Você está na página 1de 8

PC13-03-07_2

VECTOR MULTI-METER
(Color LCD)
MODELCDM-330C
Drastic improvement of original Vector Multimeter(Model: CDM-330)is realized
with high speed measuring very bright color display.
Whole of existing options are available with model:CDM-330C

Versatile measuring functions can meet various needs.


AC voltage, current, phase, frequency, active power, reactive power, power factor
and DC voltage, As a standard.
3-phase current, DC current, time, phase between each voltage and data printing with Options.

Simultaneous display of measured values and required data can be seen at the same time.
Voltage, current, phase, and frequency, or active power, apparent power, reactive power and
ower factor.

Measured value and waveform displays as well as measured value and vector displays available.
Waveform display indicates peak value also, so very much useful for data check.

Available to analyze harmonics.


Analysing harmonics of Voltage and Current and display both by numerical and graph.

Various options available to expand application.

1
VECTOR MULTI-METER Color Model CDM-330C PERFORMS
Color display with a clear indication even in dark environment.

High speed updating time of measurement.

BAT. 10 DEC. 2012 00:00:00


Approximately 6 and half hours of battery life with continuous use.
110.0
5.000 Function of date format installed additionally.
30
50.0
HOLD
AVERAGE
ON OFF
ON OFF
Whole of OPTIONS for former model (CDM-330)available to apply.
V-RANGE 1.5V 15V 150V 300V AT
I-RANGE 10mA 100mA 1A 5A 20A AT

Measuring current by clamp CT realizes and safety measurement
without disconnecting the current circuit.

Enough functions and capability by its own, however, together with


Options much more functional capability is increased as follows:

Measurement of 3-phase AC current and its phase angles(CT-03BU


Measurement of DC current by the DC clamp CTDCT-23
Time measurementMCS-330
Measurement of phase between voltage and voltageCAD-230 or CAD-240
Data print-outPR-332

Specifications
Power Supply LR6 alkaline type dry battery 8 pcs. Battery life 6 hours approx.(continuous)
Dielectric Strength For 1 min. between the case and input terminal at 2000VAC, 50/60Hz
Operating temperature range 040
Operating humidity range 2095%Without condensation
Bit format 320240 dots Display area 5268mm
Display details
Standard Measured-value display (voltage, current, phase angle, and frequency)
Measured value + input waveform displays
Measured value + input vector diagram displays
Display Unit(LCD)
Active power, apparent power, reactive power and power factor displays
With Option Single-phase voltage, 3-phase current and phase angle displays
Single-phase voltage, 3-phase current and phase-angle vector displays
Display of phase angle between each voltage
Time measured-value + Timing chart
No. of input channels: 2 channels (basic)
Input With the option (CT-03BU) 4channels
Input impedance Voltage 1M Current Zero burden type
Resolution 14bitsHigh-speed successive comparison type
A/D Converter
Sampling method Simultaneous REFINPUTsampling
Display Updating Time DC measurement approx 0.1sec, AC measurement approx 0.3sec
Clock Year, month, day, hour, min. and sec. With backup batterydesigned life 10 years approx.
Main body W=100 H=225 D=70 mm 750g(with batteries 8)
DimensionsWeight
With soft case W=180 H=235 D=75 mm 1250g

Clamp CT Specifications
Rated Primary Current 20A Window diameter 25mm
Rated Secondary Current: 10mA Dimensions 64(W)165(H)mm

2
AC Voltage AC Current AC Power DC Voltage DC Current Note2 DC Power Note2
Digital processing
Measuring Method
(i2) (i2) (ViAi) Vi Ai (ViAi)

0.01W10kW 10W100kW
Range 1.5/15/150/300 0.01/0.1/1/5/20 1.5/15/150/300 20/200
( voltage ( voltage
(AutoManual) (V) (A) (V) (A)
/current range) /current range)
Frequency Range 4565Hz
15/150/300(V)
0.1/1/5/20(A) 0.1/1/5/20(A)
0.5% of rang
1.0% of range 1.5% of range
0.5 of range 1.5V range 3.0% of range 4.0% of range
10mA range 10mA range
Accuracy Note1 (10 to 120% of 0.5% of range (10 to 120% of (10 to 120% of
2.0% of range 2.5% of range
range) 5 digit range) range)
(10 to 120% of (10 to 120% of
(10 to 120% of
range) range)
range)
Power Factor 2.5% of range

Influence at COS0.5

Phase Angle Frequency


Measuring Method Digital processing
1.5/15/150/300(V) 0.01/0.1/1/5/20(A)
Range 0359.9Display of INPUT Lag angle against REF
(AutoManual)
Current
0.1/1/5/20(A)Range 20%120% 3
Less than 20% 10% 4
10mA Range100% 120% 5
Adding 1every 1mA decrease
Minimum phase angle measuring input current 2mA
Voltage 1.5/15/150/300(V)
Accuracy 30%120% Within these scopes, accuracy of phase angle 0.1% of rdg (at 100% of range)
against the current in each range is assured.
(When using within these scope of % no
consideration for voltage character is
required)
10%30%under Adding 1on measuring accuracy (When
using less than 30% of input voltage value
per each range against the current
Note1 By all of sine wave inputs with using AVG key.
Note2 When DC clamp CT(DCT-23) of option is used.

Apparent Power Reactive Power Power Factor

Computing
VrmsArms 22 WVrmsArms
Equation

Computing
1digit of displayed value
Accuracy
Accuracy Depending on measuring function

Harmonic Analysis
Display method Analyze harmonics of voltage and current, displayed by numerical value and graphic.
Harmonic analysing order 2nd15th
Measuring range 0.15360V1mA24A(AUTO range)
Analysing time 0.5 second approx.
Resolution 0.1%
Less than -2digits at 10.0% from 2nd to 5th harmonics.
Measuring accuracy of distortion factor
From 6th to 15th harmonics, -3digits are added per one harmonic is increased.
per each harmonic
For example 5th 9.8%9.9% 10th 9.2%9.7% 15th 7.5%7.8%)

3
Display Examples
Basic Display 1-Phase Vector Display 3-phase Vector Display(with option)
BAT. 10 DEC. 2012 00:00:00 BAT. 10 DEC. 2012 00:00:00 BAT. 10 DEC. 2012 00:00:00
V
V 110.1V V
V I1
110.0 1.228V I1
5.003A
5.000
178.5
30
I2 I3
30 I
5.003A
150
7.67mA
50.0 I
I3
5.006A
I2
270
HOLD ON OFF HOLD ON OFF HOLD ON OFF
AVERAGE ON OFF AVERAGE ON OFF AVERAGE ON OFF
V-RANGE 1.5V 15V 150V 300V AT V-RANGE 1.5V 15V 150V 300V AT V-RANGE 1.5V 15V 150V 300V AT
I-RANGE 10mA 100mA 1A 5A 20A AT I-RANGE 10mA 100mA 1A 5A 20A AT I-RANGE 10mA 100mA 1A 5A 20A AT

Waveform Display Harmonic analysisvoltage Harmonic analysisCurrent


BAT. 10 DEC. 2012 00:00:00 BAT. 10 DEC. 2012 00:00:00 BAT. 10 DEC. 2012 00:00:00
V Harmonic I Harmonic
V Distortion Factor 13.3% Distortion Factor 13.2%
100.1 f % f % f % f %
1 100.0 9 0.3 1 100.0 9 0.3
2 0.2 10 0.1 2 0.1 10 0.1
359 3 11.4 11 0.0 3 11.4 11 0.2
4 0.2 12 0.1 4 0.1 12 0.2
I 5 6.2 13 0.1 5 5.8 13 0.1
5.2mA 6 0.0 14 0.1 6 0.2 14 0.1
7 3.2 15 0.1 7 3.3 15 0.2
8 0.1 8 0.2
0 10 (mS) 20 30
HOLD ON OFF HOLD ON OFF HOLD ON OFF
X-AXIS 30mS 300mS 3S AVERAGE ON OFF AVERAGE ON OFF
V-RANGE 1.5V 15V 150V 300V AT V-RANGE 1.5V 15V 150V 300V AT V-RANGE 1.5V 15V 150V 300V AT
I-RANGE 10mA 100mA 1A 5A 20A AT I-RANGE 10mA 100mA 1A 5A 20A AT I-RANGE 10mA 100mA 1A 5A 20A AT
SAMPLE=100uS

Time Measurement with the time Harmonic analysisVoltageGraphic Harmonic analysisCurrentGraphic


counter module of option
BAT. 10 DEC. 2012 00:00:00 BAT. 10 DEC. 2012 00:00:00 BAT. 10 DEC. 2012 00:00:00
V Harmonic I Harmonic
START % Distortion Factor 13.3% % Distortion Factor 13.2%
100 100

STOP 10 10

1 1
0 (mS) 100

0.1 0.1 1
1 3 5 7 9 11 13 15f 3 5 7 9 11 13 15f

HOLD ON OFF HOLD ON OFF


X-AXIS 10mS 100mS 1S 10S 100S AVERAGE ON OFF AVERAGE ON OFF
STATUS STAND-BY BUSY END AT V-RANGE 1.5V 15V 150V 300V AT V-RANGE 1.5V 15V 150V 300V AT
MODE INTERVAL ONE-SHOT TRAIN AT I-RANGE 10mA 100mA 1A 5A 20A AT I-RANGE 10mA 100mA 1A 5A 20A AT

4
Option
DC Clamp CT, Model DCT-23
Clamp CT to measure DC current.
Position Connected to CDM-330C

Measuring Range 2 to 200A 20A200A Range

Measuring Accuracy 3% of rangeApplicable 10 to 100% of range

Button shaped battery (Type:LR44) pcs


Built-in Cell
Life approx 30hours

Voltage-Phase Module, Model CAD-230CAD-240


Module to measure phase angle between voltage and voltage, also voltage value at REF side.
Position CDM-330C soft case TU-330 or TU-331B

Measuring Range CAD-230 AC60 to 120V CAD-240 AC50 to 450V

Measuring Accuracy CAD-230 3(For sine wave) CAD-240 5(For sine wave)

In accordance with the range of CDM-330C, voltage up to 360V available to measure, though voltage input to
CAD-240 available up to 450V.

AC Clamp CT, Model CT-25C and CT-23B


Model - -

1 pc of CT-25C is included in CDM-330C, as


a standard accessory. Durable type
Function As a spare application. Compatible with
Impossible to bend the neck
CT-25B(For CDM-230B).
Neck is bended to 90

5
AC Adaptor, Model ACA-332
For AC power operation of CDM-330C.

Voltage 90264V AC power supply

Discontinued AC Adaptor model ACA-330 and/or 331 are available for CDM-330C.

selector Module, Model CT-03BU


For displaying 4-element numeric values of 3-phase current and reference input and a vector diagram by
Using 3 clamp CT(CT-25C)
Mother UnitTU-330,TU-331B
Position
Built into mother unit TU-331B already
3-phase Current
CT input is selected by analog switch automatically
Measuring method
Current Range Same as current measuring input of CDM-330C.
Current 20A to 0.1A range: 1.0% of range
10mA range: 10 digit (REAL)
Measuring Accuracy (Applicable 10 to 120% of range)

Phase 50.1 to 20A range, 20 to 120%, 0.120A


610mArange, 100 to 120%
Input Burden Zero burden typeWith built-in error compensation circuit
Frequency Range 45 to 65Hz
Connection with
Connected via connectorsTU-330
vector multimeter
Accessory Clamp CT CT-25C 2pcs

Printer Module, Model PR-332 (For TU-330)


High-speed monochrome printer used to print displays on the screen of the CDM.
Position Mother UnitTU-330

Printing Method Thermosensible line head type


Printing time of
Displays on one Approx. 10sec.
screen
Printing Paper Size Paper width: 58mm Outside dimension: 30mm Roll length:9m

Full - S CAL E SI ZE

10 DEC. 2012 00:00:00


V
V
1.228V

31. 5 m m

178.5
I
7.67mA
I

HOLD ON OFF
AVERAGE ON OFF
V-RANGE 1.5V 15V 150V 300V AT
I-RANGE 10mA 100mA 1A 5A 20A AT

40mm

6
Time Counter Module, Model MCS-330 (For TU-330)

Module for measuring time. Both START and STOP are corresponding to CONTACT / DC / AC
Position Mother UnitTU-330

Measuring range 0.0ms to 999.9s 4digits, automatic carry

Input Terminal For both START and STOP 1 setCONTACT/DC/AC)

No-voltage contact MAKE/BREAK available for both


Input Signal DC voltage 5250V IMPRESS/ELIMINATE available for both
AC voltage 20250V IMPRESS/ELIMINATE available for both
No-voltage contact Approx 1k+12V pull up
Input Impedance DC voltage Approx 100k
AC voltage Approx 100k

Measuring Accuracy CONTACT/DC 1digit200s AC 1digit5ms

Mother Unit, Model TU-331B


CT selector module CT-03BU for measuring 3-phase current and
phase angle is built-in.
Small mother unit is possible to contain not only CDM-330C but also
voltage-phase module model CAD-230 or CAD-240.
2 pcs of Clamp CT model CT-25C is included as a standard accessory.
Please refer How to place an order on the last page of this
catalog.
Dimension: 245W90H250Dmm

Mother Unit, Model TU-330


Large mother unit is possible to contain CDM-330C and many of
options.
Printer module(PR-332) and time counter module (MCS-330) are
designed to apply solely in this large mother unit of TU-330.
Please refer How to place an order on the last page of this
catalog.

Dimension: 400W170H300Dmm

Optional Storage Case TU-333


Extra space for working tools, instruction manual are secured in
addition to the space for CDM-330C, CAD-230, CAD-240, ACA-332
and etc.
Soft carrying case is provided to CDM-330C as a standard
accessory.

Inside Dimension: 295W234H95Dmm

7
Basic Set and How to place an order
1. Basic set of CDM-330C
Consisting of:
Main body 1 pc
Soft carrying case 1 pc
AC clamp CT(CT-25C) 1 pc
Voltage lead wire(red & black)@1m(L)1 set
LR6 Alkaline dry battery 8 pcs

Size of soft carrying case is designed larger than original


(for CDM-330)type.
So possible to contain CAD-230(or CAD-240), ACA-332 and

2. Small mother unit TU-33B for 3-phase current and phase angle measurement.

Consisting of:
Main body 1 pc
(CT selector module CT-03BU is built-in)
AC clamp CT(CT-25C) 2 pcs

Required model to purchase additionally:


Vector Multi-meter(CDM-330C) 1 pc
Voltage-phase module(CAD-230 or CAD-240) 1 pc

2 pcs of clamp being included in TU-331B and 1 pc of


clamp included in CDM-330C can realize measuring
3-phase AC with total 3 pcs of clamp CT(CT-25C)

3. Large mother unit TU-330 can contain whole of OPTIONS.


Consisting of:
Main body 1pc

Required model to purchase additionally:


Vector Multi-meter(CDM-330C) 1 set
CT Selector Module(CT-03BU) 1 set
Voltage-phase module(CAD-230 or CAD-240) 1 pc
DC clamp CT(DCT-23) 1 pc
AC Adaptor(ACA-332) 1 pc
Printer module(PR-332) 1 pc
Time counter module(MCS-330) 1 pc

pcs of clamp CT(CT-25C)is included as a


standard accessory, and this module is designed
solely for TU-330.
This module is designe solely for TU-330

OTA Techno CORE No.301 distributor


6-4-17, Higashikoujiya, Ota-ku, Tokyo-to,
144-0033 Japan
TEL +81-3-6423-8122 FAX +81-3-6423-8123
E-mail:dtec@densokutechno.co.jp
URL http://www.densokutechno.co.jp/ 8

Você também pode gostar