Você está na página 1de 8

CONTACTS

Ural Company for Transformer Technologies (UZTT) Ekaterinburg

Address: 620014 Ekaterinburg, Marshala Zhukova St., 5, 4 floor

Oil-Cooled Power Transformers, Type TM, TMF, TMB, TME


Step-Down Three-Phase Oil-Cooled Power Transformers, Type TM,TMF

The UZTT Company has its own facilities for manufacturing of oil-cooled power transformers, type TMF, TMG,
TMGF, TMZ, and TMB. Oil-cooled power transformers have certificate of conformity No. ROSS
RU.AV28.V00284.

High voltage: 10 kV or 6 kV
Low voltage: 0.4 kV or 0.23 kV
Capacity: 16 kVA, 25 kVA, 40 kVA, 63 kVA, 100 kVA, 160 kVA, 250 kVA, 400 kVA, 630 kVA, 1000 kVA,
1600 kVA, 2500 kVA; step-down transformers with voltage of 10/0.4 kV, 6/0.4 kV, 10/6 kV - step-down
transformers (from 6 kV to 0.4 kV); step-up transformers with voltage of 0.4/10 kV, 0.4/6 kV, 6/10 kV - step-
up transformers.

The UZTT factory manufactures three-phase oil-cooled transformers with capacity of 16 kW, with HV voltage of
10 kV or 6 kV, with LV voltage of 0.4 kV or 0.23 kV; transformers of this family are used in package transformer
substations, type KTP, KTPN, and BKTP and are designed to convert power in networks of electric power
systems and energy consumers as well as to meet requirements of municipal infrastructure, civil construction,
farming facilities and operations as well as other requirements of national economy. Power transformers have
long service life; they are reliable and easy in operation.

Power transformers manufactured by the UZTT Company convert one voltage ac current into another voltage ac
current to provide electrical energy to consumers. Depending on their application, power transformers can be
step-up or step-down transformers.

Three-phase oil-cooled transformers, type


TM, TMF, TMZ, and TMB

Oil-cooled transformers of this family are used for electric


networks with voltage of 6 kV or 10 kV in outdoor electrical
installations in temperate climates (configuration U1 in
compliance with GOST 15150-69) and serve to decrease high
voltage of the supply network to the specified consumer voltage.
TMB-type transformers are used to provide power to electrical
equipment of drilling rigs; TME-type transformers are mounted
on excavator platforms to supply electricity to their equipment;
TMF-type transformers are used for flange mounting.

Voltage is regulated within 22.5 % of its rated value by


changing the tapping on the high voltage side through the five-
step switch with the drive mounted on the transformer lid. Tap
changing is performed in absence of voltage on the transformer.

Range of rated linear voltages


Power transformers are designed for 6 kV or 10 kV rated voltage of the primary winding. The rated voltage of
the secondary winding is 0.4 kV or 0.23 kV. The diagram and connection group of windings is U/Un-0 or D/Un-
11.
In temperate climates, the ambient operating temperature is from + 40 to - 45; in cold climate, the ambient
operating temperature is from +40 to - 60.

The rated capacity range: TM-type transformers - from 25 to 2500 kVA; TMF - from 250 to 1000 kVA; TMZ -
from 400 to 2500 kVA.

Altitude at installation - max 1000 m.


Operating frequency - 50 Hz.
Ensure that the operation of TM-family transformers is not adversely impacted by shaking or vibrations or
chemically aggressive environment. Non-explosive environment free of current-conducting dust;

Tanks of all TM transformers have rectangular form; they are equipped with oil-cooling radiators located along
the tank. The tank walls are made of ribbed 2.5-4 mm thick steel sheeting, thus ensuring reliable operation of
transformers and high shell resistance to deformation during transportation by any types of transport as well as
absence of residual deformations that may be caused by temporary excessive pressures up to 150 kPa (1.5
kgf/cm2) and up to 300 kPa (3 kgf/cm2) without any risk of structural destruction.

Oil-cooled power transformers, type TMF and TMB, are manufactured with the expansion tank:

the internal chamber of transformers has ambient connection. Temperature changes in oil volume that take place
during operation are offset by the expansion tank volume.
To monitor the oil level, transformers are equipped with the oil-level indicator located on the wall of the
expansion tank. The tank is also equipped with the sorbent dehumidifier and oil plug.

To localize consequences of accidents that may be cause by severe internal damage to the transformer, TMF and
TMZ-type 1600kVA+ transformer tanks are equipped with protective pipes with built-in diaphragm valves
intended for emergency discharge of oil in case of sudden increase in excessive pressure exceeding 150 kPa (1.5
kgf/cm2). With normal operation of the TM transformer, these valves do not require any additional maintenance
during entire service life (the projected service life for TMG transformers is 25 years (10,000 cycles per max and
min exposure). To monitor internal pressure in the tank with the relevant warning signal if allowed limits are
exceeded in 1000 kVA+ transformers placed indoors, (at the customer's request) transformers can be equipped
with the electric-contact vacuum pressure gauge.

All transformers can be equipped with standard alcohol or electric-contact manometric thermometers for remote
control over temperature to keep it within the set limits. Transformers can be equipped with electric-contact
vacuum pressure gauges. The manometric signal-producing thermometer can be ordered by the customer to
check temperature of the upper oil layer and control external electric circuits in transformers with capacity of
630 kVA and above.

High voltage and low voltage entrance bushings are placed vertically and are arranged in longitudinally directed
parallel rows on the lid of the transformer tank.
For TMF and TMZ-type transformers, high voltage and low voltage entrance bushings are placed horizontally
and are located on end (short) walls of the tank on its opposite sides. The entrance bushings have boxes, thus
providing flange coupling of transformers with the relevant distribution units. At the customer's request, a
cabinet can be installed on the side of HV entrance bushings in TMF-type transformers. The cabinet design
provides for possibility to install two cable sealing boxes. The cabinet has locks and safety signs. For TMF and
TMZ-type transformers, low voltage entrance bushings can be placed from left to right or from right to left,
depending on the specified instructions of the customer.
Transformers with 160 kVA capacity can be equipped with contact terminal clamps that are mounted on LV
entrance bushings; the clamps can be offered in 2 configurations - either for bus connection or cable connection.

Plates or channel bars with holes to secure the transformer on the foundation platform are welded to the tank
bottom. At the customer's request, for transformers with capacity of 160 kVA and above, channel bars can be
equipped with adjustable rollers that provide for longitudinal or crosswise movement of the transformer. The
downside of the tank has grounding assembly and a drainage plug.

Transformers are transported in completely assembled form and filled up with oil.

Prices for oil-cooled power transformers, rubles:

1 25 / 6/0,4 - -25 / 10/0.4 (0,23), 25/10, 25/6 50 500

2 40 / 6/0.4 - -40 / 10/0,4 (0.23), 40/10, 40/6 58 000

3 63 / 6/0,4 - -63 / 10/0.4 (0,23), 63/10, 63/6 69 000

4 100 / 6/0.4 - -100 / 10/0,4 (0.23), 100/10, 100/6 86 000

5 160 / 6/0,4 - -160 / 10/0.4 (0,23), 160/10, 160/6 111 500

6 250 / 6/0.4 - -250 / 10/0,4 (0.23), 250/10, 250/6 147 000

7 400 / 6/0,4 - -400 / 10/0.4 (0,23), 400/10, 400/6 187 000

8 630 / 6/0.4 - -630 / 10/0,4 (0.23), 630/10, 630/6 276 000

9 1000/6/0,4 - -1000/10/0.4 (0,23), 1000/10, 1000/6 465 500

10 1600/6/0.4 - -1600/10/0,4 (0.23), 1600/10, 1600/6 784 000

11 2500/6/0,4 - -2500/10/0.4 (0,23), 2500/10, 2500/6 1 390 00

Structure of the symbol legend for transformers:

- H /10 U (HL)1:
T - three-phase transformer
M - oil cooling with natural air and oil circulation
H - rated capacity, kVA
10 - HV voltage rating of the winding, kV
U (HL) 1 - climatic configuration and placement category in compliance with GOST 1515069
TMF, where F - flange.

Specifications for TMF transformers:

Rated No-load Short circuit Dimensions, Weight,


W losses
voltage, kV current % voltage,% mm kg
Rated Coil connection
capacity, kW group
No-
HV LV short
load

-25 6; 10 0,4 U/Un-0 120 600 3,2 4,5 800 430 320
970
840 450
-40 160 880 3,0 4,5 430
1075

1045 500
-63 230 1200 2,8 4,5 510
1375

1090 770
-100 320 1970 2,6 4,5 760
1560

1150 820
-160 460 2650 2,4 4,7 985
1580
U/Z-11
1560 930
-250 650 3100 2,3 4,5 1500
1670
D/Un-11
1750 1050
-400 830 5500 2,1 4,5 1890
1780

1930 1180
-630 1050 7600 2 5,5 2105
1910

2080 1290
-1000 1550 10200 1,8 5,5 3450
2150

2175 1290
-1600 2050 16000 1,3 5,5 4500
2430

Specifications:

Types of transformers manufactured by UZTT, kVA capacity, kV voltage; TM, TMF, TMB, TME

16/10 16/6 16 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

25/10 25/6 25 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

40/10 40/6 40 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

63/10 63/6 63 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

100/10 100/6 100 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

160/10 160/6 160 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

250/10 250/6 250 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

400/10 400/6 400 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

630/10 630/6 630 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

1000/10 1000/6 1000 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

1600/10 1600/6 1600 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

2500/10 2500/6 2500 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10


Oil-Cooled Power Transformers, Type TMG, TMGF
Three-phase oil-cooled power transformers, type TMG and TMGF

The UZTT Company for Transformer Technologies has its own facilities for manufacturing of oil-cooled power
transformers and offers transformers of the following types: TMG, TMGF, TM, TMZ, and TMB. Oil-cooled
TMG-type power transformers have certificate of conformity No. ROSS RU.AV28.V00284.

High voltage: 10 kV or 6 kV (6.3 kV).


Low voltage: 0.4 kV or 0.23 kV.
Capacity range: 16 kVA, 25 kVA, 40 kW, 63 kVA, 100 kW, 160 kVA, 250 kW, 400 kVA, 630 kW, 1000 kVA,
1250 kW, 1600 kVA, 2500 kW. Step-down transformer voltage: 10/0.4 kV, 10-0.4 kV, 6/0.4 kV, 10/6 kV; step-up
transformer voltage: 0.4/10 kV 0.4/6 kV, 6/10 kV.

Three-phase oil-cooled TMG/TMGF-type power transformers in hermetically sealed tanks, with 10 kV or 6 kV


high voltage and 0.4 kV or 0.23 kV low voltage are used in package transformer substations (KTPN and BKTP-
type) and are designed to convert electrical energy in electric power networks and for electrical energy
consumers. They have long service life; they are reliable and easy in operation. The projected service life for
TMG TM transformers is 25 years (10,000 cycles per max and min pressure exposure).

Oil-cooled power transformers, type TMG/TMGF:

TMG-type transformers manufactured by UZTT Company convert alternating current of one voltage into
alternating current of another voltage required for power supply of consumers. Depending on application, power
transformers can be step-up or step-down transformers.

Oil-cooled TMG transformers operate in 6 kV or 10 kV electric networks in


outdoor installations in temperate climates (configuration U1 in compliance with
GOST 15150-69) and are used to decrease high voltage of the supply network to
the specified consumer voltage.
Voltage is regulated within 22.5 % of its rated value by changing the tapping on
the high voltage side through the five-step switch with the drive mounted on the
transformer lid. Tap changing is performed in absence of voltage on the
transformer.
The range of rated linear voltages for oil-cooled TMG transformers: 6/0.4 (TMG 6.3/0.4); TMG 10/0.4 kV or
TMG 6/0.23 (TMG 6.3/0.23); TMG 10/0.23 kV;
The ambient temperature ranges from + 40 to - 45 in temperate or cold - from +40 to - 60 - climates.
Rated capacity range: TMG transformers - from 25 kVA to 2500 KVA; TMGF transformers - from 250 to 1000
kVA; TMZ transformers - from 400 to 2500 kVA.
TMG power transformers are designed for the primary winding rated voltage of 6 or 10 kV.
The rated voltage for the secondary winding is 0.4 kV or 0.23 kV.
The diagram and connection group of windings is U/Un-0 or D/Un-11.
The altitude at installation - max 1000 m.
Operating frequency: 50 Hz.

Ensure that the operation of TMG-family transformers is not adversely impacted by shaking or vibrations or
chemically aggressive environment. Non-explosive environment free of current-conducting dust.

Tanks of all oil-cooled TMG power transformers have rectangular form; they are equipped with oil-cooling
radiators located along the tank. The tank walls are made of ribbed 2.5-4 mm thick steel sheeting, thus ensuring
reliable operation of transformers and high shell resistance to deformation during transportation by any types of
transport as well as absence of residual deformations that may be caused by temporary excessive pressures up to
150 kPa (1.5 kgf/cm2) and up to 300 kPa (3 kgf/cm2) without any risk of structural destruction.
Oil-cooled TMG, TMGF, TMZ and TMB power transformers are offered in hermetically sealed configuration;
their internal chamber has no outside exposure, and pressure changes inside the tank are offset by air "cushion"
in the upper part of the tank. To prevent prohibitive overpressure, the TMG transformer is equipped with a
pressure relief valve that is actuated at the excessive pressure of 75 kPa (0.75 kgf/cm 2). The operating manual for
the TMG power transformer requires that the excessive pressure inside the tank must not exceed 50 kPa (0.5
kgf/cm2). The insulation of the inner chamber of the transformer tank improves significantly oil operating
conditions, preventing its humidification, oxidation and sludge formation. To monitor the oil level, TMG, TMGF,
TMZ and TMB transformers are equipped with the oil-level indicator located on the wall of the tank. Even after
extended storage, TMG transformers require virtually no expenses on pre-commissioning, and if operated
properly, can operate for a long time without repair works that may require opening of the tank.

To localize consequences of accidents that may be cause by severe internal damage to the transformer, 400 kVA+
transformer tanks are equipped with protective pipes with built-in diaphragm valves intended for emergency
discharge of oil in case of sudden increase in excessive pressure exceeding 150 kPa (1.5 kgf/cm 2). With normal
operation of the TMG transformer, these valves do not require any additional maintenance during entire service
life. To prevent excessive pressure, the tank of the transformer with 25 to 250 kVA capacity is equipped with a
safety valve. To monitor internal pressure in the tank with the relevant warning signal if allowed limits are
exceeded in 100 kVA+ transformers placed indoors, (at the customer's request) transformers can be equipped
with the electric-contact vacuum pressure gauge.

Tanks can be equipped with floating gauges to monitor the limit (lower) level of oil. All TMG-type transformers
can be equipped with standard alcohol or electric-contact manometric thermometers for remote control over
temperature to keep it within the set limits. Transformers can be equipped with electric-contact vacuum pressure
gauges. The manometric signal-producing thermometer can be ordered by the customer to check temperature of
the upper oil layer and control external electric circuits in TM-type transformers with capacity of 630 kVA and
above.

High voltage and low voltage entrance bushings are placed vertically and are arranged in longitudinally directed
parallel rows on the lid of the transformer tank for TMG and TMB transformers.

For TMGF and TMZ-type transformers, high voltage and low voltage entrance bushings are placed horizontally
and are located on end (short) walls of the tank on its opposite sides. The entrance bushings have boxes, thus
providing flange coupling of transformers with the relevant distribution units. At the customer's request, a
cabinet can be installed on the side of HV entrance bushings in transformers. The cabinet design provides for
possibility to install two cable sealing boxes. The cabinet has locks and safety signs. Low voltage entrance
bushings can be placed from left to right or from right to left, depending on the specified instructions of the
customer.

TMG-type transformers with 160 kVA capacity can be equipped with contact terminal clamps that are mounted
on LV entrance bushings; the clamps can be offered in 2 configurations - either for bus connection or cable
connection.

To make equipment easy to move, transformers with 160 kVA and above capacity (at the customer's request) are
equipped with rollers.

Prices for TMG power transformers, rubles:

1 TMG-25 (TMGF) TMG 25 / 6/0,4 - TMG 25 / 10/0.4 50 500

2 TMG-40 (TMGF) TMG 40 / 6/0.4 - TMG 40 / 10/0,4 58 000

3 TMG-63 (TMGF) TMG 63 / 6/0,4 - TMG 63 / 10/0.4 69 000


4 TMG-100 (TMGF) TMG 100 / 6/0,4 - TMG 100 / 10/0.4 86 000

5 TMG-160 (TMGF) TMG 160 / 6/0,4 - TMG 160 / 10/0.4 111 500

6 TMG-250 (TMGF) TMG 250 / 6/0,4 - TMG 250 / 10/0.4 147 000

7 TMG-400 (TMGF) TMG 400 / 6/0.4 - TMG 400 / 10/0,4 187 000

8 TMG-630 (TMGF) TMG 630 / 6/0,4 - TMG 630 / 10/0.4 276 000

9 TMG-1000 (TMGF) TMG 1000 / 6/0,4 - TMG 1000 / 10/0.4 465 500

10 TMG-1600 (TMGF) TMG 1600 / 6/0,4 - TMG 1600 / 10/0.4 784 000

11 TMG-2500 (TMGF) TMG 2500/6/0,4 - TMG 2500 / 10/0.4 1390000

12 TMG-4000 (TMGF) TMG 4000 / 6/0,4 - TMG 4000 / 10/0.4 1700000

Structure of the symbol legend for TMG-type transformers:

TMG - H /10 U (HL) 1:


- three-phase transformer
- oil cooling with natural air and oil circulation
G - hermetically sealed tank, no oil contact with ambient air
H - rated capacity, kVA
10 - HV voltage rating of the winding, kV
U (HL)1 - climatic configuration and placement category in compliance with GOST 1515069

TMGF, where F - flange

Specifications for oil-cooled double-winding transformers, TMG-type:

Transformers are offered in hermetically sealed configuration; their internal chamber has no connection with
ambient air. Transformers are filled up with transformer oil. Tanks are equipped with a floating gauge to monitor
oil level; the gauge is located on the lid.

Plates or channel bars with holes to secure the transformer on the foundation platform are welded to the tank
bottom. At the customer's request, for transformers with capacity of 160 kVA and above, channel bars can be
equipped with adjustable rollers that provide for longitudinal or crosswise movement of the transformer. The
downside of the tank has grounding assembly and a drainage plug.

TMG transformers are transported in completely assembled form and filled up with oil.

No-load Short
Rated Weight,
Losses, W current, circuit Dimensions, mm
Rated voltage, kV Coil kg
% voltage,%
capacity, connection
kW group
No-
HV LV Short
load

TMG-25 6 kV; 0.23 kV U/Un-0 130 630 3,2 4,5 780650850 290
kVA
TMG-40
160 900 3,0 4,5 780760920 350
kVA

TMG-63
210 1300 2,8 4,5 780760990 410
kVA

TMG-100
290 1970 2,6 4,5 11008701640 790
kVA

TMG-160
440 2650 2,4 4,7 12509201680 990
kVA
10 kV 0.4 kV U/Z-11
TMG-250
550 3100 2,3 4,5 14209901740 1300
kVA

TMG-400
800 5500 2,1 4,5 165010801780 1650
kVA

TMG-630
1050 7600 2 5,5 182011501910 1950
kVA

TMG-1000
1550 10200 2 5,5 200012502100 2890
kVA

Specification:

Types of TMG transformers manufactured by UZTT; kVA capacity; kV voltage; TMG and TMGF types

TMG 16/10 TMG 16/6 16 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 25/10 TMG 25/6 25 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 40/10 TMG 40/6 40 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 63/10 TMG 63/6 63 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 100/10 TMG 100/6 100 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 160/10 TMG 160/6 160 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 250/10 TMG 250/6 250 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 400/10 TMG 400/6 400 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 630/10 TMG 630/6 630 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 1000/10 TMG 1000/6 1000 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 1600/10 TMG 1600/6 1600 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

TMG 2500/10 TMG 2500/6 2500 10/0,4; 6/0,4; 10/0,23; 6/0,23; 10/6; 6/10

Você também pode gostar