Você está na página 1de 21

346424145.

xls

Yield strength - 25000 PSI FOR PLATE 1 PSI = 6895.0741 Pa


Tensile strength - 70000 PSI MATERIAL * Pa = N / M^2
Yield strength 172.38 MPa UNS NO. S30403 1 KG / MM^2 = 9.81 MPa
Tensile strength 482.66 MPa

MPa KG/MM^2 KG/CM^2


Sd = Allowable design stress in MPa = 114.92 11.71 1171.44
Less of 2/3 of the yield strength OR 2/5 of tensile strength
2/3 of Yield strength = 114.918
2/5 of Tensile strength = 193.062
St = Allowable hydrostatic stress in MPa = 129.2826 13.18 1317.87
Less of 3/4 of the yield strength OR 3/7 of tensile strength
3/4 of Yield strength = 129.283
3/7 of Tensile strength = 206.852

1.033 kg/cm^2 = 1 atm = 10330 kg/m^2

Design shell thickness in mm :


td = 4.9 D G ( H - 0.3 ) + C if S is in N / MM2
Sd E
OR
td = 50 D G ( H - 0.3 ) + C if S is in Kgf / CM2
Sd E

Hydrostatic test shell thickness in mm :


tt = 4.9 D G ( H - 0.3 ) OR 50 D G ( H - 0.3 )
Sd E Sd E

where,
D= inside diameter of tank in meters
H= Design liquid level
G= Design specific gravity of liquid
C= Corrosion allowance in MM
Sd = Allowable design stress in MPa
St = Allowable hydrostatic stress in MPa
E= Joint efficiency

BASIC
SCHEME NO.: PROJECT TITLE :
STORAGE TANK DESIGN

DESIGN CODE API 650, 10TH EDITION, NOVEMBER 1998


IS 803 - 1976, FIRST REVISION, THIRD REPRINT OCTOBER 1986

ITEM NO. MFB-501


TYPE OF TANK FIXED ROOF TANK
SERVICE METHANOL
NOMINAL CAPACITY M^3
INSIDE DIAMETER 8500 MM
HEIGHT (LIQUID LEVEL) 9250 MM
HEIGHT (MECHANICAL) 9250 MM
ROOF TYPE FIXED ROOF TANK
ROOF ANGLE 10
CORROSION ALLOWANCE 1.6 MM
DESIGN SPECIFIC GRAVITY 0.83
DESIGN LIQUID DENSITY 830 KG / M^3
DESIGN PRESSURE ATM MM WC (+ATM + FULL OF WATER)
-50 MM WC
DESIGN TEMP., MAX. 65 C
DESIGN TEMP., MIN. 5 C
WIND VELOCITY 44.5 M / Sec. IS 875
WIND FORCE, P 158.4 KGF / M^2
WIND SHAPE FACTOR 0.7
SEISMIC FACTOR IS 1893
DESIGN RAINFALL 65 MM PER HOUR
MAX. LIQUID LEVEL 9250
FILLING RATE 35 M^3 / HR.
PLATES / ROOF STRUCTURE IS 226
PIPES
FLANGES
JOINT EFFICIENCY FACTOR 0.85
Yield strength 32713 PSI
Tensile strength 59737 PSI
Yield strength 225.56 MPa
Tensile strength 411.89 MPa

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)
* = Page - 82, Section II D

346424145.xls DATA
Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
SHELL

DESIGN OF SHELL BASED ON API - 650 (PARA. 3.6.3)


3.6.3 : Calculation of Thickness by the 1-Foot Method
Formula in calculating the minimum thickness of shell plates
Design shell thickness in mm :
td = 4.9 D ( H - 0.3 ) G + C if S is in N / MM2 or MPa)
Sd E
OR
td = 50 D ( H - 0.3 ) G + C if S is in Kgf / CM2)
Sd E

Hydrostatic test shell thickness in mm :


tt = 4.9 D G ( H - 0.3 ) OR 50 D G ( H - 0.3 )
St E St E
where,
D= inside diameter of tank in meters = 8.5 M
H= Design liquid level
G= Design specific gravity of liquid = 0.83 1
Min. specific gravity of liquid to consider = 1
C= Corrosion allowance in MM = 1
Sd = Allowable design stress in MPa = 145.00
Less of 2/3 of the yield strength OR 2/5 of tensile strength
2/3 of Yield strength = 150.3724 MPa
2/5 of Tensile strength = 164.7564 MPa
Min. stress value as per API650, Clause 3.6.2.3 (Pg. 3-7) 145 MPa

St = Allowable hydrostatic stress in MPa = 169.1689


Less of 3/4 of the yield strength OR 3/7 of tensile strength
3/4 of Yield strength = 169.1689 MPa
3/7 of Tensile strength = 176.5247 MPa
Min. stress value as per API650, Clause 3.6.2.3 (Pg. 3-7) 171 MPa

CALCULATION AND RESULTS:


SHELL COURSE HEIGHT H - 0.3 td td tt THK. REMARKS
COURSE WIDTH H (WITH OUT CA) (WITH CA) (WITH OUT CA) PROVIDED
NOS. M M M MM MM MM MM
1 1.5 9.25 8.9500 3.0245 4.0245 2.5924 5 SEE PARA 3.6.1.1
2 1.4 7.75 7.4500 2.5176 3.5176 2.1579 5 SEE PARA 3.6.1.1
3 1.4 6.35 6.0500 2.0445 3.0445 1.7524 5 SEE PARA 3.6.1.1
4 1.4 4.95 4.6500 1.5714 2.5714 1.3469 5 SEE PARA 3.6.1.1
5 1.4 3.55 3.2500 1.0983 2.0983 0.9414 5 SEE PARA 3.6.1.1
6 1.4 2.15 1.8500 0.6252 1.6252 0.5359 5 SEE PARA 3.6.1.1
7 0.75 0.75 0.4500 0.1521 1.1521 0.1303 5 SEE PARA 3.6.1.1
PARA. 3.6.1.1 :
The required shell thickness shall be the greater of the design shell thickness, including
any corrosion allowance, or the hydrostatic test shell thickness, but the shall thickness
shall not be less than the following :
Nominal Tank Diameter (M) Nominal Plate Thickness (MM) of shell
< 15 5
15 < 36 6
36 < 60 8
> 60 10
DATE DESIGN BY : CHK. BY :
20-Apr-05

346424145.xls SHELL
Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
BOTTOM
0 0

DESIGN OF BOTTOM PLATE BASED ON API - 650 (PARA. 3.5.2)

All bottom plates shall have a minimum nominal thickness of 6 MM (70 kPa)
exclusive of any corrosion allowance. All rectangular and sketch (bottom) plates
shall have a minimum nominal width of 1800 MM

Annular bottom plates shall have a radial width that provides at least 600 MM
between the inside of the shell and any lap-welded joint in the reminder of the
bottom and atleast 50 mm projection outside the shell. A greater radial width
of annular plate is required when calculated as follows:

Annular width wa = 215 tb


( H G ) 0.5

where,
tb = thickness of the annular plate = 6 MM
H= Max. design liquid level = 9.25 M
G= Design specific gravity of liquid = 0.83

Hence, annular width wa = 465.564 MM < 600 MM

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls BOTTOM
Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
ROOF
0 0

DESIGN OF ROOF BASED ON API - 650 (PARA. 3.10.2)


All roofs and supporting structures shall be designed to support dead load plus a uniform
live load of not less than 1.2 kPa or 25 PSI of projected area.

Roof plates shall have a minimum nominal thickness of 5 mm 7-gauge sheet.Thicker roofs
may be required for self-supporting roofs. Any required corrosion allowance for the plates
of self-supporting roof shall be added to the calculated thickness unless otherwise
specified by the purchaser. Any corrosion allowance for the plates of supported roofs shall
be added to the minimum nominal thickness.

All internal and external structural members shall have a minimum nominal thickness of
4.3 MM in any component. The method of providing a corrosion allowance, if any, for the
structural members shall be a matter of agreement between the purchaser and the
manufacturer.

Self Supporting Cone Roofs : (Para 3.10.5)


Self-supporting roofs whose roof plates are stiffened by sections welded to the plates
need not confirm to the min. thickness requirements, but the thickness ofthe roof plates
shall not be less than 5 MM when so designed by manufacturer, subject to the approval of
the purchaser.

Self supporting cone roofs shall confirm to the following requirements :


< 37 (slope = 9 : 12)
> 9.5 (slope = 2 : 12)

Minimum thickness tr = D > 5 MM


4.8 sin

Max. thickness (exclusive of corrosion allowance) = 13 MM


where,
Angle of cone elements to the horizontal = 10
D= Nominal diameter of the tank shell = 8.5 M
tr = Minimum thickness of tank roof = 10.20 MM

When the sum of the live and dead loads exceed 2.2 KPa, the min. thickness shall be
increased by following ratio:
live load + dead load
2.2 KPa
Considering live load = 1.22 KPa 122 KG / CM^2
dead load = 0.4 KPa 40.25 KG / CM^2
1.62 KPa
Ratio = 0.86
Min. thk. = 11.06
Min. thk. to be provided = 5 MM

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls ROOF
Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
WIND STABILITY
0 0

STABILITY OF SHELL AGAINST WIND AS PER PARA 3.9.7

Allowable height of unstiffened shell :

Hallow = 6 x 1.2 x t [1.2 t ]3 x [44.7 ]2


D3 V2

where,
D= inside diameter of tank in meters = 8.5 M
t= shell plate thickness, average
V= Wind velocity = 44.5 M / SEC.

S. SHELL COURSE UNDER THK. THK. Hallow H REMARKS


NO. CONSIDERATION FROM TOP AVG.
MM M M

1 1, 2, 3, 4 5 5 22 5 OK

DATE DESIGN BY : CHK. BY :

346424145.xls WIND STABILITY


20-Apr-05 M (PJK) SM(RJH)

346424145.xls WIND STABILITY


Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
WIND STABILITY
0 0

STABILITY OF SHELL AGAINST WIND AS PER PARA 3.9.7

Para. 3.9.7 of API 650 (Intermediate Wind Girders)

The maximum height of unstiffened shell shall be calculated as follows:

H1 = 9.47 t t3 OR 1500 t t3
D3 P D3

where,
H1 = Vertical distance, in M, between the intermediate wind girder and the top
angle of the shell or the top wind girder of an open-top tank
D= Nominal tank diameter, MM = 8.5 M
t= As ordered thickness, of the top shell course = 5 MM
P= Wind force = 158.4 KGF / M2

9.47 = 1500 / P = 1500 / 158.4

H1 = 9.47 x 5 x (5)3
(3205)3

H1 = 21.3622 M < 8.5 M

Hence, no wind girders / stiffening ring is required.

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls WIND STABILITY-1


Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
0
CURB ANGLE 0

DESIGN OF SHELL CURB ANGLE BASED ON IS-803 (PARA. 6.3.6)

The minimum sizes of top curb angle shalll be :


a) Tanks upto and including 10 M diameter = 65 x 65 x 6 thk.
b) Tanks over 10 M and upto & including 18 M diameter = 65 x 65 x 8 thk.
c) Tanks over 18 M and upto & including 36 M diameter = 75 x 75 x 10 thk.
d) Tanks over 36 M = 100 x 100 x 10 thk.

Note: Thickness specified above includes corrosion allowance required for


petroleum service. Special consideration should be given for severe
service.

PARA 6.4.5.1 (Page-38) For self supporting cone roofs

The cross-sectional area of the top angle in CM^2 plus the cross-sectional area of
the shell and roof plates within a distance of 16 times their thickness measured
from their most remote point of attachment to the top angle, shall not be less than:

D2
40 sin
where,
D= Nominal diameter of the tank shell = 8.5 M
= Angle of the cone elements with the horizon = 10
t= Nominal thickness of the roof plates = 5 MM

D2 = 72.25 = 10.402 CM2


40 sin 6.94592711

Curb angle provided = 65 x 65 x 6 thk.


Cross-sectional area of curb angle = 7.44 CM2

Thus, c/s area of provided curb angle is greater than required c/s area as per
para 6.4.5.1

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls CURB ANGLE


Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
SEISMIC DESIGN
0 0
SEISMIC DESIGN AS PER API-650, APPENDIX-E
E.3.1. OVER- TURNING MOMENT
MARK DESCRIPTION FORMULA VALUE UNIT
Z Seismic zone factor (based on Zone-3 of India) From Table E-2 1
I Essential facilities factor (Importance factor) 1 -
S Site amplication factor (Site coefficient) From Table E-3 1.5 -
C1 Laterial earthquake force coefficient 0.04 -
D Tank diameter 8500 MM
H Max. filling height (Design liquid ht.) 9250 MM
D/H Ratio D/H 0.9189189189
k Factor from Fig. E-4 for the ration D/H From Fig. E-4 0.58
T Natural period of first sloshing mode T = k D0.5 53.47 Sec
C2 Laterial earthquake force coefficient
When T < 4.5 C2 = 0.75 S / T
0.0018
When T > 4.5 C2 = 3.375 S / T2
WT Total weight of tank content 435660.89 Kgs
WS Total weight of tank shell 16884.56 Kgs
XS Height from bottom of tank shell to centre of
4625 MM
gravity of shell
Wr Total weight of tank roof 2467.13 Kgs
HT Total height of tank shell 9250 MM
W1 / WT Ratio to be taken from E-2 against D/H ratio From Fig. E-2 0.85 -
W1 Weight of effective mass of tank contents
= ( W1 / WT ) WT 370311.76 Kgs
which moves in unision with tank shell
W2 / WT Ratio to be taken from E-2 against D/H ratio From Fig. E-2 0.18
W2 Weight of effective mass of first mode
= ( W2 / WT ) WT 78418.96 Kgs
sloshing contents of tank
X1 / H Ratio obtained from Fig. E-3 by D/H ratio From Fig. E-3 0.45 -
X1 Height from bottom of tank shell to centroid
= ( X1 / H ) H 4162.5 MM
of lateral seismic force applied to W 1
X2 / H Ratio obtained from Fig. E-3 by D/H ratio From Fig. E-3 0.8 -
X2 Height from bottom of tank shell to centroid
( X2 / H ) H 7400 MM
of lateral seismic force applied to W 2

M = Over-turning moment applied to bottom of tank shell 66720795.408 Kg-MM


M = Z I ( C1 Ws Xs + C1 Wr Ht + C1 W1 X1 + C2 W2 X2 ) 66720.80 Kg-M

PARA E.4 REISITANCE TO OVERTURNING


Resistance to overturning moment at the bottom of the shell may be provided by the weight of the
tank shell and by the anchorage of the tank shell or, for unanchored tanks, the weight of a portion of
the tank contents adjacent to the shell. For unanchored tanks, the portion of the contents that
may be used to resist overturning depends on the width of the bottom plate under the shell that
lifts off the foundation and may be determined as follows :

wL = 99 tb Fby G H However, wL shall not exceed 196GHD


where,
tb = Thickness of annular plate / bottom plate under the shell 6 MM
ts = Thickness of bottom shell course 5 INCH
Fby = Min. specified yield stress of the bottom plate under the shell 225.56 MPa
22.99 Kg/MM^2
G = Design specific gravity 0.83 -
H = Max. design liquid level 9250 MM
D = Nominal tank diameter 8500 MM
wL = Max. weight of tank contents of shell that may be used to resist the Kg/M
shell overturning moment of shell circumference

Therefore, wL = 99 x 6 22.99 0.83 9.25 = 7892.08 Kg/M

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls SEISMIC
Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
WIND LOAD
0 0

DESIGN OF WIND LOAD AS PER

Fw = D x H x Shape factor x Wind pressure

Fw2

H2
Fw1

H1
Where,
Fw = Force due to wind
D= Dia. of tank = 8.5 M
H1 = Height of Tank = 9.25 M
H2 = Height of Roof = 0.75 M
Shape factor = 0.7
Wind pressure = 158.4 Kg/M2
CG1 = Centre of gravity for shell = 4.625 M
CG2 = Centre of gravity for roof = 9.50 M

Fw1 = Force on shell = 8717.94 Kgs


Fw2 = Force on roof = 353.14 Kgs

Overturning moment = Force x Centre of gravity


= ( Fw1 x CG1 ) + ( Fw2 x CG2 )
= 40320.47 + 3354.781
= 43675.25 Kg-M

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls WIND
Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
TANK WEIGHT
0 0

CALCULATION FOR TANK TOTAL WEIGHT (EXCLUDING STRUCTURALS)

(A) TANK SHELL:

SHELL MEAN DIA. HEIGHT THK. DENSITY WEIGHT REMARKS


COURSE NO. MM MM MM KG/M3 KGS
1 8505 1500 5 8050 1613.17
2 8505 1500 5 8050 1613.17
3 8505 1500 5 8050 1613.17
4 8505 1000 5 8050 1075.45
5
6
7
8

TANK SHELL WEIGHT = 5914.97 KGS

(B) TANK BOTTOM:

BOTTOM PLATE DIA. = 9410 MM


BOTTOM PLATE THK. = 6 MM

BOTTOM PLATE WEIGHT = 3359.05 KGS

(C) TANK ROOF:

ROOF PLATE DIA. = 8834.21 MM ROOF ANGLE, = 10


ROOF PLATE THK. = 5 MM ROOF SLOPE RADIUS IN MM =
4417.11
ROOF PLATE WEIGHT = 2467.13 KGS

(D) TANK NOZZLES / INTERNALS AND APPURTUNANCES:

LUMSUM = 500 KGS

TOTAL TANK WEIGHT = (A) + (B) + (C) + (D) = 12241.15 KGS


i.e. 12.24 MT

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls TANK WT.


Gujarat Narmada Valley
Fertilizers Company Limited
SCHEME NO.: PROJECT TITLE :
ANCHOR STRAPS / BOLTS
0 0
AS PER PARA 3.11.2, PAGE 3-50
For an unanchored tank, the overturning moment from wind pressure shall not exceed 2/3 of the
dead load resisting moment, excluding any tank contents, and shall be calculated as follows:

M < 2 WD = WD
3 2 3
where,
M= Overturning moment from wind pressure = 43675.25 Kg-M
W= Shell weight available to resist uplift, less any corrosion
allowance, plus dead wt. supported by shell minus
simultaneous uplift from operating conditions such as in Kgs
internal pressure on the roof.

SHELL WEIGHT AVAILABLE, W =


SHELL WEIGHT = 5914.97 KGS
ROOF WEIGHT = 2467.13 KGS
WT. OF STRUCTURE + ROOF
APPURTENANCES + HANDRAIL = 0 KGS (LUMSUM)
SHELL APPURTENANCES + STAIRCASE = 250 KGS (LUMSUM)
Total shell wt., W. = 8632.10 KGS

Thus, ( W D / 6 ) = 24457.61 Kg-M


which is LESS than M, i.e. 43675.25 Kg-M
HENCE, TANK ACHORAGE IS REQUIRED

AS PER PARA 3.11.3, PAGE 3-50


When anchor are required, the design tension load per anchor shall be
calculated as follows:
tB = 4M - W
dN N
where,
tB = design tension load per anchor in Kgs
d= diameter of anchor circle 8.61 in M
N= No. of anchors 4 (Assumed)
Anchors shall be spaced a maximum of 3 M. The allowable tensile
stress for anchors shall be in accordance with Appendix-F

tB = 5073 - 2158.02478
tB = 2914.6 Kgs.

Now, allowable stress at root of anchor bolt threades of tanks with design pressure upto 2.5
PSIG as per Table F-1, (Appendix-F) = 15000 PSI (Page F-5)
1055 Kg/Cm^2
Area reqd. for anchor bolt = 2.763 CM^2
= 276.3 MM^2
Dia. of anchor bolt required = 18.76 MM
Dia. of anchor bolt provided = 10 MM

DATE DESIGN BY : CHK. BY :


20-Apr-05 M (PJK) SM(RJH)

346424145.xls ANCHOR STRAPS


Gujarat Narmada Val
Fertilizers Company Lim
SCHEME NO.: WIND AND SIESMIC DESIGN AS PER IS-875 & IS-1893
0
Calculation for Forces and Moments :-
DATA :
Parameter
Wind Pressure
Empty Weight
Wt. full of water
Operating Weight
Force coeff.
Multiplication factor
Modulus of elasticity of matl.
Total Height of vessel
Height of vessel above base
Height of vessel upto skirt
Height of cylindrical shell
O.D. of vessel (Shell)
I.D. of vessel (Shell)
Mean radius of vessel
Thickness of shell
Joint efficiency
Coeff. of soil foundation
system (Table-3)
Importance factor
Acceleration due to gravity
Vibration coeff. (Table-5)
Seismic zone factor (Table-2)
2% critical damping ratio

Design Calculations :-
======================

h1 = H1 / 2 = 1600 MM

h2 = H1 + H2 / 2 = 7905 MM
---------------------------------------- ----------------------------------------------- -----------------------
|
| Unit Skirt portion
---------------------------------------- ----------------------------------------------- -----------------------
Eff. Dia. De | Mtrs. 2.20
---------------------------------------- ----------------------------------------------- -----------------------
Height H1, H2 | Mtrs. 3.20
---------------------------------------- ----------------------------------------------- -----------------------
Wind pressure Pw | Kg/cm^2 150.00
---------------------------------------- ----------------------------------------------- -----------------------
Shear Force V = PwDH | Kgf. 1056.00
---------------------------------------- ----------------------------------------------- -----------------------
Eff. Ht. h1, h2 | Mtrs. 1.60
---------------------------------------- ----------------------------------------------- -----------------------
Moment M1, M2 | Kgf-M. 1689.60
---------------------------------------- ----------------------------------------------- -----------------------

# Resultant Shear Force @V = 4161.300


# Resultant Wind Moment @M = 26236.997

Thus max. wind moment at base, M = 26237

$ CALCULATION FOR SEISMIC MOMENT :-


================ =========================== ====
a) Seismic Coefficient Method :

Qo = Basic seismic coefficient for zone-III =

Therefore, Design Seismic Coefficient, Qh = B * I * Qo


=

b) Response Spectrum Method :

Qo = Basic seismic coefficient for zone-III =


Re = radius of gyration
= 1/4 * ( Do^2 + Di^2 )^0.5 =
= 1/4 * ( 200^2 + 198.4^2 )^0.5 =
704.2840336114 MM =
70.43 CM
=====

r = (Do + Di)/4 =
996.00 MM
99.60 CM
=====

A = 2 * Pi * r * t =
500.64 CM^2
======

K = H / Re =
1.79
=====

Now T = Period of free vibration


= Ct * (Wt * h'/Es * A * g)^0.5 =
0.2251 Secs
======

0.156
=====

Max. (Seismic coeff. method, Response sprectrum method)


0.156
=====

Max. earthquake moment at the base,


Me = @h * Wt * 2/3H * 1.3 =
544837.51 Kg-M
==========

Thus, governing factor = Max. ( @M , @V ) =


544837.51 Kg-M (Wind load)
==========

Stress due to wind, S =


12 * wind moment x 1000 / Pi * R^2 * t =
262.235 Kg/MM^2
======

Hence, required thickness, tr =


12 * M * 1000 / R^2 * Pi * S * E =
9.41 MM
=====

DATE DESIGN BY :
20-Apr-05
Gujarat Narmada Valley
ertilizers Company Limited
ESIGN AS PER IS-875 & IS-1893 PROJECT TITLE :
0

Symbol Value Unit


Pw 158.4 Kg/M^2
W 12241.15 Kgs.
W1 524892.6 Kgs.
Wt 435660.9 Kgs.
Cf 0.8 ---
K 1.3 ---
Es 26600000 ---
H 9250 MM
h' 1261 CM
H1 3200 MM
H2 9410 MM
Do 2000 MM
Di 1984 MM
R 996 MM
t 8 MM
E 0.85 ---

B 1.5 ---
I 2.0 ---
g 981 Kg/CM^2
Ct 34.71 ---
Fo 0.2 ---
Sa/g 0.26 ---
-------------------------- ------------------------

Vessel above T.L.


-------------------------- ------------------------
2.20
-------------------------- ------------------------
9.41
-------------------------- ------------------------
150.00
-------------------------- ------------------------
3105.30
-------------------------- ------------------------
7.905
-------------------------- ------------------------
24547.40
-------------------------- ------------------------

Kgf.
Kgf-M.

Kgf-M.

0.04

0.12
==============

0.2
CHK. BY :
M (PJK) SM(RJH)

Você também pode gostar