Lighting Efficiency

INPUT WATTAGE GUIDE


Please use these wattages when calculating estimated wattage savings for Lighting Efciency rebates, by ConservationWise
from Xcel EnergySM. These estimates gure electricity drawn by the system in an enclosed xture and are taken from exist-
ing test data or calculated for similar lamp/ballast combinations.
This wattage guide is provided to estimate energy savings. Energy savings calculations are estimates and may
vary from actual results.
Fixture wattages may vary slightly between different model numbers & manufacturers.They type of xture
and method of installation will affect the actual system wattage.

Fixture Input Watts (for normal power ballasts)


Fluorescent Lamp Description Number of *Standard Energy Saving Electronic
Lamps Magnetic Magnetic Ballast
Ballast Ballast
T12 Fluorescent Lamps
F15T12 1.5 15W 1 _ 21.5 _
F15T12 1.5 15W 2 _ 41.3 _
F15T12 1.5 15W 3 _ 63.0 _
F20T12 2 20W 1 _ 21.2 _
F20T12 2 20W 2 _ 41.6 _
F20T12 2 20W 3 _ 64.0 _
F20T12 2 20W 4 _ 91.0 _
F24T12 3 24W 1 _ 44.8 _
F24T12 3 24W 2 _ 60.5 _
F25T12 3 25W 1 _ _ 26.7
F25T12 3 25W 2 _ _ 52.4
F25T12 3 25W 3 _ _ 69.7
F25T12 3 25W 4 _ _ 88.4
F30T12 3 30W 1 _ 36.0 32.0
F30T12 3 30W 2 _ 69.0 59.8
F30T12 3 30W 3 _ 113.0 90.0
F30T12 3 30W 4 _ 138.0 _
F30T12 3 25W 1 _ 36.0 28.8
F30T12 3 25W 2 _ 65.0 50.5
F30T12 3 25W 3 _ 103.0 78.0
F30T12 3 25W 4 _ 125.0 _
F40T12 4 40W 1 51 42.0 40.8
F40T12 4 40W 2 88 75.0 74.5
F40T12 4 40W 3 135 141.0 110.0
F40T12 4 40W 4 175 172.0 134.0
F40T12 4 34W 1 48 39.7 34.6
F40T12 4 34W 2 78 65.8 61.6
F40T12 4 34W 3 127 102.2 92.0
*Standard Magnetic ballasts that dont comply with Public Law 100-357 of 1988. These ballasts were no longer
manufactured after January 1, 1990.
Fixture Input Watts (for normal power ballasts)
Fluorescent Lamp Description Number of *Standard Energy Saving Electronic
Lamps Magnetic Magnetic Ballast
Ballast Ballast
F40T12 4 34W 4 156 144.0 119.0
F36T12 3 30W SLIM 1 _ 57.1 _
F36T12 3 30W SLIM 2 _ 77.3 _
F42T12 3.5 35W SLIM 1 _ 57.0 48.0
F42T12 3.5 35W SLIM 2 _ 83.0 73.0
F48T12 4 30W ES SLIM 1 _ 52.0 42.0
F48T12 4 30W ES SLIM 2 _ 80.0 65.0
F48T12 4 40W SLIM 1 _ 60.0 50.0
F48T12 4 40W SLIM 2 _ 98.0 79.3
F60T12 5 50W SLIM 1 _ 73.0 64.5
F60T12 5 50W SLIM 2 _ 113.0 104.0
F72T12 6 57W SLIM 1 _ 74.0 69.8
F72T12 6 57W SLIM 2 _ 119.0 110.8
F84T12 7 65W SLIM 1 _ 88.6 80.0
F84T12 7 65W SLIM 2 _ 147.9 127
F96T12 8 60W ES SLIM 1 _ 76.5 68.7
F96T12 8 60W ES SLIM 2 _ 115.2 108.7
F96T12 8 75W SLIM 1 _ 95.1 84.3
F96T12 8 75W SLIM 2 _ 141.5 134.3
F24T12 HO 2 35W 1 _ 64.0 _
F24T12 HO 2 35W 2 _ 99.0 _
F24T12 HO 2 35W 3 _ 148.0 _
F24T12 HO 2 35W 4 _ 183.4 _
F30T12 HO 2.5 42W 1 _ 67.0 _
F30T12 HO 2.5 42W 2 _ 100.0 _
F36T12 HO 3 50W 1 _ 72.0 _
F36T12 HO 3 50W 2 _ 117 _
F36T12 HO 3 50W 3 _ 165.9 _
F36T12 HO 3 50W 4 _ 211.7 _
F42T12 HO 3.5 50W 1 _ 81.0 _
F42T12 HO 3.5 50W 2 _ 130.0 _
F48T12 HO 4 60W 1 _ 81.9 _
F48T12 HO 4 60W 2 _ 142.2 125.0
F48T12 HO 4 60W 3 _ 203.6 _
F48T12 HO 4 60W 4 _ 262.6 _
F48T12 VHO 4 116W 1 _ 134.0 _
F48T12 VHO 4 116W 2 _ 207.5 _
F48T12 VHO 4 116W 3 _ 311.0 _
F60T12 HO 5 75W 1 _ 102.0 _
2 *Standard Magnetic ballasts that dont comply with Public Law 100-357 of 1988. These ballasts were no longer
manufactured after January 1, 1990.
Fixture Input Watts (for normal power ballasts)
Fluorescent Lamp Description Number of *Standard Energy Saving Electronic
Lamps Magnetic Magnetic Ballast
Ballast Ballast
F60T12 HO 5 75W 2 _ 170.0 116.4
F60T12 HO 5 75W 3 _ 246.0 _
F60T12 HO 5 75W 4 _ 312.0 _
F60T12 VHO 5 138W 1 _ 140.0 _
F60T12 VHO 5 138W 2 _ 246.0 _
F64T12 HO 64 80W 1 _ 104.0 _
F64T12 HO 64 80W 2 _ 175.0 141.0
F64T12 HO 64 80W 3 _ 246.0 _
F64T12 HO 64 80W 4 _ 312.0 _
F72 T12 HO 6 85W 1 _ 106.9.0 _
F72 T12 HO 6 85W 2 _ 189.7 _
F72 T12 HO 6 85W 3 _ 273.6 _
F72 T12 HO 6 85W 4 _ 323.0 _
F72 T12 VHO 6 168W 1 _ 168.6 _
F72 T12 VHO 6 168W 2 _ 314.0 _
F72 T12 VHO 6 168W 3 _ 424.0 _
F84T12 HO 7 100W 1 _ 118.0 _
F84T12 HO 7 100W 2 _ 219.0 190.0
F84T12 HO 7 100W 3 _ 278.0 _
F96 T12 HO 8 110W 1 129.0 133.4 119.0
F96 T12 HO 8 110W 2 230.0 246 207.5
F96 T12 HO 8 95W ES 1 125.0 110.6 _
F96 T12 HO 8 95W ES 2 209.0 208.7 170.0
F96 T12 VHO 8 215W 1 _ 205.4 _
F96 T12 VHO 8 215W 2 _ 326.1 _
F96 T12 VHO 8 215W 3 _ 517.5 _
F96 T12 VHO 8 185W ES 1 _ 196.7 _
F96 T12 VHO 8 185W ES 2 _ 371.1 _
F96 T12 VHO 8 185W ES 3 _ 451.0 _

Fixture Input Watts (for normal power ballasts)


Fluorescent Lamp Description Number of Lamps Energy Saving Electronic Ballast
Magnetic Ballast
T10 Fluorescent Lamps
F40T10 4 40W 1 49.9 41.3
F40T10 4 40W 2 90.6 76.7
F40T10 4 40W 3 141.0 114
*Standard Magnetic ballasts that dont comply with Public Law 100-357 of 1988. These ballasts were no longer
manufactured after January 1, 1990.
3
Fixture Input Watts
(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T8 Fluorescent Lamps
F13T8 1 13W 1 18.3 _
F13T8 1 13W 2 35.6 _
F15T8 1.5 15W 1 20.8 _
F15T8 1.5 15W 2 40.5 _
F17T8 2 17W 1 23.9 18.3
F17T8 2 17W 2 43.9 33.0
F17T8 2 17W 3 64.0 48.1
F17T8 2 17W 4 83.0 59.8
F25T8 3 25W 1 30.2 25.9
F25T8 3 25W 2 57.9 48.1
F25T8 3 25W 3 87.0 68.5
F25T8 3 25W 4 116.0 85.8
F25T8 4 25W 1 _ 26.0
F25T8 4 25W 2 _ 48.0
F25T8 4 25W 3 _ 65.0
F25T8 4 25W 4 _ 79.0
F28T8 4 28W 1 _ 25.0
F28T8 4 28W 2 _ 49.0
F28T8 4 28W 3 _ 72.0
F28T8 4 28W 4 _ 98.0
F30T8 4 30W ES 1 39.6 33.6
F30T8 4 30W ES 2 82.1 58.2
F30T8 4 30W ES 3 _ 80.8
F30T8 4 30W ES 4 _ 99.4
F32T8 4 32W 1 35.1 33.2
F32T8 4 32W 2 68.2 62.0
F32T8 4 32W 3 100.0 86.2
F32T8 4 32W 4 131.0 106.7
F32T8 4 32W 6 200.0 172.0
F32T8 4 32W 8 262.0 214.0
F36T8 4 36W 2 _ 74.0
F40T8 5 40W 1 49.0 41.1
F40T8 5 40W 2 90.6 76.3
F40T8 5 40W 3 131.0 107.7
F40T8 5 40W 4 171.0 116.0
F48T8 HO 4 44W 1 _ 52.5
F48T8 HO 4 44W 2 99.7 _
F60T8 HO 5 55W 1 _ 64.5
4
Fixture Input Watts
(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T8 Fluorescent Lamps
F60T8 HO 5 55W 2 116.0 _
F72T8 6 46W 1 51.7 56.0
F72T8 6 46W 2 97.0 86.0
F72T8 HO 6 66W 1 _ 80.0
F72T8 HO 6 66W 2 136.0 _
F96T8 8 59W 1 75.6 75.3
F96T8 8 59W 2 135.2 124.2
F96T8 8 59W ES 1 _ 62.0
F96T8 8 59W ES 2 _ 101.0
F96T8 HO 8 86W 1 _ 88.0
F96T8 HO 8 86W 2 _ 150.0

Fixture Input Watts


(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T8 U-shape Fluorescent Lamps
F16T8 U 1 23.4 17.0
F16T8 U 2 45.8 29.3
F16T8 U 3 _ 45.6
F16T8 U 4 _ 55.8
F24T8 U 1 32.1 24.3
F24T8 U 2 61.7 45.7
F24T8 U 3 _ 65.0
F24T8 U 4 _ 81.5
F25T8 U 1 33.9 25.0
F25T8 U 2 59.8 49.0
F25T8 U 3 _ 76.0
F31T8 U 1 _ 34.1
F31T8 U 2 _ 63.6
F31T8 U 3 _ 90.1
F31T8 U 4 _ 105.5
F32T8 U 1 37.0 34.5
F32T8 U 2 68.1 65.0
F32T8 U 3 _ 91.7
F32T8 U 4 _ 110.0

5
Super T8 System Input Wattage
Instant Start Ballast Rapid Start Ballast
Low Normal High Low Low Normal
ballast ballast ballast ballast ballast ballast
factor (0.77) factor (0.87) factor (1.15) factor (0.71) factor (0.77) factor (0.88)
1 lamp 25.0 28.0 - 25.0 - 31.0
2 lamps 48.1 54.4 74.2 47.0 48.1 59.9
3 lamps 73.3 82.1 110.6 73.2 74.0 88.0
4 lamps 97.5 108.8 149.4 93.4 97.5 117.3

Fixture Input Watts


(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T5 Fluorescent Lamps
F4T5 6 4W 1 9.2
F4T5 6 4W 2 19.5
F6T5 9 6W 1 9.7
F6T5 9 6W 2 21.2
F8T5 1 8W 1 14.4 10.0
F8T5 1 8W 2 22.7 21.0
F13T5 2 13W 1 15.5 14.0
F13T5 2 13W 2 26.4 25.0
F14T5 2 14W 1 _ 16.2
F14T5 2 14W 2 _ 31.3
F21T5 3 21W 1 _ 25.2
F21T5 3 21W 2 _ 48.9
F28T5 4 28W 1 _ 32.3
F28T5 4 28W 2 _ 64.0
F35T5 5 35W 1 _ 40.3
F35T5 5 35W 2 _ 80.3
F24T5 HO 2 24W 1 _ 28.0
F24T5 HO 2 24W 2 _ 54.4
F39T5HO 3 39W 1 _ 42.4
F39T5HO 3 39W 2 _ 87.5
F54T5HO 4 54W 1 _ 62.5
F54T5HO 4 54W 2 _ 120.3
F54T5HO 4 54W 4 _ 236.0
F80T5HO 5 80W 1 _ 91.0

6
Fixture Input Watts
(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
Circular Fluorescent Lamps
FC9T5, 22W 1 _ 27.3
FC9T5, 22W 2 _ 56.0
FC12T5, 40W 1 _ 43.5
FC12T5, 40W 2 _ 83.5
FC12T5HO, 55W 1 _ 58.5
FC12T5HO, 55W 2 _ 113.0
FC6T9, 20W 1 19.9 _
FC8T9, 22W 1 19.4 _
FC8T9, 22W 2 42.9 _
FC12T9, 32W 1 40.0 _
FC12T9, 32W 2 60.5 _
FC16T9, 40W 1 38.1 _
FC16T9, 40W 2 80.1 _

Fixture Input Watts


(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T5 Twin Tube Fluorescent Lamps
FT18W TT5 1 25.6 _
FT18W TT5 2 50.9 34.0
FT18W TT5 3 62.0 50.0
FT24W TT5 1 31.6 27.6
FT24W TT5 2 67.4 53.5
FT27W TT5 1 30.2 _
FT27W TT5 2 65.67 40.0
FT27W TT5 3 _ 60.0
FT36W TT5 1 51.2 36.8
FT36W TT5 2 85.5 73.7
FT39W TT5 1 53.3 48.0
FT39W TT5 2 87.1 75.0
FT39W TT5 3 82.0 106
FT40W TT5 1 43.2 42.0
FT40W TT5 2 77.3 73.5
FT40W TT5 3 _ 110.0
FT50W TT5 1 _ 57.5
FT50W TT5 2 _ 112.0
FT55W TT5 1 _ 62.0
FT55W TT5 2 _ 120.0
FT80W TT5 1 _ 91.0
77
Fixture Input Watts
(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T2 Miniature Fluorescent Lamps
FM6T2 2 _ 15.0
FM8T2 1 _ 11.0
FM8T2 2 _ 20.0
FM11T2 1 _ 14.0
FM11T2 2 _ 28.0
FM13T2 1 _ 17.0
FM13T2 2 _ 33.0

Fixture Input Watts


(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T4 Compact Fluorescent Lamps
CFT5W/G23 1 9.9 _
CFT7W/G23 1 10.2 _
CFT7W/G23 2 _ 16.0
CFT9W/G23 1 10.4 10.0
CFT9W/G23 2 26.4 20.0
CFQ9W/G23 1 10.2 _
CFQ9W/G23 2 27.8 _
CFQ10W/G24D 1 16.1 _
CFQ13W/G24D 1 17.6 _
CFQ13W/GX23 1 16.0 14.0
CFQ13W/GX23 2 34.6 25.0
CFT13W/GX23 1 15.9 _
CFT13W/GX23 2 34.6 _
CFTR13W 1 _ 14.0
CFTR13W 2 _ 25.0
CFTR18W 1 _ 16.0
CFQ18W 1 _ 16.0
CFQ18W/G24D 1 24.0 _
CFQ18W/G24D 2 43.5 _
CFQ20W/GX32D 1 25.3 _
CF24T5DF 1 _ 28.0
CF24T5DF 2 _ 54.0
CFTR26W 1 _ 26.0
CFQ26W/G24D 1 30.5 26.0

8
Fixture Input Watts
(for normal power ballasts)
Fluorescent Lamp Number of Lamps Energy Saving Electronic
Description Magnetic Ballast Ballast
T4 Compact Fluorescent Lamps
CFS38W 1 _ 31.0
CFQ26W/G24D 2 52.4 _
CFQ27W/GX32D 1 31.7 _
CF36T5DF 1 _ 35.0
CF36T5DF 2 _ 73.0
CFS38W 1 _ 31.0

Fixture Input Watts


(for normal power ballasts)
Mercury Vapor Lamp Number of Lamps Magnetic Ballast
Description
50W Med. Base 1 75.0
75W Med. Base 1 95.0
100W Med. Base 1 125.0
175W Med. Base 1 205.0
175W Mogul Base 1 205.0
250W Mogul Base 1 285.0
400W Mogul Base 1 454.0
400W Mogul Base 2 880.0
1,000W Mogul Base 1 1075.0

High Pressure Sodium Lamp


High Pressure Sodium Number of Lamps Magnetic Ballast
Lamp Description
35W Med. Base 1 45.0
50W Med. Base 1 64.0
70W Med. Base 1 91.0
100W Med. Base 1 128.0
150W Med. Base 1 188.0
100W Mogul Base 1 130.0
150W Mogul Base 1 188.0
200W Mogul Base 1 241.0
250W Mogul Base 1 295.0
310W Mogul Base 1 365.0
400W Mogul Base 1 465.0
600W Mogul Base 1 665.0
750W Mogul Base 1 840.0
1000W Mogul Base 1 1100.0

9
9
Fixture Input Watts (for normal power ballasts)

Metal Halide Lamp Number of Lamps Magnetic Ballast


Description 1-800-481-4700
32W Med. Base 1 38.0 www.xcelenergy.com
35W/39W Med. Base 1 52.0 2004 Xcel Energy Inc.
Xcel Energy is a trademark
50W Med. Base 1 70.0 of Xcel Energy Inc.
70W Med. Base 1 93.0 Northern States Power
100W Med. Base 1 129.0 Company d/b/a/ Xcel Energy
150W Med. Base 1 185.0 04-06-306 07/04 CSS #0293

70W Double Ended 1 95.0


100W Double Ended 1 130.0
150W Double Ended 1 185.0
175W Mogul Base 1 210.0
250W Mogul Base 1 295.0
400W Mogul Base 1 460.0
400W Mogul Base 2 890.0
1000W Mogul Base 1 1080.0
1500W Mogul Base 1 1610.0
1650W Mogul Base 1 1765.0
2000W Mogul Base 1 2140.0

Fixture Input Watts (for normal power ballasts)


Pulse Start Metal Halide Lamp Number of Magnetic Energy Saving Magnetic Ballast
Description Lamps Ballast (CWA) (Reactor)
50W Med. Base 1 72.0 60.0
70W Med/Mogul Base 1 90.0 85.0
100W Med/Mogul Base 1 128.0 118.0
150W Med/Mogul Base 1 190.0 170.0
175W Med/Mogul Base 1 208.0 189.0
200W Med/Mogul Base 1 232.0 215.0
250W Med/Mogul Base 1 290.0 275.0
320W Med/Mogul Base 1 368.0 349.0
350W Med/Mogul Base 1 400.0 380.0
400W Med/Mogul Base 1 452.0 435.0
450W Med/Mogul Base 1 506.0 485.0
750W Med/Mogul Base 1 812.0 -
1000W Med/Mogul Base 1 1080.0 -