Use 0.4--0.6Mpa test compressed air, without water, to avoid water pollution and
corrosion, it is environmental friend and clean, and improve quality of products.
The test period: 20-35 seconds / pcs(every working position).
2 ASSEMBLY PART
0574-63077646/13777004313 : 0574-63077648
/ /H
code name capacity per team Work hours remark
2 people per
1 4000 pcs per team 8
angle valve team
2 people per
2 5000 pcs per team 8
tap team
Remark: this data is according to the real production of clients
1 2
B test demand
place final product on the clamp 1
1 12 cavity 1 air inlet (to test if cavity
1 have leakage, and test partition between 1 and 2 at the same time)
qualified open spool 1 cavity 1 air inlet
12 test if cavity 1 or 2 have leakage
0574-63077646/13777004313 : 0574-63077648
..
2, the test machine begin to test the water inlet chamber, the partition between
water inlet and the water outlet chamber, automatically open the spool to start
3, if unqualified, the alarm on, air exhaust, the cylinder reset, and shows which
0574-63077646/13777004313 : 0574-63077648
parameter set
1#
st
parameter set of 1 working position Factory set value
1#
1 1# water inlet cavity maximum leakage pressure 12mbar
difference
1#
2 1# water outlet cavity maximum leakage 12mbar
pressure difference
1#
3 12mbar
1# Maximum leakage value of partition
1#
4 1# after spool open the maximum leakage 12mbar
pressure difference
1#
5 1500mbar
1# minimum working pressure
1#
5 1# When spool is closed, the air inlet time of 30(3s)
the water inlet chamber.
1#
6 1# When the spool is closed, the pressure 50(5s)
keeping time of the water inlet cavity.
1#
7 1# When spool is closed, the test time of the 30(3s)
water inlet chamber.
1#
8 1# When spool is closed, the air inlet time of 30(3s)
the water outlet chamber.
1#
9 1# When the spool is closed, the pressure 50(5s)
keeping time of the water outlet cavity.
1#
10 1# When spool is closed, the test time of the 30(3s)
water outlet chamber.
1#
11 30(3s)
1# When spool is open, the air inlet time.
1#
12 1# When spool is open, the air pressure keeping 50(5s)
time.
0574-63077646/13777004313 : 0574-63077648
1#
13 20(2s)
1# When spool is open, the test time.
1#
14 30(3s)
1# air exhausts time.
1#
15 20(2s)
1# partition test time.