Você está na página 1de 43

PRODUCT CATALOG

4
www.yssignal.com
Every year, many accidents occur all over the world because of safety troubles.
Injury and wrongful death expectancy in industry working environment is far high than
after-working environment. Since 1990, we kept focusing on people working under hazardous
environ- ments, from harbor to mining field, metallurgy plant, tall building, high-way, and
off-shore site, etc. Our engineers go to all of above work sites to develop more reliable
industry warning & communication products.

About us
Hunan YuanSheng in Hunan Province, Changsha City.The company was started in 2014 by a group of young people
concentrate on signal lighting designing and manufacturing.We kept focusing products research hope to design more
state-of-the-art products to meet needs of the market.we offers single obstruction light,double obstruction light ,
intensity obstruction light,obstruction control box and solar obstruction light. hope our products add luster to the
high altitude, provide better security for the safety of everyone.

Our advantage

Deep understanding on technologies that our product require Absolutely


following rules & regulations in the industry we are serving

Our values
Dedication
Candor
Eager for action
Continuous change
Contents

Low Intensity
...........................................................01

YOL10 LED Based Low Intensity Obstruction Light ...........................................................01


...........................................................01
YOL32 LED Based Low Intensity Obstruction Light ...........................................................03
...........................................................01
...........................................................05
YOL-E27 LED lamp for low intensity Obstruction light
...........................................................07
YOL100 LED Based Low Intensity Obstruction Light
YOL200 LED Based Low Intensity Obstruction Light ...........................................................09

Medium Intensity

YML2000B LED Based Medium Intensity Aviation Obstruction Light ...........................................................11


YML2000C LED Based Medium Intensity Obstruction Light ...........................................................13

Solar Light
YSL10 Solar Powered Obstruction Light ...........................................................15
YSL10 Solar Powered Obstruction Light
YSL10 Solar
YSL10D Powered
Solar Obstruction
Powered Light
Obstruction Light ...........................................................17

YSL50 Solar Powered Obstruction Light ...........................................................18

YSL50 Solar Powered Obstruction Light ...........................................................20


YSL2000 Solar Powered Obstruction Light ...........................................................22

Control Box
...........................................................24
CB04I Control Panel Indoor Type
...........................................................25
CB02 Obstruction Light Control Box
CB04O Obstruction Light Control Box ...........................................................26

CB20 Obstruction Light Control Box ...........................................................28

Others ...........................................................29
Obstruction Marking Sphere ...........................................................30
Installation Accessories ...........................................................32
Warranty Policy ...........................................................34
ICAO Recommendation And Practice Over Various Applications ...........................................................36
YOL10 LED Based Low
Intensity Obstruction Light
APPLICATIONS
Yuan sheng YOL10 series is typically a standard LED Obstruc- tion light
c o
designed for airway fixed obstacle marking application. p
It comply with ICAO regulation, low intensity, type A. Working mode is l a mtlc towers power lines
steady burning. C
buildings

YOL10 series double light


YOL32 wind turbines flare stacks
chimneys
Double light is integrated by 2 single lights. For making sure there is always a light working atop of the
tower. Two optional working patterns can meet different areas customers.
Service+Standby: Only service light is working normally. It will auto-transfer to standby light in
case of service light failure
Service+Service: Two single lights work simultaneously. Either failure will not affect the other normal
working.
Features Standard

LED light source esures long lifetime, maintenance free ICAO Annex 14, 4th Edition, July 2004
Low power consumption ICAO low intensity, tpye B
Shock and vibration resistant FAA AC No. 150/5345-43F, 2006
Corrosion resistant and UV stable polycarbonate FAA type L810
housing DGAC Mexico
Ease of mount, mount accessories available
Available both in single and double type
5 years warranty
Special optical design the distribution of light 360 degrees more uniform

01 www.yssignal.com
Specifications
LIGHT OUTPUT YOL10S(Single) (Double)
YOL10DST YOL10DSS (Double)
Effective Intensity 10 Candela 110Candela 10Candela
Vertical Divergence 10 Degree
Horizontal 360 Degree
LED color Red
LED lifespan 100,000 Hours
OPERATION
Flash Pattern Steady burning(default)
POWER SUPPLY
Input voltage 110-220VAC, 50/60 Hz;12VDC;24VDC;48VDC
Power Consumption 4W 4W 8W
MACHANICAL STRUCTURE
Lens Polycarbonate,UV Stabilized
Body Die-casting Aluminum
Water-proof IP65
Weight 0.9KG 3.5KG 3.5KG
Dimension 159mmx245mm 340mmx413mmx140mm 340mmx413mmx140mm

Mounting Size Threaded 3/4 bottom hub


Temperature Range -40C ~ +55C
Relative Humidity 100% with condensation
Wind speed Up to 150mph(240kph)
Warranty 5 years
Optional Available in flashing pattern(40FPM)
Available with built-in photosensor
Available with built-in alarm relay contacts

ST: Service+Standby SS:Service+Service

Order codes
Single/ Alarm Pattern(For
Series Voltage Flashing Photosensor
Double Flashing/steady Photosensor relay double light only)
YOL10 S F P R ST
D s SS

Pipe diameter range 30-80 mm

Ordering Code: AMU80


For example YOL10SSPR means YOL10 single light red steady burning
with alarm relay contacts. We YOL10 series product 24Vdc 48Vdc 110vac 220vac is the same . Mounting kit for 30-80mm vertical
but if you need double light or other voltage need to explain(12VDC,24VDC,48VDC, 220VAC) or horizonal pipe

Photometric Performance
Light Effective Intensity (candela)

YOL10 Data

Pipe diameter range 60-100 mm

-5
Ordering Code: AMU100
Vertical Divergence (degrees) Mounting kit for 60-100mm vertical l pipe

www.yssignal.com 02
YOL-E27 LED lamp for low intensity
aviation obstruction light
YOL- E27 LED lamp is specially designed for low intensity obstruction light. With Fresnel optic lens, in
compliance with ICAO and FAA standard.

Features
Electronic characters:
Self-contained electronic control design
Based on LED technology, long lifetime, low maintenance
cost
Extremely low power consumption,
Top mounted LED indicator for power supply and operation
status
Over voltage protection
Reverse polarity protection Y
Available in DC12/24/48V and AC110/220V
Mechanical characters:
Universal E27 lamp holder, easy replacement
Robust aluminum lamp body, providing better heat
dissipation
Good anti-vibration
520.5
128+50

E27
03 www.yssignal.com
Specifications E27100
YOL -E2710 YOL -E2732
LIGHT OUT-PUT
Effective Intensity (Work in light) >10cd >32.5cd >100cd
Standard >ICAO type B
ICAO type A ICAO type B >FAA L810
FAA L810 CASA
LED Nos 16 16(High-Flux)
8
Vertical Divergence 120 degree
Horizontal Output 360 degree
LED color Aviation Red, Other colors are available upon request
LED lifespan 100,000 hours
Operation pattern Steady-burning or flashing
Power Supply
Nominal Voltage 12VDC,24VDC,48VDC
110VAC, 220VAC 50/60HZ
Power Consumption 4W 6W 8W
Mechanical Structure
Body Aluminum
Base E27
Weight 0.15KG
Temperature Range -40C- +55C
Dimension 128mm*52mm(HxDia.)
Warranty 5 year
Optional Available with built-in photosensor

Type Series AC/DC Flashing/Steady Voltage


YOL-E27 10 A F 12
32 D S 24
48
110
220

For example, YOL -E2732DS48 means, E27 LED lamp, effective intensity>32.5cd tted in Fresnel
lens, DC48V power supply , steady-burning.

Photometric Performance (Work in light)


120
115 YOL -E2710 Data
110
105 YOL -E2732 Data
100
95
90
85 FAA L810 minimum requirement
80
75
ICAO 32.5cd minimum requirement
70
65
ICAO 10cd minimum requirement
60
55
50 Recommendation :
45
40 For buyers who have installed other
35
30
brand-name obstruction light that with
25
20
Fresnel Lens, YOL -E27 lamp can built
15 into most of them after minor LED position
10
5
change vertically.
0

-20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20


Please consult our sales for further
assistance.

www.yssignal.com 04
YOL32 LED Based Low
Intensity Obstruction Light
APPLICATIONS
Yuan sheng YOL32 LED Low Intensity Obstruction Light series
o
pc
is a 32.5cd (candela) LED light designed for airway fixed
obstacle marking application. It comply with ICAO & FAA
regulation. It shares the same mechanical design with l a mtlc towers power lines
YOL10, but comes with more LED. C
buildings

wind turbines chimneys flare stacks


YOL32 series double light
Double light is integrated by 2 single lights. For making sure there is always a light working atop of the
tower. Two optional working patterns can meet different areas customers.
Service+Standby: Only service light is working normally. It will auto-transfer to standby light in
case of service light failure
Service+Service: Two single lights work simultaneously. Either failure will not affect the other normal
working.

Features Standard
Special optical design provides better light distribution ICAO Annex 14, 4th Edition, July 2004
LED light source esures long lifetime, maintenance free ICAO low intensity, tpye B
Low power consumption FAA AC No. 150/5345-43F, 2006
Shock and vibration resistant FAA type L810
Corrosion resistant and UV stable polycarbonate DGAC Mexico
housing
Ease of mount, mount accessories available
Available both in single and double type
5 years warranty

05 www.yssignal.com
Specifications
LIGHT OUTPUT YOL32S(Single) (Double)
YOL32DST YOL32DSS (Double)
Effective Intensity 32.5 Candela 32.5 Candela 32.5 Candela
Vertical Divergence 10 Degree
Horizontal 360 Degree
LED color Red
LED lifespan 100,000 Hours
OPERATION
Flash Pattern Steady burning(default)
POWER SUPPLY
Input voltage 110-220VAC, 50/60 Hz;12VDC;24VDC;48VDC
Power Consumption 6W 6W 12W
MACHANICAL STRUCTURE
Lens Polycarbonate,UV Stabilized
Body Die-casting Aluminum
Water-proof IP65
Weight 0.9KG 3.5KG 3.5KG
Dimension 159mmx245mm 340mmx413mmx140mm 340mmx413mmx140mm

Mounting Size Threaded 3/4 bottom hub


Temperature Range -40C ~ +55C
Relative Humidity 100% with condensation
Wind speed Up to 150mph(240kph)
Warranty 5 years
Optional Available in flashing pattern(40FPM)
Available with built-in photosensor
Available with built-in alarm relay contacts

ST: Service+Standby SS:Service+Service

Order codes
Single/ Alarm Pattern(For
Series Voltage Flashing Photosensor
Double Flashing/steady Photosensor relay double light only)
YOL32 S F P R ST
D s SS

Pipe diameter range 30-80 mm

Ordering Code: AMU80


For example YOL32SSPR means YOL32 single light red steady burning
with alarm relay contacts. We YOL32 series product 24Vdc 48Vdc 110vac 220vac is the same . Mounting kit for 30-80mm vertical
but if you need double light or other voltage need to explain(12VDC,24VDC,48VDC, 220VAC) or horizonal pipe

Photometric Performance
Light Effective Intensity (candela)

65
YOL32 Data
55 FAA L810
minimum requirement
45
ICAO 32.5cd
minimum requirement
30
ICAO 10cd
15 minimum requirement
Pipe diameter range 60-100 mm
0
-5 0 5 10 15 20 25
Ordering Code: AMU100
Vertical Divergence (degrees) Mounting kit for 60-100mm vertical l pipe

www.yssignal.com 06
YOL100 LEDBased
YOL32 LED Based Low
Low
Intensity Obstruction Light
Yuan sheng YOL100 LED Low Intensity Obstruction Light series
APPLICATIONS
is a 100cd (candela) LED light designed for airway fixed
c o
obstacle marking application. It comply with ICAO & FAA p
regulation. It shares the same mechanical design with
YOL10, but comes with high power LED. Control flashing by
l a mtlc towers power lines
driver IC ADJ ,Compared with similar products, constant Cbuildings

flow effect is good and the service life is longer.

YOL100series
YOL32 seriesdouble
doublelight
light wind turbines chimneys flare stacks

Double light is integrated by 2 single lights. For making sure there is always a light working atop of the
tower. Two optional working patterns can meet different areas customers.
Service+Standby: Only service light is working normally. It will auto-transfer to standby light in
case of service light failure
Service+Service: Two single lights work simultaneously. Either failure will not affect the other normal
working.

Features Standard
LED light source esures long lifetime, maintenance free ICAO Annex 14, 4th Edition, July 2004
Low power consumption ICAO low intensity, tpye B
Shock and vibration resistant FAA AC No. 150/5345-43F, 2006
Corrosion resistant and UV stable polycarbonate FAA type L810
housing DGAC Mexico
Ease of mount, mount accessories available
Available both in single and double type
5 years warranty
Special optical design the distribution of light 360 degrees more uniform

07 www.yssignal.com
Specifications
LIGHT OUTPUT YOL100S(Single) (Double) YOL100DSS(Double)
YOL100DST
Effective Intensity 32.5Candela
100 Candela 32.5Candela
100 Candela 32.5
100 Candela
Candela
Vertical Divergence 10 Degree
Horizontal 360 Degree
LED color Red
LED lifespan 100,000 Hours
OPERATION
Flash Pattern Steady burning(default)
POWER SUPPLY
Input voltage 110-220VAC, 50/60 Hz;12VDC;24VDC;48VDC
Power Consumption 6W 6W 12W
MACHANICAL STRUCTURE
Lens Polycarbonate,UV Stabilized
Body Die-casting Aluminum
Water-proof IP65
Weight 0.9KG 3.5KG 3.5KG
Dimension 159mmx245mm 340mmx413mmx140mm 340mmx413mmx140mm

Mounting Size Threaded 3/4 bottom hub


Temperature Range -40C ~ +55C
Relative Humidity 100% with condensation
Wind speed Up to 150mph(240kph)
Warranty 5 years
Optional Available in flashing pattern(40FPM)
Available with built-in photosensor
Available with built-in alarm relay contacts

ST: Service+Standby SS:Service+Service

Order codes
Single/ Alarm Pattern(For
Series Voltage Flashing Photosensor
Double Flashing/steady Photosensor relay double light only)
YOL100 S F P R ST
D s SS

Pipe diameter range 30-80 mm

For example YOL100SSPR means YOL100 single light red steady burning Ordering Code: AMU80
with alarm relay contacts. We YOL100 series product 24Vdc 48Vdc 110vac 220vac is the same . Mounting kit for 30-80mm vertical
but if you need double light or other voltage need to explain(12VDC,24VDC,48VDC, 220VAC) or horizonal pipe

Photometric Performance
Light Effective Intensity (candela)

Pipe diameter range 60-100 mm

-5
Ordering Code: AMU100
Vertical Divergence (degrees) Mounting kit for 60-100mm vertical l pipe

www.yssignal.com 08
YOL200 LED Based Low intensity
Aviation Obstruction Light
Yuansheng YOL200 is a type of low intensity aviation obstruction APPLICATIONS
light, peak intensity can be up to 200 Candelas, by far exceed
o
International standard ICAO type B(32.5Candelas)
pc
l a mtlc towers power lines
C
buildings

Features
Osram High efficiency LE D
Low power consumption wind turbines chimneys flare stacks
Special lens design enhance LED efficient and distributes 360 degree visibility
Robust aluminum base with electrostatic powder painting, better corrosion-resistance
Input votage from 24-60VDC or 110VAC-260VAC
Stainless steel Cable gland for easy cable entry and wring
Optional built-in photosensor, which can work independently, turn on/off automatically from dusk to
dawn
Optional dry contact alarm relay, 3-pin side-entry screw terminal block NO-COM-NC
Available steady-burning or flashing type
Light-weight and easy installation
combined with Yuan sheng mounting kits

09 www.yssignal.com
23.2
Specifications
Light out-put
Peak Intensity 200 cd
10.0
Vertical Divergence +5 to +8 degree 200cd
0 to +15 degree 50cd

Horizontal out-put 360 degree


LED color Red(white, yellow, green, blue availabe)
204.5
LED lifespan 10,000 hours
Power supply
Operation voltage 12VDC, 24VDC-60VDC, 110VAC -220VAC(50-60HZ)

Flash Pattern Steady-Burning or Flashing(40FPM as defunit)

Power consumption 15W


215.5
Mechanical structure
Lens Polycarbonate, UV Stablized
89 95.0
Body Aluminum die-casting
Waterproof IP67
177.0
Weight 3.5KG
226.0
Temperature range -40C-+50C
Relative Humidity 100% with condensation Installation
Dimensions 215.5mm Height, 226mm Diameter
Optional Available with built-in photo sensor
Available with built-in alarm relay
AMS3080
Ordering Code
Series Single/Double AC/DC Voltage Flashing Photo sensor Alarm Relay

OL200
YOL200 S S AA 1212 FF PP RR
D D 24
48
110
220 AMS30150

YUAMS mounting kit : Ordering Code


Vertical tower leg Horizontal tower leg
Series diameter range diameter range

AMS3080 30-80mm 30-80mm

AMS30150 30-150mm 30-80mm

250
Light Effective Intensity (candela)

Photometric Performance
200
YOL200 Data
150 FAA L810 minimum requirement
ICAO 32.5cd minimum requirement
100 ICAO 10cd minimum requirement

50

0
-5 0 5 10 15 20 25
Vertical Divergence (degrees)

www.yssignal.com 10
YML2000B
OM2K LED Based
LED Based
MediumMedium
Intensity Obstruction Light
YML2000B is a new generation high efficiency medium intensity OB light. It APPLICATIONS
comes with compact-size and light-weight, which makes
installation job nice & easy. c o
p
l a mtlc towers
power lines
The optical part is based on Fresnel lens, a transformed
convex lens which can concentrate light to a small specific
C
buildings

angel to meet with ICAO requirements. Fresnel lens is


often used to design obstruction light.
The light's ingress protection level is IP67, assures wind turbines chimneys flare stacks
the light is well sealed to stand harsh environment
include the ocean. If work with control box, more functions like synchronization could be realized. GPS
or GPRS functions also available if needed.
Medium intensity light YML2000B is for tower taller than 45m. It should be used either alone, or in combina-
tion with low-intensity light type B (our YOL32 series).
tion with low-intensity light type B (our OL32 series).

Features
Standard
Unique optical design complies with ICAO
regulation ICAO Annex 14, 4th Edition, July 2004
Aluminum head provides good thermal ICAO medium intensity type B & type C
performance FAA type L864
Better shock-resistant perform than Xenon
Longer lifetime expectancy
Almost maintenance free
Lower voltage (than xenon) makes it safer
for installer
Cost effective in long run
5 years warranty

11 www.yssignal.com
Specifications
160
LIGHT OUT-PUT
Peak Intensity 2000 Candela
Vertical Divergence -1 950cd, Centering at 0.5
Horizontal out-put 360 Degree
LED Color Red
LED Lifespan 100,000 Hours

210
OPERATION
Flash Pattern Steady-burning or flashing
POWER SUPPLY
Input voltage 110VAC ~ 220VAC, 24VDC-60VDC
Frequency 50Hz ~ 60Hz
Rated consumption 40W with
35W with steady
steady mode
mode
MECHANICAL STRUCTURE
Lens Polycarbonate, UV Stabilize
Body Die-casting Aluminum
Water-proof IP67
Weight 5 KG
Temperature Range -40 ~ +55
Relative humidity 100% with condensation 226
Dimensions 210mm H, 226mm Diameter
Warranty 5 years
Optional Available with built-in photo sensor
Available with built-in Alarm relay

Installation
Order Codes
Series Siger/Double AC/DC Flashing/stead Photo sensor Alarm relay
YML2000B s
S
D
S A
D
F
S
P R
AMS3080

For example YML2000CDASPRST means AC-YML2000B works in


Service+Standby With Photosensor with alarm relay output

REDDOT
YUAN AMP
SHENG mounting
AMS kitkit: Ordering
mounting : Ordering Code
Code AMS30150
Vertical tower leg Horizontal tower leg
Series diameter range diameter range
AMS3080
30-80mm 30-80mm

AMS30150 30-150mm 30-80mm

www.yssignal.com 12
YML2000C
OM2K LED Based
LED Based
MediumMedium
Intensity Obstruction Light
APPLICATIONS
YML2000C is a new generation medium intensity OB light. It uses
24 OSRAM LED,Compare with YML2000B it has more intensity
c o
better heat dissipation and efficiency is higher. p
l am
tlc towers power lines
C
buildings

Our products work is very stable under AC voltage from


110VAC
from 24Vtoto
240VAC
60V. Itcomes
Ourproducts
with compact-size
work under and
DC voltage
light-weight, which makes installation chimneys
wind turbinesjob flare stacks
from 48V to 60V. Itcomes with compact-size and light-weight, which makes installation job
nice & easy.
Features Standard
Unique optical design complies with ICAO ICAO Annex 14, 4th Edition, July 2004
regulation ICAO medium intensity type B & type C
Aluminum head provides good thermal FAA AC No. 150/5345-43F,2006
performance FAA type L864
Better shock-resistant perform than Xenon
Longer lifetime expectancy
Almost maintenance free
Lower voltage (than xenon) makes it safer
for installer
Cost effective in long run
5 years warranty

13 www.yssignal.com
Specifications
160
LIGHT OUT-PUT
Peak Intensity 2000 Candela
Vertical Divergence -1 950cd, Centering at 0.5
Horizontal out-put 360 Degree
LED Color Red
LED Lifespan 100,000 Hours

210
OPERATION
Flash Pattern Steady-burning or flashing
POWER SUPPLY
Input voltage 110VAC ~ 220VAC 48VDC-60VDC
Frequency 50Hz ~ 60Hz
Rated consumption 40W in
35W with steady
steady mode
mode
MECHANICAL STRUCTURE
Lens Polycarbonate, UV Stabilize
Body Die-casting Aluminum
Water-proof IP67
Weight 5 KG
Temperature Range -40 ~ +55
Relative humidity 100% with condensation 226
Dimensions 210mm H, 226mm Diameter
Warranty 5 years
Optional Available with built-in photo sensor
Available with built-in Alarm relay

Installation
Order Codes
Series Siger/Double AC/DC Flashing/stead Photo sensor Alarm relay
YML2000C S
s
S
D
A
D
F
S
P R
AMS3080

For example YML2000CDASPRST means AC-YML2000C works in


Service+Standby With Photosensor with alarm relay output

YUANSHENG AMS mounting kit : Ordering Code AMS30150


Vertical tower leg Horizontal tower leg
Series diameter range diameter range
AMS3080
30-80mm 30-80mm

AMS30150 30-150mm 30-80mm


Light Effective Intensity (candela)

Photometric Performance

2500
Peak Intensity 2000
2000
-1 Intensity 950
1500
YML2000 Data
1000
ICAO Maximum
500
Requirement
ICAO Minimum
0 Requirement
-5

-4

-3

-2

-1

-1

-2

-3

-4

-5

Vertical Divergence (degrees)

www.yssignal.com 14
YSL10 Solar Powered
Obstruction Light
The solar panel comes with YSL10 provides power supply to APPLICATIONS
the light, which makes YSL10 a self-contained and care-free
o
light unit. Also, with the solar function, the light is easy to
pc
deploy to almost any condition and any emergency case.
Robust body built and surface coating provides good l a mtlc towers power lines
protection against hash environments. C
buildings

it also can use in Offshore gas & oil platform

wind turbines chimneys flare stacks

YSL10 is equipped with an 8Ah NiMH rechargeable battery which could power the light up to 20 days
when the weather is cloudy & rainy. NiMH battery is also a clean power source with no pollution. The
NiMH battery is also easy to find almost anywhere.
YSL10 can increase the synchronous line of realizing multi YSL10 synchronous.Can increase the alarm
output.YSL10 is also available with an optional on/off switch for storing and protect battery from
overcharge and over-discharging.

Features
Ultra-light LEDs, energy saving
Self-contained without outside power supply
Maximum visibility distance 4 KM
Once fully charged, it can work for up to 200
hours
Auto-off after being packed for 18 hours

15
www.yssignal.com
Specifications 23.2

LIGHT OUT-PUT
Intensity FLASHING
Red: >10cd Green:>20cd Yellow: >10cd
White:>25cd Blue:>5cd 10.0
STEADY
Red: >4cd Green: >8cd Yellow: >4cd
White:>10cd Blue:>2cd

Nominal Night Range >4 KM


LED Color Available Red, Green, Yellow, White, Blue 204.5
Vertical Divergence 10 Degree
Horizontal Out-put 360 Degree
Illumination Ultra-bright LEDs
LED Lifespan 100,000 Hours
OPERATION
Autonomy Flashing : 200 Hours / Steady : 100 Hours
215.5
On & Off Level 70/100 Lux
Flash Pattern 40FPM defaultcan be preprogrammed to a
specified flashing rate upon customer request) 89 95.0

POWER SUPPLY
Power Source Solar module, mono-crystalline silicon
Solar Efficiency 13.5% 177.0
226.0
Max. Power Out-put 1.8 Watts
Battery Type High-efficiency NiMH rechargeable battery
Battery Capacity 8 AH / 3.6V Installation
Battery Replacement Yes, replaceable
MECHANICAL STRUCTURE
Lens Polycarbonate, UV Stabilize
Body Die-casting Aluminum
Water-proof IP67
Weight 3.5 KG
AMS3080
Temperature Range -40C ~ +55C
Dimensions 215.5mm H, 226mm Diameter
Warranty 5 years for light
2 years for NiMH battery

Note: when the light is in storage, please put it outside to charge the battery
every 3 months

YUAN SHENG AMS mounting kit : Ordering Code


Vertical tower leg Horizontal tower leg AMS30150
Series diameter range diameter range

AMS3080 30-80mm 30-80mm

AMS30150 30-150mm 30-80mm

www.yssignal.com 16
YSL10D Double Solar powered
Aviation obstruction light
Based on Yuansheng YSLL10,YSL10D is a ?twin? model which can be working synchronization. An internal
solar panel comes with each single light of YSL10D, provides power supply to the light, which makes
YSL10D a self-contained and care-free light unit. Also, with the solar function, the light is easy to deploy
to almost any condition and any emergency case. Robust body built and surface coating provides good
protection against hash environments.

YSL10D is equipped with an 8Ah NiMH rechargeable battery for each single which could power the light
up to 20 days in flashing mode when the weather is cloudy & rainy. NiMH battery is also a clean power
source with no pollution. The NiMH battery is also easy to find almost anywhere.

Features Application
Ultra-Bright LED, energy saving High-rise building marking
Self-contained without outside power supply Telecom tower marking
Maximum visibility distance 4 KM Road obstruction marking
Once fully charged, it can work for up to Navigation aid
200hours Port, dock entrance & walkway
Auto-off after being packed for 18 hours Buoy marking
Either single light fails will not affect the other Offshore gas & oil platform
normal working

1 2

4
5

1. Master light 4. 3*0.5mm2 shield cable


2. Slave light
5. IP68 4-pin cable connector
3. PG9 cable gland

17 www.yssignal.com
YSL32 Solar Powered
Obstruction Light
YSL32 With high efficiency, compact appearance and other advantages
also add External charging interface ,GPS synchronization Compliant
and Remote control function YSL32 is also available with an
ICAO (Annex 14) low intensity aviation light
optional on/off switch for storing and protect battery from
FAA-L810
overcharge and over-discharging.

Features

Self-contained without outside power supply


Maximum visibility distance 4 Nautical mile
External charging power is available( Optional).
256 kinds of flashing rate are available, comply with IALA
GPS synchronization(Optional).

Application

High-rise building marking


Telecom tower marking
Road obstruction marking
Navigation aid
Port, dock entrance & walkway
Buoy marking
Offshore gas & oil platform
Smokestacks

www.yssignal.com 18
Specifications 177

LIGHT OUT-PUT
Intensity FLASHING
Red: >32.5cd

Nominal Night Range >4 Nautical mile


LED Color Available Red, Green, Yellow, White, Blue

278
14998
Vertical Divergence 10 Degree
Horizontal Out-put 360 Degree
Illumination Ultra-bright LEDs
235
LED Lifespan 100,000 Hours
OPERATION
Autonomy Flashing : 200 Hours / Steady : 100 Hours
On & Off Level 70/100 Lux
Flash Pattern 40FPM defaultcan be preprogrammed to a
specified flashing rate upon customer request)
16
POWER SUPPLY
Power Source Solar module, mono-crystalline silicon
Solar Efficiency 13.5%
Max. Power Out-put 7.8 Watts
Battery Type High-efficiency NiMH rechargeable battery

200
Battery Capacity 16 AH / 3.6V
Battery Replacement Yes, replaceable
MECHANICAL STRUCTURE
Lens Polycarbonate, UV Stabilize
Body Die-casting Aluminum
Water-proof IP68 200
Weight 5.1 KG
Temperature Range -40C ~ +55C
Dimensions 278mm H, 235mm Diameter
Warranty 5 years for light
2 years for NiMH battery

Note: when the light is in storage, please put it outside to charge the battery
every 3 months

19 www.yssignal.com
YSL50 Solar Based Low
Intensity Obstruction Light
YSL50 Series
The solar panel comes with YSL50 provides power
supply to the light, which makes YSL50 a self-contained Intensity 50cd, flashing
and care-free light unit. Also, with the solar function, the ICAO: N/A
light is easy to deploy to almost any condition and any Compliant with
emergency case. Robust body built and surface coating FAA: N/A
provides good protection against hash environments.

YSL50 is equipped with an high-efficiency


rechargeable battery is also easy to find almost anywhere.

YSL50 is working under flashing mode, while ICAO requires


that the low intensity light to be steady. But, anyway,
YSL50 could be a alternative option for some special
needs.

Features
Ultra-light LEDs, energy saving
Self-contained without outside power supply
Maximum visibility distance 6 KM
Once fully charged, it can work for up to 200
hours
Auto-off after being packed for 18 hours

Application
High-rise building marking
Telecom tower marking
Road obstruction marking
Navigation aid
Port, dock entrance & walkway
Buoy marking
Offshore gas & oil platform

20
www.yssignal.com
Specifications 177

LIGHT OUT-PUT
Intensity Steady>50 Candela Flashing>200cd
Nominal Night Range >6 KM
LED Color Available Red
Vertical Divergence 10 Degree
Horizontal Out-put 360 Degree
Illumination Ultra-bright LEDs
LED Lifespan 100,000 Hours

448
324
OPERATION
Autonomy 200 Hours
On & Off Level 70/100 Lux
Flash Pattern Steady or Flashing (40 FPM as default)
POWER SUPPLY
Power Source Solar module, mono-crystalline silicon
Solar Efficiency 13.5%
Max. Power Out-put 20 Watts
Battery Type High-efficiency Lead-Acid rechargeable battery
Battery Capacity 12V / 13AH 235
Battery Replacement Yes, replaceable 16
MECHANICAL STRUCTURE
Lens Polycarbonate, UV Stabilize
Body Die-casting Aluminum
Water-proof IP67
Weight 13.5 KG

200
Temperature Range -40C ~ +55C
Dimensions 448mm H, 235mm Diameter
Warranty 5 years for light
2 years for Lead-Acid battery

Note: when the light is in storage, please put it outside to charge the battery
200
every 3 months

100
Light Effective Intensity (candela)

Photometric Performance
80

60

40

20

0
-5 0 5 10 15 20 25
Vertical Divergence (degrees)

21 www.yssignal.com
YSL2000Y Solar Powered LED Based
Medium Intensity Obstruction Light

YSL2000 solar powered LED medium intensity red YSL2000


obstruction light, solar self-contained design makes Intensity 2000cd, Flash
it easy to install any emergency case. Compliant with ICAO : Medium intensity type B
FAA : L-864
Robust body built and surface coating provides
DGAC Mexico
good protection against hash environments. Other
advantages like energy saving and cable saving make the solar powered light a good option
on obstruction marking.

YSL2000 is equipped with a 20W solar panel and 16Ah VRLA (Volve-Regulated Lead Acid)
rechargeable battery which could power the light up to 7 days when the weather is cloudy
&rainy.

Features
Green energy
Ultra-light LEDs, energy saving
Self-contained without outside power supply
Maximum visibility distance 20KM
Once fully charged, it can work for up to 90 hours
Cable cost saving & cabling job saving
No wiring job, nice & easy installation

Standard
ICAO Annex 14, 4th Edition, July 2004
ICAO medium intensity type B
FAA AC No. 150/5345-43F,2006
FAA type L-864
Application
Telecomm tower
Radio tower
Wind turbine
Somke stacks & chimney
Tall building
Power transmission line

22
www.yssignal.com
Specifications
LIGHT OUT-PUT
Intensity 2000 Candela
LED Color Available Red
Vertical Divergence 3 degree
Horizontal Out-put 360 degree
Illumination Ultra-bright LEDs
LED Lifespan 100,000 hours
OPERATION
Autonomy Flashing : 7 days(14 hours/day)
On & Off Level 70/100 Lux 177

Flash Pattern Flashing (40FPM as default)


POWER SUPPLY
Power Source Solar module, mono-crystalline silicon
Solar Efficiency 13.5%
Max. Power Out-put 20 Watts
Battery Type High-efficiency Lead-Acid rechargeable battery

448
324
Battery Capacity 16 AH / 12V
Battery replacement Yes, replaceable
MECHANICAL STRUCTURE
Lens Polycarbonate, UV Stabilize
Body Die-casting Aluminum
Water-proof IP67
Weight 15 KG
Temperature Range -40C ~ +55C
Light Dimensions 296mm H, 235mm Diameter
Solar Module dimension 306mm*420mm
Warranty 5 years for light
2 years for VARA battery

Note: when the light is in storage, please put it outside to


charge the battery every 3 months

ysl2000SeriesPhotometricPerformance

2500
PeakIntensity2000
LightEffectiveIntensity(candela)

2000
-1Intensity950
1500

YSL2000Data
1000
ICAOMaximumRequirement
ICAOMinimumRequirement
500

0
-1

-1
-2

-2
-3

-3
-5

-5
-4

-4
0

VerticalDivergence(degrees)

23 www.yssignal.com
CB04I Control Panel
Indoor Type
CB04I is a microprocessor indoor control panel device for monitoring and controlling obstruction
lights, mostly for telecom, GSM, Microwave and TV towers.

Connected with external photocell, the control panel will turn on/off automatically obstruction lighting
system from dusk to dawn. Even at day time, the control panel is still in monitoring status.
CB04I can be preprogrammed for different obstruction lighting configurations.

Features
Control up to four channels light output, each channel control up to four LED low intensity obstruc-
tion light or one LED low intensity double obstruction light.
Steady-burning and flashing mode adjustable by DIP switch
Auto/manual mode by DIP switch
Photocell with prewired shielded cable in five meters long
Transfer relay for service+standby double obstruction light system
LED indicator for lights, power, photocell operation status
Dry contact alarm output for lights and power
NO or NC alarm output contacts optional as customer alarm device type
35mm Din-rail mounting rail , easy to install

Specifications
Description Parameter
Input Voltage 85-265VAC, 50/60HZ
48VDC
24VDC
Power consumption 2W
Flash rate Steady-Burning/40FPM(default)
Photocell sensitivity 70/100Lux
Operating temperature -30+60
range

Enclosure PC
Protection class IP20
Dimension(HxWxDepth) 155x110x65mm
Weight 0.5kg

www.yssignal.com 24
CB02 Control Box
CB02 Control panel can provide extra functions in an Obstruction Light system and can control more than 1 light.

With control panel, the monitoring center can see real-time working status of the Obstruction Light system on each

tower. Any failure on these lights can be seen from monitoring center, and then field technician can be dispatched

to the site to fix the problem. The maintenance is very important to keep a clear open airway. The control panel

can support 110/220 AC power or DC48,DC24, DC12 low-voltage power supply, this makes the obstruction light
installation job becomes safer. The control box can be connected to a DC 48V supply. The flanges of the control
box enables easy mouting.

For example: CB02D4802O means out door type DC48V controller, can support 2 branchs aviation obstruction lights.

Functions & Features

* Easy installation.
* common alarm relay output.
* Built in auto maunal switch.
* Supplied with PG13.5 cable glands
* Aluminum alloy Enclosure, IP65, outdoor type.

25 www.yssignal.com
CB04O Control Box
CB04O control box is a microprocessor outdoor controller device for monitoring and controlling
obstruction lights, mostly for telecom, GSM, Microwave and TV towers.
Connected with external photocell, the control panel will turn on/off automatically obstruction lighting
system from dusk to dawn. Even at day time, the control panel is still in monitoring status.
CB04O can be preprogrammed for different obstruction lighting configurations.
Each branch of maximum power output of 40W, this product uses the current detection, a common
alarm relay output.
Features
MECHANICAL
Aluminum alloy Enclosure, IP67, outdoor type, good corrosion resistance
Circuit breaker switch, surge protection and terminal block are suitable for DIN rail mounting
The enclosure door is secured by four captive screws
Supplied with PG13.5 cable glands
Four threaded mounting holes in the back of control box, suitable for attaching to any vertical
surface or rack mounting.

ELECTRICAL
Control up to four channels light output, each channel control up to four LED low intensity
obstruction lights or one LED medium intensity beacon.
Steady-burning and flashing mode adjustable by DIP switch
Auto/manual mode by DIP switch
Photocell with prewired shielded cable in five meters long
Transfer relay for service+standby double obstruction light system
LED indicator for lights, power, photocell operation status
Dry contact alarm output for lights ,Photocell and power.
NO or NC alarm-common output alarm terminal
Overvoltage protection and MOV surge protection
Circuit breaker protection and fuse protection

Specifications
Parameter
Input Voltage 85-265VAC, 50/60HZ
48VDC 24VDC
Power consumption 10W
Flash rate Steady-Burning/40FPM(default)
Photocell sensitivity 70/100Lux
Operating temperature -30+60
range
Enclosure Aluminum alloy
Protection class IP67
Dimension(HxWxDepth) 320x219x104mm
Weight 3.9kg

www.yssignal.com 26
Typical System Application

H45M 45<H<90M
YML2000
45M<H<105M
YOL10D
YOL32D

YOL32S YOL32S
YOL32S
YOL10S YOL10S

JB

JB

BTS
BTS BTS

B
B
Alarm Power
Alarm Power
Alarm Power

Alarm mornitoring in BTS Alarm mornitoring in BTS


Alarm mornitoring in BTS

Obstruction light system for telecom T90-YOL10D2YOL10S 48VDC obstruction 1YML2000 3YOL32: Steady Medium
tower 45 meters lighting system for 45-90m tower intensity system

Double obstruction lighting system Functions & Features The height of structure more than 45meter but
less than 105m, should install medium intensity
Control one low intensity double light on the One unit of YOL10D double light on the top on the top level and low intensity at the
top intermediate level
height of tower Top level : 1 or 2 units medium
Under service+standby system, configured YOL10D double and YOL10S single lights are
transfer relay in the control box, in case of integrated into one junction box intensity(YML2000) red Steady
service lam failure, will transfer to standby Alarm output for double light Intermediate level : 3 units L-810 low
Alarm output for single lights level intensity(YOL32S) red steady burning, or 4
lamp
In Service+servicetype, either failure will Alarm output for power supply units if square tower
output signal to the control box Alarm output for Photocell
Note:
Photocell auto switch on/off the tower
Each level will be alarmed independently
obstruction lighting system from dusk to
Any OB light of Each level failure will output
dawn
alarm signal to control box

Wiring method
Please connect the power cord according to the label
instruction

N L

POWER
Power - controller power input Photocell - photocell control terminal
NO:1, NO:2, NO:3, NO:4 are 4 aviation
obstruction light indicators individully.

Green light means working fine. Red light AL1,


AL2, AL3, AL4 means corresponding light has
failed.

Please make sure all wiring job are correct.


Connecting the power supply, then the
Lamp1, Lamp2, Lamp3, Lamp4 - connect to aviation controller will start to work

alarm-common output alarm terminal

27 www.yssignal.com
CB20 Obstruction
Light Control Box
CB20
Basedcontrol box can
on CTR04B, add backup
CTR04-B20 battery,
control boxCB20 Controlwith
is designed Boxbackup
can givebattery,
alarm when
whichlight
can fault,
support
control light flashing frequency and on / off at dusk / dawn, also can be used in street light.
Compare with CB04O , CB20 each branch has a greater power output .
this product uses the current detection,Can display the current and voltage
Features
MECHANICAL
Built-in transfer relay for YOL32 doublelight(service+standby)
OL32 double light(service+standby)
LED indicator for lights, power, photocell operation status
Dry contact alarm output for light, power and battery
Both NO and NC alarm contacts are available
Surge protection for both input and output
Transient overvoltage protection and over-discharge protection
To display the total current and voltage
Application
> For Double Obstruction light system
> For 4-20 branchs system
Specifications
Description Parameter
Input voltage DC48V 85-265VAC, 50/60Hz
Output voltage 48VDC
Backup time with 20 hours 20 hours
REDDOT light 1 YOL32 double light 1 YOL32 double light
(Service+Standby) (Service+Standby)
Flash rate Steady-Burning/40FPM(default)
Photocell sensitivity 70/100Lux
Operating temperature range -30~+60
Enclosure Cold-Rolled steel sheet,
Ral-7035 Electrostatic Polyester

Protection class IP65


Dimension(HxWxDepth) 500x400x208mm
Weight 32kg

PHC01 Photocell YOL32D Double Light

www.yssignal.com 28
Aviation Obstruction Light

Other
Obstruction
OMARK Obstruction
Marking Marking
Sphere Sphere
Installation Accessories
Warranty Policy
ICAO Recommendation And Practice
Over Various Applications

29 www.yssignal.com
Obstruction
Marking Sphere
Aviation obstruction marking sphere is designed to provide daytime visual warning of electricity
transmission line for aircraft pilots, especially cross river high voltage transmission lines.

A marker should be of one colour. When installed, white and red, or white and orange markers should be
displayed alternately. The colour selected should contrast with the background against which it will be
seen.

Functions&Features
Not easy to break during transportation & installation
Super corrosion resistant character, stainless steel bolts and nuts
Aluminum alloy cable clamp guarantees good corrosion resistance

Application
Power transmission Line

Standard
ICAO Annex 14, 4th Edition, July 2004
FAA AC 70/7460-1K, obstruction Marking and Lighting

www.yssignal.com 30
Specifications
Operation
Visible Distance 1200 meters
Voltage Range 35KV-1000KV
Conductor diameter 6.5-55mm .0
600
Mechanical structure
Color Orange, Red, White, Orange/White, Red/White
Sphere body FRP(Fiberglass Reinforced Polyester)
Cable clamp Aluminum alloy
Bolts/nuts/washers
700
Stainless steel 304
Diameter 600mm
Weight 6.9KG
Thickness 3mm
Drain holes Yes

150
Optional Preformed Armor Rods
Reflective Strip
Warranty 2 Years

Ordering Code
Series Diameter Color Cable diameter(mm) Armor Rods Reflective Strip

600mm O(Orange) ___.___ AR RS

R(Red)

W(White)

O/W(Orange/White)

R/W(Red/White)

or Example, 600O13.1AR means a 600mm diameter warning sphere, orange color, with preformed
armor rods, suitable for diameter 13.1mm cable conductor.

Note :
For guarantee the spheres can fit for cable conductor well, customers need to provide cable diameter,
cable material and code.

31 www.yssignal.com
Installation Accessories

Single light mounting kit parts list


Ref No DESCRIPTION MATERIAL QUANTITY
1 Single lamp 1
2 Gasket Silicon 1
3 Fixed board SUS #304 1
4 6mm washer SUS #304 2
10
1 5 6mm spring washer SUS #304 2
11 6 M6 hex nut 2
2 SUS #304
12 7 3/4"joint SUS #304 1
3 8 Cable waterproof joint (PG13.5) PA66
13 1
4 9 M8 hex nut SUS #304 4
5 10 M6 25 hex bolt SUS #304 1
11 Support clip SUS #304 1
6 14
15 12 8mm spring washer SUS #304 4
7
13 8mm washer SUS #304 4
8 14 M8 U-bolt SUS #304 1
9 16 15 M6 Trapezoidal card SUS #304 1
16 Pipe 1

Pipe diameter range 30-80 mm Pipe diameter range 60-100 mm


AMU80 AMU100
Mounting kit for 30-80mm vertical or horizonal pipe Mounting kit for 60-100mm vertical l pipe
Ordering Code: AMU80 Ordering Code: AMU100

Pipe diameter range 30-60 mm Pipe diameter range 100-150 mm


AMU60 AMU150
Mounting kit for 30-60mm vertical pipe Mounting kit for 100-150mm vertical pipe
Ordering Code: AMU60 Ordering Code: AMU150

www.yssignal.com 32
23.2

Installation

10.0

204.5

AMP3080
AMS3080 AMP30150
AMS30150

216.5

89 95.0

177.0
226.0

33 www.yssignal.com
t Electron
do

ics
ghai Red
ANTY

Co., Ltd
Warranty Policy WARR Y
POLIC

an
Sh

Dear users, thank you for selecting products from Yuansheng Electronics Company.

Our products are warranted to be free from manufacturing defects in materials and workmanship starting from the date of
delivery. The actual warranty period of the product depends on the product category.

Limitation of Liability
The provisions of the warranty are in lieu of any other warranty, whether expressed or implied, written or oral.YuanSheng's
liability arising out of the manufacture, sale, or supplying of the product and its use, whether based on warranty, contract,
negligence, product liability, or otherwise, shall not exceed the original cost of the product. In no event shallYuanSheng
be liable for unintended or consequential damages, including, but not limited to, a loss of profits or use damages arising out
of the manufacture, sale, or supplying of the product.

Replacement
Due to the high rate of international air transportation and custom clearance paper works, we may not require customers to
return products as long as the customer could provide enough materials of the incorrect product. In that case, YuanSheng
will send out replacement product once our QC approved the application.

When a malfunction happens, please cooperate with our after-sales service staff with the detailed description of the scene
and malfunction. If necessary, please provide the photos of scene and malfunction product to us so that we can offer the
timely and effective service.
YuanSheng after-sales service staff is obligated to provide the failure analysis report to the customer.
.
Warranty Periods
Products Category Warranty Period
Light & control device 5 Years
Solar panel 10 Years
Rechargeable battery 2 Years
Accessory 1 Years

www.yssignal.com 34
Note
> Please make sure connect the product according to the wiring diagram on the category.

> For products containing rechargeable battery, YuanSheng normally give 2 years warranty on the battery unless there is
specific stating on the products category.

> For products containing solar panel & rechargeable battery, the batterys power may reduce to insufficient level during
storage and transit. In this case, please first put the product under sunlight at daytime for several days for battery charging
purpose.

> Product warranties remain valid provided the product was properly installed and used. Defects,
> malfunctions, or failures of the warranted product caused by damage resulting from acts of God (such as floods, fire, etc.),
environmental and atmospheric disturbances, other external forces such as power line disturbances, host computer
malfunction, plugging the board in under power, or incorrect cabling, and damage caused by misuse, abuse, and unauthorized
alteration or repair, are not warranted.

> For large order projects, customers may purchase an extended maintenance contract. Some parts may have a limited warranty
from the original supplier of the parts. Please contact YuanSheng's sales department if you would like to extend the maintenance
period of a YuanSheng product.

35 www.yssignal.com
Introduction
Aviation Obstruction light is a product to warn aircraft potential danger from above ground-
level structures like tower, smokestack, tall building, etc. In some cases, its also called Aircraft
Warning Light (AWL). When it comes with controller to realize extra functions like alarm
signal sending, flash synchronizing, and auto switch on at night, etc, it can also be called
Aircraft Warning Light System (AWLS).

Regulations
ICAO & FAA are two major international authorities that regulate obstruction light industry.
ICAO International Civil Aviation Organization
ICAO FAA Federal Aviation Authority

Some quote from ICAO Annex 14, chap. 6


6.1 The marking and/or lighting of obstacles is intended to reduce hazards to aircraft by
indicating the presence of the obstacles. It does not necessarily reduce operating limitations
which may be imposed by an obstacle.

6.3.1 The presence of objects which must be lighted, as specified in 6.1, shall be indicated y
low-, medium- or high-intensity obstacle lights, or a combination of such lights.

6.3.2 Recommendation. low-intensity obstacle lights, type A or B, should be used where the
objects is a less extensive one and its height above the surrounding ground is less than 45m.

6.3.7 Recommendation. medium-intensity obstacle light, type A, B or C, should be used


where the object is an extensive one or its height above the level of the surrounding ground
is greater than 45 m. medium-intensity obstacle lights, Types A and C, should be used alone,
whereas medium-intensity obstacle lights, Type B, should be used either alone or in combina-
tion with low-intensity obstacle lights, Type B.

ICAO Annex 14, chap. 6, Table6-3. Characteristics of obstacle lights

Peak intensity (cd) at given Background Luminance


Signal type
Light Type Color (flash rate) Above 50-500cd Below Vertical Beam
500cd / m2 / m2 50 cd / m2 Spread (c)
Low-intensity, Type A Red Fixed N/A 10 mnm 10 mnm 10
(fixed obstacle)
Low-intensity, Type B Red Fixed N/A 32 mnm 32 mnm 10
(fixed obstacle)
Low-intensity, Type C Yellow Flashing N/A 40 mnm (b) 40 mnm (b) 12 (h)
(mobile obstacle) Blue (a) (60-90 fpm) 400 max 400 max
Low-intensity, Type D Yellow Flashing N/A 200 mnm (b) 200 mnm (b) 12 (i)
Follow-me Vehicle (60-90 fpm) 400 max 400 ma x
Medium-intensity, White Flashing 20 000 (b) 20 000 (b) 2 000 (b) 3 mnm
Type A (20-60 fpm) 25% 25% 25%
Medium-intensity, Red Flashing N/A N/A 2 000 (b) 3 mnm
Type B (20-60 fpm) 25%
Medium-intensity, Red Fixed N/A N/A 2 000 (b) 3 mnm
Type C 25%
High-intensity, White Flashing 200 000 (b) 20 000 (b) 2 000 (b) 3-7
Type A (40-60 fpm) 25% 25% 25%
High-intensity, White Flashing 100 000 (b) 20 000 (b) 2 000 (b) 3-7
Type B (40-60 fpm) 25% 25% 25%

36
www.yssignal.com
Applicable FAA Advisory Circulars
AC 150/5345-43E Specification for Obstruction Lighting equipment
AC 70/7460-1 Obstruction Marking and Lighting
AC 150/5345-53 Airport Lighting Equipment Certification Program

Some quote from FAA AC 150/5345-43E


1.2 Equipment Classification

Type Description
L-810 Steady-burning red obstruction light
L-856 High in tensity flashing white obstruction light, 40 Flashes Per Minute (FPM)
FAA
L-857 High intensity flashing white obstruction light, 60 FPM

L-864 Flashing red obstruction light, 20-40 FPM

L-865 Medium intensity flashing white obstruction light, 40 FPM

L-866 Medium intensity flashing white obstruction light, 60 FPM

L-885 Flashing red obstruction light, 60 FPM

3.3.5.2.2 Monitoring.
Each separate L-864 light unit and each tier of L-810 light units shall be monitored for
FLASH/FAIL status. FAIL is defined as outage of any lamp in an L-864 light unit, outage of
any one lamp in a tier of L-810 light units, or failure of a flasher (steady on and/or total) for an
L-864 light unit. Monitor signals shall be fail safe (i.e., active signals for FLASH and absence of
signals for FAIL). There shall be a provision to permit connection to a remote alarm device,
(supplied by others or as an option) to indicate FLASH/FAIL status.

Some quote from FAA AC 70/7460-1K


Chapter 5, 51.b.
Double Obstruction Light. A double (L-810) light should be installed when used as a top light,
at each end of a row of single obstruction lights, and in areas or locations where the failure of
a single unit could because an obstruction to be totally unlighted.

Chapter 5, 52. CONTROL DEVICE


Red obstruction lights should be operated by a satisfactory control device (e.g., photo cell,
timer, etc.) adjusted so the lights will be turned on when the northern sky illuminance
reaching a vertical surface falls below a level of 60 foot-candles (645.8 lux) but before
reaching a level of 35 foot-candles (367.7 lux). The control device should turn the lights off
when the northern sky illuminance rises to a level of not more than 60 foot-candles (645.8
lux). The lights may also remain on continuously. The sensing device should, if practical, face
the northern sky in the Northern Hemisphere. (See AC 150/5345-43.)

37 www.yssignal.com
ICAO Recommendation And Practice
Over Various Applications

Tower
Height Night only operation Day and Night

Below 45 meters Plan A: 2 low intensity type A or B at the top


Plan B: 2 low intensity type B at the top
3 low intensity type B at intermediate level(s)
every 45 meters on the periphery of the tower

45 m. up to Plan A: 2 low intensity type B at the top 1 or 2 white medium intensity


105 meters 3 low intensity type B at intermediate level(s) type A at the top.
every 45 meters on the periphery of the tower.

Plan B: 1 or 2 medium intensity lights type B at the


top. 3 low intensity lights type B at intermediate
levels at 120

Plan C: medium intensity type A or C, use alone


Above 105 meters 1 or 2 medium intensity lights type B at the top. 1 or 2 white medium intensity type
A (white) at the top. 3 medium
3 low intensity lights type B at intermediate levels ntensity type A at intermediate
at 120. levels.
Above 150 meters 3 high intensity lights at 120 every 150 meters.

Tall buildings Height Night only operation Day and Night

Below 45 meters Low intensity type A or B lights at each edge of


building and at regular interval every 45 meters.

Above 45 meters Plan A: Low intensity type A or B lights at each 1 or 2 white medium intensity
edge of building and at regular interval every 45 type A (white) at the top.
meters. Intermediate lights every 45 meters. In case of a building exceeding
900 m. length, additional lights
Plan B: medium intensity type B lights at each should be installed at the edge
edge of building and at regular interval every 45 of the building.
meters. Low intensity light at intermediate level,
every 45 meters.

Wind turbines Night only operation Day and Night

1 or 2 medium intensity type B (red) located on 1 or 2 medium intensity type A (white) located on the
the top of the turbine. In case of a group of top of the turbine. In case of group of windmills,
windmills, additional lights at the circumference additional lights at the circumference of the farm
of the farm every 450m and synchronized. every 900m and be synchronized.

www.yssignal.com 38
Cranes Height Night only operation Day and Night

Below 45 meters 3 low intensity type A or B lights on the jib,


counter jib and crane-top.
45 meters up to 3 medium intensity lights type B at the top on the 1 or 2 white medium intensity type
105 meters A (white) on the crane-top.
jib, counter jib and crane-top.
In case of more than one crane,
3 low intensity lights type B at the intermediate additional lights should be installed
levels. and synchronized.

Above 105 meters 1 or 2 red medium intensity type B on the 1 or 2 red medium intensity type A
on the crane-top.
crane-top.
In case of more than one crane,
In case of more than one crane additional lights additional lights should be installed
should be installed and synchronized and synchronized.

Above 150 meters 3 high intensity lights on the crane top

Chimney Height Night only operation Day and Night

Below 45 meters 3 up to 4 low intensity type A lights placed 1,5


meters up to 3 meters below the to avoid
smokes to hide the lights.

3 up to 4 medium intensity type B lights placed 3 up to 4 white medium intensity


45 meters up to
lights type A placed 1.5 meters up
105 meters 1.5 meters up to 3 meters below the top. 3 up to
to 3 meters below the top.
4 low intensity type B lights at intermediate
level(s) 45m.
Above 105 meters 3 up to 4 medium intensity type B (red) placed 3 up to 4 white medium intensity
1.5 meters up to 3 meters below the top. lights type A placed 1.5 meters up
to 3 meters below the top.
3 up to 4 low intensity type B every 45m. 3 up to 4 white medium intensity
lights type A at intermediate levels.

Above 150 meters 3 high intensity lights at 120 every 150 meters.

Transmission
Night only operation Day and Night
lines
Tower light 2 low intensity type A or B lights at the top of
each tower.

39 www.yssignal.com
Add : 18 Telixi Road, xingsha, changsha, China 84879826
Tel : +86 731
WebSite : www.yssignal.com E-mail : sunny@yssignal.com

Você também pode gostar