Você está na página 1de 4

U.D.C.: 669.

14-418 June 1984

Hot-rolled narrow steel strip: EURONORM

tolerances on dimensions and shape 48-84

CONTENTS

1 SCOPE 5. TOLERANCES ON SHAPE

2 DEFINITIONS 5.1 Edge camber


3 FORM A N D CONDITION OF DELIVERY 5.2 Form of coils

3.1 Form of delivery 6 TESTING


3.2 Delivery condition
6.1 Thickness
4 TOLERANCES O N DIMENSIONS 6.2 Width
6.3 Edge camber
4.1 Thickness
4.2 Width
4.3 Length (for cut-lengths) 7 PACKING

1 SCOPE

1.1 Note:
The application of this EURONORM to other steels may be
This EURONORM applies to non-coated steel strip hot- agreed on ordering.
rolled in widths < 600 mm from:
mild unalloyed steels for cold forming (for quality require- 1.2
ments see EURONORMS 46 and 111), This EURONORM does not apply to hot-rolled wide strip
general structural steels (for quality requirements see and steel strip (< 600 mm wide), which has been produced by
EURONORM 25 and, slitting hot-rolled wide strip. (The requirements on the toler-
fine grain weldable structural steels (for quality require- ances on dimensions and shape for these products are speci-
ments see EURONORM 113). fied in EURONORMS 51 and 112.)

2 DEFINITIONS

The definitions in EURONORM 79 apply for the terms hot rolled, strip, hot-rolled wide strip and narrow steel strip.

3 FORM A N D CONDITION OF DELIVERY

3.1 Form of delivery can also be supplied mechanically or chemically descaled


(pickled), neutralized and oiled.
Hot-rolled narrow steel strip according to this EURONORM
may be supplied:
in coils, the diameter and mass of which are to be agreed at 3.2.2
the time of ordering,
The products are usually supplied with as-rolled edges. Deliv-
in cut lengths (when the coils have been unrolled and cut
ery of narrow steel strip with sheared, trimmed or bevelled
into lengths), the length and finish of which are to be agreed at
edges shall be the subject of an agreement.
the time of ordering.

3.2 Delivery condition 3.2.3


3.2.1
Hot-rolled narrow strip may be delivered with either cropped
Products according to this EURONORM are usually sup- or uncropped ends subject to agreement at the time of order-
plied in the as-rolled condition. By agreement the products ing.

Only the last edition of the EURONORMS quoted is valid

Copyright by the Standardization Offices of the European Communities' Member States


Page 2

4 TOLERANCES ON DIMENSIONS

4.1 Thickness Table 2


Permissible crown
4.1.1 (values in mm)
The tolerances on thickness (including crown as in 4.1.2) are
Nominal width of the strip Permissible crown
given in Table 1 (testing according to 6.1.1 and 6.1.2).
< 250 0 to 0.06
> 250 < 600 0 to 0.07
4.1.1.1
These values only apply for steel grades with a specified 4.1.2.2
minimum yield stress < 355 N/mm 2 . The tolerances are in-
creased by 10% for steel grades with a specified minimum The crown should be as regular as possible and symmetrical
yield stress > 355 N/mm 2 < 460 N/mm 2 and by 25% for steel to the strip axis.
grades with a specified minimum yield stress > 460 N/mm 2 .
4.1.3
The difference in the thickness within a coil shall not be
Table 1
greater than:
Tolerances on thickness
(values in mm) 0.14 mm for nominal thickness < 4 mm
0.17 mm for nominal thicknesses > 4 < 8 mm and
Tolerances 3n thickness 0.20 mm for nominal thicknesses > 8 mm
Nominal thickness for nomir al widths (testing according to 6.1.4).
> 10 < 100 > 100 < 600

> 0.80 < 1.50 0.12 0.14


4.1.4
> 1.50 < 2.0 0.14 0.16 Variations in thickness shall be gradual and not occur irregu-
> 2.0 < 4.0 0.15 0.17 larly.
> 4.0 < 5.0 0.16 0.18
> 5.0 < 6.0 0.17 0.19
> 6.0 < 10.0 0.18 0.20
4.2 Width
> 10.0 < 15.0 0.22 0.24
4.2.1
The tolerances on width are given in Table 3, for strip with as-
rolled edges, and in Table 4 for strip with sheared edges.
4.1.1.2
The tolerances on thickness as given in Table 1 and 4.1.1.1 4.2.2
only apply to deliveries of more than two coils of the same
steel grade and nominal dimensions. Tolerances for smaller These values only apply to steel grades with a minimum
deliveries are to be specially agreed at the time of ordering. specified value for the yield stress ^ 355 N/mm 2 . The toler-
ances are increased by 10% for steel grades with a minimum
specified value for a yield stress > 355 N/mm 2 < 460 N/mm 2
4.1.1.3 and by 25% for steel grades with a minimum specified yield
stress > 460 N/mm 2 .
By agreement at the time of ordering the total tolerance on
thickness may be either all plus or all minus.
Table 3
Tolerances on width for strip with as-rolled edges
(values in mm)
4.1.2
The crown measured as the increase in thickness between a Nominal width Tolerance on width*
point 20 mm from a longitudinal edge and a point in the
centre of the strip (see 6.1.3) shall not exceed the values given < 40 0/+1.6
> 40 < 80 0/+2.0
in Table 2.
> 80 < 150 0/+2.4
> 150 < 250 0/+3.0
> 250 < 400 0/+3.6
4.1.2.1 > 400 < 500 0/ + 4.2
> 500 < 600 0/+4.5
The percentage increases in tolerances given in 4.1.1.1 for
steel grades having a specified minimum yield stress of * Symmetrical plus-minus values for the tolerance on width may be
> 355 N/mm 2 also apply to the permissible crown tolerances agreed at the time of ordering (e.g. 1.8 mm instead of 0 + 3.6 mm).
The tolerance range for this shall correspond to that listed in the table.
given in Table 2.
Page 3

Table 4 4.3 Length (for cut-lengths)


Tolerances on width for strip with sheared edges 4.3.1
(values in mm)
Lengths cut from steel strip are usually supplied in fixed
Tolerances on width* lengths between 1 000 mm and 8 000 mm with tolerances on
Nominal for the nominal thicknesses length as given in Table 5. The type of tolerance required shall
width
<3.0 >3.0<5.0 >5.0<7.0 >7.0<10.0 >10.0 be stated on the order.

< 80 0/+0.5 0/+0.7 0/+0.8 0/+1.0 Table 5


y
> 80 < 250 0/+0.5 0/+0.7 0/+0.8 0/+1.2
agree Tolerances on length
> 250 < 400 0/+0.6 0/+0.8 0/+1.0 0/+1.2 "
ment (values in mm)
> 400 < 600 0/+0.6 0/+0.8 0/+1.0 0/+1.4
Type of tolerance Tolerance on length
* Symmetrical plus-minus values for the tolerance on width may be
agreed at the time of ordering (e.g. + 0.4 mm instead of 0/+ 0.8 mm).
The tolerance range for this shall correspond to that listed in the table. Normal tolerance 0/+100
Reduced tolerance 0/+ 50
Fine tolerance 0/+(0.005-L+15)*
4.2.3 with a maximum of 50

Variations in width shall be gradual and not occur irregularly. * L = ordered length.

4.3.2
The tolerances for cut lengths having ordered lengths differing
from those in 4.3.1 shall be agreed at the time of ordering.

5 TOLERANCES ON SHAPE

5.1 Edge camber 5.1.2

5.1.1 The permissible edge camber for cut lengths of less than
2 500 mm shall be agreed at the time of ordering.
The permissible edge camber related to a measured length of
2 500 mm, shall be: 5.2 Form of coils
20 mm for products ^ 40 mm wide The coils should be tightly wound, as round as possible and
10 mm for products > 40 mm < 600 mm wide. straight edged. Gradually stepped displacement of the edge of
(Testing as in 6.3). the strip to one side should not exceed 35 mm.

6 TESTING

6.1 Thickness 6.1.4

6.1.1 The variation in thickness over a coil (see 4.1.3) shall be


measured on a line running parallel to and at least 20 mm
The thickness may be measured at any point on the centre line from the longitudinal edge of the strip.
for products up to 40 mm wide, and at any point at least 20 mm
from the longitudinal edge for products over 40 mm wide.

6.1.2 6.2 Width


The minimum distance of the points of measurement from the The width shall be measured perpendicular to the longitudinal
beginning or end of the strip shall be 3 000 mm for coils with axis outside the area of any uncropped end.
uncropped ends and 2 000 mm for coils with cropped ends.
These minimum distances may be reduced by agreement at
the time of ordering. 6.3 Edge camber
The maximum distance between one longitudinal edge and a
6.1.3
straight line which connects either end of the measured length
The measuring points when measuring the crown (see 4.1.2) (2 500 mm) is considered to be the edge camber (see 5.1), and
shall lie on a line running perpendicular to the longitudinal this is measured on the concave side of the product outside
axis of the product. the area of any uncropped ends of coils.
Page 4

7 PACKING

The coils shall be secured in such a w ay that they are not damaged nor unw ind in the course of normal careful loading,
transportation and storage.

Price (excluding VAT) in Luxembourg


ECU 3.96 BFR 180 DKR 32 300 IRL 2.90 UKL 2.30 USD 3.50

* OFFICE FOR OFFICIAL P UBLICATIONS Catalogue number: CB-38-83-726-EN-C


M OF THE EUROPEAN COMMUNITIES

L - 2 9 8 5 Luxembourg

EURONORMS are on sale at:


United Kingdom: British Standards Institution, 2 P ark Street, London W1A 2BS
Ireland: Institute for Industrial Research and Standards, Ballymun Road, Dublin 9
Denmark: Dansk Standardiseringsrad, Aurehjvej 12, Postboks 77, DK-2900 Hellerup
Greece: ELOT Hellenic Organization for Standardization, Didotou 15, Athens 144