Escolar Documentos
Profissional Documentos
Cultura Documentos
QUINTESSENZA INTERNAZIONALE
QUINTESSENZA EDIZIONI S.r.l. - Via Ciro Menotti 65 - 20017 Rho (Mi) - Sped. in abb. post. D.L. 353/2003 (conv. in L. 27/02/04 n. 46) art. 1 comma 1, DCB - Milano
SETTEMBRE-OTTOBRE 2008 A N N O 2 4
c i a l e
Spe o l o g i a
p l a n t
im
2008
N U M E R O 5bis
MegaGenOleone_110-122_GB 14-01-2009 16:07 Pagina 110
MegaGenOleone_110-122_GB 14-01-2009 16:07 Pagina 111
QUINTESSENZA INTERNAZIONALE
The increased use of short dental implants is an emerging trend in the literature today. The aim of this study is to assess a number of articles to be able
to draw conclusions for our own day to day clinical use. Twenty patients were selected and 32 implants were placed in both maxillary and mandibular
bone. Single crowns or part bridges were the planned prostheses. The implant survival rate was about 97%. A single implant, placed in the maxillary tuberos-
ity area, failed during the second stage surgery.
INTRODUCTION (surgically driven implantology) based on os- compensated for by a concommitant increase
seo-integration and the use of smooth-surface in diameter, in many cases reaching a surface
Beginning with the pioneer work of Bråne- “machined” implants. Since then technologi- available for osseo-integration that is compara-
mark, one of the fundamental dogmas of im- cal development supported by research and ble to standard implants. A standard implant
plantology has been the placement of the clinical activity have brought about continuous of 10 mm in length and 4 mm in diameter pro-
longest possible dental implants possible in re- changes in indications and have extended the vides a surfaces area of about 152 mm2 whilst
lation to the amount of available bone. This was boundaries of implant-prosthetic therapy. an implant 6 mm in length and 5 mm in diam-
the beginning of the phase of implantology In particular, surface treatments, modifica- eter provides a surface of about 150 mm2. From
tions to the implant design and surgical tech- a biomechanical point of view, the increase in
* PhD research student in Experimental Periodontology,
niques have allowed a progressive use of im- the implant diameter also determines a parallel
University of Milano-Bicocca. plants of decreasing length1. Back in 1998, ten increase in the size and rigidity of the entire sys-
** Specialist in Oral Surgery, Contract Professor in Prostheses Bruggenkate published the results of a multi- tem’s components. The size of the abutment,
Prosthetics, University of Milano-Bicocca. centre study on the use of 6mm implants. Lat- the connection and abutment screw all increase
*** Independent Professional. President of the MIR Dental Hospital er, Deporter reported on the results of short thereby reducing the incidence of unscrewing
Daegu, Korea.
implants with modified porous surface implants and/or fractures at this level. Considering the
**** PhD research graduate in Experimental Periodontology, in both the maxillary bone and in mandibular fact that these implants are essentially used in
University of Milano-Bicocca.
bone2-5. In the recent literature, the use of “short the posterior regions, the notable stress from
***** Head of the Department of Neuro-sciences and Biomedical
implants” with a minimum length of 5mm and cyclical fatigue to which the mechanical compo-
Technologies, University of Milano-Bicocca.
with wide diameters (wide diameter implants) is nents are subjected can be addressed.
Address for correspondence: now emerging6-25. The minimum requirement Finally, the increased diameter of the im-
Matteo Sartori
of 10 mm of length for an implant to be suc- plant platform allows crowns to be created with
Università degli Studi di Milano-Bicocca, Via Cadore 48 – Monza (MI)
Tel. +39 2 96720909 - Fax. +39 2 96328554
cessful has now been surpassed6. In the case an adequate emergence profile that is closer to
E-mail: matteosartori@sapol.it of short implants, the reduction in length is the normal size of a multi-rooted tooth.
QUINTESSENZA INTERNAZIONALE
M. Sar tori, R. Monguzzi, S. Longoni, K. B. Park, M. Mingardi, M. Baldoni
When a standard diameter implant is used 3. Clinical situations in which a partial failure of body. A short implant can only guarantee per-
to replace the wide mesio-distal space left by tissue regeneration has occurred. formances that are comparable to standard
the loss of a molar, the emergence profile of the In all cases it is necessary to remember and length and diameter implants if they have a mod-
crown must be modelled following unnatural therefore warn the patient that prosthetic reha- ified, larger surface than a “machined” surface
profiles, mediating between two opposing clin- bilitation on short implants often creates longer implant1.
ical situations: either a linear profile that direct- crowns, which will therefore appear longer than
ly joins the narrow implant platform to the mar- the natural adjacent teeth. Internal connection
ginal crest, leaving a wide, triangular interprox- In most case internal connection short im-
imal space that is uncomfortable for the pa- plants are preferred to the use of external con-
tient, or a profile that tries to fill in the interprox- nection implants. Internal connection means
imal space as well as possible, progressing INDICATIONS FOR THE USE the surface treatment can be extended to in-
first horizontally and then vertically. Another OF SHORT IMPLANTS clude the platform, up to the external perimeter
option is to use two standard implants that are of the connection area. This results in osseo-in-
restored with a single crown. Often however The use of short implants has allowed rapid tegration on the upper surface of the implant
the space available is too much for a single im- rehabilitation of partial edentulism in patients body and once healing is completed, the im-
plant and too small for two implants. In both the with healing times that are comparable with plant will be locked inside a closed bone struc-
case of an excess cervical prosthetic profile those of standard implants with modified sur- ture (apical part, lateral walls and upper por-
and in the positioning of two implants, profes- faces i.e. two months in the mandible and three tion) that effectively combats lateral stress.
sional and home hygiene maintenance will be months in the maxilla.
difficult and probably compromised. Of course, to obtain success in using short Platform switching
In the past, the wide fixture was essentially implants, some rules should be observed. The use of abutments with a reduced diam-
designed and used as a “rescue implant”, as an eter base compared to the diameter of the im-
emergency solution if it was necessary to make Increase in diameter plant platform allows horizontal space to be
the implant site oval in poor quality bone (type Short implants are characterised by wide di- gained, in order to manage biological width, re-
IV) or if failed standard implants had to be re- ameters to compensate for the reduction in length ducing the loss of vertical bone in the ridge
placed immediately7. Nowadaysthe indications and to present an extensive overall surface for os- area27.
for the use of short implants have increased: seo-integration. The recommendation is to
1. Patient’s general health linked to age, pres- choose an implant with the widest possible diam- Increase in number of implants
ence of systemic pathologies, use of phar- eter in relation to the tooth to be rehabilitated and If short implants are used, it is preferable to
maceuticals, presence of local oral condi- the residual bone available. The presence of at increase the number of implants, inserting one
tions preventing advanced surgical tech- least 1 mm of bone around the implant is need- for each tooth to be restored, thereby avoiding
niques for the vertical regeneration of ed to ensure adequate blood supply of the resid- bridges with intermediate elements6.
mandibular bone tissue or the lifting of the ual bone that supports the implant, thus avoiding
maxillary sinus. the undesired phenomena of resorption26. Splinting of implants
2. To avoid complex regenerative surgery with Splinting of implants is also recommended
a possible increase in early or delayed com- Surface treatment i.e. by planning crowns that are joined together
plications. Modern modified implant surfaces allow the to reduce the effect of lateral stress6.
correct stability of the coagulum on the implant
QUINTESSENZA INTERNAZIONALE
M. Sar tori, R. Monguzzi, S. Longoni, K. B. Park, M. Mingardi, M. Baldoni
QUINTESSENZA INTERNAZIONALE
M. Sar tori, R. Monguzzi, S. Longoni, K. B. Park, M. Mingardi, M. Baldoni
Fig. 5 Insertion of implant: diameter 6 mm and length 7 mm. Fig. 6 View of soft tissues before prosthesization. Fig. 7 Check-up endoral radiography: follow-up at
13 months.
Fig. 8 Preparation of implant bed using a trephine cutter. Fig. 9 Insertion of implant: diameter 6 mm and length 7 mm. Fig. 10 Final prosthesis: follow-up at 8 months.
QUINTESSENZA INTERNAZIONALE
M. Sar tori, R. Monguzzi, S. Longoni, K. B. Park, M. Mingardi, M. Baldoni
Fig. 11 Check-up endo-oral radiography: follow- Fig. 12 Surgical phase: removal of a fractured standard Fig. 13 Revision of implant bed using a correction bur.
up at 8 months. implant in the mandible.
QUINTESSENZA INTERNAZIONALE
M. Sar tori, R. Monguzzi, S. Longoni, K. B. Park, M. Mingardi, M. Baldoni
QUINTESSENZA INTERNAZIONALE
The option of immediately loading our implant fixtures significantly simplifies the aesthetic and functional solution for patients, in particular when the an-
terior region is compromised. This article presents five cases of immediate loading for the replacement of four periodontally compromised mandibular in-
cisors, carried out using Intermezzo® (Megagen Co, Ltd, South Korea) one-piece implants.
INTRODUCTION allows a rapid return to normal social life and in- MATERIALS AND METHODS
teractions for our patients. For this reason im-
The successful resolution of aesthetic and mediate loading protocols in the aesthetic area The patients, three females and two males,
functional problems, caused by the loss of are becoming an increasing part of daily den- with an average age of 52.3 years, non-smok-
mandibular incisors due to periodontal disease, tal practice, reducing the number of surgical op- ers, without parafunctional activity and with a
by successful combined prosthodontic and im- erations, treatment time and biological costs stable occlusion, presented with a previous his-
mediate loaded implant treatment modalities, in appropriate cases1-9. tory of periodontal disease. In two cases they
Five cases of immediate loading and restora- presented with a fractured splint (Fig. 1) used to
tion of implants for patients ,who presented try and solve the aesthetic and functional prob-
* Specialist in Oral Surgery, Contract Professor in Prostheses,
University of Milano-Bicocca.
with periodontal disease, are presented here. lem and in three cases presented with severe
These patients all had periodontal pockets with mobility of the four incisors (Fig. 2). Once the
** PhD research student in Experimental Periodontology,
University of Milano-Bicocca. depths ranging from 7 to 11 mm as well as patients’ clinical history and informed consent
*** Independent Professional. President of the MIR Dental
type II-III mobility of their inferior incisors. “One had been gathered, a clinical examination and
Hospital Daegu, Korea. piece” Intermezzo® (Megagen Co, Ltd, South orthopantomograph (Figures 3 and 4) were
**** Contract Professor of special odontostomatological anatomy, Korea) implants with transmucosal healing carried out and impressions, bite registration
University of Milano-Bicocca. abutments were used. This type of implant was and facial arch were recorded for preparation of
***** Head of the Department of Neuro-sciences and Biomedical chosen as they have a narrow abutment and an articulator models with average values. The in-
Technologies, University of Milano-Bicocca.
emergence profile which aid aesthetics for the sertion of 2 Intermezzo® (Megagen Co, Ltd,
inferior incisor group. In addition, the possibili- South Korea) implants, diameter 3.10 mm and
Address for correspondence: ty of changing the inclination of the abutment 13 mm in length were then planned. In partic-
Salvatore Longoni
during the surgical phase aided the correct ular, they were positioned in the area of teeth 32
Università degli Studi di Milano-Bicocca, Via Cadore 48 – Monza (MI)
Tel. +39 2 96720909 - Fax.+39 2 96328554
placing of the prosthesis and its subsequent and 42, with planning for two intermediate units.
E-mail: salvatorelongoni@sapol.it restoration. Prior to surgery, a dental laboratory was asked
QUINTESSENZA INTERNAZIONALE
S. Longoni, M. Sar tori, K. B. Park, A . Baldini, M. Baldoni
Fig. 1 Patient (I01) with fractured anterior inferior splinting. Fig. 2 Patient (I03) with severe mobility of inferior incisors. Fig. 3 Initial Ortopantomography (Items I01).
Fig. 4 Initial Ortopantomography (Items I03). Fig. 5 Use of countersink to determine the correct place- Fig. 6 Insertion of Intermezzo® (Megagen Co, Ltd,
ment of the implant neck. South Korea) one-piece implant, diameter 3.10 mm
and 13 mm in length.
to create a surgical stent and a shelled tempo- of the soft tissues. The implant sites at the lat- working on the abutment, not using a bur, but
rary bridge prosthesis that was to be relined eral incisor site were then prepared according by bending the abutment with a purpose-made
and cemented during the procedure. to the protocol with a lance bur, followed by a hand-drive instrument, exploiting the design of
Following the administration of local anaes- calibrated bur with a diameter of 1.8 mm, a the implant neck. Plastic “comfort caps” were
thesia with Articaine containing adrenaline 4% countersink bur suited to the diameter and the then placed on the abutments and the tempo-
1:100,000 (Ubistesin 3M ESPE, Seefeld, Ger- shoulder of the implant (Fig. 5) and then a cal- rary prostheses were relined in the patients’
many), flaps were created using a intrasulcular ibrated cutter bur with a diameter of 2.6 mm. mouth with cold resin (Sintodent s.r.l., Rome)
incision; the teeth were removed in the least The implants were inserted (figures 6 and 7) (Figures 8 and 9). The space between the plas-
traumatic way possible, limiting the separation and, if necessary, the axis was corrected by tic cap and the resin temporary prosthesis was
QUINTESSENZA INTERNAZIONALE
S. Longoni, M. Sar tori, K. B. Park, A . Baldini, M. Baldoni
Fig. 7 Inserted implants: the axis of the abutments Fig. 8 Positioning of plastic caps on abutment. Fig. 9 Relining of temporary prosthesis with cold resin on
was changed to obtain easy insertion of the pros- plastic caps.
thesis.
Fig. 10 Removal of temporary prosthesis after Fig. 11 The marginal gap is filled with fluid composite and Fig. 12 Intraoral view of bridge just cemented (Items. I01).
relining. the ovate pontics are created.
filled with a fluid composite (Axia Fluid, Dental- open flaps, in order to check and remove ex- and the patients were given appropriate post-
ica Spa, Milan), while ovate pontics were creat- cess cement. The papillae were then sutured operative instructions. The patients followed a
ed on the intermediate elements (Figures 10 using simple sutures with Vicryl Rapid 4-0 liquid diet for the first week, then a semi-solid
and 11) penetrating 2 mm inside the post-ex- (Ethicon, Johnson & Johnson, Brussels, Bel- one and hard foods were avoided until after
traction sockets of the two central incisors. The gium) (Figure 12). the fourth week. Use of the anterior teeth had
temporary prosthesis was then finished and The occlusion was then adjusted, leaving the to be limited for the same period.
polished in the laboratory and then cemented temporary prostheses completely free in protru- The sutures were removed at 10 days and
with a non-eugenol temporary cement (Temp sion and lateral movements. Radiographs were follow-ups were carried out at 20, 30 and 60
Bond NE, Kerr Italia SpA, Scafati SA) leaving taken post-surgery to check results (Figure 13) days from loading. The permanent prosthesis
QUINTESSENZA INTERNAZIONALE
S. Longoni, M. Sar tori, K. B. Park, A . Baldini, M. Baldoni
Fig. 13 Check-up Ortopantomography (Items I01). Fig. 14 CAD design phase of zirconium structure. Fig. 15 View of prosthesis already positioned
(Items. I01).
was then completed at a later date. In all cases tion of soft tissues (Gingifast, Zhermack, Badia RESULTS
there was no need to file down the abutments Polesine). A scan was carried out with similar
in the mouth and the impression procedure models and the structure was modelled with the During the short observation period of about
was therefore simplified. The final impression use of a specific software (Zeno® Tec System, eight months on average, no changes in the
was taken using a polyether material (Im- Wieland Dental & Technik, Germany) (Fig. 14). quality or quantity of the peri-implant tissues
pregum, 3M Espe, Seefeld, Germany) and The final crowns were made with structure in zir- were observed (Figures 16 and 18). The method
plastic impression caps joined with resin (Piku- conium oxide and ceramic and were cemented proved to be simple and predictable with great
plast, Bredent, Senden, Germany). The master with a glass ionomer cement (Ketac Cem ra- satisfaction for the patients, as their aesthetic
model obtained in this way included the duplica- diopaque, 3M Espe, Seefeld, Germany). and functional problems were solved immedi-
QUINTESSENZA INTERNAZIONALE
S. Longoni, M. Sar tori, K. B. Park, A . Baldini, M. Baldoni
ately from the first session. In particular, the re- marginal seal of the temporary prostheses and 4. Malo P, Rangert B, Dvarsater L. Immediate function of
transfer of the implant position quickly. Brånemark implants in the esthetic zone: a retrospective
duced size of the implant neck allowed a pros-
clinical study with 6 months to 4 years of follow-up. Clin
thetic emergence that is comparable with the To conclude, this type of implant can help to
Implant Dent Relat Res 2000;2:138-146.
natural teeth that have been replaced (Figures obtain a quick & simple functional and aesthet-
5. Achilli A, Tura F, Euwe E. Immediate/early function with
15 and 17). ic result, but it must be remembered that the tapered implants supporting maxillary and mandibular
abutment shaped in this way must respect spe- posterior fixed partial dentures: preliminary results of a
cific indications of use in the mandibular ante- prospective multicenter study. J Prosthet Dent. 2007
rior region or in the superior lateral incisors, in Jun;97(6 Suppl):S52-8. Erratum in: J Prosthet Dent
2008;99:167.
DISCUSSION order to avoid possible risks of fractures caused
6. Marchack CB. CAD/CAM-guided implant surgery and
AND CONCLUSIONS by functional overload.
fabrication of an immediately loaded prosthesis for a
partially edentulous patient. J Prosthet Dent 2007;97:389-
The decision to proceed with immediate 94.
loading was taken for the following reasons: 7. Ganeles J, Wismeijer D. Early and immediately restored
• the bone height and bone quality available al- BIBLIOGRAPHY and loaded dental implants for single-tooth and partial-
arch applications. Int J Oral Maxillofac Implants 2004;19
lowed the 13 mm implants to be positioned
1. Malo P, Friberg B, Polizzi G, Gualini F, Vighagen T, Rangert Suppl:92-102. Review.
with an insertion torque of 30-35 Ncm;
B. Immediate and early function of Brånemark System 8. Chatzistavrou M, Felton DA, Cooper LF. Immediate load-
• the patients had normal occlusion and no
implants placed in the esthetic zone: a 1-year prospec- ing of dental implants in partially edentulous patients: a
parafunctional activity, therefore the dental tive clinical multicenter study. Clin Implant Dent Relat Res clinical report. J Prosthodont 2003;12:26-9.
units at 32 and 42 received limited occlusal 2003;5 Suppl 1:37-46. 9. Ostman PO, Hellman M, Sennerby L. Immediate occlusal
loads, which were mainly vertical in direc- 2. Calvo Guirado JL, Saez Yuguero R, Ferrer Perez V, Moreno loading of implants in the partially edentate mandible: a
tion; Pelluz A. Immediate anterior implant placement and ear- prospective 1-year radiographic and 4-year clinical study.
ly loading by provisional acrylic crowns: a prospective Int J Oral Maxillofac Implants. 2008;23:315-22.
• as a result they did not have to bear the
study after a one-year follow-up period. J Ir Dent Assoc. 10. Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH.
large chewing forces which were borne by
2002;48:43-49. Considerations preliminary to the application of early
the posterior teeth. Micro-movements could
3. Glauser R, Ree A, Lundgren A, Gottlow J, Hammerle CH, and immediate loading protocols in dental implantology.
therefore be avoided, which are harmful for Scharer P. Immediate occlusal loading of Brånemark im- Clin Oral Implants Res 2000;11:12-25.
the formation and maintenance of a stable plants applied in various jawbone regions: a prospective,
bone-implant interface10. 1-year clinical study. Clin Implant Dent Relat Res 2001;