WOOD-BASED PANELS
DEFINITIONS, REQUIREMENTS AND TEST METHODS
www.latea.lv
GLOSSARY
www.latea.lv
DEFINITIONS
WINDOWS AND DOORS ACCORDING TO EN 145351-1
www.latea.lv
WINDOW - FUNCTIONS
IMPACT ON WINDOW
www.latea.lv
EN 14351-1, PERFORMANCE OF WINDOWS AND DOORS
SUMMARY
www.latea.lv
EN 14351-1
RELEVANT CLAUSES, PERFORMANCE CHARACTERISTICS, ANNEX ZA1
www.latea.lv
EN 14351-1
ATTESTATION SYSTEM
ROOF WINDOWS
DEPENDING ON USE OF RW AS SUBJECT TO FIRE REACTION OR NOT
SYSTEM 1-4
www.latea.lv
EN 14351-1
ATTESTATION SYSTEM
www.latea.lv
WINDOWS AND DOORS
TESTING AND DOCUMENTATION
www.latea.lv
WINDOWS AND DOORS
FACTORY PRODUCTION CONTROL
www.latea.lv
WINDOWS AND DOORS
INITIAL TYPE TESTING
CASCADING ITT
www.latea.lv
WINDOW MAIN TYPES
INITIAL TYPE TESTING
2. BALCONY DOORS
www.latea.lv
WINDOWS AND DOORS SPECIAL TYPES, OTHER
INITIAL TYPE TESTING
www.latea.lv
WINDOWS AND DOORS
DECLARATION OF PERFORMANCE AND CE
www.latea.lv
WINDOWS AND DOORS
TESTING PROCEDURES
www.latea.lv
WINDOWS AND DOORS
TEST METHODS AND CLASSIFICATION
www.latea.lv
WINDOWS AND DOORS TEST METHODS
RESISTANCE TO WIND LOAD, WATERTIGHTNESS, AIR PERMAEBILITY
Test process:
ONE SAMPLE IN ONE RUN THREE CHARACTERISTICS
Overpressure
50 cycles
time
With step 100Pa rising pressure
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
RESISTANCE TO WIND LOAD
Assesment of characteristics:
Test accord to EN 12211 (mandatory test for windows system)
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
RESISTANCE TO WIND LOAD
Measurement of frame Wind load +/- at pressure P2, Safety test +/- at pressure P3,
Class deflection at pressure P1, Pa Pa Pa
0 npd
1 400 200 600
2 800 400 1200
3 1200 600 1800
4 1600 800 2400
5 2000 1000 3000
Exxx xxx
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
WATERTIGHTNESS
Test method:
EN 1027 (mandatory test for windows system).
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
WATERTIGHTNESS
PROCESS A:
NON-SHIELDED
PROCESS B:
SHIELDED
A NON-SHIELDED
B SHIELDED
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
WATERTIGHTNESS
CLASSIFICATION
Test pressure (Pa) Process A Process B
NON-SHIELDED SHIELDED
- NPD NPD
0 1A 1B
50 2A 2B
100 3A 3B
150 4A 4B
200 5A 5B
250 6A 6B
300 7A 7B
450 8A -
600 9A -
> 600 Exxx -
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
AIR PERMAEBILITY
Test method:
EN 1026 numerical average of + and pressure
(mandatory test for windows system)
- on length of joint m/hm, - on overall area m/hm.
RESULT AIR PERMEABILITY AT 100 Pa
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
AIR PERMAEBILITY
Air permaebility
on length of joint, on overall area, maximum test pressure, Pa
Class m/hm m/hm
0 npd
1 12,5 50 150
2 6,75 27 300
3 2,25 9 600
4 0,75 3 600
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
THERMAL TRANSMITTANCE
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
THERMAL TRANSMITTANCE
Evaluation UW by calculation:
According to EN ISO 10077-1.
Ag = Glazing area, m2
Ug = U glazing, W/mK
Af = Frame area, m2
Uf = U frame, W/mK
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
THERMAL TRANSMITTANCE
Evaluation UW by calculation:
According to EN ISO 10077-1.
Sample:
AgUg + AfUf + lgg
Uw =
Ag + Af
Ag = 1,23 m Ug = 1,1 W/mK
Af = 0,59 m Uf = 1,3 W/mK
1480
lg = 4,46 m g = 0,06 W/m K
1,23 1,1 + 0,59 1,3 + 4,46 0,06
Uw =
1,23 + 0,59
Uw = 1,3 W/mK
1230
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
THERMAL TRANSMITTANCE
Evaluation of UW:
Calculation method EN ISO 10077-2
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
THERMAL TRANSMITTANCE
Evaluation of UW:
Test method EN ISO 12567-1.
www.latea.lv
WINDOWS AND DOORS CLASSIFICATION
THERMAL TRANSMITTANCE, INTERPRETATION OF RESULTS
DOORS
www.latea.lv
SYSTEM PASS FOR WINDOWS AND DOORS, SAMPLE
EN 14351-1
OPERATING FORCES 1 1 1 1 1
MECHANICAL STRENGTH 4 4 4 4 4
www.latea.lv
THEORY vs REALITY
www.latea.lv
THANK YOU FOR ATTENTION!
QUESTIONS, COMMENTS?