Foundation Design

200*200 column, ultimate design load=700kN


(Service load=500kN) allowable bearing
pressure=150kN/m2 fc,k=25MPa fy,k=460MPa
density of r/f concrete=25kN/m2

Divide ultimate load to obtain service load


(approximately) by 1.35 or 1.45

Multiply service load to obtain ultimate load


by 1.4 or 1.45

Expected total load=1.08*500=540kN

Footing weight=8% of service load

Required area for base = total load/soil


bearing pressure= ___m2

L= ____

Take the base thickness 0.45m

Weight of base= 25kN/m3*2*2*0.45=45kN

Actual total load=500+45=545kN(only the


service load)

Required bearing pressure=act tot load/area


. of the
base

Ans ^ < given value (check ok)

Preliminary check on effective depth

d>10(N)0.5 N= ultimate load

ultimate bending pressure=ultimate load/ .


area of footing

critical bending moment(@col face)= moment


about col face(w*l*l/2)

w= ultimate bending pressure*distance from


col face to footing edge

assume a cover (page 50) 40mm

if bar size 16mm is assumed.

Dmin = h-cover /2

Dmax = h cover /2

Davg = (Dmax + Dmin )/2

K = M/bd2fc,k

K should be less than 0.167=k/

[
Z =d 0.5+ 0.25
k
1.184 ]
Ans should be less than 0.95d

If not take Z=0.95d

M
As=
0.87 f ck Z

1.5(cx+3d)
Design strength = Table 3.5 page 38
Characteristic strength(f k ) Reinforcement covering for durability

Concrete Design
safty factor ( m ) Table 3.6 page 39

Reinforcement covering for fire resistance


For m see table 3.3 page 35
Table 3.9 page 44
Durability and fire resistance