Bureau of Research,
Testing & Consultation
CoNcnere Laeoneronv
BRTC No. 11 00-88357,i 4-1 S/CE; Dt: 23/61201 5
Client Mr. Md. Tareque Adnan, d.zignscape Consultants Ltd.

Ref. No. Lefter; DL 231612015

Project Radiance Knitwear Ltd. (Building-3), Zirabo, Savar, Dhaka

Sample Goncrete Gylindrical Core IMix Proportion (as quoted): Not Mentioned ]
Year of Construction 2007-2008 No. ofFloors = 3

Sample Collected by Client Date of Sample Collection: 211612015

Test Compressive Strength of Goncrete Gylindrical Gore IASTM C 4ZC 42Ml


Date of Test 28t6t2015

TEST REPORT

NOTE I *
The diameter of core specimens for the determination of compressive strength in load bearing structural members shall be at least 3.70 in. [94 mm]
For nonload bearing structural members or when it is impossible to obtain cores with length-diameter ratio (UD) greater than or equal to 1, core diameters less
than 3.70 in. [94 mm] are not prohibited.

IKIIE 2- Tte wtpressive stengt's of nominal 2-in. [50-mm] diameter cores are known to be somewhat lower and more variable than those of nominal 4-in.
"lffiqmml
fur*r .oiEs in d'0irn. s'naler darng qes ffir
b be more sensitive to the effect of the lenglh{iameter ratio.

COililENT
- Please compare the results with your conesponding design values and consult with your design engineer.

Countersigned by: Ies)Pgformed by:


a\
{6.[r" tt=^h
Dr. Abu Siddique
zr / u7i,
Dr. Rowshan Mamtaz
Professor Professor
Depadment of Civil Engineering Department of Civil Engineering
BUET, Dhaka-1 000, Bangladesh BUET, Dhaka-1 000, Bangladesh

recommended that all test repotts are mllected by duly authorized person, and not by the Contractor/Supplier.

Page I of2
Baxcr-aDEsH f]Nrvnnsrrrr or ENcTNEERTNG AND TncrrNor.ocY (BUET)
Dnpa.RrMENT or Cwrr, EtrcrltnnRrNc
Mobile: 01819 557 964; PABX: 966 5650-80 Ext.7226i www.buet'ac'bd/ce/ BMY,g
Bureau of Research,
Testing & Consultation
Coucnere LaeonA,ronY
BRTC No. 1 I 00-88357,1 4-l 5lGE; Dt: 23161201 5

Client Mr. Md. Tareque Adnan, d.zignscape Consultants Ltd. \


Ref. No. Letter; Dt 231612015 \
Project Radiance Knitwear Ltd. (Building-3), Zirabo, Savar, Dhaka

Sample Goncrete Cylindrical Core IMix Proportion (as quoted): Not Mentioned ]

Year of Construction 2007-2008 No. of Floors = 3

Sample Collected by Client Date of Sample Collection: 211612015

Test Compressive Strength of Goncrete Cylindrical Core IASTM C 4ZC 42MI


Date ofTest 28t612015

TEST REPORT

*
Slab, 2nd Floor, Grid:(C- 4450 psi Combined
I TP-1S-2F 5.2 2.72 5.81 25,834
D) (1-2) (30.7 MPa) (Brick Chips)

*
Slab, 2nd Floor, Grid:(C- 3590 psi Combined
I D) (1-2)
TP.2S-2F 5.1 2.72 5.81 20,840
(24.8 MPa) (Brick Chips)

*
Combined = Mortar and Aggregate failure

NOTE I The diameter of core specimens for the determination of compressive strength in load bearing structural members shall be at least 3.70 in. [94 mm].
-
For nonioad bearing structural members or when it is impossible to obtain cores with lengthdiameter ratio (UD) greater than or equal to 1, core diameters less
than 3.70 in. [94 mm] are not prohibited.

The drpressive sfengths of nominal 2-in. [5Gmm] diarneter cores are known to be somewhat lower and more variable than those of nominal 4-in.
ilOTE 2
-Can* cnes ffiin, sn* ffi 6s b be rue sersitirc to the effed of the lengtMianeter ratio.
;" fi-m.mrrrf, Nn +er

C0tlllEllT
- Please compare the results with your conesponding design values and consult with your design engineer.

Countersigned by: T9s[ Performed by:


tl (,{-,*['u^ I't-Q
--e L/u/r tT
Dr. Abu Siddique Dr. Rowshan Mamtaz "J
Professor Professor
Department of Civil Engineering Department of Civil Engineering
BUET, Dhaka-1 000, Bangladesh BUET, Dhaka-1 000, Bangladesh

recommended that all tesl reports are collected by duly authorized person, and not by the Contractor/Supplier.

Page 2 ol 2