Escolar Documentos
Profissional Documentos
Cultura Documentos
Ancillary Equipment
FIG. 381 SLIDING SUPPORT (WELDED TYPE)
For Pipework up to and Including 150NS For Pipework 200NS and above
04/10
04/10
Ancillary Equipment
FIG. 384-1
FIG. 384-2
Ancillary Equipment
FIG. 385
Material:-
Range A Carbon Steel (-20 to 100C)
340oC)
Range B Carbon Steel (101
(341 to
to 400C)
400oC)
Range C Alloy Steel
Ancillary Equipment
FIG. 386
Material:-
Material:-
Range A Carbon Steel (-20
Range (-20 to 340oC)
to 100C)
Range B
Range B Carbon
Carbon Steel
Steel (101
(341 to
to400C)
400oC)
Range C
Range C Alloy
Alloy Steel
Steel
Ancillary Equipment
FIG. 387
Material:-
Range A Carbon Steel (-20 to to 100C)
340oC)
Range BB Carbon
Carbon Steel
Steel (101
(341 to
to 400C)
400oC)
Range CC Alloy Steel
Steel
Ancillary Equipment
FIG. 388
Material:-
Range A Carbon Steel (-20 to 100C)
340oC)
Range B Carbon Steel (101
(341 to
to 400C)
400oC)
Range C Alloy Steel
Ancillary Equipment
FIG. 84 MEDIUM WELDED STEEL BRACKET Maximum Load - 700 Kg.
Size A B C D E F G H J L
Material - Carbon Steel.
0 305 465 395 30 65 110 40 40 5 22
1 460 615 545 30 65 130 50 50 6 22
When ordering specify:
2 610 770 700 30 65 130 50 50 6 22
Figure No.
Size
Size A B C D G H
Flat Maximum Load - 230 Kg.
E
1 305 460 380 14 76 30 100x10 Material - Carbon Steel.
2 460 610 535 14 76 30 100x10
3 610 760 685 18 76 30 100x12 When ordering specify:
4 760 915 840 18 76 30 100x12 Figure No.
5 915 1070 990 22 76 30 100x15 Size
Ancillary Equipment
FIG. 1007
PIPE GUIDE
Size A B C D E F G H J T
1 95 152 157 55 100 200 100 M12 150 6
2 110 180 183 70 130 200 100 M12 150 6
3 125 209 211 85 140 200 100 M12 150 8
4 150 260 262 110 160 200 100 M12 150 8
5 175 312 316 135 185 200 100 M16 150 10
6 200 378 398 210 280 200 100 M16 150 10
7 225 428 460 240 300 300 150 M20 230 15
8 250 479 511 280 340 300 150 M20 230 15
9 280 534 562 340 400 300 150 M24 230 20
10 305 584 612 380 460 300 150 M24 230 20
11 330 635 663 400 500 300 150 M24 230 20
Thickness of Insulation
Size
25 38 50 63 75 100
1 0-25
2 32-50 25
3 65 32-50 25
4 80-100 65-80 32-65 25-50 25
Material - Carbon Steel. Nominal
5 125
125-150 100-125 80-100 65-80 32-65 25
Pipe
Sleeve can be made longer for extreme travel conditions. 6 200 150 125-150 100-125 80-100 32-65 Sizes
Sleeve can be split at plus or minus 45 degrees if minimum 7 250 200 200 150 125-150 80-100
Dimension C is required for clearance. 8 300
- 250 250 200 200 125-150
9 350 300-350 300 250 250 200
S.W. Loads to suit specific applications. 10 400 400 350 300 300 250
11 400 400 350 300
When ordering specify:
Figure No.
Nominal Pipe Size
Thickness of Insulation
Guide Size No.
93