Você está na página 1de 12

ELCOSMO

E
TOSHIBA COMPACT MACHINE ROOM ELEVATORS
TOSHIB
Installation plan and power facility plan for Indonesia

TB408_[001-012]_IN.indd 1 09.9.17 10:34:30 AM


Hoistway layout Counterweight at side

Machine room width M.A


Hook (By general contractor)

Machine room height M.H

(By general contractor)


Control panel
Dust-proofed

Window
(By general contractor)

Machine room depth M.B

(By general contractor)


Ventilation fan

(By general contractor)


Power Switch
Overhead OH

Machine room door


(With key)
(By general contractor)
Door height

600Wx1800H

Lighting switch
inspection receptacle
(By general contractor)

Top floor

Machine room plan


Total height
Travel

Car inside depth B

Hoistway depth Y

Pit inspection receptacle Hoistway


centerline Car centerline
(By general contractor)

Ladder
(By general
contractor) Bottom floor
Pit depth P

Door opening width W

Car inside width A

Pit waterproof Hoistway width X


Hoistway lighting (By general contractor)
(By general contractor)

Hoistway section Hoistway plan

TB408_[001-012]_IN.indd 2 09.9.17 10:34:34 AM


Specifications

Cage size Machine room


Hoistway size (mm)
(mm) Door width dimensoins (mm) Motor Max. Max.
Nos.of Capacity Speed
Type W capacity service travel
Person (kg) (m/s)
Internal (A x B) (mm) (kw) stops (s) (m)
XxY OH P M.A x M.B M.H

W 800 18201770 18201770


P8-CO60 1 4050 1300 3.6 24 60
W 900 20001770 20001770
W 800 18201770 18201770
P8-CO96 1.6 4300 1400 5.8 32 100
W 900 20001770 20001770
W 800 18201770 18201770
P8-CO105 8 550 1.75 11001400 4300 1450 2000 6.3 32 100
W 900 20001770 20001770
W 800 18201770 18201770
P8-CO120 2 4350 1650 7.2 40 125
W 900 20001770 20001770
W 800 18201770 18201770
P8-CO150 2.5 4350 2100 9.0 40 125
W 900 20001770 20001770
W 800 19451770 19451770
P11-CO60 1 4050 1300 4.6 24 60
W 900 20501770 20501770
W 800 19451770 19451770
P11-CO96 1.6 4300 1400 7.3 32 100
W 900 20501770 20501770
W 800 19451770 19451770
P11-CO105 11 750 1.75 13501400 4300 1450 2000 8.0 32 100
W 900 20501770 20501770
W 800 19451770 19451770
P11-CO120 2 4350 1650 9.2 40 125
W 900 20501770 20501770
W 800 19451770 19451770
P11-CO150 2.5 4350 2100 11.4 40 125
W 900 20501770 20501770
D 800 18202070 18202070
P11-CO60 1 4050 1300 4.6 24 60
D 900 20002070 20002070
D 800 18202070 18202070
P11-CO96 1.6 4300 1400 7.3 32 100
D 900 20002070 20002070
D 800 18202070 18202070
P11-CO105 11 750 1.75 11001700 4300 1450 2000 8.0 32 100
D 900 20002070 20002070
D 800 18202070 18202070
P11-CO120 2 4350 1650 9.2 40 125
D 900 20002070 20002070
D 800 18202070 18202070
P11-CO150 2.5 4350 2100 11.4 40 125
D 900 20002070 20002070
W 900 21751770 21751770
P13-CO60 1 4050 1300 5.7 24 60
W 1000 22751770 22751770
W 900 21751770 21751770
P13-CO96 1.6 4300 1400 9.2 32 100
W 1000 22751770 22751770
W 900 21751770 21751770
P13-CO105 13 900 1.75 16001400 4300 1450 2000 10.0 32 100
W 1000 22751770 22751770
W 900 21751770 21751770
P13-CO120 2 4350 1650 11.4 40 125
W 1000 22751770 22751770
W 900 21751770 21751770
P13-CO150 2.5 4350 2100 14.3 40 125
W 1000 22751770 22751770
D 800 18202470 18202470
P14-CO60 1 4050 1300 5.7 24 60
D 900 20002470 20002470
D 800 18202470 18202470
P14-CO96 1.6 4300 1400 9.2 32 100
D 900 20002470 20002470
D 800 18202470 18202470
P14-CO105 14 950 1.75 11002100 4300 1450 2000 10.0 32 100
D 900 20002470 20002470
D 800 18202470 18202470
P14-CO120 2 4350 1650 11.4 40 125
D 900 20002470 20002470
D 800 18202470 18202470
P14-CO150 2.5 4350 2100 14.3 40 125
D 900 20002470 20002470

Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P13W W: Wide car D: Deep car

TB408_[001-012]_IN.indd 3 09.9.17 10:34:38 AM


Hoistway layout Counterweight at side

Hook (By general contractor) Machine room width M.A

(By general contractor)


Window
Machine room height M.H
Control panel

Machine room depth M.B


Dust-proofed
(By general contractor)

(By general contractor)


Ventilation fan

(By general contractor)


Power switch
Machine room door
(With key)
(By general contractor)
600W1800H

Overhead OH Lighting switch


inspection receptacle
(By general contractor)
Door height

Machine room plan


Top floor

Car inside depth B

Hoistway depth Y
Hoistway Car
centerline centerline

Door opening width W

Car inside width A


Total height
Travel

Hoistway width X

Center opening door


hoistway plan
(Type: P15W)

Pit inspection receptacle


(By general contractor)
Ladder
(By general contractor)
Car inside depth B

Car
Hoistway depth Y

centerline
Bottom floor
Pit depth P

Hoistway
centerline
Hoistway lighting Pit waterproof
(By general contractor) (By general contractor)

Hoistway section Door opening width W

Car inside width A

Hoistway width X

Two panel slide door


Hoistway plan
(Type: P17D, P21D)

TB408_[001-012]_IN.indd 4 09.9.17 10:34:42 AM


Specifications
Cage size Machine room
Hoistway size (mm)
(mm) Door width dimensoins (mm) Motor Max. Max.
Nos.of Capacity Speed
Type W capacity service travel
Person (kg) (m/s)
Internal (A x B) (mm) (kw) stops (s) (m)
XxY OH P M.A x M.B M.H

W 1000 25001980 25001980


P17-CO60 1 4050 1300 7.3 24 60
W 1100 26001980 26001980
W 1000 25001980 25001980
P17-CO96 1.6 4300 1400 11.6 32 100
W 1100 26001980 26001980
W 1000 25001980 25001980
P17-CO105 17 1150 1.75 18001500 4300 1450 2000 12.6 32 100
W 1100 26001980 26001980
W 1000 25001980 25001980
P17-CO120 2 4350 1650 14.4 40 125
W 1100 26001980 26001980
W 1000 25001980 25001980
P17-CO150 2.5 4700 2100 18.0 40 125
W 1100 26001980 26001980

P18-2S60 D 1 4050 1300 8.7 24 60

P18-2S96 D 1.6 4300 1400 14.0 32 100

P18-2S105 D 18 1275 1.75 12002500 1100 21003050 4300 1450 21003050 2200 16.0 32 100

P18-2S120 D 2 4350 1650 18.0 40 125

P18-2S150 D 2.5 4700 2100 20.0 40 125

P23-2S60 D 1 4050 1300 10.0 24 60

P23-2S96 D 1.6 4300 1400 16.0 32 100

P23-2S105 D 23 1600 1.75 14002600 1200 23003150 4300 1450 23003150 2200 18.0 32 100

P23-2S120 D 2 4350 1650 20.0 40 125

P23-2S150 D 2.5 4700 2100 24.0 40 125

Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P17W W: Wide car D: Deep car

TB408_[001-012]_IN.indd 5 09.9.17 10:34:45 AM


Hoistway layout Counterweight at rear

Hook (By general contractor) Machine room width M.A

Machine room height M.H

(By general contractor)


Ventilation fan

(By general contractor)


Dust-proofed
(By general contractor)

Machine room depth M.B

Window
Power switch
(By general contractor)

Control panel
Overhead OH

Machine room door


(With key)
(By general
contractor)
Lighting switch 600W1800H
inspection receptacle
Door height

(By general contractor)

Top floor
Machine room plan
Total height
Travel

Car inside depth B

Hoistway depth Y

Door opening width W

Car inside width A

Pit inspection receptacle


(By general contractor) Hoistway width X
Ladder
(By general contractor)
Hoistway plan
Bottom floor
Pit depth P

Hoistway lighting Pit waterproof


(By general contractor) (By general contractor)

Hoistway section

TB408_[001-012]_IN.indd 6 09.9.17 10:34:49 AM


Specifications

Cage size Machine room


Hoistway size (mm)
(mm) Door width dimensoins (mm) Motor Max. Max.
Nos.of Capacity Speed
Type W capacity service travel
Person (kg) (m/s)
Internal (A x B) (mm) (kw) stops (s) (m)
XxY OH P M.A x M.B M.H

W 800 18501680 18501680


P8-CO60 1 4050 1300 3.6 24 60
W 900 19501680 19501680
W 800 18501680 18501680
P8-CO96 1.6 4300 1400 5.8 32 100
W 900 19501680 19501680
W 800 18501680 18501680
P8-CO105 8 550 1.75 14001100 4300 1450 2000 6.3 32 100
W 900 19501680 19501680
W 800 19501780 19501780
P8-CO120 2 4350 1650 7.2 40 125
W 900 20501780 20501780
W 800 19501780 19501780
P8-CO150 2.5 4350 2100 9.0 40 125
W 900 20501780 20501780
W 800 18502000 18502000
P11-CO60 1 4050 1300 4.6 24 60
W 900 19502000 19502000
W 800 18502000 18502000
P11-CO96 1.6 4300 1400 7.3 32 100
W 900 19502000 19502000
W 800 18502000 18502000
P11-CO105 11 750 1.75 14001350 4300 1450 2000 8.0 32 100
W 900 19502000 19502000
W 800 19502100 19502100
P11-CO120 2 4350 1650 9.2 40 125
W 900 20502100 20502100
W 800 19502100 19502100
P11-CO150 2.5 4350 2100 11.4 40 125
W 900 20502100 20502100
W 900 21002050 21002050
P13-CO60 1 4050 1300 5.7 24 60
W 1000 22002050 22002050
W 900 21002050 21002050
P13-CO96 1.6 4300 1400 9.2 32 100
W 1000 22002050 22002050
W 900 21002050 21002050
P13-CO105 13 900 1.75 16001400 4300 1450 2000 10.0 32 100
W 1000 22002050 22002050
W 900 22002150 22002150
P13-CO120 2 4350 1650 11.4 40 125
W 1000 23002150 23002150
W 900 22002150 22002150
P13-CO150 2.5 4350 2100 14.3 40 125
W 1000 23002150 23002150

Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P13W W: Wide car

TB408_[001-012]_IN.indd 7 09.9.17 10:34:52 AM


Hoistway layout Counterweight at rear

Hook (By general contractor)

Machine room height M.H

(By general contractor)


Ventilation fan

(By general contractor)


Machine room depth M.B
Dust-proofed

Window
(By general contractor)

Power switch
(By general contractor)

Control panel
Overhead OH
Machine room door
(With key)
(By general
contractor)
Lighting switch 600W1800H
inspection receptacle
(By general contractor)
Door height

Machine room plan(P15W)


Top floor

Machine room width M.A


(By general contractor)

(By general contractor)


Ventilation fan
Machine room depth M.B

Window
Power switch
(By general contractor)

Machine room door


Total height

600W1800H
Travel

(By general
contractor)
(With key)

Control panel

Lighting switch
inspection receptacle
(By general contractor)

Machine room plan(P17WP24W)

Pit inspection receptacle


(By general contractor)
Ladder
(By general contractor)

Bottom floor
Car inside depth B

Hoistway depth Y
Pit depth P

Hoistway lighting Pit waterproof


(By general contractor) (By general contractor)

Hoistway section
Door opening width W

Car inside width A

Hoistway width X

Hoistway plan

TB408_[001-012]_IN.indd 8 09.9.17 10:34:57 AM


Specifications

Cage size Machine room


Hoistway size (mm)
(mm) Door width dimensoins (mm) Motor Max. Max.
Nos.of Capacity Speed
Type W capacity service travel
Person (kg) (m/s)
Internal (A x B) (mm) (kw) stops (s) (m)
XxY OH P M.A x M.B M.H

W 1000 23002190 23002190


P17-CO60 1 4050 1300 7.3 24 60
W 1100 24502190 24502190
W 1000 23002190 23002190
P17-CO96 1.6 4300 1400 11.6 32 100
W 1100 24502190 24502190
W 1000 23002190 23002190
P17-CO105 17 1150 1.75 18001500 4300 1450 2200 12.6 32 100
W 1100 24502190 24502190
W 1000 23002190 23002190
P17-CO120 2 4350 1650 14.4 40 125
W 1100 24502190 24502190
W 1000 23002190 23002190
P17-CO150 2.5 4700 2100 18.0 40 125
W 1100 24502190 24502190

P18-CO60 W 1 4050 1300 8.7 24 60

P18-CO96 W 1.6 4300 1400 14.0 32 100

P18-CO105 W 18 1275 1.75 20001500 1100 25502200 4300 1450 25502200 2200 16.0 32 100

P18-CO120 W 2 4350 1650 18.0 40 125

P18-CO150 W 2.5 4700 2100 20.0 40 125

P19-CO60 W 1 4050 1300 8.7 24 60

P19-CO96 W 1.6 4300 1400 14.0 32 100

P19-CO105 W 19 1350 1.75 20001550 1100 25502250 4300 1450 25502250 2200 16.0 32 100

P19-CO120 W 2 4350 1650 18.0 40 125

P19-CO150 W 2.5 4700 2100 20.0 40 125

W 1100 25502500 25502500


P23-CO60 1 4050 1300 10.0 24 60
W 1200 27002500 27002500
W 1100 25502500 25502500
P23-CO96 1.6 4300 1400 16.0 32 100
W 1200 27002500 27002500
W 1100 25502500 25502500
P23-CO105 23 1600 1.75 20001800 4300 1450 2200 18.0 32 100
W 1200 27002500 27002500
W 1100 25502500 25502500
P23-CO120 2 4350 1650 20.0 40 125
W 1200 27002500 27002500
W 1100 25502500 25502500
P23-CO150 2.5 4700 2100 24.0 40 125
W 1200 27002500 27002500

P26-CO60 W 1 4050 1400 12.0 24 60

P26-CO96 W 1.6 4300 1550 18.0 32 100


26 1800 21001800 1200 27002600 27002600 2200
P26-CO105 W 1.75 4300 1650 20.0 32 100

P26-CO120 W 2 4350 1900 22.0 40 125

Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
Example: P17W W: Wide car

TB408_[001-012]_IN.indd 9 09.9.17 10:35:00 AM


Hoistway layout Front and rear opening door (Counterweight at side)

Hook (By general contractor) Machine room width M.A

(By general contractor)


Machine room height M.H
Control panel

Window
Machine room depth M.B
Dust-proofed

(By general contractor)


(By general contractor)

Ventilation fan

(By general contractor)


Power switch
Overhead OH
Lighting switch
inspection receptacle
(By general contractor)
Door height

Top floor

Car inside depth B

Hoistway depth Y
Total height
Travel

Door opening width W

Car inside width A

Hoistway width X

Front and rear opening


hoistway plan
(Type: P13D2)

Pit inspection receptacle


(By general contractor)

Ladder
Car inside depth B

Car
Hoistway depth Y

(By general contractor) centerline


Bottom floor
Pit depth P

Hoistway
centerline

Hoistway lighting Pit waterproof


(By general contractor) (By general contractor)

Front and rear opening Door opening width W

hoistway section Car inside width A

Hoistway width X

Front and rear opening


hoistway plan
(Type: P21D2)

TB408_[001-012]_IN.indd 10 09.9.17 10:35:04 AM


Specifications

Cage size Machine room


Hoistway size (mm)
(mm) Door width dimensoins (mm) Motor Max. Max.
Nos.of Capacity Speed
Type W capacity service travel
Person (kg) (m/s)
Internal (A x B) (mm) (kw) stops (s) (m)
XxY OH P M.A x M.B M.H

P14-CO60 D2 1 4050 1300 5.7

P14-CO96 D2 1.6 4300 1400 9.2

P14-CO105 D2 14 950 1.75 11002100 800 18202610 4300 1450 18202610 2000 10.0 1

P14-CO120 D2 2 4350 1650 11.4

P14-CO150 D2 2.5 4350 2100 14.3

P23-2S60 D2 1 4050 1300 10.0

P23-2S96 D2 1.6 4300 1400 16.0

P23-2S105 D2 23 1600 1.75 14002600 1200 23003270 4300 1450 23003270 2200 18.0 1

P23-2S120 D2 2 4350 1650 20.0

P23-2S150 D2 2.5 4700 2100 24.0

Please contact us.

Note:
Hoistway dimensions are the minimum dimension after the building work.
Hoistway dimensions are the minimum requirement.
The hoistway structure wall must be 150mm thick or more.
Piping, wiring and cables not related to elevator are prohibited inside the hoistway.
In case that more than one (simplex) elevator is required, please contact us.
If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.
The front and rear opening floor are less than 8 floor
Example: P13D2 D2Front and rear opening door deep car

10

TB408_[001-012]_IN.indd 11 09.9.17 10:35:06 AM


Observance of relevant laws / regulations are required.
Safety Cautions Read the entire Instruction Manual carefully before use, for important information about safety, handling and operation.

5-27, Kitashinagawa 6-chome, Shinagawa-ku,


Tokyo 141-0001 Japan
PHONE: +81-3-5423-3389 FAX: +81-3-5423-2746

The data given in this catalog are subject to change without notice.

Printed in Japan

GK-F13650-09.09 300-09.09XW

TB408_[001-012]_IN.indd 12 09.9.17 10:35:15 AM