Escolar Documentos
Profissional Documentos
Cultura Documentos
QH Isolating Switches 10
Features 10
Selection Data 14
DIN Miniature Circuit Breakers, Isolating Switches, Miniature RCBOs, Miniature RCDs 14
QH 10kA Range
QH Miniature Circuit Breakers & RCBOs
The new QH Range of MCBs & RCBOs provide safe and reliable solutions for low voltage electrical
protection against overload and short circuit, delivering reliability, strength and efficient protection
for commercial, industrial and mining applications.
Features:
DIN mounting
High selectivity
18mm Module width
Compatible withbetween MCB and back-up fuse due to low let-through energy
Twin-purpose terminal
standard busbar
Busbar positioning optionally
(lift/open-mouthed) above & below
Meets the requirements of insulation
above or below
4 mm, for secure isolation. co-ordination, distance between contacts
Accessories:
Auxiliary switch (add on, field mountable) Enclosures
Trip alarm ( add on, field mountable) Additional terminal 35mm
Undervoltage
Shunt trip release (add on, field mountable) Anti-tamper device (handle lock)
release (add on, field mountable)
Technical Characteristics:
Electrical Mechanical
Compliance: AS/NZS 60898.1 Frame size: 45mm
(Approval No NSW25003)
Rated voltage: 230/400V AC Device size: 80mm (height), 17.5mm (width)
48V DC (per pole) Mounting: DIN rail (EN 50022)
Rated frequency: 50/60Hz Degree of protection: IP20 (when installed)
Breaking capacity (Ics=Icu): 10kA Terminals: Open mouthed lift terminals
Time delay characteristic: Curves: 1, 2 Terminal protection: Touch safe, VBG 4, VE-EN 6
Back up fuse: Max. 125A gL Terminal capacity: 1 25mm
Selectivity class: 3 Fastening torque: 2 2.4Nm
Endurance: > 8000 operating cycles Busbar thickness: 0.8 2mm
Line voltage connection: Optional (above/below) Mounting position: Any
CURVE 1 CURVE 2
Operating Operating
Characteristics Characteristics
MINUTES
MINUTES
Ambient Temperature 30C Ambient Temperature 30C
SECONDS
SECONDS
TRIPPING TIME
TRIPPING TIME
Connection Diagrams:
1-pole 1+N-pole 2-pole 3-pole 3+N-pole
Dimensions (mm):
1-pole 2p & 1pole+N 3-pole 3 pole + N
Features:
DIN mounting
Independent
27mm Module width
80 to 125A ratings
switching contacts
With isolator function, meets the requirements of insulation coordination,
distance between contacts 4mm, for secure isolation.
High current limit
Accessories:
Auxiliary switch (add on, field mountable) Anti-tamper device (handle lock)
Shunt trip release
Trip alarm ( add on, field mountable) Busbar
(add on, field mountable)
Technical Characteristics:
Electrical Mechanical
Compliance: I EC/EN 60947-2 Frame size: 45mm
Rated voltage: 230/400V AC Device size: 90mm (height), 27mm (width)
60V DC (per pole) Mounting: DIN rail (EN 50022)
Rated frequency: 50/60Hz Degree of protection: IP20 (when installed)
Breaking capacity (Icu=Ics): 10kA Terminals: Open mouthed lift terminals
Time delay characteristic: Curves: 1, 2 Terminal protection: Touch safe, VBG 4, VE-EN 6
Back up fuse: Max. 200A gL Terminal capacity: 2.5 50mm
Selectivity class: 3 Mounting position: Any
Endurance: 20000 operating cycles
Rated insulation voltage: 440V
Peak withstand voltage: 4kV
CURVE 1 CURVE 2
Operating Operating
Characteristics Characteristics
MINUTES
MINUTES
Ambient Temperature 30C Ambient Temperature 30C
SECONDS
SECONDS
TRIPPING TIME
TRIPPING TIME
Connection Diagrams:
1-pole 1+N-pole 2-pole 3-pole 3+N-pole
Dimensions (mm):
1-pole 2p & 1pole+N 3-pole 3 pole + N
Features:
DIN mounting
1+N-pole, 1 module width, allows for extra wiring room in boards
miniature circuit
Electronic residual current device /
breaker combination in only 1MU
Contact position indicator
Tripping line voltage dependent
Can be sealed with leads inredtheongreen
Rated currents available 632A (Curve and off position
Permanently connected neutral conductor 2), 620A (Curve 1)
Can be connected to standard busbar (at the(1100mm long)
Type A RCD lower side)
Accessories:
Auxiliary switch for subsequent installation Shunt trip release
Tripping signal switch for subsequent installation Tripping module
Technical Characteristics:
Electrical
Compliance: AS/NZS 60898 (Approval No NSW 25355)
No of Poles: 1+N-Pole switched, N Led through (solid neutral)
Rated voltage: 240 VAC
Rated frequency: 50/60Hz
Rated current: 6-32A (Curve 2), 6-20A (Curve 1)
Rated tripping current: 10, 30mA
Endurance electrical comp: _> 4,000 operating cycles Endurance mechanical comp: _> 20,000 operating cycles
Ultimate short circuit breaking capacity: Curve 1, Curve 2 Ultimate short circuit breaking capacity: 10kA
Rated short circuit breaking capacity: 10kA Rated fault breaking capacity: 10kA
11.5
91
17.7
Features:
Complies to IEC 60947-2
Control: On load
Min service entrance from busbars
Switching and isolating
circuit opening and closing
Direct busbar mount motors
1 2
Remove existing Remove existing QF
QF escutcheon chassis and main switch.
(Remove main switch ONLY
on AVDV model)
3 4
Install new QH main switch Install new QH escutcheon
and chassis kits. (Main switch
NOT required for HPR boards)
Features:
Spacious design affords more useable space
(depth below escutcheon 150mm)
Additional switchboard modules can be added to the top,
bottom and sides for a modular solution
Complies with AS/NZS 3439.3
Enclosure depth:
IP42 degree of protection
(including door) 225mm
Quality 250A, 20kA, 0.25 type tested busbar system
Top and bottom removable gland plates
Features:
Complies with AS/NZS 3439.3
IP66 degree of protection
Spacious250A,
Quality 20kA, 0.25 type tested busbar system
(depth below
design affords more useable space
escutcheon 140mm)
Additional switchboard
Enclosure depth: 225mm (including door)
bottom and sides for a modular
modules can be added to the top,
solution
Removable top and bottom gland plates
Main No of Height Width Depth Part
Switch Poles (mm) (mm) (mm) Number
250A 24 800 580 225 HPRDH24M250
36 1000 580 225 HPRDH36M250
48 1000 580 225 HPRDH48M250
60 1200 580 225 HPRDH60M250
72 1400 580 225 HPRDH72M250
84 1600 580 225 HPRDH84M250
96 1800 580 225 HPRDH96M250
Description Part
Number
250A Main Switch MSHS250ADVDH
Kit for ADVDH,
Description Part
Number
250A Amp Main HS250
Switch 3 Pole
90 Fairbank Rd, Clayton South, VIC 3169 Unit 2, 80 Ebbern St, Darra, QLD, 4076 WP Martin Pty Ltd Electrical Agencies
PO Box 241, Springvale, VIC 3171 PO Box 3240, Darra, QLD, 4076 85 Elizabeth St, Launceston, TAS, 7250 90 Central Avenue, Moonah, TAS, 7009
PHONE +61 3 9590 3555 PHONE +61 7 3279 1833 PHONE +61 3 6331 5545 PHONE +61 3 6273 1855
FAX +61 3 9551 1053 FAX +61 7 3279 1866 FAX +61 3 6331 4256 FAX +61 3 6273 1158
FREE CALL 1800 770 870 FREE CALL 1800 770 870 EMAIL abowen@wpmartin.com.au EMAIL elecag@bigpond.net.au
EMAIL southern@cbi-electric.com.au EMAIL qld@cbi-electric.com.au