For nuclear weapons storage facilities, all sentry booth or


gatehouse designs shall be in accordance with NAVFAC P-272~
NAVFAC Drawing 1404126, ~ Sectitv ~ sDe& we~
~. The NAVFAC Definitive Drawing is considered the minimum design
and construction criteria for such facilities and are mandatory for facility
certification.

4.3.1 A sentry booth or gatehouse will be provided for all


entrance gates that are manned by security personnel on a full or part-time
basis. They should be located as close as possible to entry gates to permit
personnel inside the booth or gatehouse to maintain constant surveillance over
the entrance and approaches. In addition, site layout should allow for
vehicle inspections or search without causing undue traffic backups. Figure
20 depicts an ideal entry control point, locations, and roadway clearances.
Explosives safety criteria contained in NAVSEA OP 5, Volume 1, Ammunit~
E>:~losives Ash ore, Safetv Reau&@ ens for ~a. Storin~ ProducG
J@nova tion, and Shirmin- must be considered in siting sentry booths and
gatehouses at explosive component storage areas.

The entry control facility for nuclear weapons storage facilities


is part of the perimeter security system and is the point from which personnel
and vehicle control, and badge exchange operations are conducted. The
personnel entry gate and access route shall be arranged and constructed to
ensure that personnel pass the entry controller or badge exchange point and
enter the area singly under the positive cont~ol of the security force
(remotely operated gate, door, or turnstile controlled from within the gate
house). See Figure 21 for a typical entry control facility for special
weapons storage facility.

4.3.2 ~. As previously discussed, a thorough site


analysis and review of operational requixernents for the area involved must be
accomplished prior to initiating design of sentry booths or gatehouses.
NAVFAC P-80, ~V ~ provides general spacing criteria and
should be followed when designing sentry booths and gatehouses for other
facilities. A typical site-built gatehouse is shown in Figure 31. Some basic
considerations are provided in the following subparagraphs to assist the
designer.

4.3,2.1 $tmcture Size. When determining structure size consider the


number of personnel that will be assigned duzing normal operations, and the
electronic and electrical equipment (e.g., communications equipment and gate
controls) requirements. The mechanical support equipment (HYAC), storage
space, and space provided for such equipment in addition to security personnel
space allocations should also be determined. The surface area of any required
counter or work space must be added to the overall floor space requirements
for the structure.