Você está na página 1de 3

Page 1 of 3

Chemrite AG - 200
High Range Water-Reducing and Slump Retaining Concrete Admixture
___________________________________________________________________________________________________
Product Chemrite AG 200 is a highly effective liquid
Description superplasticizer for the production of free flowing
concrete which prolongs slump retention at low
water-cement ratios.
___________________________________________________________________________________________________
Uses Chemrite AG 200 is used as a superplasticizer in
concrete works such as
- Slabs and Foundations
- Walls, Columns and Piers
- This structural elements with densely packed
reinforcement.
- Hot-weather concreting.
- High strength concrete
- Pre-cast concrete
- Pre stressed concrete
- Bridges, Roads & Pavements
- High - rise Buildings
- Long-haul transportation of ready-mixed concrete.
__________________________________________________________________________________________________
Characteristics/ Chemrite AG 200 provides the following
Advantages advantages:
- Improved workability at reduced water content.
- Reduced segregation/bleeding
- Improved surface finish
- Reduced shrinkage and creep
- Upto 25% water reduction resulting in higher ultimate
strength.
___________________________________________________________________________________________________
Tests Chemrite AG 200 complies with ASTM C 494:
Types B, D&G
___________________________________________________________________________________________________
Product Data
___________________________________________________________________________________________________
Form Brown Liquid
___________________________________________________________________________________________________
Packaging 200 Lit drums.
Bulk supply in tanker possible on demand
___________________________________________________________________________________________________
Storage
___________________________________________________________________________________________________
Shelf Life 12 months from date of production if stored
properly in undamaged and unopened original
sealed containers.
___________________________________________________________________________________________________
Storage In dry conditions at temperatures between +5C and
+30C. Protect from direct sunlight and frost.
___________________________________________________________________________________________________

1
Page2 of 3
___________________________________________________________________________________________________
Technical Data
__________________________________________________________________
Chemical Base Sulphonated naphthalene based
__________________________________________________________________
Density (25C) 1.18 0.01 Kg/Lit
__________________________________________________________________
Chloride Content Nil
__________________________________________________________________
Consumption/ Dosage Recommended dosage 0.8-2.0% by weight of
cement. It is advisable to carry out trial mixes to
establish the correct dosage. Higher dosage can be
used depending on the mix design & concrete
requirement. A pre-trial to confirm the dosage
by the user is recommended.
__________________________________________________________________
Compatibility Chemrite AG 200 may be combined with many
other products particularly
- Chemrite Ferrogard 110
- Silica Fume
- Sulphate - resistant cement.
- Slag cement.

Trials must be performed before combining products in a


concrete mix.
__________________________________________________________________
Application
Instructions
__________________________________________________________________
Dispensing Chemrite AG 200 is added to the gauging water
at the plant or added on site into the concrete mixer.
Allow enough mixing time for the concrete to
achieve uniformity.
__________________________________________________________________
Application Method/ The standard rules of good concreting practice are
Tools to be followed.
Fresh concrete must be cured properly, especially at
high temperatures in order to prevent plastic and
drying shrinkage. Use Chemsol curing agents
preferably.
__________________________________________________________________
Cleaning of Tools Clean all tools and application equipment with
water immediately after use. Hardened/cured
material can only be removed mechanically.
__________________________________________________________________

2
Page 3 of 3
__________________________________________________________________
Health and Safety
__________________________________________________________________
Protective Measures To avoid allergic reactions, wear protective gloves.
In case of contact with eyes, rinse immediately with
clean water and seek medical attention without
delay.
__________________________________________________________________
Ecology Do not dispose off into water or soil but according
to local regulations.
__________________________________________________________________
Toxicity Non Toxic.
__________________________________________________________________