CCD technology
Cost
Elimination film and consumables
ROI in two to three years
Quality
Image processing and analysis
Reduces operators fatigue
Consistency
Advanced Application
Volumetric CT for High Throughput
What is a good
Physical Measure of Image Quality?
Decreasing Noise
Contrast-to-Noise Ratio
Perceived Image Quality
Contrast
Limiting Spatial Resolution (LSR), MTF measured at high contrast
bar patterns 100% input contrast
MTF indicates fraction of signal that will be seen in image.
Noise
MTF measured under noiseless conditions.
MTF transfers noise in addition to signal.
Image noise can interfere with object detectability.
6/
Industrial Imaging and Modeling Laboratory
Quantifying Image Quality
MTF: High Middle Low
SNR = 1
High
MTF Middle
Higher limiting resolution of smaller
Low pixels may not provide better
detectability in noisy images.
Image Quality
DQE a
Input Radiation Dose
Traditional measures such as MTF, LSR are not sufficient to
characterize detector performance
Noise is a limiting factor for detectability, image processing,
and advanced applications
Film GE Detector
Pixel Size
MTF
Sampling, Fill
Factor, Aliasing High Resolution
(for small object
detection)
Scintillator/
Coupling
Signal (S) DQE
CsI, Lanex, Se
lens/Direct Efficient X-Ray Conversion
(for minimum exposure)
1 S 2 MTF 2
DQE =
Photodetector Q NPS
aSi, CCD,
CMOS
Noise (NPS)
Readout Low Noise
(for clear visualization)
Electronic Noise
14 /
Industrial Imaging and Modeling Laboratory
Flat Panel Technology
Light
Electrons
MTF is One Part of the Story, DQE is the Other BIG Part
17 /
Industrial Imaging and Modeling Laboratory
CCD Technology
Photons
Scintillator
Light
Fiber Optic Taper
CCD
Electrons
Amorphous Silicon CCD
Pixel Dimensions
CCDs: 9 25 microns
CMOS: 40 50 microns
a-Si: 100 400 microns
Lens
Fiber optic scintillator and/or Shielding Cooled CCD
phosphor Glass Camera
20 /
Industrial Imaging and Modeling Laboratory
Outstanding Image Quality and Dose
Efficiency
14000
12000
Signal(ADC)
10000
8000
6000
4000
2000
0
0 5 10 15 20 25 30 35
Relative exposure
> No distortion
Flat panel
> No blooming XII
> Uniform sensitivity over Source:GE Health care
entire area
Brightness uniformity
> Brightness uniformity
25 /
Industrial Imaging and Modeling Laboratory
Performance study-Spatial resolution
Observation:
System can be designed to match with film MTF.
Digital detector with mini/micro focal tube outperforms
film radiography with large focal spots.
DQE of DXR-500 is comparatively good.
5 frames
Effect of no. of frames
20 frames
5 mAs
Lack of
penetration
Kvp 125
mAs 1.0
FS 0.4
mm
Mat. CSI
Object IC
Object ceramics
Kv 70
Kvp 70
mAs .5
mAs .5
FS 10 microns
FS 10 microns
Mag. 50X
Mag. 50X
31 /
Enable high definition radiography Industrial Imaging and Modeling Laboratory
Welding defects-Lack of penetration
and spatter
Material: CS
Plate, 12 mm thk
SW SI Offset
FS-0.4 mm
SDD-700 mm
Kv: 130, 2 mas
Filter: Cu 0.4 mm
32 /
Industrial Imaging and Modeling Laboratory
Summary
33 /
Industrial Imaging and Modeling Laboratory