Escolar Documentos
Profissional Documentos
Cultura Documentos
Full Output
Note: Section Designed to Eurocodes, United Kingdom National Annex
Construction Stage: PASS Max Unity Factor: 0.59
Normal Stage: PASS Max Unity Factor: 0.21
Fire Condition: PASS Max Unity Factor: 0.27
Serviceability: SATISFACTORY Max Unity Factor: 0.70
*** Section Adequate ***
WARNING: High Concentrated Loads
The requirements of EN1994-1-1 clause 9.4.3 (5) are exceeded for the following loads:
Perpendicular loads: 2
Parallel loads: 2
Recommended minimum transverse reinforcement is 335.60 mm.
Floor Plan Data (unpropped composite construction with ComFlor 80/1.2/S350 decking)
Beam centres 3.00 m Profile span type Single
Beam or wall width 152 mm Propping None
Concrete span type End
Profile Data (ComFlor 80/1.2/S350 decking. Grade C30/37)
Depth 80 mm Pitch of deck ribs 300 mm
Trough width 120 mm Crest width 150.0 mm
Nominal sheet thickness 1.20 mm Design sheet thickness 1.16 mm
Deck weight 0.15 kN/m Yield strength 350 N/mm
Concrete Slab (Normal Weight Concrete ; Mesh : A393)
Overall slab depth 250 mm
Concrete characteristic strength 30 N/mm Concrete wet density 2550 kg/m
Modular ratio 10 Concrete dry density 2450 kg/m
Bar reinforcement None
Mesh reinforcement :
Mesh A393 Yield strength 500 N/mm
Cover to Mesh 30 mm Mesh Layers Single
Account for End Anchorage No Shear connectors per rib N/A
Diameter of Shear Connectors N/A
Screeds N/A
Section Properties
*** Note - 1: All values of inertia are expressed in steel units
*** Note - 2: Average inertia is used for deflection calculations for the composite stage
*** Note - 3: Cracked dynamic inertia is used for natural frequency calculations
Deck Profile
Sagging Inertia, Iy 213.000 cm4/m Area of profile (Net), Ap 1864 mm/m
Hogging Inertia, Iy 203.000 cm4/m Effective area of profile 1678.00 mm/m
Composite
Inertia, Iy - Uncracked 10686 cm4/m Inertia, Iy - Cracked 4752 cm4/m
Average inertia 7719 cm4/m Cracked inertia (dynamic) 5262 cm4/m
Shear bond coefficients - Tau 0.21
Concrete volume 0.205 m/m/m
Loads Acting on Slab (Actions)
*** Note: Slab subjected to ( 2 ) additional line load(s) perpendicular to deck span
*** Note: Slab subjected to ( 2 ) additional line load(s) parallel to deck span
Imposed (occupancy) 0.00 kN/m Partitions 1.00 kN/m
Ceilings and services 0.50 kN/m Finishes 0.50 kN/m
Self weight of concrete slab (wet) 5.13 kN/m Self weight of decking 0.15 kN/m
Self weight of concrete slab (dry) 4.93 kN/m Screeds None
Construction load 1.50 kN/m
Line Loads Perpendicular to Deck Span (Actions)
Load Load Load tf (mm) Location (mm) Load
No Value (kN/m) width (mm) (see Note 1) (see Note 2) Type
1 32.0 0 0.0 0 Superdead
2 12.0 0 0.0 0 Live
Line Loads Parallel to Deck Span (Actions)
Load Load Load tf (mm) Load Start (mm) Load End (mm) Load
No Value (kN/m) width (mm) (see Note 1) (see Note 2) (see Note 2) Type
1 32.0 0 0.0 0 0 Superdead
2 12.0 0 0.0 0 0 Live
*** Note 1: tf, thickness of joint-free durable finishes at location of loading (see BS 5950 : Part 4 : cl. 6.7)
*** Note 2: All distance measurements from Left Hand Support
Fire Data
Design method Mesh + Deck Method Fire resistance period 120 mins
Non-permanent imposed loads N/A
Partial Safety Factors
Actions Materials
Permanent, gamma G 1.35 Structural steel - elastic, gamma M0 1.00
Permanent - accidental, gamma GA N/A Structural steel - buckling, gamma M1 1.00
Variable, gamma Q 1.50 Concrete, gamma C 1.50
Combination factor - Fire, psi 1 0.70 Reinforcement, gamma S 1.15
Combination factor, psi 0 0.70 Combination factor, psi 2 0.60
Construction Stage
Normal Stage
Span
The effective composite span is 3.00 m
Loadings @ SLS (kN/m) @ ULS (kN/m)
Dead (Profile, concrete, reinforcement) 5.15 6.95
Imposed 1.00 1.50
Superimp (Ceiling, services, screed, finishes) 1.00 1.35
Total 7.15 9.80
All line and point described above in 'Loading Details' are applied at the Normal stage
Shear Resistance Check
Vertical Shear (BS EN 1992-1-1 Clause 6.2.2)
Maximum applied shear 14.03 kN/m
Shear resistance of end diaphragm (ComFlor 225 only) 0.00 kN/m ***test value
Vertical shear resistance is the greater of:
1. (0.54 * 400.00 * 204.99) / 1000 + 0.00
2. (0.12 * 1.99 * (100 * 0.02 * 30.00)^1/3) * 400.00 * 204.99) / 1000 + 0.00
= 76.57 kN/m
Unity Factor = 14.03/76.57 = 0.18 < 1 PASS
Punching Shear (BS EN 1994-1-1 Clause 9.7.6)
Critical load for punching shear 1 and 2
At the critical concentrated load:
Area of perimeter of concentrated load 340000.00 mm
Area of control perimeter 545377.30 mm
Punching shear resistance 5.28 N/mm
Punching load 61.20 kN
Applied punching shear resistance 295.71 kN
Unity Factor 0.21 PASS
Bending Resistance Check (BS EN 1994-1-1 Clause 9.7.2)
Applied bending moment 9.68 kNm/m
Depth of concrete stress block 12.79 mm
Lever arm 195.10 mm
Compression in concrete 217.35 kN/m
Moment Resistance 56.96 kNm/m
Unity Factor = 9.68/56.96 = 0.17 < 1 PASS
Fire Resistance