Você está na página 1de 6

PROYECTO DE RIEGO TECNIFICADO UNSCH

DISEO HIDRAULICO DE PALTO


Gotero (Emisor): "Uralita - Autocompensado" Lateral
LATERAL
IZQUIERDA Pres. Op. Diam. Int. Q. (lit/h) e(m) F Cristiansen Le.(m) L. (m) L.Total N Q (lit/h) J (m/m) hlat. hm
(m) (mm) (m) Emisores Blasius (m) (m)
1 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01
2 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01
3 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01
4 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01
5 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01
6 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01
7 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01
8 10 10.3 1.9 6 0.371 0.1 51.00 56.1 8 15.20 0.0009 0.02 10.01

Gotero (Emisor): "Uralita - Autocompensado" Lateral


LATERAL
DERECHO Pres. Op. Diam. Int. Q. (lit/h) e(m) F Cristiansen Le.(m) L. (m) L.Total N Q (lit/h) J (m/m) hlat. hm
(m) (mm) (m) Emisores Blasius (m) (m)
1 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
2 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
3 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
4 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
5 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
6 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
7 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
8 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02
9 10 10.3 1.9 6 0.371 0.1 56.45 62.095 9 17.10 0.0011 0.02 10.02

TERCIARIA DISTRIBUIDOR O MANIFOLD DE PE - BAJA DENSIDAD 4 atm


Subunidad hm Q. (lit/h) e(m) F Cristiansen L. (m) N Lat. Diam. Int. Diam. Q (lit/h) J (m/m) hman. Q hman
(m) (mm) (") Blasius (m) (lit/se (m)
g)
1 10.01 32.30 1 0.365 55 55 17.6 1 1776.50 0.2789 5.60 0.49 14.21

ARCO DE RIEGO
Subunidad K (Valvula oblicua K (Tee) V (m3/seg) Valvula Tee H.arco (m) Presion requerida
abierta) KV2/2g KV2/2g (m)
1 0.25 1.5 2.03 0.05 0.31 0.37 14.58

LINEA SECUNDARIA

LONGITUD : 54.77m.
EL CAUDAL QUE TRANSPORTA ES = 0,49 LIT/SEG. < Q REQUERIDA OKKK
VELOCIDAD SEGN TABLA PARA CLASE 5 = 0,2 m/seg.

Q=V X A

D = 55,85 mm.
DIAMETRO COMERCIAL = 57 mm. = 2" OKKK

LINEA SECUNDARIA
VALVULA
FILTRO

LINEA
TERCIARI
A

LINEA LATERAL CON EMISOR


DISEO DEL CABEZAL DE RIEGO N 01

Q(lit/seg)= 0.49
Seguridad = 1.2
Qd(lit/seg)= 0.59
m3/h= 2.12

HIDROCICLON: ODIS MODELO: 52060 - 500 mm


Unidades = 1
Perdida carga= 3
Diametro salida y entrada= 6"

FILTRO DE ARENA: MODELO 4400 DE 32"


Caudal (lit/seg)= 17
Unidades = 2
Perdida carga= 3
Diametro salida y entrada= 3"
Total (m) = 6

FILTRO DE MALLA RETROLAVABLE: MODELO 7500 - DIAMETRO 6"


Caudal (lit/seg)= 17
Unidades = 2
Perdida carga= 2.75
Total (m) = 5.5
Diametro salida y entrada= 3"

DOSIFICADOR DE AGUA TIPO GLOBO DE 4": MODELO 900


Unidades = 1
Perdida carga= 2.24

VALVULAS:
DE CONTROL DE 6"
Unidades = 2
Perdida carga= 1
Total (m) = 2

PERDIDA DE CARGA EN EL CABEZAL (m)=18.74


EQUIVALENCIAS DE
Int.
Ext. Int. (") (m) mm
20 mm 1/2" 0.013 12.70
25mm 3/4" 0.019 19.05
32 mm 1" 0.025 25.40
40 mm 1 1/4" 0.032 31.75
50 mm 1 1/2" 0.038 38.10
63 mm 2" 0.051 50.80
75 mm 2 1/2" 0.064 63.50
90 mm 3" 0.076 76.20
110 mm 4" 0.102 101.60
125 mm 5" 0.127 127.00
140 mm 6" 0.152 152.40
DISEO DE LATERALES DE RIEGO POR GOTEO

del lateral (mm) 10.3


Q de transporte(lit/hr) 64
dist. Entre emisores(m) 6
numero de emsiores 16
presion nominal 10.64
hm= 9.98
ha (mca)= 10.64
hn (mca) 9.840

1)calculo de longitud de late 97 m

2) calculo de reynolds Q Q= (lit/seg)


Re 352.64 * d= (mm)
d
Re= 2191.1612
tipo de flujo TRANSICION

3) calculo de perdida de carga unitaria

J 0.473 * d 4.75 * Q 1.75

J= 0.0106
4) calculo de longitud equivalente (Le)-Estndar

Le 18 .91 * d 1.87
Le= 0.2413715

5) calculo de perdida unitaria equivalente


Se Le
J" J * ( )
Se
J"= 0.0110264
6) calculo de factor de cristianzen
1 1 m 1 m = 1.75
F
m 1 2N 6N 2 N = 16

F = 0.39545018

7) calculo de perdida de carga total (Hf)

Hf J " L F
Hf(mcs)= 0.42

8) calculo de presion inicio del lateral (Hm = mca)


d i = -2% -0.02
hm ha 0.733 hf d = -1.94
2
hm= 9.98 mca

9) calculo de presion al final del lateral (hn=mca)


d d 1.57
t / 1 0.357( )
hn hm t / hf hf hf

hn= 9.841 mca t 0.32567

9) tolerancia de caudales
CU = 0.9
CV qns
CU 1 CV = 0.04
e qa
qa = 4 lt/hr
e = 1
qns = 3.75

10) tolerancia de caudales


X = 0.45
q 1.38h 0.45 K = 1.38

con qn hn = 10.64
con qns hns = 9.22

H 2.5 hn hns
H = 3.56

H lateral = 1.78

11) tolerancia de presiones

hm hn Hlateral
0.14 1.78 (OK)
DISEO DE TERCIARIA DE RIEGO POR GOTEO

del lateral (mm) 10.3


Q de transporte(lit/hr) 120
dist. Entre laterales(m) 6
numero de laterales 1
presion nominal 10.64
Hm= 10.9
Ha (mca)= 9.98
Hn (mca) 10.560

1)calculo de longitud de late 44 m

2) calculo de reynolds Q Q= (lit/seg)


Re 352.64 * d= (mm)
d
Re= 4108.4272
tipo de flujo TURBULENTO

3) calculo de perdida de carga unitaria

J 0.473 * d 4.75 * Q 1.75

J= 0.0318
4) calculo de longitud equivalente (Le)-Estndar

Le 18 .91 * d 1.87
Le= 0.2413715

5) calculo de perdida unitaria equivalente


Se Le
J" J * ( )
Se
J"= 0.0330793
6) calculo de factor de cristianzen
1 1 m 1 m = 1.75
F
m 1 2N 6N 2 N = 6

F = 0.45097907

7) calculo de perdida de carga total (Hf)

Hf J " L F
Hf(mcs)= 0.66

8) calculo de presion inicio del lateral (Hm = mca)


d i = -1% -0.01
Hm Ha 0.733 hf d = -0.44
2
Hm= 10.90 mca

9) calculo de presion al final del lateral (hn=mca)


d d 1.57
t / 1 0.357( )
Hn Hm t / hf hf hf

Hn= 10.559 mca t 0.52222

9) tolerancia de caudales
CU = 0.9
CV qns
CU 1 CV = 0.04
e qa
qa = 4 lt/hr
e = 1
qns = 3.75

10) tolerancia de caudales


X = 0.45
q 1.38h 0.45 K = 1.38

con qn hn = 10.64
con qns hns = 9.22

H 2.5 hn hns
H = 3.56

H terciaria= 1.78

11) tolerancia de presiones

Hm Hn Hterciaria
0.34 1.78 (OK)