point when the intelligent memory is empty.

The reference signal for


MPED mechanism
is Pmax which can only be reached when wind speed is sufficiently high.
The intelligent memory
records the system maximum power points and the corresponding
control variables at different
operating conditions. The Direct Current Demand Control (DCDC) utilizes
the optimized relationship
between the Vdc and Idm recorded by the intelligent memory and
generates Idm based
on the present value of Vdc.
Disturbance injection based HCS is proposed by Wang et al. [Wang et al.
2009]. In this control
algorithm, a sinusoidal perturbation signal to the chopper (DC-DC
Voltage Converter) is
injected and then the system output power is sampled at /2 and 3/2
of each cycle, the difference
of an optimum operating point (which results in the oscillation about
the peak power point),
the maximum value of Kt should be below the lowest value of
!(t)
The reference generator speed is not changed if the magnitude of P(k)
is within a small defined

where, Iavg is the average inductor current, f is the switching


frequency, L is inductance and
d1 is the energizing period of an inductor. The equation 2.4 shows that
the average power
to the battery is a second order polynomial which is similar to that of
MPP curve. Hence, by
appropriately selecting the parameters f, L, Vb and d1 according to the
turbine characteristic
makes the battery charging power equal to MPP of the wind turbine [Lo
and Chen 2011]. The
charger is operated in the Continuous Conduction Mode (CCM) if an
input DC voltage(Vin) is
equal to Vb
d1
because of the slow dynamics of the turbine-generator system. The
problem of maximizing the
WG output power using the converter duty cycle as a control variable is
effectively solved using
the steepest ascent method given by the equation 2.5.
dD (D
being dc-dc converter duty cycle) is equal to zero.
Power as a function of the duty cycle has a extremum point which
coincides with MPP of the

where, vds and vqs are the d and q axis stator voltages, ids and iqs are
the d and q axis stator
currents, Rs is the stator resistance and r is the angular speed of the
generator. Ld and Lq are
the stator d and q axis self inductances and r is the rotor flux. Ld, Lq
are given by equation
3.17 and equation 3.18 [Wu et al. 2011].
where, J is the rotational inertia of the generator and Tm is the mechanical torque
for the
generator (in the case of the PMSG connected to a wind turbine, Tm is the torque
from the
turbine).
Using equations from equation 3.13 through to equation 3.20, a PMSG model has
been developed
in matlab/simulink as shown in Figure 3.5. Inputs for the model are d q axis
voltages and
mechanical torque. Rotor speed (r) as calculated through equation 3.20, is a
feedback to the
system. Number of pole pairs, d and q axis inductances, leakage inductance,
magnetic flux of
the rotor magnets, stator resistance and moment of inertia of rotor and load can
be initially set
for a particular size of the generator. As shown in Figure 3.5, d- axis current (ids),
q-axis current
(iqs) and electromagnetic torque (Te) are the outputs from the system as
calculated by equation
3.15, equation 3.16 and equation 3.19 respectively.
implemented with a buck DC-DC converter. The proposed MPPT is based on
directly adjusting
the converter duty cycle according to the result of the comparison of successive
PMSG output
power measurements.