C Generator Set - 08.2012

5.

Installation and Arrangement

5.8

Lifting of the engine

For the purpose of transport the genset is equipped with a lifting device which shall remain the property
of Caterpillar. It has to be returned in a useable condition free of charge.

M 20 C Generator Set - 08.2012

63

6.

Control and monitoring system

6.1

Engine control panel


Detail X

Detail X
2 = REMOTE
1 = ENGINE
0 = REPAIR

Engine speed

Stop lever

1 2

Engine

Start
Stop

64

Start
Stop

M 20 C Generator Set - 08.2012

6.

Control and monitoring system

6.2

Genset control

*)

Alarm system /
exhaust gas temp.
monitoring system

*) not in Caterpillar scope of supply


note: 24V DC supply 20 %

alarms

*)

alarm signal

alarms

minor alarm

Main Switch Board (MSB)


Diesel start automatic
- remote start / stop
- emergency start
- emergency stop
- main breaker ON / OFF
- frequency control
- synchronizing
- etc.

control signals

alarms via MODbus

Power Management
System (PMS)

shut down signal

manual emergency stop signal

Emergency
stop

control signals

Engine
speed
(optional)

0-10 V DC / 4-20 mA

TC
speed
(optional)

*)

LESS

Next genset
-> if available

Large
Engine
Safety
System
Protection system,
Start / stop, display

Next electronic
speed governor
-> if available
load sharing

*)

control signals

24V DC

*)

Electronic speed governor

24V DC

control signals
actuator control

LESS
Large Engine Safety System
data convertet

actuator

CANbus

24V DC

*)

Alternator
(optional)

Generator
voltage
regulateur
(optional)

Cooling water
preheating system
( optional)

voltage supply
(3 phase)

M 20 C Generator Set - 08.2012

*)

65

6.

Control and monitoring system

6.3

Engine monitoring
Junction box

Yard connection

Pressure switch arrangement

Junction box and LESS-cabinet are connected via CANbus (see LESS description)

LESS protection system

66

LESS display

LESS-cabinet

M 20 C Generator Set - 08.2012

6.

Control and monitoring system

6.4

Measuring points

Meas. Point

Description

1105

Pressure transmitter
Lube oil pressure low pre-alarm shut dowm

1106

Pressure switch
Lube oil pressure low shut down

1112.1
1112.2

Differential pressure lube oil automatic lter high


pre-alarm
Differential pressure lube oil automatic lter high
alarm

Sensor
range

Remarks

4-20 mA
binary
binary
binary

1142

Pressure switch
Pre lube oil pressure low start interlock

binary

1202

Resistance thermometer
Lube oil temp. at engine inlet high alarm

PT 100

1203

Resistance thermometer
Lube oil temp. at engine inlet high shutdown

PT 100

1 evaluation unit for


1112.1/.2
Only exhist when aut.-lter
is mounted on engine

Oil mist detector VN115/87 Plus

1251

1251 Oil mist concentration in crankcase high alarm

1251:
binary

1251.1

1251.1 Oil mist concentration in crankcase high Pre-alarm

1251.2

1251.2 Opacity

1251.2:
4-20 mA

1253:

1 evaluation unit for


1251, 1253 ,9631

1251.1 (70% from 1251)

1253

1253 Oil mist concentration in crankcase high shut down

9631

9631 Oil mist detector failure alarm

1311

Level probe/switch unit


Lube oil level low alarm

binary

1312

Level probe/switch unit


Lube oil level high alarm

binary

2102

Pressure transmitter
Cooling water pressure HT at engine inlet low alarm

4-20 mA

40 kPa below
operating pressure

2103

Pressure switch
Cooling water pressure HT at engine inlet low shut down

binary

60 kPa below operating


pressure stop delay: 20s

2112

Pressure transmitter
Cooling water pressure LT at engine outlet low alarm

4-20 mA

40 kPa below
operating pressure

2201

Resistance thermometer
Cooling water temp. HT at engine inlet low alarm

PT 100

2211

Resistance thermometer
Cooling water temp. HT at engine outlet high alarm

PT 100

2213

Resistance thermometer
Cooling water temp. HT at engine outlet high shut down

PT 100

M 20 C Generator Set - 08.2012

binary

9631:
binary

67

6.

Control and monitoring system

Meas. Point

Description

2229

Resistance thermometer
Cooling water temp. LT at engine inlet high alarm

5102

Pressure transmitter
Fuel oil pressure at engine inlet low alarm

5111

Differential pressure indicator


Differential pressure fuel oil lter high alarm

Sensor
range

Remarks

PT 100
4-20 mA
binary

Resistance thermometer

5201/5202* 5201 Fuel oil temp. at engine inlet low alarm


5202* Fuel oil temp. at engine inlet high alarm
Fuel oil temp. after viscomat DICARE
5206

68

PT 100

1 sensor for 5201 + 5202*


* not in use with HFO

PT 100

Not mounted on engine


Not mounted on engine

5253

Fuel oil viscosity at viscomat DICARE

4-20 mA

5301

Level probe/switch unit


Leakage oil level at engine high alarm

binary

6101

Pressure transmitter
Starting air at engine inlet low alarm

4-20 mA

6105

Pressure switch
Stopping air pressure at engine low alarm

binary

6181

Absolute pressure transmitter


Intake air pressure in engine room DICARE

4-20 mA

7109

Pressure transmitter
Charge air pressure at engine inlet indication

4-20 mA

7201

Resistance thermometer
Charge air temp. at engine inlet high alarm

PT 100

7206

Resistance thermometer
Intake air temp. at turbocharger inlet DICARE

PT 100

7301

Level probe/switch
Condense water in charge air canal

binary

7307

Differential pressure transmitter


Charge air diff. pressure at charge air cooler DICARE

4-20 mA

7309

Thermocouple type K
Charge air temp. at charge air cooler inlet DICARE

NiCr-Ni
(mV)

8211.1

Thermocouple type K
Exhaust gas temp. after cylinder 1 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8211.2

Thermocouple type K
Exhaust gas temp. after cylinder 2 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8211.3

Thermocouple type K
Exhaust gas temp. after cylinder 3 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8211.4

Thermocouple type K
Exhaust gas temp. after cylinder 4 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

Alarm delay: 2s

M 20 C Generator Set - 08.2012

6.

Control and monitoring system

Meas. Point

Description

Sensor
range

Remarks

8211,5

Thermocouple type K
Exhaust gas temp. after cylinder 5 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8211.6

Thermocouple type K
Exhaust gas temp. after cylinder 6 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8211.7

Thermocouple type K
Exhaust gas temp. after cylinder 7 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8211.8

Thermocouple type K
Exhaust gas temp. after cylinder 8 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8211.9

Thermocouple type K
Exhaust gas temp. after cylinder 9 high high

NiCr-Ni
(mV)

Load depended alarm delay:


16s

8212.1 to
8212.9

Exhaust gas temp. absolute after cyl. 1 to 9 alarm

Alarm from exhaust gas


temp. system, has to be
created in the EGTS

8213.1 to
8213.9

Exhaust gas temp. deviation from mean average cyl.


1 to 9 alarm

Alarm from exhaust gas


temp. system, has to be
created in the EGTS

8216
8218

8221
8224

Deviation of mean average value reduct alarm cyl.


shut down

Included in meas. Point 8234


from alarm system to (EGTS)
LESS

Exhaust gas temp. reduct alarm of each cyl. absolute


shut down

Included in meas. Point 8234


from alarm system to (EGTS)
LESS

Thermocouple type K
Exhaust gas temp. at turbocharger outlet

NiCr-Ni
(mV)

Included in meas. Point 8234


from alarm system to (EGTS)
LESS

Exhaust gas temp. reduction alarm of turbocharger


outlet

8231.1

Thermocouple type K
Exhaust gas temp. at turbocharger inlet indication

NiCr-Ni
(mV)

8231.2

Thermocouple type K
Exhaust gas temp. at turbocharger inlet indication

NiCr-Ni
(mV)

8231.3

Thermocouple type K
Exhaust gas temp. at turbocharger inlet indication

NiCr-Ni
(mV)

Common alarm exhaust gas temp. monitoring


load reduction included 8216, 8218, 8224

binary

R1

Resistance thermometer, terminal set A02-1-X40


Temperature compensation thermocouples

PT 100

R2

Resistance thermometer, socket X2.1


Temperature compensation thermocouples

PT 100

R16

Resistance thermometer
Electronical charge air temp. control

PT 100

8234

M 20 C Generator Set - 08.2012

Load depended alarm delay.


16s

Common alarm from alarm


system to (EGTS) LESS

69

6.

Control and monitoring system

Meas. Point

Sensor
range

Remarks

9401.1

Suppression of alarms

binary

To be created in alarm system;


Alarm system received the
engine rpm signal via MODbus
(plant specic)

9401.2

Fresh water pre-heater switch on / off

binary

Hardwired to CW-preheating
control (plant specic)

9401.3

Engine is running n > n_min

binary

Hardwired to PMS (plant


specic)

9402

Pre lube oil pump switch on / off

binary

Option
Hardwired to yard supplied
pumpcontrol (plant specic)

9404

Relay contact
Overspeed - shut down

binary

1.15 x n rated

9419

Engine speed signal

4-20 mA

683.3 Hz = 0-1,000 rpm

9419.1

Pick up
RPM switching equipment

0-15 KHz

9419.2

Pick up
RPM switching equipment

0-15 KHz

9419.3

Pick up
Electronic governor

0-900 Hz

9419.4

Pick up
Electronic governor

0-15 KHz

9429

Pick up / transmitter
Turbine speed high - alarm*
Turbine speed - indication

9503

Limit switch
Control level at fuel rack - stop position

9509

Distance sensor / switching device


Fuel setting

4-20 mA

9532.1

Engine fuel rack position

4-20 mA

Hardwired to PMS (plant


specic)

9532.2

Engine fuel rack position

4-20 mA

Spare (plant specic)

9532.3

Engine fuel rack position

0-10 V

Option
Hardwired to exhaust gas temp.
(plant specic)

9561

Limit switch
Turning gear engaged - starting interlock

binary

Start blocking (plant


specic)

9602

Relay contact
CANbus failure - alarm

binary

9609
9615
70

Description

4-20 mA
0-10 V
binary

From power management system (PMS) - start interlock


Trouble at electronic speed governor - alarm

* DNV
to be created in alarm
system

Start blocking
binary

Hardwired to alarm system

M 20 C Generator Set - 08.2012

6.

Control and monitoring system

Meas. Point

Description

9616

Trouble at electronic speed governor - shut down

9735

From power management system (PMS) - shut down

Sensor
range

Remarks
Pick up fault, Actuator wire
break
Generator protection
shutdown

9836.1

Relay contact
Sensor / isolation fault A01.1 - alarm

binary

Hardwired to alarm system

9836.2

Relay contact
Sensor / isolation fault A03.1 - alarm

binary

Hardwired to alarm system

9962.1

Relay contact
Common alarm A01.1 - alarm

binary

Hardwired to alarm system

9962.2

Relay contact
Common alarm A03.1 - alarm

binary

Hardwired to alarm system

9671.1

Relay contact
Automatic stop failure - alarm

binary

Hardwired to alarm system

9671.2

Relay contact
Overspeed failure - alarm

binary

Hardwired to alarm system

9671.3

Relay contact
Emergency stop failure - alarm

binary

Hardwired to alarm system

9674

Relay contact
Automatic stop / PLC A01 common - shut down

binary

Hardwired to alarm system

9675

Relay contact
Emergency stop - alarm

binary

Hardwired to alarm system

Voltage fail at charge air temp. controller - alarm

binary

plant specic

Fresh water preheater voltage failure - alarm

binary

plant specic

Blackout - alarm

binary

plant specic

9751.1
9771
9828

M 20 C Generator Set - 08.2012

71

6.

Control and monitoring system

6.5

Local and remote indicators


TC
speed
(optional)

4-20 mA

4-20 mA

Remote indicators
(optional)

Engine
speed
(optional)

*)

MODbus

0-10 V DC / 4-20 mA

Alarm system /
exhaust gas temp.
monitoring system

Analogue sensors

Diesel Engine

Local indicators
Installed at the engine

Remote indicators
96 x 96mm (optionally)

Fuel oil temperature at engine inlet

X 2)

Lueb oil temperature at engine inlet

X 2)

Lube oil temperature at oil cooler inlet


Fresh water temperature at engine inlet (HT circuit)
Fresh water temperature at engine outlet (HT circuit)

X 2)

Fresh water temperature at cooler inlet


Fresh water temperature at cooler outlet
Charge air temperature at cooler inlet
Charge air temperature at engine inlet
Fuel oil pressure

X 2)

Lube oil pressure

X 2)

Fresh water pressure (HT circuit)

X 2)

Fresh water pressure (LT circuit)

X 2)

Starting air pressure

X 2)

Charge air pressure


Engine speed

X 1)

Turbocharger speed (not indicated at engine)

Exhaust gas temp. at turbocharger outlet


1)
2)

72

144 x 144 mm possible


Signal is supplied by the alarm system
M 20 C Generator Set - 08.2012

6.

Control and monitoring system

6.6

LESS: Large Engine Safety System

LESS-cabinet includes

Engine protection system


Speed switch unit
Start-/stop-control
Alarm display (LED)
Graphic display (settings)
Engine monitoring
MODbus output to alarm system (MODbus RTU protocol RS 482 / 422)
Exhaust gas temperature mean value system (optional for diesel-electric-drive)
Electronic governor (optional installed for diesel-electric-drive)

System data
Inputs:
4 xed automatic shut down + overspeed inputs
4 manual emergency stop inputs
16 congurable inputs for shutdown, load reduce request or start interlock
2 separate override inputs
1 remote reset input
All inputs are wire break- and short circuit monitored.
Outputs:
4 x 2 adjustable speed contacts
3 fuel setting signals (1 x 0-10V DC, 2 x 4-20 mA)
1 overload contact at rated speed
4 speed signals (1 x pulse, 1 x 0-10V DC, 2 x 4-20 mA or 0-10V DC congurable)

M 20 C Generator Set - 08.2012

73

6.

Control and monitoring system

Alarm
System
(optionally
Caterpillar supply)

MODbus
ENGINE JUNCTION BOX
MONITORING

A03.1

Sensor signals

MODbus
(optional)

CAN-bus
NORIS CONTROL CABINET

START-STOP

A01.1

START-STOP

A01.2

PROTECTION

A05.1

i-bus

hardwired
Control
signals

Start interlocks
DISPLAY

A01.5

N3000-DSP

Shutdown signals

Pickup Shutdown
signals valve

Override inputs
Reset input

74

M 20 C Generator Set - 08.2012

7.

Diagnostic trending monitoring DICARE

With MaK DICARE, you can have an expert aboard at all times, ready to serve your needs. The latest,
completely revised version combines well-established features with faster signal processing and
improved usability, based on common industry standards.
Cat and MaK engines with MaK DICARE remote engine monitoring software provide reliable, conditionspecic maintenance suggestions. DICARE continually compares current engine condition to desired
state and tells you when maintenance is required. You get the diagnostics you need in easy-tounderstand words and graphics so you can take action to keep your engines running strong.
DICARE is only available for medium-speed engines not for high-speed engines.
About 700 MaK engines worldwide, on vessels and in power stations ashore, are currently supervised
with DICARE. Malfunctions are indicated immediately and at a glance, taking into account empirical
data, plausibility considerations, and built-in expertise from decades of MaK diesel engine design. For
ease of use, the initial report is subdivided into the diagnostic sectors of exhaust gas, turbocharger,
fuel oil, lube oil, and cooling water, using a simple color-coding of regular versus irregular values. In
a second step, the complete set of measured values and detailed troubleshooting instructions can be
displayed, also with recommended actions priority-coded.
Special attention is placed on monitoring the following criteria:

Overall temperature levels to identify thermal overload at an early stage.


Intake air pressure and temperature to identify performance drops due to fouling or wear.
Charge air pressure, temperature and dew point to identify fouling or misadjustment.
Fuel temperature and viscosity to identify any malfunction of the viscosity control unit.
Fuel rack position and power output to identify injection pump wear.
Lube oil consumption to identify any possible wear.
Cooling water pressure and temperature for optimum operation.
Exhaust gas temperatures to identify deviations in the fuel or air system at an early stage.

M 20 C Generator Set - 08.2012

75

7.

Diagnostic trending monitoring DICARE

Transmitter for DICARE ON-LINE M 20 C CANbus

Designation
Fuel viscosity
Fuel temperature after viscomat

5206

Fuel temperature at engine inlet

5201

Injection pump rack position

9509

Lube oil pressure

1105

Lube oil temperature at engine inlet

1202

Freshwater pressure HT

2102

Freshwater temperature at engine inlet HT

2201

Freshwater temperature at engine outlet HT

2211

Differential pressure charge air cooler

7307

Intake air pressure

6181

Intake air pressure before turbocharger

7206

Charge air pressure after intercooler

7109

Charge air temperature before intercooler

7309

Charge air temperature at engine inlet

7201

Exhaust gas temperature for each cylinder and


after turbocharger
Exhaust gas temperature before turbocharger

76

Meas. point no.


CM
5253

8211/8221
8231

Engine speed

9419

Turbocharger speed

9429

Service hour counter (manual input)

9409

M 20 C Generator Set - 08.2012

8.

Engine acceptance test

Standard acceptance test run


The acceptance test run is carried out on the testbed with customary equipment and auxiliaries using
exclusively MDO and under the respective ambient conditions of the testbed. During this test run the
fuel rack will be blocked at the contractual output value. In case of deviations from the contractual
ambient conditions the fuel consumption will be converted to standard reference conditions.
The engine will be run at the following load stages acc. to the rules of the classication societies. After
reaching steady state condition of pressures and temperatures these will be recorded and registered
acc. to the form sheet of the acceptance test certicate:
Load [%]
50
85
100
110

Duration [min]
30
30
60
30

Additional functional tests


In addition to the acceptance test run the following functional test will be carried out:

governor test
overspeed test
emergency shut-down via minimum oil pressure
start/stop via local engine control
starting trials down to the minimum air pressure
measurement of crank web deection (cold/warm condition)

After the acceptance test run main running gear, camshaft drive and timing gear train will be inspected
through the opened covers. Individual inspection of special engine components such as a piston or
bearings is not intended, because such inspections are carried out by the classication societies at
intervals on production engines.

M 20 C Generator Set - 08.2012

77

9.

Engine International Air Pollution Prevention Certicate

The MARPOL Diplomatic Conference has agreed about a limitation of NOx emissions, referred to as
Annex VI to Marpol 73/78.
When testing the engine for NOx emissions, the reference fuel is Marine Diesel Oil (Distillate) and the
test is performed according to ISO 8178 test cycles:

Speed
Power
Weighting factor

Test cycle type E2


Test cycle type D2
100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 %
100 % 75 % 50 % 25 % 100 % 75 % 50 % 25 % 10 %
0.2
0.5
0.15
0.15
0.05
0.25
0.3
0.3
0.1

Subsequently, the NOx value has to be calculated using different weighting factors for different loads
that have been corrected to ISO 8178 conditions.

An NOx emission evidence will be issued for each engine showing that the engine complies with the
regulation. The evidence will come as EAPP (Engine Air Pollution Prevention) Statement of Compliance,
EAPP (Engine Air Pollution Prevention) Document of Compliance or EIAPP (Engine International Air
Pollution Prevention) Certicate according to the authorization by the ag state and related technical
le. For the most part on basis of an EAPP Statement of Compliance or an EAPP Document of Compliance
an EIAPP certicate can be applied for.

According to IMO regulations, a Technical File shall be prepared for each engine. This Technical File
contains information about the components affecting NOx emissions, and each critical component is
marked with a special IMO number. Such critical components are piston, cylinder head, injection nozzle
(element), camshaft section, fuel injection pump, turbocharger and charge air cooler. (For Common
Rail engines the controller and the software are dened as NOx relevant components instead of the
injection pump.) The allowable setting values and parameters for running the engine are also specied
in the Technical File.

The marked components can later, on-board the ship, be easily identied by the surveyor and thus
an IAPP (International Air Pollution Prevention) certicate for the ship can be issued on basis of the
EIAPP certicate and the on-board inspection.

78

M 20 C Generator Set - 08.2012

10. Painting / preservation

Inside preservation
N 576-3.3
The preservation is sufcient for a period of max. 2 years.
It needs to be removed when the engine is commissioned!
Main running gear and internal mechanics

Outside preservation
VCI 368 N 576-3.2
Engine outside preservation with Cortec VCI 368 is applicable for Europe and overseas.
It applies for sea and land transportation and storage of the engines in the open, protected from moisture.
The duration of protection with additional VCI packaging is max. 2 years.
It must be removed before commissioning of the engines! Environmentally compatible disposal is to
be ensured.
Durability and effect are determined by proper packaging, transportation, and storage, i.e. protected
from moisture, stored at a dry place and sufciently ventilated. Inspections are to be carried out at
regular intervals.
Appearance of the engine:
Castings with red oxide antirust paint
Pipes and machined surfaces left as bare metal
Attached components with colours of the makers
N 576-4.1 - Clear Varnish
Clear varnish painting is applicable within Europe for land transportation with protection from moisture.
It is furthermore applicable for storage in a dry and tempered atmosphere.
Clear varnish painting is not permissible for:
Sea transportation of engines
Storage of engines in the open, even if they are covered with tarpaulin
The duration of protection with additional VCI packaging is max. 1 year.
VCI packaging as per N 576-5.2 is generally required!
Durability and effect are determmined by proper packaging, transportation, and storage, i.e. the engine
is to be protected from moisture, VCI lm not ripped or destroyed.
Inspections are to be carried out at regular intervals.
M 20 C Generator Set - 08.2012
79

10. Painting / preservation

If the above requirements are not met, all warranty claims in connection with corrosion damage shall
be excluded.
Appearance of the engine:
Catings with red oxide antirust paint
Pipes and machined surfaces left as bare metal
Attached components with colours of the makers
Surfaces sealed with clear varnish
Bare metal surfaces provided with VCI 368 preservation
N 576-4.3 - Painting
The painting is applicable for Europe and overseas.
It applies for sea and land transportation and short-term storage in the open (protected from moisture)
up to max. 4 weeks.
In case of Europe and overseas shipment and storage in the open longer than 4 weeks VCI packaging
as per N 576-5.2 is required.
The duration of protection with additional VCI packaging is max. 2 years.
Durability and effect are determined by proper packaging, transportation, and storage, i.e. protected
from moisture, VCI lm not ripped or destroyed. Inspections are to be carried out at regular intervals.
Appearance of the engine:
Surfaces mostly painted with varnish
Bare metal surfaces provided provided with VCI 368 preservation
N 576-5.2 - VCI packaging
Corrosion protection with VCI packaging applies for:
Engines with outside preservation VCI 368 as per N 576-3.2
Engines with clear varnish according to application group N 576-4.1
These engines are always to be delivered with VCI packaging!
Nevertheless, they are not suitable for storage in the open!
Engines or engine generator sets with painting according to application group N 576-4.3 for shipment
to Europe and overseas or storage in the open (protected from moisture).

80

M 20 C Generator Set - 08.2012

10. Painting / preservation

Durability and effect are determined by proper packaging, transportation, and storage, i.e. protected
from moisture, VCI lm not ripped or destroyed. Inspections are to be carried out at regular intervals.
Bare metal surfaces provided with VCI 368 or VCI oil
Cortec VCI impregnated exible PU foam mats hung up on the engine using tie wraps. Kind and
scope depending on engine type.
The mats are to be hung up in free position and should not come into contact with the painted
surface.
Cover the engine completely with air cushion lm VCI 126 LP. Air cushions are to point towards the
inside!
The air cushion lm is fastened to the transportation skid (wooden frame) by means of wooden
laths. Overlaps at the face ends and openings for the lifting gear are to be closed by means of PVS
scotch tape.
In case of engines delivered without oil pan the overhanging VCI lm between engine and transport
frame is to be folded back upwards towards the engine before fastening the air cushion lm.
Attention! The corrosion protection is only effective if the engine is completely wrapped with VCI lm.
The protective space thus formed around the component can be opened for a short time by slitting the
lm, but afterwards it must be closed again by means of adhesive tape.
N 576-5.2 Suppl. 1 - Information panel for VCI preservation and inspection
Applies for all engines with VCI packaging as per application group N 576-5.2.
Description:
This panel provides information on the kind of initial preservation and instructions for inspection.
Arranged on the transport frame on each side so as to be easily visible.
N 576-6.1 - Corrosion Protection Period, Check, and Represervation
There will only be an effective corrosion protection of the engine if the denitions and required work
according to factory standard N 576-6.1 are duly complied with.
Normally, the applied corrosion protection is effective for a period of max. 2 years if the engines
or engine generator sets are protected from moisture. However, depending on the execution of the
preservation shorter periods may be applicable.
After 2 years represervation must be carried out.
Every 3 months specic inspections are to be carried out the engine or engine generator set at dened
inspection points. Any corrosion that is found and existing condensation water are to be removed
immediately.

M 20 C Generator Set - 08.2012

81

11. Engine parts

Cylinder head, weight 91.5 kg

Connecting rod, weight 38.7 kg

82

Piston with connecting rod, weight 78 kg

Cylinder liner, weight 60 kg

M 20 C Generator Set - 08.2012

12. Caterpillar Marine Systems Integration

12.1

The Scope

Caterpillar Marine Systems Integration


Mechanical
Propulsion Systems

Electrical
Propulsion Systems
Gensets
E-Motors
Propeller
Thruster
Fuel Oil System for LNG
Fuel Oil System for HFO/MDO
Heat Recovery Systems
Exhaust Gas Cleaning Systems

Electric Propulsion Switchboard

Electric Board Net Switchboard

Power Management System

Communication Systems Dynamic Positioning System Ship Automation, Safety & Monitoring System
Navigation System

Control Consoles & Control Stations

Caterpillar Marine Systems Integration provides:


System consultancy (feasibility studies)
Systems integration engineering
Design and construction drawings

M 20 C Generator Set - 08.2012

83

13. Appendix

13.1

Exhaust system

13.1.1 Resistance in exhaust gas piping

Example (based on diagram data A to E):


t
= 335 C, G = 25,000 kg/h
l
= 15 m straight pipelength, d = 700 mm
3 off 90 bent R/d = 1.5
1 off 45 bent R/d = 1.5
Pg = ?
p
L
L
Pg

84

= 0.83 mm WC/m
= 3 11 m + 5.5 m
= l + L = 15 m + 38.5 m = 53.5 m
= p L = 0.83 mm WC/m 53.5 m = 44.4 mm WC

t
G
p
d
w
l
L
L
Pg

= Exhaust gas temperature


= Exhaust gas massow
= Resistance/m pipe length
= Inner pipe diameter
= Gas velocity
= Straight pipe length
= Spare pipe length of 90 bent pipe
= Effective substitute pipe length
= Total resistance

(C)
(kg/h)
(mm WC/m)
(mm)
(m/s)
(m)
(m)
(m)
(mm WC)

M 20 C Generator Set - 08.2012

13. Appendix

13.1.2 Exhaust data


Output/cylinder:
Speed:
Tolerance:
Atmospheric pressure:
Relative humidity:
Constant speed

170 kW
900 1/min
5%
1 bar
60 %

Intake air temperature:

25 C

Output
[kW]

6 M 20 C

1,020

8 M 20 C

1,360

9 M 20 C

1,530

100
7,580
340
11,420
290
12,850
300

Intake air temperature:

90
6,910
346
10,460
290
11,810
300

1,020

8 M 20 C

1,360

9 M 20 C

1,530

M 20 C Generator Set - 08.2012

60
4,688
365
7,260
308
8,125
300

50
4,155
373
6,205
320
6,980
300

Output %
[kg/h]
[C]
80
70
5,835
5,140
372
377
8,970
7,850
309
324
10,050
8,820
316
315

60
4,425
387
6,850
327
7,665
318

50
3,920
395
5,850
339
6,585
320

45 C

Output
[kW]

6 M 20 C

Output %
[kg/h]
[C]
80
70
6,185
5,445
350
356
9,508
8,320
290
306
10,660
9,350
300
300

100
7,150
362
10,775
309
12,120
320

90
6,518
367
9,867
310
11,140
318

85

13. Appendix

13.1.2 Exhaust data


Output/cylinder:
Speed:
Tolerance:
Atmospheric pressure:
Relative humidity:
Constant speed

190 kW
900 1/min
5%
1 bar
60 %

Intake air temperature:

25 C

Output
[kW]

6 M 20 C

1,140

8 M 20 C

1,520

9 M 20 C

1,710

100
8,395
345
11,723
330
13,180
337

Intake air temperature:

90
7,814
350
11,067
316
12,450
333

1,140

8 M 20 C

1,520

9 M 20 C

1,710

86

60
5,704
357
8,075
313
9,085
347

50
4,676
360
7,055
314
7,940
358

Output %
[kg/h]
[C]
80
70
6,670
6,155
376
376
9,615
8,690
331
329
10,810
9,775
351
355

60
5,380
378
7,620
332
8,570
368

50
4,410
382
6,655
333
7,490
380

45 C

Output
[kW]

6 M 20 C

Output %
[kg/h]
[C]
80
70
7,070
6,524
355
355
10,190
9,211
312
310
11,460
10,360
331
335

100
7,920
366
11,060
350
12,435
357

90
7,370
371
10,440
335
11,745
353

M 20 C Generator Set - 08.2012

13. Appendix

13.1.3 Exhaust gas sound power level


Exhaust gas sound power level
MaK 6 M 20 C
(to be expected directly after turbo charger at open pipe (A0=1m), values measured with a probe inside the exhaust gas pipe)

140
127

-12

sound power level [dB(A)] ref: 10 W

130

129

129

127

122

124
118

120
112
110
100

98

90
80
70
60
31,5

63

125

250

500

1000

2000

4000

8000

1/1 octave band frequency [Hz]

tolerance: +/- 2 dB

Exhaust gas sound power level


MaK 8 M 20 C
(to be expected directly after turbo charger at open pipe (A0=1m), values measured with a probe inside the exhaust gas pipe)

140
130

-12

sound power level [dB(A)] ref: 10 W

130

127

130

128

126

122

120

120
112
110
100

97

90
80
70
60
31,5

63

125

250

500

1000

2000

4000

8000

1/1 octave band frequency [Hz]

tolerance: +/- 2 dB

M 20 C Generator Set - 08.2012

87

13. Appendix

13.1.3 Exhaust gas sound power level


Exhaust gas sound power level
MaK 9 M 20 C
(to be expected directly after turbo charger at open pipe (A0=1m), values measured with a probe inside the exhaust gas pipe)

128

131

129

128
122

-12

sound power level [dB(A)] ref: 10 W

123

131

112

97

1/1 octave band frequency [Hz]

tolerance: +/- 2 dB

88

M 20 C Generator Set - 08.2012

13. Appendix

13.2

Air-borne sound power level


Air-borne sound power level
MaK 6 M 20 C Genset
measured in test cell according EN ISO 9614-2

sound power level [dB(A) re: 10

-12

W]

120

116

115
108

110

110

111

1000

2000

108

105
105
100
95
95
90

86

85
80
75
70
63

125

250

500

4000

SUM

1/1 Octave [Hz]


tolerance: +/- 2 dB

Air-borne sound power level


MaK 8 M 20 C Genset
measured in test cell according EN ISO 9614-2

sound power level [dB(A) re: 10

-12

W]

120

117

115
110

111

112

110

106

105
105
100
93

95
90

88

85
80
75
70
63

125

250

500

1000

2000

4000

SUM

1/1 Octave [Hz]


tolerance: +/- 2 dB

M 20 C Generator Set - 08.2012

89

13. Appendix

13.2

Air-borne sound power level


Air-borne sound power level
MaK 9 M 20 C Genset
measured in test cell according EN ISO 9614-2

sound power level [dB(A) re: 10

-12

W]

120
115

109

110

118

111

111

112

500

1000

2000

109

105
99

100
95
90

89

85
80
75
70
63

125

250

4000

SUM

1/1 Octave [Hz]


tolerance: +/- 2 dB

90

M 20 C Generator Set - 08.2012

Caterpillar Marine Power Systems


Headquarters

Europe, Africa, Middle East

Americas

Asia Pacific

Caterpillar Marine
Power Systems
A Division of
Caterpillar Motoren GmbH & Co.KG
Neumhlen 9
22763 Hamburg/Germany

Caterpillar Marine
Power Systems
A Division of
Caterpillar Motoren GmbH & Co.KG
Neumhlen 9
22763 Hamburg/Germany

MaK Americas Inc.

Caterpillar Marine Trading


(Shanghai) Co., Ltd.

3450 Executive Way


Miramar Park of Commerce
Miramar, FL. 33025/USA

25/F, Caterpillar Marine Center


1319, Yanan West Road
200050 Shanghai/P. R.China

Caterpillar Marine Asia


Pacific Pte Ltd
No. 5 Tukang
Innovation Grove
Singapore 618304
Republic of Singapore

Phone: +49 40 2380-3000


Telefax: +49 40 2380-3535

Phone: +49 40 2380-3000


Telefax: +49 40 2380-3535

Phone: +1 954 885 3200


Telefax: +1 954 885 3131

Phone: +86 21 6226 2200


Telefax: +86 21 6226 4500

Phone: +65 68287-600


Telefax: +65 68287-625

For more information please visit our website:


MARINE.CAT.COM

Subject to change without notice.


Leaflet No. 219 08.12 e L+S VM3

2012 Caterpillar All Rights Reserved. Printed in Germany. CAT, CATERPILLAR, their
respective logos, ACERT, ADEM, Caterpillar Yellow and the POWER EDGE trade
dress, as well as corporate identity used herein, are trademarks of Caterpillar and
may not be used without permission
TM

Caterpillar Marine Power Systems is committed to sustainability. This document


is printed on PEFC certificated paper.

Você também pode gostar