Escolar Documentos
Profissional Documentos
Cultura Documentos
PROJECT/LOCATION:
CONSTRUCTION/ REHABILITATION OF
MULTI PURPOSE BUILDING,
THREE (3) STOREY MPB,
BRGY. ST. JOSEPH, SAN JUAN CITY
CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS SET NO.: SHEET NO.:
ARCHITECT II ENGINEER II OIC/CHIEF, PLANNING & DESIGN SECTION OIC/ASST. DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
A-1
SJN
SCOPE OF WORK
P E R S P E C T I V E
1 2 3 4 5
4
3
B
2
N
SLOPE
SLOPE
C
SLOPE
UP
RAMP UP
1 5
S I D E W A L K S I D E W A L K
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: CHECKED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, A-2
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
1 2 3 4 5 1 2 3 4 5 1800
800 (DOOR WIDTH)
550
2 2
450
300mmx500mmx100mm THK. 300mmx500mmx100mm THK. F F F
CONCRETE CANOPY A-4 A-5 CONCRETE CANOPY A-4 A-5 F F
2700
2550
05 02 05
2150
2150
F F
TOILET TOILET
B B W
W W
03
05 05 FFL FFL FFL
D D
3 SETS 1 SET 1 SET
04 04 D 900mm X 2450mm
D 800mm X 2150mm
D 1600mm X 1800mm DOUBLE SWING
KITCHEN KITCHEN
01 PANEL TYPE SWING DOOR 02 PANEL TYPE SWING DOOR 03 FRAME LESS GLASS DOOR
MULTI-PURPOSE MULTI-PURPOSE W/ FIXED CURVE TRANSOM W/ FIXED TRANSOM
C AREA A
C AREA C AND FIXED GLASS WALL
3 STO.
2 3 2
A-4 A-4 A-4 A-4 700 (DOOR WIDTH)
1250
D D
D D
FFL FFL
01 01
1
4 SETS 1 SET
A-4 D D
CONCRETE LEDGE 700mm X 2150mm 600mm X 1250mm
EXISTING FENCE 04 FLUSH TYPE SOLID 05 FLUSH TYPE SOLID
ROOF LINE CORE DOOR CORE DOOR
1 2 3 4 5 1 2 3 4 5
4 EQUAL PARTS = 2400 2 EQUAL PARTS = 1200
F F F F F F
4 2 4 2
300mmx500mmx100mm THK.
CONCRETE CANOPY A-4 A-5 A-4 A-5
1150
1150
.40mmTHK. PRE-PAINTED
A A ORDINARY FLASHING
W
05
900
900
.40mmTHK. PRE-PAINTED
STEEL TILE ROOFING
TOILET FFL FFL
B W B .40mmTHK. PRE-PAINTED
W GUTTER
03 W 6 SETS
W 3 SETS
SLOPE
05 BRGY. CAPTAIN'S 2400mm X 1150mm
1200mm X 1150mm
D OFFICE 01 4 PANEL ANALOC SLIDING WINDOW 02
2 PANEL ANALOC SLIDING WINDOW
WITH FIXED TRANSOM
04 WITH FIXED TRANSOM
KITCHEN
SLOPE
C C
3 W D 2 3 2 4 EQUAL PARTS = 2400 2 EQUAL PARTS = 900 WIDTH 400
A-4 05 04 A-4 A-4 A-4
TOILET SECRETARY
AREA
400
500
W
600
EXTERIOR WALL LINE
03 SLOPE
UP DN D
1 1
03
1650
A-5
1550
W W W W
1450
RAILING D A-5
04 01 01 02 01
D D
TERRACE .40mmTHK. PRE-PAINTED FFL FFL FFL
ORDINARY RIDGE ROLL
2 SETS 7 SETS
CONCRETE LEDGE
W 4 SETS W 900mm X 500mm
W 400mm X 400mm
03 2400mm X 600mm 04 05
2 PANEL ANALOC ANALOC
4 PANEL ANALOC SLIDING WINDOW
SLIDING WINDOW AWNING WINDOW
CONCRETE BALUSTER 2ND FLOOR TERRACE
LEGEND:
2 SECOND FLOOR PLAN 4 ROOF PLAN FLOOR FINISHES WALL FINISHES 6 WINDOW SCHEDULE
A-3 SCALE 1:75 A-3 SCALE 1:75 CERAMIC UNGLAZED TILES 150mm THK. CHB W/ PLAIN CEMENT A-3 SCALE 1:50
FF 01 400mm x 400mm WF 01 PLASTER FINISH (PAINTED)
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: CHECKED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, A-3
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
1 2 3 4 5 D C B A
F F F F F F F F
N.G.L. N.G.L.
A B C D 5 4 3 2 1
N.G.L. N.G.L.
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: CHECKED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, A-4
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
1 2 3 4 5
ROOF APEX
ROOF FRAMING
(SEE TRUSS DETAILS)
DOME STRAINER
100mm x 50mm THK.
WINDOW SILLS AND TRIMS
4.5mm THK. CEMENT FIBER
1 LONGITUDINAL SECTION
A-5 SCALE 1:75
0.40mm PRE-PAINTED
LONGSPAN RIB TYPE
D C B A ROOFING SHEET
0.40mm FLASHING
ROOF APEX
ROOF FRAMING
(SEE TRUSS DETAILS)
4.5mm THK. CEMENT FIBER
LEVEL 3 F.F.L.
235mm HEIGHT
SIGNAGE METAL LETTERS
F F F
CONCRETE TOP RAIL
BRGY. CAPTAIN'S
5 EAVES DETAIL
PAINTING FINISH A-5 SCALE 1:10
OFFICE
CONCRETE BALUSTER F F
CONCRETE BOTTOM RAIL
LEVEL 2 F.F.L.
MULTI-PURPOSE
AREA A
EXISTING FENCE TO REPAINT
LEVEL 1 F.F.L.
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: CHECKED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, A-5
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
1 2 3 4 5 1 2 3 4 5
C1 C1
1
B-
FTB-2
FTB-1
B
B-4
B
B-1
B-1
B-1
PC-1 PC-1 B-2
-1
1
B-
B
FT
B-4
B-1 C2 G-1 G-1 C2
C C
C1/F4 FTB-2 C2/F4 C2/F3 C1 B-4
B-3
FTB-2
FTB-2
FTB-1
B-1
B-1
B-1
B-1
B-1
B-4
B-4
B-3
B-1
B-4 C1 C1 B-1 C2 C1 B-4
D D
B-4
C1/F1 FTB-2 C1/F1 FTB-2 C2/F1 FTB-2 C1/F1 B-1 B-1
B-4 B-4 B-4
4 C-1/F-1 DETAIL 4 C-1/F-2 DETAIL 4 C-1/F-3 DETAIL
S-1 SCALE 1:50 S-1 SCALE 1:50 S-1 SCALE 1:50
EXISTING FENCE T= 100mm + FINISH w/
NOTE:
1 2 3 4 5 6@100mm;REST @ 300mm
10
S-1
C1
C-1 DETAIL
SCALE 1:25
11
S-1
C3
C-2 DETAIL
SCALE 1:25
14
S-1
PC-1 DETAIL
SCALE 1:25
B
B-4
B-1
B-1
B-1
PC-1 B-2
C2 C2 C2 C1 C2
8 FTB-1 DETAIL
1
B-
B-4
B-1 C2 G-1 G-1 C2
C
C1 B-4
B-3
B-1
B-1
B-1
B-1
B-1
B-4
B-4
B-3
B-4 B-4
B-1
B-1
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: CHECKED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, S-1
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
NOTE:
5@100mm;3@150mm;REST@300mm O.C.
TOP OF
FLOORING
286
236 50
AT SUPPORT AT MIDSPAN AT SUPPORT AT MIDSPAN AT SUPPORT AT MIDSPAN AT SUPPORT AT MIDSPAN AT SUPPORT AT MIDSPAN
G-1 DETAIL B-1 DETAIL B-2 DETAIL B-3 DETAIL B-4 DETAIL
12
1 2 3 4 5
5
S-2 SCALE 1:25 S-2 SCALE 1:25 S-2 SCALE 1:25 S-2 SCALE 1:25 S-2 SCALE 1:25
200
FFL
100
100
100 400
11 SECTION DETAIL A
S-2 SCALE 1:20
C D
ROOF FRAMING
(SEE TRUSS DETAILS) B-2
TOP OF ROOF BEAM 286
236 50
12
5
LEVEL 3 F.F.L.
1 1 1
A-6 A-6 A-6 F F
200
LANDING
1 2 1 2 1 2
F F
LEVEL 2 F.F.L.
D D D
12 SECTION DETAIL A
STO. S-2 SCALE 1:20
8 24
7 9 23 25
6 10 22 26
5 21 11 21 27
4 20 12 20 28
3 19 13 19 29
2 18 14 18 30 LEVEL 1 F.F.L.
1 17 15 17 31
UP UP 16 DN 32 DN
N.G.L.
1200
50mm DEPTH DRILLED HOLES
E E E
125
10 STAIR SECTION
S-2 SCALE 1:75
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: CHECKED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, S-2
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
1 2 3 4 5
A 8 9
C1 T-4 T-4 C2 C1 S-3 SCALE 1:10 S-3 SCALE 1:10
-1
C4
RB
RB-1
B
RB-1
RB-1
T-1
PC-1
-1 T-2 T-2
RB
RB-1
C
T-1
C1 C2 C2
RB-1
3
T-
T-
3
T-5 T-5
RB-1
RB-1
AT SUPPORT AT MIDSPAN
10 11
2 RB-1 DETAIL S-3 SCALE 1:10 S-3 SCALE 1:5
T-5
T-5
C1 C1 C2 C1 S-3 SCALE 1:25
D
RB-1 RB-1 RB-1
12
S-3 SCALE 1:10
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: CHECKED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, S-3
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE MANUEL Y. MADRID LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III
ELECTRICAL NOTES
LEGEND:
1. ALL ELECTRICAL NOTES SHALL BE DONE IN ACCORDANCE WITH
THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE
FLUSH MOUNTED, NEMA 1 ENCLOSURE WITH PIN LIGHTS
ELECTRICAL CODE, EXISTING APPLICABLE ORDINANCES, RULES
GROUND TERMINAL
SERVICE ENTRANCE AND REGULATIONS OF THE LOCAL GOVERNMENT AND WITH THE
M 1 T-5, 1-128W FLUORESCENT LAMP REQUIREMENTS OF THE LOCAL POWER COMPANY.
CKT. MIRRORIZED WITH LOUVER RECESSED TYPE 2. THE TYPE OF POWER SUPPLY SHALL BE SINGLE PHASE, 220V,
LOAD DESCRIPTION VA VOLTS SIZE OF HOMERUN WIRES AND CONDUITS 2-22mm THHN + 1- 3.5mm TW(G)
NO. 2-WIRE, 60HZ A.C.
FRAME POLE TRIP IN 1 21
T-5, 2-128W FLUORESCENT LAMP 3. ALL WIRINGS SHALL BE INSTALLED IN STANDARD RIGID STEEL
PANEL BOARD 2 MIRRORIZED WITH LOUVER RECESSED TYPE CONDUITS RUN EMBEDDED INSIDE THE CONCRETE AND HOLLOW
LPA 1 LIGHTING OUTLET 640 220 50 AF 2P 20 AT 2- 3.5mm THHN + 1- 3.5MM BLOCKS STRUCTURES, SLABS, COLUMNS, WALLS, PARTITIONS
DUPLEX WEATHERPROOF OUTLET,
GROUNDING TYPE 15AMP., 230 VOLTS AND/OR CONCEALED BETWEEN DOUBLE WALL WOODEN
LPA 2 LIGHTING OUTLET 520 220 50 AF 2P 20 AT 2- 3.5mm THHN + 1- 3.5MM 100 AT, 2P PARTITIONS AND INSIDE THE CEILING SPAES. WHERE THE USE OF
CF CEILING FAN CONCEALED CONDUIT WIRING IS IMPRACTICABLE, SURFACE METAL
20AT, 2P 20AT, 2P MOULDING MAY BE USED
LPA 3 LIGHTING OUTLET 600 220 50 AF 2P 20 AT 2- 3.5mm THHN + 1- 3.5MM 4. UNLESS OTHERWISE INDICATED IN THE PLANS, THE MINIMUM SIZES
1 2 S ONE GANG DEVICE SWITCH OF WIRE AND RIGID STEEL CONDUIT TO BE USED SHALL BE 2.0mm2
LPA 4 CONVENIENCE OUTLET 2200 220 50 AF 2P 30 AT 2- 5.5mm THHN + 1- 3.5MM 20AT, 2P 30AT, 2P AND 15mm DIAMETER, RESPECTIVELY.
S TWO GANG DEVICE SWITCH
5. ALL LIGHTING CIRCUIT HOMERUNS AND CONVENIENCE OUTLETS
LPA 5 CONVENIENCE OUTLET 2200 220 50 AF 2P 30 AT 2- 5.5mm THHN + 1- 3.5MM 3 30AT, 2P 30AT, 2P
4 SHALL BE WIRED WITH NOT LESS THAN 3.5mm2 TW IN SIZE, UNLESS
OTHERWISE INDICATED ON THE PLANS.
S3 THREE GANG DEVICE SWITCH
6. WHEREVER REQUIRED AND NECESSARY, PULL BOXES AND
LPA 6 CONVENIENCE OUTLET 2200 220 50 AF 2P 30 AT 2- 5.5mm THHN + 1- 3.5MM 5 6 JUNCTION BOXES OF PROPER SIZES SHALL BE INSTALLED AT
30AT, 2P 30AT, 2P 2-3 SF FAN CONTROL SWITCH CONVENIENT AND INCONSPICUOUS LOCATIONS, ALTHOUGH SUCH
BOXES ARE NOT SHOWN ON THE PLANS NOR MENTIONED IN THE
LPA 7 CEILING FAN OUTLET 1000 220 50 AF 2P 30 AT 2- 5.5mm THHN + 1- 3.5MM 7 30AT, 2P 30AT, 2P
8 S 3W 3-WAY DEVICE SWITCH SPECIFICATIONS
7. ALL NON-CURRENT METAL PARTS OF EQUIPMENT/DEVICES SUCH
LPA 8 CEILING FAN OUTLET 800 220 50 AF 2P 30 AT 2- 5.5mm THHN + 1- 3.5MM PANEL BOARD AS PANELBOARD ACB AND THE LIKE SHALL BE PROPERLY
9 10 GROUNDED IN ACCORDANCE WITH THE PROVISIONS OF ARTICLE 4,
1 CIRCUIT HOMERUN PHILIPPINE ELECTRICAL CODE.
LPA 9 AIRCON OUTLET 2000 220 50 AF 2P 30 AT 2- 5.5mm THHN + 1- 3.5MM 8. ALL WALL OUTLETS SHALL BE INSTALLED AT THE FOLLOWING
GROUND TERMINAL BLOCK HEIGHTS ABOVE THE FINISHED FLOOR LEVEL, UNLESS OTHERWISE
GROUNDING SYSTEM
CEILING FAN OUTLET 1000 220 50 AF 2P 30 AT 2- 5.5mm THHN + 1- 3.5MM NOTED:
M ELECTRIC SERVICE METER a. WALL SWITCHES 1200mm
8.0 mm TW WELD IN 20mm
_ _ _ _ _ b. CONVENIENCE OUTLET 300mm
SPARE 1500
16mm x 2.40mm COPPER WELD SERVICE ENTRANCE WITH CAP c. FIRE ALARM STATION OUTLET 1500mm
GROUND ROD WITH HEAVY d. PUSH BUTTON OUTLET 1200mm
TOTAL CONNECTED LOAD RACEWAY CONDUIT CONCEALED IN CEILING 9. ALL ELECTRICAL WORKS/INSTALLATIONS SHALL BE DONE IN
DUTY CLAMP
RACEWAY CONDUIT CONCEALED STANDARD WORKMANSHIP MANNER WITH SKILLED MANPOWER
4 PANEL BOARD UNDER GROUND OR UNDER FLOOR DULY SUPERVISED BY A LICENSED ELECTRICAL ENGINEER.
USE: 2-22mm THHN + 1- 3.5mm TW(G) IN 1 21 E-2 SCALE NTS.
|L = (.85) (14,460/230) = 53.43 AMPERES M SERVICE METER
PROTECTION: 100 AT, 2P, 100 PF, 230 V, 60 Hz
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
A A A
TOILET
B 2 2 B 2 2 B 2 2
S S S
S S BRGY. CAPTAIN'S S
OFFICE
S S2S3 S S 3W S2 S S 3W S2 S3
D D D
M
TERRACE
LPA
2
EXISTING FENCE
PROJECT TITLE / LOCATION: SHEET CONTENTS: PREPARED BY: ELECTRICAL PREPARED BY: SUBMITTED BY: REVIEWED BY: RECOMMENDING APPROVAL: SET NO.: SHEET NO.:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
NATIONAL CAPITAL REGION CONSTRUCTION/ REHABILITATION OF AS SHOWN
MULTI PURPOSE BUILDING, E-1
METRO MANILA 1st DISTRICT ENGINEERING OFFICE THREE (3) STOREY MPB, SJN
WEST BANK ROAD, MANGGAHAN FLOODWAY
BRGY. ST. JOSEPH, SAN JUAN CITY CRISTINA L. JOSE ANTHONY C. GONZALES LUISITO C. PONCIANO EULOGIO V. YDIO ROBERTO S. NICOLAS
ROSARIO, PASIG CITY ARCHITECT II ENGINEER II OIC - CHIEF, PLANNING & DESIGN SECTION OIC - ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
ENGINEER III