Multimetro G2 - Manual

Você também pode gostar

Você está na página 1de 4
G2 PHOENIX o r=) on — = a 4 ot — = S o oo = [—} qaCcitia won Fax (505) 605.6322 Infoueltestcom Introduction “The G2 Phoenix Series isa hand-hee battery powered digital multimeter ith clamp-on current measuring capably back ight and work srealight Features include “3-4/4 digit count 4000 count LCD display ‘Auto-anging measurement with manual ranging capability MINIMAX Peak Hol all ranges except Pequency) Frequency/OutyCycle/Data Hold ‘Auto power eff Dus splay Buin tert lead storage Easyue Sac splay & Worlght (L379 &OL388) Detachable current robe with optional curent hook a¢apter fortight spaces (1479 01388) Termperatre(DL379 & D389) Magnetic mount (0379 & L388) TRMS Measurement (L389 ony) Safety Notes Before using this mee tea alse oman crflly is pose phil hazards the se The wore "CAUTI + Donat attempt to measure any voltage that exceeds the ‘category bated ating ofthis meter += Donat stempt tous this meter ether the meter othe test leads have been damaged Tur instrument infor repair a qualified repair felty, + Tnsure meterleads are ful seated by making 2 quick ‘continuity check of the leads prior to making valage + Keep your fingers away trom the test leads metal probe contacts when making measurements Always grip the leads behind the fnger guards molded inte the probes + Donat open the meter to replace bateres while the probes are connected A WARNING! Exceeding the specie limits ofthis meter is dangerous and can ‘expose the User to serious or possibly otal injuy. + tages above 60 vs 0¢ 025 vets AC my constitute seiourshockhanad + Ays tuff owes ta ct erase under tet before cating unvlcering or reting the cert path= Even sal eros of caret canbe eangerous + Aays dacennet the eet end Before connecting the emenon tet ara ck «nthe event ect sock ALWAYS ring the vin tothe csvergency oon orev regards ofthe vat Sppucn covery occa shoccan cause an estble Rear yt tha ay need esi tention « Wanyef the ellen ndheatons cc euing testing tn ff thepower source tothe cre nder tet Hise + Ske | Bree heat + Slot bring ater | Scolntion or eling components A WARNING! Higher voltages and uments require greater arenes of physica! safety harrds Before connecting the ts leads turn of he power tothe cicut under est: 1et the meter tothe desired Tancion and rangerconmectthe et leads tothe meters. then connect the ‘iret under test Reapply power fan eroneous readings ‘observed aiconnect power immediately andrecheckaletngs Thismeter is designed for rade professional who are familae vith the hazard of ther trade, Observe all recommended safety procedures that include prope lock-out tization and the use of Personal protective equipment including safety glaies, loves, and flame resstant clothing, 8 ane or Controls and Indicators 1. lamp: Measure nective AC current.Opens to 125"(22-mm. 2. Wire Separation Tab/NCV sensor: Used tisolate an Inivieual wire from a bunele for testing, NCV sensor helps detect live voltage, Conductor Alignment Marks Used toad inthe visual alignment ofa conductor when measuring inductive amperage, {Greatest accuracy is achieved when the conductor inside the lamp is centered atthe intersection of hese mars 4, Test Lead Holder: Used forhanl-fee use of one ofthe test probes 5. Hand Guar ale A WARNING! ‘Always Keep your hands and fingers behind the hand guard When measuring current on exposed conductors. Contact may Fesult hn serious nury Used as a pint of ference forthe operators 6. Clamp Lever Opens and closes current clamp jaw, NOTE: The clamp uses ahigh tension spring to close the Jaw. Do not allow fingers or ebjects to become pinched in the base asjaw doses [NCV Button: Activates non-contact voltage function 1. Range Button: Used to select range fr upper and lover aphy ‘9, HOLD/Backlight Buton:Frezes liplay or activates eiplay backlight and work ate light (Baclight and work area ight only available on 0379/0385) 10.MIN/MAX Button: Activates MIN/MAX capture function, ‘cles through minimum value, maximum value, Press longer than two seconds to retun ove reading Rotary Function Switeh:Tuns meter on ands used te select ‘the function desired 2. Upper Display Used to display curent when used with UE ‘lamp or hook adapter Displays output rom other accessories When connected te the UEl meter 5. Lower Display: Used to dlspay input to test ead jacks Includes ACIDC Volts, Frequency, Resistance Diode, CCapactance and AC/DC microamps (i) 14.Select Button: Used to choose messurement mde from selections with malta options such a5 AC of DC vols, AC or OC HA, Resistance, Diode, capactance ar Contnulty, TemperatureinFor’C 15. Temperature Input Jack Input ack for thermocouple probe (0.379/DL389 on 16. Temperature Switch: Mave the Switch oven to measure temperature NOTE: Test leads must be removed from input Jacks prior to operating the temperature function 11. HarDuty Button: Used to scroll through Frequency or Duty (yee when inthe ACVoltage measurement mode. 18.Commen Terminal: The lack test ead ie plugged int this terminal supply the ground or lo” reference for all measurements 19. Category Max indicator: Indicates maximum voltage forthe rated wotking category. A WARNING! DoNotexceed 1000 volts DCor AC- RMS a either the ‘common or multifunction imput ports as measured from earth ground. 20. Multifunction input Jack: Use for measuingACIDC Vos, Frequency oF Duty Cycle, Resistance Diode Continuity ane Capactance Displays and Indicators pisse ous Diss = ‘AC indicator = DCindator = Indicates anegave value (DC Negative VaR) Wax Maximum value displayed in Minimum vale displayed ‘A (top dlplay) Display is in Arps trom UEi Camp or Hook adapter, "ADP (top display Displays vale from adapter Tow batty symbol Hold function activated =e Diode function i Contnity function w/a Copacianee(nanofrads or mitered) ry Mcroamps (1s 0900001 Ane) HE Frequengymeasureent % Daty Gye measurement mv Miva (rs 0.001 Vo ‘APO ‘Ao power off mode ate ar Ao range funcion acne OL Displayed tie input value exceeds soled ange Operating Instructions sto power ft Aer peng ofthe meter wiltum bckon you perform one of thetllowing Change te range move he poston ft sleet Shy otherbitionipressee. MOTE APO dsobeduhe h aN move Backlight / work arealight(0L379 /DL389 only) Press the" HOLD" button longer than two seconds to activate the backlight work area ight Te lights automaticaly tn off after minutes extend bate ie, NOTE: Aer activating wokght press bil to activate hold ‘Auto / Manual Range Inauto ange the meter wil elect the best range forthe measured Value, and "AT"isdslayed. Press the "RANGE" button to cycle ‘through avalableranges "AT" willnet be onthe display when locked Inaspecic ange. Press and hold "RANGE" button to return to aute range MIN/MAX mode When using the MIN/MAX capture mode for Ampsit is recommended that you fist elect the range ofthe expected maximum value Ifthe tenot done twillock inte lowest range posible fr the nal measurement the maximum value exceeds th range the mete ill ‘capture “0. asthe maximum value Manual ranging willabo provide a faster response tothe input Data Hold Press the EME button to activate This wil reeze the reading and range inthe esplay fr your review ‘Measuring AC Amps + Select any function to power ‘the upper display + Press "MAX/MIN to activate ‘Max capture, Min capture, of normal display. (NOTE: Max captures useful for motrin rush curent. Pres "RANGE" to select rg rirto MAN. Press “SELECT” to change the reading fom AC to DC ‘Measuring Frequency oF Duty Cycle Meter must be in AC Volts o Ac mode fist then press "Hx/Duty"to change function to Frequency or Duty Cyl, NOTE Frequency great te wl dspoy “0.000 Be" Measuring Resistance and Capacitance 2e-a a a NOTE: Capacitance - Leave the meter connected the capac for 10 seconds ‘or more forthe reading to stabilize ‘Measuring Continuity and Diode ress "SELECT" to move rom Contity z ‘mode to Diode mode " Nore: Diode -"OL"inreverse mode and approximate forward veltage drop when connected in forward mode. = ‘Continuity - Sounds the tone approximately 50.2 or less. ‘Measuring Temperature (DL379/D1388 only) Slide temperature siteh ov prior to connecting probe Press “SELECT” to change scale from F to “Cdl. | A vane ) Diconnect test leads rom any velage source andthe meter Deore plugging in thermocouple. Temperature Adjustment Remove battery cove. Place temperature probe in a known standard, (Sted crushed icon distilled water can be used for a) Adjust potentiometer with 2 fine tip standard screwdriver to match the dspay to 32°F, (NOTE: The adjustment forthe potentiometer is acessible through the lower right access prt under the Battery cover Measuring NCV ‘Non-Contact Voltage Press and hold the "NEW" buton at any range and move the meter near this voltage source NOTE IThe backght/ worklight ‘son, the worklight il tum off

Você também pode gostar