Você está na página 1de 4

Thermo Scientific RADSafe Certified Services

Configurable services tailored to your specific needs


Select from a wide variety of service products to maximize the
productivity of your assets while managing the high cost on unplanned
maintenance and repair.
Performance plans for customers who need standard service
responses Accurate.
Durable.
Essential plans for when rapid service response and uptime are
business priorities

Essential.
Configure your extended warranty, preventative maintenance, calibration
and commissioning and start up services plan and enjoy peach of mind.
To learn more visit www.thermofisher.com/radsafe

Spare Parts
Looking for spare parts for this instrument?
Visit our spare parts website at www.analyticalinstrumentparts.com

Thermo Scientific Harshaw TLD Materials and Dosimeters

Find out more at thermofisher.com/dosimetry

2016 Thermo Fisher Scientific Inc. All rights reserved. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
Not all products are available in all countries. Please consult your local sales representatives for details. BR-RMSI-TLD-0616
Lithium Fluoride based TLD materials are near tissue-equivalent
Thermo Scientific and provide excellent energy response, eliminating the need
Harshaw TLD Materials and Dosimeters for extensive mathematical computations to determine dose,
improving overall accuracy and reducing the potential for
Thermo Scientific Harshaw TLD Materials are available in costly errors. Additionally, Lithium Fluoride based materials are
a wide range of formats to meet any dosimetry need, from not sensitive to light, enabling added flexibility in dosimeter
research, clinical and industrial applications to personnel and handling and processing for improved productivity and process
environmental monitoring. Harshaw Lithium Fluoride based efficiency.
materials can be used for gamma, beta and neutron monitoring,
Dosimetry Available
with an available high sensitivity, no-fade, Mg, Cu, P option Material Type
Application
Linear Range Fading
Forms*
for low dose or long-wear applications. Additional materials are TLD-100
Research, Clinical Chips, MicroCube,
(Li natural)
available for extended dose range coverage. Lithium Fluoride TLD-600 <20% in 3 months
Square Rod, Rod,
Neutron 10 Gy - 1 Gy Unsorted Chips,
LiF:Mg,Ti (Li-6 isotope) <5% in 3 months corrected
Powder, Pelletized
TLD-700 Chip, Pelletized Disk
Gamma, Beta
Harshaw TLD Dosimeters are available in un-mounted forms (rods, chips, powders, micro-cubes (Li-7 isotope)
and pelletized disks), as well as fixed into multi-element aluminum cards, extremity dosimeters or TLD-100H Environmental,
mounted singly on a Kapton substrate, to meet your exact application need. (Li natural) Personnel, Extremity
Negligible in 3 months Pelletized Chip,
Lithium Fluoride TLD-600H
Neutron 1 Gy - 10 Gy <5% up to 2 years Pelletized Disk,
A Proven History LiF:Mg,Cu,P (Li-6 isotope) Powder
TLD-700H Gamma, Beta,
Manufactured in ISO9001 Certified factory for over 40 years
(Li-7 isotope) Environmental
Strictly controlled material quality and performance Calcium Fluoride
10% in 1st 24 hr
Dysprosium, TLD-200 Environmental 0.1 Gy - 10 Gy Chip
100% quality controlled in a multi-step QC process CaF2:Dy 16% total in 2 weeks
Calcium Fluoride
Proven to last, with cards warrantied up to 500 reads, reducing the total cost of ownership of a Manganese, TLD-400
Environmental and
0.1 Gy - 100 Gy
8% in 1st 24 hr
Chip
High Dose 12% total in 2 weeks
dosimetry system. CaF2:Mn
*Visit thermofisher.com or contact customer service for exact specifications and ordering information for available
material forms.

Response Curves (tissue equivalency for LiF, competing material).

3 4

* LiF:Mg,Ti,Main dosimetric peaks (4+5), all fade normalized to 2 days


Multi-element Card Dosimeters for Harshaw TLD offers extremity
Personnel and Environmental Monitoring dosimeters in two different formats
Harshaw TLD Multi-element card dosimeters are Dose algorithms are also available for our most
available in a variety of configurations for personnel common multi-element card/holder configurations ThermoScientific EXT-RAD Thermo Scientific DXT-RAD
or environmental monitoring of shallow (Hp(0.07)), for use in calculating dose from a card readout. Extremity Dosimeter Extremity Dosimeter
deep (Hp(10)) and lens of eye (Hp(3) dose. Harshaw dose algorithms were developed by
irradiating hundreds of dosimeters to a wide variety Available in single or double element chipstrates with Disk dosimeter, containing an integrated circular
Materials in the form of chips or pelletized disks are an attached barcode barcode to ensure unbroken chain of custody,
of radiation types and energies, simulating hundreds
capsulated in Teflon and mounted in an aluminum
or thousands of mixed fields, and using a neural Can be worn in a ring, finger cot, wristband or More durable, smaller and easier to wear than
card for extended durability. Different materials are
network technique, to produce intelligent algorithms headband for eye dosimetry, depending on need. available alternatives
available for gamma, beta and neutron monitoring.
ensuring accurate calculation of dose. Neural Can be worn in comfortable, adjustable, disposable
Each card is uniquely barcoded and available
network algorithms are more reliable than competing
in different colors as an aid to recognition and finger rings, wrist bands or headbands for eye
branching algorithms which have the potential for
categorization of issuance or wear periods. Multiple dosimetry.
costly mathematical errors incorrectly assigning
tamper-resistant holders are offered containing
dose.
optimized filtration for energy discrimination
appropriate for each card configuration, with
attachments to the lapel and/or belt to meet the
wearer needs.

Time, Temperature Profile Typical TLD Card Configuration Extremity Monitoring


Harshaw TLD extremity dosimeters are available in Harshaw TLD extremity dosimeters can be
Position/Element 1: Position/Element 2: a variety of materials and with a multiple filtration processed using any Harshaw hot gas TLD card
Low Energy Photon Deep dose (Hp(10)) alternatives, enabling monitoring for gamma, beta reader (Models 4500, 6600 Plus and 8800 Plus)
Discrimination and Lens 1000 mg/cm2 or neutrons as needed. Harshaw TLD extremity using available extremity dosimeter carrier cards.
dose (Hp(3)) filtration dosimeters can be worn on the fingers, wrists, or Automatic card readers equipped with an optional
~300 mg/cm2 filtration head for monitoring dose to the lens of eye. They integrated barcode reader will automatically
are sterilizable for maintaining hygienic conditions associate the TL response from the individually
and uniquely barcoded for chain of custody and barcoded extremity dosimeters for maintaining an
Position/Element 3:
Position/Element 4: data integrity. unbroken chain of custody and ensuring complete
Shallow dose
Mid-Energy Photon dosimeter data tracking.
(Hp(0.07))
Discrimination and
~17 mg/cm2
Neutron dose
filtration
Li-6 isotope
Various filtration

5 6
Specification/Ordering Information Not all models are shown, refer to thermofisher.
com or contact customer service for a complete model listing.

Multi-Element TLD Cards


Personnel Dosimeters DXT-RAD Specifications and Ordering Information
Obtainable Dose Equivalent DXT-RAD Dosimeter
Radiation Types Measured
Measurements
TLD Card Material Part Number Mass Density TLD Material Type Application Useful Range Fading
Model
Model
Gamma, LiF:Mg,Ti Card LiF:Mg,Cu,P Card Algorithm TLD-100H Photon, Beta (3.3 mg/
Holder Deep Shallow Neutron 0.20 mSv 10 Sv
X-Ray Beta Neutron Lens Short Description/ Short Description/ DXT-107H 26995 7 mg/cm2 LiF:Mg,Cu,P (Natural cm2 cap) Neutron- Negligible
Hp(10) Hp(0.07) Deep (20 mrem - 1000 rem)
(Photons) Series Part Number Series Part Number Lithium Fluoride) Free Environment
8806 X X X X 6776 / TLDCARD-43C 28103 TLD-700H Photon, Beta (3.3
0.20 mSv 10 Sv
0110 / TLDCARD-21C DXT-707H 26998 7 mg/cm2 LiF:Mg,Cu,P mg/cm2 cap) Neutron Negligible
(20 mrem - 1000 rem)
X 1110 / TLDCARD-31C 28514 (Lithium-7 Fluoride) Environment
8814 X X X X
TLD-100 Photon
X X X 7776 / TLDCARD-43C 28463 0.20 mSv 10 Sv 5%/yr at 20 C
DXT-100 26994 100 mg/cm2 LiF:Mg,Ti (Natural Neutron-Free
(20 mrem - 1000 rem) with anneal
0110 / TLDCARD-21C Lithium Fluoride) Environment
8825 X X X X X 1110 / TLDCARD-31C 28514 Photon, Neutron
TLD-600
Used with DXT- 0.20 mSv 10 Sv 5%/yr at 20 C
X X X 7776 / TLDCARD-43C 28464 DXT-600 26996 100 mg/cm2 LiF:Mg,Ti
700 For Neutron (20 mrem - 1000 rem) with anneal
0110H / TLDCARD-25P (Lithium-6 Fluoride)
Measurements
8840 X X X X X 1110H / TLDCARD-35P TLD-700
Photon 0.20 mSv 10 Sv 5%/yr at 20 C
DXT-700 26997 100 mg/cm2 LiF:Mg,Ti
X X X 7776H / TLDCARD-47P 28132 Neutron Environment (20 mrem - 1000 rem) with anneal
(Lithium-7 Fluoride)
0110H / TLDCARD-25P
8850 X X X X X 1110H / TLDCARD-35P
X X X 7776H / TLDCARD-47P COMS000191
Caps for the DXT-RAD Extremity Dosimeter
Environmental Dosimeters Part Number Filtration Application
Obtainable Dose 28573 3.3 mg/cm 2
Photon, Beta, Neutron
Radiation Types Measured TLD Card Material
Equivalent Measurements
Model 28908 3.3 mg/cm2 Photon, Beta, Neutron (designed for use with DXT-707H-2 dosimeter)
Gamma, LiF:Mg,Cu,P Card Algorithm Comments
Holder
X-Ray Beta Neutron Ambient Directional Short Description/ 500597 42 mg/cm 2
Photon, Neutron
(Photons) Series Part Number
0110H / TLDCARD-25P
0770H / TLDCARD-27P For environments with neutrons
8855 X X X X
1111H / TLDCARD-45P 28547
7777H / TLDCARD-47P 28547 For environments with neutrons
Options and Accessories
Extremity Dosimeters Etched Barcodes (available on Multi-Element Cards)
Manual Filter-Holder Openers
EXT-RAD Specifications and Ordering Information
Model 8866 Automatic Holder Opener
EXT-RAD Dosimeter Mass Density
Part Number TLD Material Type Application Useful Range Carrier Cards (EXT-RAD, DXT-RAD)
Model (mg/cm2)
TLD-100H
Photon, Beta 0.20 mSv 10 Sv DXT-RAD Ring and Cap Manual Loader/Unloader Station
XD-107H 26975 7 LiF:Mg,Cu,P (Natural
Lithium Fluoride)
Neutron-Free Environment (20 mrem - 1000 rem) Manual DXT-RAD Carrier Card Loader/Unloader
TLD-700H
Photon, Beta 0.20 mSv 10 Sv
Vacuum Tweezers (115 VAC/220 VAC)
XD-707H 26978 7 LiF:Mg,Cu,P (Lithium-7
Fluoride)
Neutron Environment (20 mrem - 1000 rem) External Ringlet Bar Code Reader and Software for DXT-RAD
TLD-100 EXT-RAD Pouch Impulse Heat Sealer Assembly
Photon 0.20 mSv 1 Sv
XD-100 26974 100 LiF:Mg,Ti (Natural Lithium
Neutron-Free Environment (20 mrem - 100 rem)
Fluoride)

Você também pode gostar