Side By Side

Display LED Buzzer Fault


The Pocket Guide
D Fdg ON ON Damper stuck or to Fault Codes
doesnt connect. By Technicians, for Technicians
C Fdg ON ON Fridge sensor failure.
C Fzr ON ON Freezer sensor failure.
CF Fzr ON ON Communication failure REFRIGERATION
between main board
and user interface. COOKING
"--" Fzr ON ON Temp in freezer WASHING
higher than 11
(temp safety limit) DISHWASHING
"-7" or other values on Fzr AND
ON ON Black out over tempera SIDE BY SIDES
ture alarm engaged.

Ovens
Fault Defect Intervention
F01 Open or short Replace temp Probe
circuit of temp probe.
F02 Overheating of Replace Capricorn
oven.
F03 Capricorn not Replace Capricorn
properly configured.
F04 WISP protocol Replace Capricorn or Whirlpool Uk Ltd
not working. Scale. 209 Purley Way
Croydon
CR9 4RY
Induction Hobs
Code Fault Tel: +4420 8649 5000
F Sensor Fax: +4420 8649 5159
F3 Config error
F12 Communication error Compiled and Edited by:
F22 Key sensitivity error
Touch Control Hob Peter Martins and Adam Bigden
Code Fault Whirlpool Technical Team
F3 Config error
F12 WISP communication error Email: adam_bigden@whirlpool.com
F22 Key sensitivity error peter_martins@whirlpool.com Every home, everywhere...with Pride,
Passion, Performance!
Dishwasher Steam Chef Smart Gas
Code Fault I Code Fault Code Fault
F01 on/off valve stuck open.
F0 Sensor Failure F0 Incorrect value of cavity sensor. F02 Communication problem.
F1 NTC Failure F1 Incorrect value of cavity sensor. F03 Control board problem.
F2 Water Leakage F2 Incorrect value of Food Probe. F04 User interface problem.
F3 Heating system failure F3 Incorrect value of climate sensor. F05 Continuous E2 prom reset.
F4 Draining failure F4 Incorrect current value from flap motor.
F5 Rotor blocked F5 Unable to backup EEPROM. F11 Burner 1 open circuit on thermocouple.
F6 Water tap closed F7 No, or slow increase of water F21 Burner 2 open circuit on thermocouple.
F7 Flow meter failure temperature. F31 Burner 3 open circuit on thermocouple.
F8 Water level failure F8 Level sensor detects water after F41 Burner 4 open circuit on thermocouple.
F9 Continuous water inlet draining. F12 Burner 1 PWM valve stuck open.
FA Optical water indicator F9 No or slow increase of climate F22 Burner 2 PWM valve stuck open.
FB Motorised diverter valve temperature. F32 Burner 3 PWM valve stuck open.
FC Water hardness sensor failure No Indication Oven does not heat. F42 Burner 4 PWM valve stuck open.

WASHING M/C Microwave Ovens Washer/Dryers


Code Fault Code Fault Code Fault
Open Check the closure of the porthole and
FH No water inlet ERR0 Convection temperature fault, not relating indicator in case it is open.
FA Aquastop failure connected or short circuit
E01 Display shows the safety device for
FP Drain failure ERR1 Short circuit in the MW relay water loss has tripped.
F5 NTC failure ERR3 Key error when one of the buttons is
E02 Overflow engaged (only out of a
F6 Tachometer failure (no motor pressed for more than 1 minute
washing program)
movement detected) ERR6 Weight sensor calibration has not
E04 Water temperature probe in short circuit
F7 Triac short circuit detection been performed
or interrupted.
F8 Heating element, open circuit ERR7 Humidity sensor is defective or has not E05 As water is being loaded, if the pressure
F9 Overflow failure been connected switch does not reach the full level
F10 Motor control unit (thermal) ERR8 Impossible to write to E2 Prom within the first 6, problem displayed.
F11 Communication failure ERR9 Options have not been set E06 If during water drain, the empty level is
F12 Heating element short circuit ERR A No wheel detected on weight sensor not reached in 10, problem displayed.
F13 Dispenser circuit error ERR B No pulses from the weight sensor or
E10 Motor over-current.
F14 EEPROM Failure <4267Hz
E11 Problem of motor control triac (short
F15 Motor control unit error ERR C Fuzzy temperature sensor fault not 19- circuit or interrupted).
F16 Control failure (control unit) 41C
E12 Indication for tachyometry malfunction.
F18 Control failure (control unit) ERR D NTC overheat protection on the E13 Malfunctioning door block PTC.
F20 Control failure (control unit) magnetron is faulty (not connected or
E14 Dryer temperature probe in short circuit
F21 Control failure (user board) short circuit)
or interrupted.
F22 Control failure (user board) E- Communication problem between inter
FDL Door lock error face board and mother board.
FDU Door unlock error
E- Board hardware problem.