Você está na página 1de 2

INPUT DATA:

1) Materials Data
fc = 35 Mpa 0.75
3
wc = 2400 kg/m _ 1
Ec = 29910.2016 MPa
fyv = 420 MPa
Es = 200000 MPa
2) Concrete Dimensions
b = 200 mm short side of the column
t = 300 mm long side of the column
St = 500 mm
C = 100 mm
d = 400 mm

3) Column Case
Column Case : a
boUSER = NA mm (User Defined Punching Perimeter; Only for columns not matching any of t
_ 100 mm -
_ 100 mm -

4) Punching Loads
Column ID : Column No. :

Pu = 500 kN (Ultimate Column Punching Load)


Mu1 = 50 kN.m (Unbalanced Moment Between a Slab and a Column about the Column's W
Mu2 = 65 kN.m (Unbalanced Moment Between a Slab and a Column about the Column's St
wsu = 5 kN/m2 (For Floors Ultimate Uniform Load Over The Slab)
(For Foundation Ultimate Uniform Stress Beneath Foundation without Dire
Interior column Edge column 1
po,int = 2600 mm po,int = 1800 mm
x1 = 700 mm x1 = 600 mm
x2 = 600 mm x2 = 600 mm
1,f = 0.618 1,f = 0.600
1,v = 0.382 1,v = 0.400
2,f = 0.581 2,f = 0.600
2,v = 0.419 2,v = 0.400
c1 = 350 c1 = 300
' '
c1 = 350 c1 =
c2 = 300 c2 = 200
' '
c2 = 300 c2 =
J1/c1 = 237333333.3 J1/c1 = 178666666.7
J1/c1' = J1/c1' =
J2/c2 = 254666666.7 J2/c2 = 176000000
J2/c2' = J2/c2' =

section properties for punching


punching
= 2600
perimeter
area
resisting =
punching 1040000

ratio of long
side of the =
column to
short side of
the column 1.5
c = 40

properties for section resisting Mu1

B = 700 mm Length of the side parallel to mu2


D = 600 mm Length of the side parallel to mu1
3
J1/c1 = 237333333.3 mm

properties for section resisting Mu2

B = 600 mm Length of the side parallel to mu1


D = 700 mm Length of the side parallel to mu2