Você está na página 1de 4

L A Y - I N & L A Y - O N T I L E S

ARCHITECTURAL PRODUCTS

www.luxalon.com
T I L E S SYSTEM OVERVIEW LAY-IN & LAY-ON TILES

ISO 9002
SHORT SYSTEM DESCRIPTION
Lloyds Quality
Assured Firm

Luxalon Lay-In & Lay-On tiles are


1
designed to be installed in convention-
C
al T-Grid systems with T-Bar sizes of
15 mm, 24 mm or 26 mm. By push-
B
ing the tile up-wards, all types provide
A
easy access to the plenum without the
use of special tools.
The exposed T-Grid of Luxalon Lay-In 3

& Lay-On tiles emphasises the modular


design pattern. A more distinctive
emphasis can be provided by the use of
2
wide T-grids and 16 mm deap reveals, B

or less prominent by using 15 mm


T-grids and an 8 mm reveal.

PRACTICAL APPLICATION AREAS


1. Lay-In tile A = 1200 mm (max.)
Luxalon Lay-In and Lay-On tiles 2. T-grid B = module
provide easy access and are ideal for 3. Hangers C = 250 mm (max.)
situations where regular maintenance
or service is required to ducts, pipes,
aircon-systems, or computer-or tele- DIMENSIONS
phone networks. Before selecting this
system, care should be taken to LAY-IN TILES 15/8; 15 mm Grid, LAY-IN TILES 24/0; 24 mm Grid,
ensure that there is enough space in 8 mm Reveal 0mm Reveal
the plenum to lift the tiles upward Module in mm Gauge: steel Alu. Module in mm Gauge: steel Alu.
Because the Luxalon Lay-In and 500 x 500 0.5 0.6 600 x 600 0.5 0.6
Lay-On system offers easy access and 600 x 600 0.5 0.6
adaptability, lighting and services 625 x 625 0.5 0.6
can be conveniently repositioned. 675 x 675 0.5 0.6
This is particularly useful for super-
markets, laboratories, computer LAY-IN TILES 15/16; 15 mm Grid, LAY-IN TILES 26/16; 26 mm channel
suites and offices 16 mm Reveal Grid
Module in mm Gauge: steel Alu. Module in mm Gauge: steel Alu.
600 x 600 0.5 0.6 600 x 600 0.5 0.6
625 x 625 0.5 0.6 625 x 625 0.5 0.6

* T-profile with integrated fixing


LAY-IN TILES 24/8; 24 mm Grid, possibility for partitions
8 mm Reveal
Module in mm Gauge: steel Alu.
500 x 500 0.5 0.6
600 x 600 0.5 0.6
625 x 625 0.5 0.6
37

LAY-IN TILES 24/16; 24 mm Grid, LAY-ON TILES


16 mm Reveal 15/24; 15 or 24 mm Grid
Module in mm Gauge: steel Alu. Module in mm Gauge: steel Alu.
500 x 500 0.5 0.6 600 x 600 0.5 0.6
600 x 600 0.5 0.6 625 x 625 0.5 0.6
*

M M 625 x 625 0.5 0.6

* Depth of reveal
MATERIAL SPECIFICATIONS
MATERIAL REQUIREMENT PER M2
Components Unit 600x600 625x625
- B A S E M AT E R I A L
Tiles pcs 2.78 2.56
Luxalon Lay-In and Lay-On tiles are
Grid Profile m1 3.34 3.2 available in electrolytic-galvanised
Suspension pcs 0.69 0.64 steel, phosphatised and chemically
treated in accordance with high indus-
UPWARD ACCESSIBILITY trial standards (DIN 1541/BS
1449,part 1:1983/TAIM standards).
Because each tile has flanges that simply rest on the T-Grid profiles, the access to Zinc coating is double sided and 2.5
the plenum is achieved by lifting the tile up into the area above the ceiling. microns.
Aluminium alloy AL 99.5RA, 3/4
ACOUSTIC PERFORMANCE hard (according to DIN 1783) or stain-
less steel alternatives are also possible,
In order to improve interior sound control, the Luxalon Tile and Plank pro- when required.
gramme can be perforated in a range of standard patterns with open areas between
16% and 60%. These patterns are framed with a plain border of 10 mm in order to - C O AT I N G
assure maximum flatness and product stability. As a standard feature, perforated The tough and durable polyester pow-
tiles can be supplied with a soundabsorbing non-woven tissue glued into the tile dercoating finish in a minimal thick-
for enhanced acoustical performance. ness of 60 microns, is electrostatically
applied ensuring uniform coating
thickness, absolute adhesion, maxi-
SOUND ABSORPTION Freq. Hz 125 250 500 1000 2000 4000 mum resistance to abrasion. Because
Curve 1 0.31 0.68 0.87 0.74 0.95 0.96
C U RV E 1 Curve 2
Curve 3
0.51
0.48
0.77
0.97
0.92
1.07
0.72
0.97
0.80
1.06
0.80
1.08 Luxalon coatings are applied after
2.5 mm perforated tiles, 20 mm thick mineral wool pad
with a density of approx. 20 kg/m, plenum depth 200 mm. 1.2
Absorption Coefficient GS 391/88/e perforation and bending process,
C U RV E 2 1
3
exposed edges are protected. Standard
1
o
2.5 mm perforated tiles, non-woven acoustic felt, plenum
0.8
gloss rate is 15 - 20% at 60 angle of
depth 200 mm. 2

C U RV E 3 0.6
incidence.
1.5 mm perforated tiles, 40 mm thick mineral wool pad
0.4
with a density of approx. 20 kg/m, plenum depth 200 mm.
0.2
- COLOUR RANGE
All curves tested according to DIN 52215,
BS 3638 and ISO 354. 0
The standard colours range includes a
125 250 500
Frequency
1000 2000 4000 range of whites and a metallic silver
colour. Any other RAL, BS or NCS
TYPICAL SOUND ATTENUATION colour is available on request.
Normalised Level Difference
Freqency (Hz) 125 250 500 1000 2000 3150 Standard Colour Range
Microperforated Tile + Acoustipanel 19.5 26.6 32.5 39.3 48.2 48.9 dB RAL 9001 white
Microperforated Tile + Mineral Wool 15.9 21.4 28.7 39.3 56.2 62.5 dB RAL 9002 white
100 kg/m3 (40 mm thick) RAL 9016 white
Microperforated Tile + Acoustipanel 25.0 31.8 36.7 44.8 50.8 52.8 dB RAL 9010 white
+ Backing Plate RAL 9006 silver

- TOLERANCES
As a member of the Technical
Association of Industrial Metal Ceiling
PERFORATION PATTERNS Manufacturers (TAIM), Hunter
Douglas complies with tolerance crite-
ria as specified in chapter 4 of the
STANDARD PERFORATION ALTERNATIVE PERFORATIONS
TAIM Quality standards for metal.
106 138 103 107 132 136
The TAIM standards are available on
request.

- F I R E B E H AV I O U R
Perforation direction n

Suspended Luxalon metal ceilings are


classified incombustible, and will
therefore not contribute to possible
fires. When ceilings however need to
2.4 mm 1.5 mm 3 mm 4 mm 1,8 mm / 10 mm
3

16 % open 22% open 20% open 28% open 20% open 60% open
protect the structural integrity of a
b 5.5 n 5.5 b 2.15 n 4.3 b 5.5 n 6.35 b 6.5 n 6.5 b 2.5 n 5 b 13.4 n 13.4 building, Luxalon ceilings offer a
wide range of practical solutions with
Note: Perforated products have a nominal plain border of 10 mm. regards to fire resistance and fire sta-
bility. Further information is available
on request.
S PECIFICATION 3.4 COATING
Architect will make a colour
L AY-I N & L AY O N T ILE C EILING S YSTEM selection from the standard
Hunter Douglas colour range
for Luxalon Tiles RAL code
PART 1 LAY-IN GENERAL no. ______ or a special colour
will be made to match ______.
1.1 INTRODUCTION
The coating will consist of a
Supply and fix Luxalon Lay-In, Lay On Tile Ceiling System as manufac- durable polyester powdercoat-
tured by Hunter Douglas Architectural Products. ing finish in a minimal thick-
ness of 60 microns,
1.2 DESCRIPTION OF THE SYSTEM electrostatically applied onto
electro-galvanised steel,
The system will consist of metal tiles laid into a 15 mm or 24 mm slot- phosphatised and chemically
ted tee bar system. treated according to high
industrial standards
PART 2 PRODUCT (DIN 1541/ TAIM standards).

2.1 TILES
____ m2 Luxalon Lay-in Tile Ceiling consisting of : 3.5 INSTALLATION
All materials shall be installed
Square edged tiles which are 591 x 591 mm (module 600 x 600) or in strict compliance with all
616 x 616 mm (module 625 x 625) made of 0.5 mm thick steel. local codes, ordinances and
The square edged tiles are designed to lay recessed 8 mm or 16 mm manufacturers recommenda-
below the level of the tee bar, lay in flush with the tee bar, or lay on the tions including specific addi-
tee bar. tional requirements as may be
called for in the specifications
or shown on the drawings.
2.2 SUSPENSION
Consists of pre-punched main tee sections installed in a grid by means of 3.6 SUBSTITUTIONS
inserting cross tees which are designed to be used with the size of tile Ceiling installers wishing to
selected (see 2.1). submit proposals on systems
other than the Luxalon Tile
Maximum distance of rapid hangers fixing points on the main tee is Ceiling System shall, at least
1200 mm. Main tees and cross tees will be finished standard baked 10 days in advance of the bid
white enamel finish. Matching colours to the tiles are available on date, submit to the architect
request. complete descriptive informa-
tion of the total system concept
and performance data tests
PART 3 LUXALON TILE GENERAL made as a system.
In addition include a list of
3.1 EDGE COVER PROFILES similar installations of the pro-
L-profile 25 x 25 mm, made of 1.5 mm thick aluminium. posed substitution. If approval www.luxalon.com
W-profile, 25 x 25 x 25 x 25 mm, made of 1.5 mm thick aluminium. is made an addendum will be
F-profile, 25 x 25 mm, made of 1.5 mm thick aluminium. issued enumerating such
Stepped F-profile, 25 x 25 x 25 x 25 mm, made of 1.5 thick aluminium. approved system as herein set
forth.
3.2 PERFORATIONS
Manufacturer shall supply tiles with perforation pattern no. ______
with a nominal 10 mm plain border on all sides.
Perforations will have a ________ diameter hole resulting in a
________ % open area. Other borders on request.

3.3 ACOUSTICS
Manufacturer shall supply acoustic non-woven textile, thickness 0.2 mm
glued into the tile or black faced PE wrapped mineral wool thickness
____ mm density ____ kg/m3 and of a size to completely fill the tile.

LUXALON CEILING SYSTEMS


Unit 7 & 8 Keys Business Park - Keys Park Road - Hednesford - WS12 5GW
Tel. (01543) 273620 - Fax (01543) 270084 - e-mail: luxalon-ceilings@hunter-douglas.co.uk - www.luxalon.com
Registered trademark - a HunterDouglas product Pats. & Pats. Pend. - Technical data subject to change without notice. MX665QW0
Copyright HunterDouglas 2003. No rights can be derived from copy, text pertaining to illustrations or samples. Subject to changes in materials, parts, composi-
tions, designs, versions, colours etc., even without notice.