Você está na página 1de 23

K U S T IK +

A
U S T I K+
AK

www.mecanocaucho.com
AMC // AKUSTIK
AKUSTIK&& AKUSTIK+
AKUSTIK+

Contents

Presentation........................................................................... Page.02

Akustik +
Basic information on structural acoustics....................... Page 06
CEILING SUPPORTS
Akustik Range............................................................... Page 08
Gran Akustik Range...................................................... Page 10
Springtec Range............................................................ Page 12
Mountings VT............................................................... Page 14
Mountings Spring Rubber........................................... Page 16
WALL MOUNTS
E.P. Range..................................................................... Page 18
FLOATING FLOOR MOUNTS
Floating floor mounts.................................................... Page 20
Supports blocks............................................................ Page 21
TABIABSORBER........................................................... Page 22

Akustik +

Comparative tests at the Labein technology centre........ Page 24


Behaviour at high and low frequencies.......................... Page 27
Akustik + Sylomer...................................................... Page 28
Gran Akustik + Sylomer............................................. Page 34
SRS + Sylomer............................................................ Page 38
EP + Sylomer Mounts................................................. Page 40
TSR + Sylomer............................................................ Page 44
FHZ + Sylomer Floor Mounts...................................... Page 46

Applications........................................................................... Page 50

1
AMC // AKUSTIK & AKUSTIK+

Factory of AMC-MECANOCAUCHO
ENGINEERING

Factory of in Austria.
LOGISTICS

24h

48h

Akustik+Sylomer is the trademark of a new Bordeaux


72h
Montpelier

solution for the anti-vibration mountings of false ASTEASU

ceilings or vibrating elements that have to be 96h


suspended. They are used for the attenuation of
vibrations, reducing structure-borne noise.
ANTIVIBRATION CALCULATIONS AMC MECANOCAUCHO SERVICE D'ASSISTANCE TECHNIQUE

AMC-MECANOCAUCHO has been Case n A

manufacturing anti-vibration suspensions since 4


0

1969, and since then it has been manufacturing Charges du Systme

suspensions for this same purpose, using rubber, 1 2

spring or a combination of both, called Akustik.


y
Xcdg(m) Ycdg(m) Masse Total
Centre de
gravit Total 0,750 0,5 4300 Kg
x

N Ref. Description k (N/mm) X(m) Y(m) Z(m) F (Kg) s (mm)


1 20476 2 AMC 1500 + Sylomer 835 0 0 0 1075,0 12,63
2 20476 2 AMC 1500 + Sylomer 835 1,5 0 0 1075,0 12,63

GETZNER Werkstoffe GmbH manufactures


3 20476 2 AMC 1500 + Sylomer 835 1,5 1 0 1075,0 12,63
4 20476 2 AMC 1500 + Sylomer 835 0 1 0 1075,0 12,63

a prestigious anti-vibration material called


Sylomer whose main application has been
the isolation of vibrations produced by railways.
Operating from Austria since 1969, it is now the
EXPOSITION TOOLS FOR DISTRIBUTORS
Transmissibility
60

leader in its sector, and boasts totally cutting-


f1 Isolation
Rotation autour OX 0,00000 50 15 89,89%
Rotation autour OY 0,00000 20 94,55%
40
Dflexion cdg 25 96,58%
12,69 mm

edge technological facilities and media for


30 50 99,17%
T

Rapport des flches extrm 100,0%


75 99,63%
Frquence propre 4,55 Hz 20
100 99,79%
N supports 4 10 200 99,95%
Mox 0 Nm

vibration isolation.
0 Attnuation pour les
Moy 0 Nm 1 10 100 diffrents frquences
Frecuency Hz d'excitation

Attnuation pour le ordre n1,0 a 1480 tpm 96,5%


La exactitude de la prsente prconisation dpend des hypothses simplificatrices et des donnes prises en compte par le calcul
Il est recommand de vrifier son adquation au rsultat recherch par toute mesure approprie.
La responsabilit de AMC ne saurait tre engage de quelque manire que ce soit du fait de cette prconisation.

The Akustik+Sylomer ceiling mounts are


made of Sylomer, a microcelular polyurethane
material specially conceived for vibration
isolation. This material produces a higher degree
of damping than the elastomers traditionally
used for this purpose.

2
AMC // AKUSTIK & AKUSTIK+

< The cooperation of two great companies

QUALITY
We posses more than 40 years of experience
providing quality products, capable of overcoming
the most demanding tests. For this purpose it is
vital our knowledge on the correct manufacturing
processes and the use first grade components.

SERVICE
We keep in stock more than 3 Million euros of
finished products. This fact is key to respond
quick to urgent enquiries.

ENGINEERING SERVICES
Calculations Development
Tests Measurements
Our technical department makes calculations,
develops new products, analyzes their elastical
properties and make on site measurements in
order to find the correct technical solution to
solve each vibration problem.

DISTRIBUTOR SUPPORT
AMC-MECANOCAUCHO offers a wide range of
exposition displays on store. Should you require
one, do not hesitate to contact our sales dpt, so
they can offer you the one that adapts better to
your needs.

3
The SUPER security in your installation

Akustik Super
The SUPERsecurity feature is adaptable to the different profiles existing on the market. The external dimension of the profiles that exist
on the market may variate, our SUPER security system with lip form adapts to the different lengths of the profile having a tight fit.

1- The security system is adaptable to different widths of profiles. 2- The SUPER security system admits the possibility of inserting
a blocking screw.

Detail B


Detail A

Installation Steps

Installation of Akustik Super rubber

1 2 3

Installation of Akustik Super +

1 2 3

4
Akustik +
Reliability and cost effectiveness
AMC // AKUSTIK & AKUSTIK+

Akustik +
BASIC KNOWLEDGE ON STRUCTURAL ACOUSTICS
1.-NOISE AND VIBRATION PROBLEMS IN PREMISES
Sound that is unpleasant to the human ear is known as noise,
and ecologically speaking is a form of pollution that is becoming
increasingly more widespread due to town and city development.

It could be defined as a vibratory phenomenon propagated in an


elastic medium (ceilings, walls, floors and the air itself) causing
perturbations in it. To isolate any premises or venue properly, the
first step is to identify the composition and the values of the noise
(spectrum of frequencies, noise level etc.).

Once we know the magnitude of the noise or the vibrations to be


insulated, we must built an unconnected off-the-floor frame which
gives us the insulating and dampening values we need.

2.-THE FUNCTION OF THE ANTIVIBRATION MOUNTS IN


A SOUND-PROOFED PREMISES
All rigid connections of the false structure or frame of the
premises must be installed elastically onto the definitive slabbing. If
any rigid joint is left it will act as acoustic bridge and would annul
the efficacy of the other acoustic elements placed: antivibratory,
absorbents, fibreglass, plasterboard, concrete etc. There are several
elements designed for the insulation of ceilings, walls and floors.
Ceiling mounts Wall Mounts Floor Mounts

3.-ANTIVIBRATION SOLUTIONS

A. RUBBER
Natural frequency between 7 15 Hz
High dampening.
Small static deflections.
Effective in medium and high frequencies.

B. SPRING
Low natural frequency of 3- 6 Hz.
Same static and dynamic behaviour.
Low dampening, excellent insulation.

C. SPRING RUBBER
Natural frequency of 3-15 Hz.
High dampening and insulation.
Effective at all frequencies.

6
AMC // AKUSTIK & AKUSTIK+

Akustik +
BASIC KNOWLEDGE ON STRUCTURAL ACOUSTICS
4.- THE IMPORTANCE OF THE DYNAMIC FREQUENCY
OF THE ANTIVIBRATION MOUNTS.
Real data are required to carry out a study and calculation of
a premises.

The static stiffnesses that are provided by static load-deflection


graphs are not valid for the calculation of a realistic insulation.
Experience shows that the static calculations are very different
from reality.

At the moment, AMC has a dynamic testing machine that can


generate the most common types of vibration on premises,
giving real frequency values, insulation, loss angle and critical
dampening rate.

Dynamic testing machine

5.- INSULATION AND DAMPENING. GOOD INFORMATION BETTER SOLUTION.


Thanks to the testing we have nowadays, it is possible to clear up the role of dampening in a mass-spring insulation.
Elements with high dampening absorb part of the vibration energy that reaches them, so if resonance occurs, they absorb part of this
energy, reducing its negative effects. On the other hand, in the event of resonance, low dampening elements amplify the vibration without
absorbing energy.
Example of isolation and damping of vibrations.

Transmissibility Diagram
100,000

Low dampening
compound

10,000
Amplification

High dampening
Transmissibility (Isolation)

compound

1,000
05 10 15 20 25 30 35 40

Isolation
Resonance point
0,100

0,010
Frecuency of excitation (Hz)

7
AMC // AKUSTIK & AKUSTIK+

Akustik +
CEILING MOUNTS

Akustik ceiling hanger


A-45 Loads from 8 to 30 kg B-60 Loads from 25 to 60 kg
Range designed for suspension of false acoustic ceilings and machinery operating
at more than 1.000 r.p.m. The same vibration damping element which is used
throughout the Akustik range is made of rubber of high mechanical performance;
it is specially designed for vibration damping. The metallic structure is designed to
resist loads up to 650 kg. It its supplied with an anti-corrosive zinc-plated coat.

Dynamic behaviour
Static load deflection graph Natural frequency Hz
60 Shore A

60 Shore A

45 Shore A
Load (Kg)

45 Shore A

Deflection (mm) fo(Hz) Natural frequency

% of isolation and attenuation in dB


To select correct mounting, following data 1
are needed:
Frecuency of excitation

Load per mounting (kg)

Disturbing frequency (Hz) 2

Select correct load line in diagram 1 and refer


to diagram 2 to obtain the Natural frequency.
With this natural frequency prolong this line to
the diagram 3 and obtain the % of isolation at 3
the given frequency of excitation.

fo(Hz) Natural frequency

REF. AMC LOAD CODE REF. AMC LOAD CODE

Akustik Super 8-30 23801 Akustik Super 8-30 23811


T-47 A-45 kg T-60 A-45 kg

Akustik Super 25-60 23802 Akustik Super 25-60 23812


T-47 B-60 kg T-60 B-60 kg

8
AMC // AKUSTIK & AKUSTIK+

Akustik +
CEILING MOUNTS

REF. AMC LOAD CODE SUMMARY REF. AMC LOAD CODE SUMMARY

Fitted Fitted
Akustik 1 8-30 23101 directly Akustik 1 25-60 23102 directly
to ceiling to ceiling
A-45 kg using two B-60 kg using two
holes. holes.

Colocacin Anchoring
Akustik 2 8-30 23111 al techo Akustik 2 25-60 23112 to the
mediante ceiling with
A-45 kg B-60 kg hooks.
ganchos.

Fitted by Fitted by
Akustik 3 8-30 23121 using an Akustik 3 25-60 23122 using an
M-6 rod M-6 rod
A-45 kg and a nut. B-60 kg and a nut.

Fitted to Fitted to
Akustik 4 8-30 23131 ceiling Akustik 4 25-60 23132 ceiling
using an using an
A-45 kg M-6 rod.
B-60 kg M-6 rod.

Fitted to Fitted to
Akustik Rapid 8-30 23143 ceiling Akustik Rapid 25-60 23144 ceiling
using an using an
T-60 A-45 kg T-60 B-60 kg
M-6 rod. M-6 rod.

Designed Designed
for easy and for easy and
accesible accesible
Akustik Rapid 8-30 23145
fitting
Akustik Rapid 25-60 23146
fitting
T-47 A-45 kg together T-47 B-60 kg together
with great with great
strenght. strenght.

The rotational The rotational


system of the system of the
part assures part assures
Akustik Safety 8-30 23210 the correct
Akustik Safety 25-60 23213 the correct
installation installation
T-47 A-45 kg thanks to the T-47 B-60 kg thanks to the
design of the design of the
metal part at metal part at
45. 45.

Steps of the installation for the Akustik Safety


REF. AMC CODE

Levelling 23159
bell
1. Place the part inside the beam. 2. Turn the part inside the beam until 3. The safety system falls by gravity,
it is fixed. embracing the profile automatically.

9
AMC // AKUSTIK & AKUSTIK+

Akustik +
CEILING MOUNTS

Grand Akustik ceiling hanger


A-45 load from 40 to 100 kg B-60 load from 80 to 150 kg

Range designed for suspension of false acoustic ceilings and


machinery operating at more than 1.000 rp.m. The same Dynamic behaviour
antivibration element is used for all the range. This element is
made of rubber offering high mechanical performance and t is Static load deflection graph
specially studied for vibratory insulation. The metallic structure
is designed lo resist loads up to 1000 Kg. It its supplied with an
anticorrosive zinc-plated coat.

Deflection (mm)

Natural frequency Hz

To select correct mounting, following data are needed:

Load per mounting (kg)

Disturbing frequency (Hz)


Load (Kg)

Select correct load line in diagram 1 and refer to diagram 2 to


obtain the Natural frequency. With this natural frequency prolong
this line to the diagram 3 and obtain the % of isolation at the
given frequency of excitation.

1
fo(Hz) Natural frequency

% of isolation and attenuation in dB

2
Frecuency of excitation

fo(Hz) Natural frequency

10
AMC // AKUSTIK & AKUSTIK+

Akustik +
CEILING MOUNTS

REF. AMC LOAD CODE REF. AMC LOAD CODE

Gran 40-100 23201 Gran 80-150 23202

Akustik 1 kg Akustik 1 kg
A-45 B-60

Gran 40-100 23211 Gran 80-150 23212

Akustik 2 kg Akustik 2 kg
A-45 B-60

Gran 40-100 23221 Gran 80-150 23222

Akustik 3 kg Akustik 3 kg
A-45 B-60

Gran Akustik 3 Gran Akustik 2 Example of installation

11
AMC // AKUSTIK & AKUSTIK+

Akustik +
CEILING MOUNTS

Springtec ceiling hanger


Load from 5 to 60 kg.

Range designed for suspensions of false acoustic ceilings and


machinery working at more than 450 r.p.m. Manufactured with Dynamic behaviour
piano tail quality spring of great mechanical resistance guided
by two rubber plates with integral end stops to prevent contact Static load deflection graph

between spirals when overloading.

Deflection (mm)

Natural frequency Hz
Load (Kg)

fo(Hz) Natural frequency

To select correct mounting, following


1
data are needed: % of isolation and attemuation in dB

Load per mounting (kg)

Disturbing frequency (Hz)


Frecuency of excitation

Select correct load line in diagram 1 and


2 refer to diagram 2 to obtain the Natural
frequency. With this natural frequency
prolong this line to the diagram 3 and
obtain the % of isolation at the given
frequency of excitation.

fo(Hz) Frquence propre

12
AMC // AKUSTIK & AKUSTIK+

Akustik +
CEILING MOUNTS

MAX PERMANENT MAX PERMANENT


REF. AMC CODE REF. AMC CODE
LOAD LOAD

Springtec 23301 Springtec ST-10 10 kg


10 kg 23316
ST-10 Type 1 Type 3 T-60

Springtec 23302 Springtec ST-20 20 kg


20 kg 23318
ST-20 Type 1 Type 3 T-60

Springtec 23303 Springtec ST-30 30 kg


30 kg 23320
ST-30 Type 1 Type 3 T-60

Springtec 23304 Springtec ST-60 60 kg


60 kg 23322
ST-60 Type 1 Type 3 T-60

Springtec 23305 Springtec ST-10 10 kg


10 kg 23306
ST-10 Type 2 Type 3 T-47

Springtec 23307 Springtec ST-20 20 kg


20 kg 23308
ST-20 Type 2 Type 3 T-47
28
Springtec 23309 Springtec ST-30 30 kg
30 kg 23310
66

ST-30 Type 2 Type 3 T-47


34,5
44

Springtec 23311 Springtec ST-60 60 kg


60 kg 23312
ST-60 Type 2 Type 3 T-47

Springtec Super 10 kg 23351


T-60 Type ST-10
Springtec Super 20 kg 23352
T-60 Type ST-20

Springtec Super 30 kg 23353


T-60 Type ST-30

Springtec Super
60 kg 23354
T-60 Type ST-60

V Modificacin-Aldarazpena-Modification Real-Egina-Done Fecha-Data-Date


Denominacin Cliente-Bezero-Customer
Izena
Name A3
Material Referencia-erreferentzia-Part Number Ver.
Ekaia
Tratamiento
Tratamendua

Treatment Fichero
File
Escala
Dibuj.-Marraztuta-Drawn Aprob.-Onartua-Approved
Eskala
Schale
Nomb.-Izena-Name
1:1 Fecha-Data-Date

13
AMC // AKUSTIK & AKUSTIK+

Akustik +
Ceiling mounts

VT ceiling hanger
Load from 10 to 750 kg

Range designed for suspension of false acoustic ceilings and machinery incorporase rubber bush concieved lo avoid the acoustic bridges and
operating at more than 450 r.p.m. These isolators are made of the contact of a non aligned screw. The metallic structure is very robust
piano tail spring quaiity with a high mechanical performance. They and it is supplied with an anti-corrosive zinc-plated coat.

Dynamic behaviour

Static load deflection graph Natural frequency Hz

Load (Kg)

Deflection (mm) fo(Hz) Natural frequency

Static load deflection graph Natural frequency Hz


Load (Kg)

Deflection (mm) fo(Hz) Natural frequency

% of isolation and attenuation dB


To select correct mounting, following data 1
are needed:

Load per mounting (kg)


Frecuency of excitation

Disturbing frequency (Hz) 2

Select correct load line in diagram 1 and refer


to diagram 2 to obtain the Natural frequency.
With this natural frequency prolong this line to
the diagram 3 and obtain the % of isolation at
3
the given frequency of excitation.

fo(Hz) Frquence propre


14
AMC // AKUSTIK & AKUSTIK+

Akustik +
Ceiling mounts

REF. AMC
MAX DIMENSIONS CODE
PERMANENT
LOAD A H B C E M

VT 25 25 kg 75 120 30 12 50 M-8 20201

VT 50 50 kg 75 120 30 12 50 M-8 20202

VT 75 75 kg 75 120 30 12 50 M-8 20203

VT 100 100 kg 75 120 30 12 50 M-8 20204

VT 125 125 kg 75 120 30 12 50 M-8 20211

VT 150 150 kg 120 160 30 16 80 M-12 20205

VT 200 200 kg 120 160 30 16 80 M-12 20210

VT 250 250 kg 120 160 30 16 80 M-12 20206

VT 350 350 kg 120 160 30 16 80 M-12 20207

VT 500 500 kg 140 180 30 18 100 M-14 20208

VT 750 750 kg 140 180 30 18 100 M-14 20209

15
AMC // AKUSTIK & AKUSTIK+

Akustik +
Ceiling mounts

Spring Rubber ceiling hanger


Load from 8 to 100 kg.

This is a new range of anti-vibration mounts, combinding the


high deflection of the spring with the dampening properties Dynamic behaviour
of the rubber. The metallic structure is very robust and it is
Static load deflection graph
supplied with an anticorrosive zinc-plated coat.

Deflection (mm)

Natural frequency Hz

To select correct mounting, following data are needed:

Load per mounting (kg)

Disturbing frequency (Hz)


Load (Kg)

Select correct load line in diagram 1 and refer to diagram 2 to


obtain the Natural frequency. With this natural frequency prolong
this line to the diagram 3 and obtain the % of isolation at the
given frequency of excitation.

fo(Hz) Natural frequency

1
% of isolation and attenuation in dB
Frecuency of excitation

fo(Hz) Natural frequency

16
AMC // AKUSTIK & AKUSTIK+

Akustik +
Ceiling mounts

REF. AMC MAX PERMANENT DIMENSIONS CODE


LOAD A H B C E

SRB-25 8-100 kg 75 150 30 12 50 23401

SRB-50 8-100 kg 75 150 30 12 50 23402

SRB-75 8-100 kg 75 150 30 12 50 23403

SRB-100 8-100 kg 75 150 30 12 50 23404

17
AMC // AKUSTIK & AKUSTIK+

Akustik +
CONOCIMIENTOS
WALL MOUNTS SOBRE ACSTICA

EP wall mount
Maximum load per damper 10 kg

The EP wall mounts are manufactured in multiple formats to suit


the different installation techniques. They are specially interesting
for the fixation of walls exceeding 3,5m height. The EP mounts
should be installed 1,5 meters in height. Example: Wall of 4,5
metres, the EP mounts should be installed at 1.5 and 3.

18
AMC // AKUSTIK & AKUSTIK+

Akustik +
WALL MOUNTS

REF. AMC LOAD CODE SUMMARY INSTALLATION

Mount designed for vibration


damping of walls, equipped with
E.P. 100 10 kg 24001 long ring-attached screws for
threading onto wooden or plastified
walls. Maximum load per damper
10 kg.

Mount designed for vibration


damping of walls, equipped with
flanges for fitting onto concrete.
E.P. 200 10 kg 24002
Maximum load per damper 10 kg.

Mount designed for vibration


damping of walls, equipped with
E.P. 300 10 kg 24003 flange and angle for fitting onto
concrete and threaded. Maximum
load per damper 10 kg.

Threaded bolt on
the concrete
This mount is designed to be screwed
to the profile, with the possibility of
E.P. 400 10 kg 24004
choosing different distances thanks Concrete
to its 3 holes.The anchoring in to the
wall is made by 2 fixing flanges. Fixation to the
Threaded bolt on plasterboard
the concrete beam

This damper is conceived to be fixed


between two elements through two
E.P. 600 10 kg 24008
metal parts with pre-drilled holes.
The metal parts are easy to cut in
order to adapt better to each work.

This damper is conceived to be fixed


between two elements through
two metal parts with pre-drilled
E.P. 650 10 kg 24009 holes. The metal parts are easy to
cut in order to adapt better to each
work. Following this idea we can
realise a great amount of variants in
order to adapt better to each work.
Please enquire us if you need a more
adapted system for your work.

19
AMC // AKUSTIK & AKUSTIK+

Akustik +
CONOCIMIENTOS
Floating Floor SOBRE
mountsACSTICA

Floating floor mounts


Load from 50 to 400 kg

A range designed for use in floating floors or machinery working at


more than 700 r.p.m. Manufactured in rubber SMR 5CV type with
excellent mechanical insulation qualities. We are able to manufacture
them in different diameters and heights.

Dynamic behaviour

Static load deflection graph Natural frequency Hz

Load (Kg)

Deflection (mm) fo(Hz) Natural frequency

% of isolation and attenuation in dB


To select correct mounting, following data 1
are needed:

Load per mounting (kg)


Frecuency of excitation

Disturbing frequency (Hz) 2

Select correct load line in diagram 1 and refer


to diagram 2 to obtain the Natural frequency.
With this natural frequency prolong this line to
the diagram 3 and obtain the % of isolation at
3
the given frequency of excitation.

fo(Hz) Natural frequency

REF. AMC MAX PERMANENT LOAD CODE


Height

BF 50 50 kg 40 28 24201

BF 125 125 kg 60 36 24202

BF 200 200 kg 80 40 24203

BF 400 400 kg 95 40 24204

20
AMC // AKUSTIK & AKUSTIK+

Akustik +
CONOCIMIENTOS
FloatingSOBRE
FloorACSTICA
mounts

G Supporting blocks
Load from 300 to 800 kg

A range of rectangular mounts ideal for those instalations that


do not need anchoring or fixation.

Dynamic behaviour

Natural frequency Hz
Static load deflection graph

Load (Kg)

fo(Hz) Natural frequency


Deflection (mm)

% of isolation and attenuation in dB


To select correct mounting, following data 1
are needed:

Load per mounting (kg)


Frecuency of excitation

Disturbing frequency (Hz) 2

Select correct load line in diagram 1 and refer


to diagram 2 to obtain the Natural frequency.
With this natural frequency prolong this line to
the diagram 3 and obtain the % of isolation at
3
the given frequency of excitation.

fo(Hz) Natural frequency

REF. AMC MAX PERMANENT LOAD CODE


A B

G-060 400 kg 70 30 152005

G-070 600 kg 80 30 152006

G-110 800 kg 110 30 152009

G-080 300 kg 80 50 152007

21
AMC // AKUSTIK & AKUSTIK+

Akustik +
TABIABSORBER

Tabiabsorber
Derivery format: 1x1,25 meter layers

EFFECTIVENESS: Manufactured from CR (NEOPRENE) particles


and then compressed, the tabiabsorber can be furnished in two
different versions depending on its use.

VERSATILITY: The TABIABSORBER can be furnished in two


different versions depending on its use.

TABIABSORBER 5: Shock absorber and noise isolator.

TABIABSORBER 10: Vibratory insulation.

We offer the cutting service upon requested dimensions. TABIABSORBER

TABIABSORBER
EASY TO INSTALL: Due to its exterior texture, the adherence to Application: walls and
floating floors
plaster, glue, concrete etc it is easily done thanks to its waterproofing.

Guides

Mortar

TABIABSORBER

Dynamic behaviour
TABIABSORBER 5
Tabiabsorber 5 and 10 TABIABSORBER 10
(Kg./cm2)

6 REF. AMC
)

CODE
2
Carga(Kg/cm
Load

5 30105
Tabiabsorber 5

30110
2 Tabiabsorber 10

0
0,5 11 ,5 2 2,5
Deflection
Flecha(mm)
(mm) The Tabiabsorber can be cutted in bands
TABIABSORBER 5 TABIABSORBER 10 NORMA DIN
CODE 30105 CODE 30110

Thickness 5 mm 10 mm

Density (kg/m3) 820 850

Weight /m2 (kg) 4.1 8.5

Force at traction (N/mm2) 1.05 1.45 53571

Lengthening till rupture(%) 90 108 53571

Waterproofing, k value. (cm/s) 53577


0.6 a 30% of compression 0.8 a 30% of compression

Waterproofing, k value. (cm/s) - 0.03 18035/6

Max. temperature (C)


-40 a 115 -40 a 115

Fire resistance 4102


Class B2 Class B2

22

Você também pode gostar