Você está na página 1de 32

MC-UNO08 Rev.

1
MC-CONEN Rev.13

A Conical Connection Implant

MAKE IT SIMPLE
P.4-5

P.6-7

P.8-9

P.10-11

P.12-14

P.15-16

P.17-19

P.20-21

P.22-23

P.24-25

P.26-27

P.28

P.29

MIS Warranty:

MIS exercises great care and effort in maintaining the superior quality of its
products. All MIS products are guaranteed to be free from defects in material
and workmanship. However, should a customer find fault with any MIS product
after using it according to the directions, the defective product will be replaced.
Warning: Products should be used by licensed dentists only.
Table of contents.

Introduction

Advantages

Surface Quality

Narrow Implants (3.30mm)

Standard Implants (3.75mm, 4.20mm)

Wide Implants (5mm)

C1 Surgical Kit

Drilling Procedures

Dual Stability Mechanism

Drill Stopper Kits

Insertion Tools

Package Contents

Packaging
4.

The C1 implant system is an advanced implant design

that offers a unique combination of surgical and restorative

benefits, including a differential thread design to ensure

superior initial stability in different clinical situations, platform

switching and a conical connection with an anti-rotation

index. Each C1 implant comes with a single-use final drill

to ensure a safer and more accurate drilling procedure.

MIS Corporation. All rights reserved.


6.

Advantages. Yellow
indicates a
Narrow platform

Advantages.

All C1 implants, superstructures


Green
and tools are color-coded for indicates a
simple and immediate identification Wide platform
of the platform size.

Purple
indicates a
Standard platform

C1 Conical connection implants


Prosthetic options
A broad range of MIS conical connection prosthetic components presents
uncompromising accuracy; a consistent concave emergence profile for
excellent soft tissue results; golden shade to support high esthetic results;
color coding for simple and immediate platform identification and a positioning
groove ensures definite fit over the implant.

Platform switching
The C1 platform switching keeps the implant-abutment connection away
from the bone; minimizing bone resorption. Platform switching additionally
allows more vital growth of the soft tissue.

Conical connection
Featuring a 6-degree conical connection that ensures a secure fit between
abutment and implant, the C1 minimizes micro-movements reducing bone
loss at the crestal level. It has is a six-position cone index within the conical
connection to help orient the implant during insertion as well as placing the
abutment into the proper position.

Micro-rings
At the neck of the C1, micro-rings significantly increase the BIC (Bone to
Implant Contact), avoiding bone resorption at the crestal zone.

Dual thread
The C1 dual thread design increases the BIC (Bone to Implant Contact) over
the entire body of the implant. The dual thread doubles the implant insertion
rate (1.50mm), facilitating a simpler and faster implant placement.

Conical shape
With its conical, root-shaped geometry and a unique thread design, C1
ensures a superior primary stability and offers the ultimate choice for a wide
range of clinical cases and loading protocols Its root-shaped design makes
C1 ideal for narrow spaces, restricted by adjacent teeth or implants.

Two spiral channels and domed apex


The C1 features a domed apex, providing a high tolerance and safe procedure
during insertion. Two cutting blades at the implant apex establish the self-
tapping properties of the C1; supporting a simpler, safer and faster procedure.
8.

Advantages.

Surface Quality.

C1 implants are sand-blasted


and acid-etched. These surface
treatments increase the implant
surface area by creating both
micro and nano-structures and
eliminating various surface
contaminants.
The surface of MIS implants
was found superior in its purity
compared to other implant systems
by two independent researches,
as published in the POSEIDO
Journal and in EDI Journal.
2015/1

SURFACE ANALYSIS OF STERILE-PACKAGED IMPLANTS


Dr. Dirk Duddeck and Dr. Jrg Neugebauer, PhD

For the third time in a row, the Quality and Research (Q&R) Committee of BDIZ EDI is examining sterilepackaged implants under
the scanning electron microscope for the more than 5,500 members of the association. In cooperation with the University Hospital
of Cologne, extensive qualitative and quantitative elemental analyses are performed on each of the implants studied. In 2009/2008,
the surfaces of 23 implants were analyzed, a number that had grown to 54 different implants from manufacturers in nine countries
by 2012/2011. Here, isolated implants showed residue from the manufacturing and/or packaging process, pecularities in the
external threading or residual filings inside the implant.

65 dental implants from different leading manufacturers underwent topographical and chemical composition analysis. The protocol
included the use of a Scanning Electron Microscope (SEM), which enabled the topical evaluation of each implant surface. The
high sensitivity backscattered electron detector generates images in compositional and topographical modes to a magnification
of up to X5,000 for this study. The BSE detector also allows researchers to draw conclusions about the chemical nature and
allocation of remnants or contaminants on the sample material. Qualitative and quantitative analyses of implant surfaces were
done using Energy Dispersive X-ray Spectroscopy (EDX). This element identification software even allows the identification of
elements deep within the sample. Testing on MIS implants revealed percentages of Titanium, Oxygen, Aluminum and Vanadium.

Conclusions reached in the study state:


"The C1 implant and the Seven implant (both MIS) stood out positively in the current study. Whereas during the 2012/2011 study,
the Seven implant still exhibited blasting material on up to seven per cent of the surface, the current study did not even find
isolated spots with residue on the two MIS implant types of grade 23 titanium (Ti 6Al4-V ELI)".

Residue-free surface, MIS C1 implant (x 1000). MIS C1 implant surface with micro-nano-structure (x 2,500). MIS C1 implant side-view of a thread (x 2,000).

The study is available for download from the MIS Website: Surface
Analysis of Sterile-Packaged Implants: EDI Journal, Issue 2015/1:
http://www.mis-implants.com/Scientific/Articles.aspx
10.

Screw type implant range


Narrow Platform

Length 10mm 11.50mm 13mm 16mm

Type C1-10330 C1-11330 C1-13330 C1-16330

3.30
mm

Surgical Tools

CT-NLI10 CT-NSI10 CT-NLR10 CT-NSR10


Long insertion tool, Short insertion tool, Long ratchet insertion Short ratchet insertion
conical conn., NP conical conn., NP tool, conical conn., NP tool, conical conn., NP

Implant cover screw and healing caps

Gingival Gingival Gingival


heights: 3.3mm heights: 4mm heights: 4.8mm
CN-H0333 CN-HS340 CN-HA248
CN-H0433 CN-HS440 2, 3, 4, 5, 6, 8mm
CN-HA348
3, 4, 5, 6, 8mm 3, 4, 5, 6, 8mm CN-HA448
CN-H0533 CN-HS540
CN-H0633 CN-HS640 CN-HA548
CC1-00330 CN-H0833 CN-HS840 CN-HA648
CN-HA848
3.30mm
Catalog No. Dimensions Narrow Platform

3.30mm
C1-10330 Length 10mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched

3.30mm
C1-11330 Length 11.5mm

C1-13330 3.30mm
Length 13mm

2.75

C1-16330 3.30mm
Length 16mm 3.2
3.30

Single-use final drill


A specially designed final drill for 10mm,
11.50mm, 13mm and 16mm implants is
supplied with every implant, allowing a short,
2.4 2.50
sterile and safe drilling procedure. This final
drill should not be used in type 4 bone.
* The implant package includes: a cover screw,
temporary cylinder and a final drill

3.30mm Implant Procedure

200-
1200- 900- 400
Drilling Speed (RPM) 1500 1200 15-25
3
Diameter 1.90 2.40 2.40 3.60 3.30

Final drill
For bone
type 1,2&3

Do not use the final drill for bone type 4

The drilling sequence is illustrated using


a 13mm implant.

Procedure recommended by MIS cannot


replace the judgment and professional
experience of the surgeon.
12.

Screw type implant range


Standard Platform

Length 8mm 10mm 11.50mm 13mm 16mm

Type C1-08375 C1-10375 C1-11375 C1-13375 C1-16375

3.75
mm

C1-08420 C1-10420 C1-11420 C1-13420 C1-16420

4.20
mm

Surgical Tools

CT-SLI10 CT-SSI10 CT-SLR10 CT-SSR10


Long insertion tool, Short insertion tool, Long ratchet insertion Short ratchet insertion
conical conn., SP conical conn., SP tool, conical conn., SP tool, conical conn., SP

Implant cover screw and healing caps

Gingival Gingival Gingival


heights: 3.9mm heights: 4.8mm heights: 5.8mm
CS-H0339 CS-HS248 VS-HS358
3, 4, 5, 6, 8mm CS-H0439 2, 3, 4, 5, 6, 8mm CS-HS348 3, 4, 5, 6, 8mm VS-HS458
CS-H0539 CS-HS448 VS-HS558
CS-H0639 CS-HS548 VS-HS658
CC1-00375 CS-H0839 CS-HS648 VS-HS858
CS-HS848
3.75mm
Catalog No. Dimensions Standard Platform

3.75mm
C1-08375 Length 8mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched

3.75mm
C1-10375 Length 10mm

C1-11375 3.75mm
Length 11.50mm

3.15

C1-13375 3.75mm
Length 13mm 3.60
3.75

Single-use final drill


C1-16375 3.75mm A specially designed final drill for 8mm,
Length 16mm 10mm, 11.50mm, 13mm and 16mm implants
is supplied with every implant, allowing a
3 3.10
short, sterile and safe drilling procedure. This
final drill should not be used in type 4 bone.
* The implant package includes: a cover screw,
temporary cylinder and a final drill

3.75mm Implant Procedure

200-
1200- 900- 500- 400
Drilling Speed (RPM) 1500 1200 700 15-25
3
Diameter 1.90 2.40 2.40 3 3 3.60 3.75

Final drill
For bone
type 1,2&3

Do not use the final drill for bone type 4

The drilling sequence is illustrated using


a 13mm implant.

Procedure recommended by MIS cannot


replace the judgment and professional
experience of the surgeon.
14.

4.20mm
Catalog No. Dimensions Standard Platform

C1-08420 4.20mm
Length 8mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched

C1-10420 4.20mm
Length 10mm

C1-11420 4.20mm
Length 11.50mm

3.15

C1-13420 4.20mm 4
Length 13mm
4.20

4.20mm Single-use final drill


C1-16420 Length 16mm A specially designed final drill for 8mm,
10mm, 11.50mm, 13mm and 16mm implants
is supplied with every implant, allowing a
3.50 3.60 short, sterile and safe drilling procedure. This
final drill should not be used in type 4 bone.
* The implant package includes: a cover screw,
temporary cylinder and a final drill

4.20mm Implant Procedure

200-
1200- 900- 500- 400- 400
Drilling Speed (RPM) 1500 1200 700 700 15-25
3.50
Diameter 1.90 2.40 2.40 3 3.50 3.50 4 4.20

Final drill
For bone
type 1,2&3

Do not use the final drill for bone type 4

The drilling sequence is illustrated using


a 13mm implant.

Procedure recommended by MIS cannot


replace the judgment and professional
experience of the surgeon.
Screw type implant range
Wide Platform

Length 8mm 10mm 11.50mm 13mm 16mm

Type C1-08500 C1-10500 C1-11500 C1-13500 C1-16500

5
mm

Surgical Tools

CT-WLI10 CT-WSI10 CT-WLR10 CT-WSR10


Long insertion tool, Short insertion tool, Long ratchet insertion Short ratchet insertion
conical conn., WP conical conn., WP tool, conical conn., WP tool, conical conn., WP

Implant cover screw and healing caps

Gingival Gingival
heights: 5.5mm heights: 6.3mm
CW-HS355 CW-HA263
3, 4, 5, 6mm
CW-HS455 2, 3, 5mm
CW-HA363
CW-HS555 CW-HA563
CW-HS655
CC1-00500
16.

5mm
Catalog No. Dimensions Wide Platform

5mm
C1-08500 Length 8mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched

5mm
C1-10500 Length 10mm

C1-11500 5mm
Length 11.50mm

4.90
C1-13500 5mm
Length 13mm
5

Single-use final drill


C1-16500 5mm A specially designed final drill for 8mm,
Length 16mm 10mm, 11.50mm, 13mm and 16mm implants
is supplied with every implant, allowing a
4.10 4.50
short, sterile and safe drilling procedure. This
final drill should not be used in type 4 bone.
* The implant package includes: a cover screw,
temporary cylinder and a final drill

5mm Implant Procedure

200-
1200- 900- 500- 400- 400- 400
Drilling Speed (RPM) 1500 1200 700 700 600 15-25
4.10
Diameter 1.90 2.40 2.40 3 3.50 4 4 4.90 5

Final drill
For bone
type 1,2&3

Do not use the final drill for bone type 4

The drilling sequence is illustrated using


a 13mm implant.

Procedure recommended by MIS cannot


replace the judgment and professional
experience of the surgeon.
C1 Surgical Kit

The C1 surgical kit comprises a complete range of drills and tools required for C1 implant
placement procedures. It features a convenient ergonomic layout that follows the surgical drilling
sequence, and includes a set of length-based pilot drills for a smoother, more accurate procedure.
Kit components are color-coded for immediate identification of diameters for both implants and
restorative platforms.
18.

25
10
24
27

14
26

36
13

32
C1 Surgical Kit 8

35 12
MK-0044 With external
irrigation drills

5
22
4

23 3

20
1
21

MARKING DRILLS PILOT DRILLS STEP DRILLS BODY TRY-INS

1 3 8 12
MT-TDN19 CT-P2408 CT-TDC30 CT-BTC24
Marking drill, 1.90mm Pilot drill with built-in stopper Step drill, 3/2.4mm, external irrigation Body try-in, 2.40mm
external irrigation 2.4/2.0mm, height 8mm

2 4 9 13
MT-SMD10 CT-P2410 CT-TDC35 CT-BTC30
Spade marking drill Pilot drill with built-in stopper Body try-in, 3mm
Step drill, 3.5/3mm, external irrigation
2.4/2.0mm, height 10mm

5 10
14
CT-P2411 CT-TDC40 CT-BTC35
Pilot drill with built-in stopper Step drill, 4/3.5mm, external irrigation Body try-in, 3.50mm
2.4/2.0mm, height 11.5mm

11
6 15
CT-P2413 CT-TDC45 CT-BTC40
Pilot drill with built-in stopper, Step drill, 4.5/4mm, external irrigation Body try-in, 4mm
2.4/2.0mm, height 13mm

7 16
CT-P2416
Pilot drill, 2.4/2.0mm, CT-BTC45
height 16mm Body try-in, 4.5mm
29
10
28
31
SURGICAL TOOLS

15 32
11
30 MT-PP240
Parallel pin, 2.40/3mm

33
16
MT-DE001
Drill extender
17
34

MT-RT070
Torque Ratchet for implant placement

18
35
MT-RE160
Int. connection abutment extractor, NP
19 34

36

5 MT-RE172
Int. connection abutment extractor, SP

6
33 37

MT-RDL30
7 Long hex. drive for 0.05 inch

2 38
37 38
MT-RDS30
Short hex. drive for 0.05 inch

COUNTERSINKS INSERTION TOOLS

17 20 24 28

MT-CSN33 CT-NSR10 CT-SSR10 CT-WSR10


Short ratchet insertion tool, Short ratchet insertion tool, Short ratchet insertion
Countersink, NP tool,conical conn., WP
conical conn., NP conical conn., SP

18
21 25 29
MT-GDN33
Countersink, SP CT-NLR10 CT-SLR10 CT-WLR10
Long ratchet insertion tool, Long ratchet insertion tool, Long ratchet insertion tool,
conical conn., NP conical conn., SP conical conn., WP

19
22 26 30
MT-GDN50 CT-NSI10 CT-SSI10 CT-WSI10
Countersink, WP Short insertion tool, Short insertion tool, Short insertion tool,
conical conn., NP conical conn., SP conical conn., WP

27 31
23
CT-NLI10 CT-SLI10 CT-WLI10
Long insertion tool, Long insertion tool, Long insertion tool,
conical conn., NP conical conn., SP conical conn., WP
20.

Initial surgical steps are common


Drilling for all implant diameters. Additional
Procedures. steps are required as the implant
diameter increases.

3.75
DRILL 1.90mm
A R KING
M
E/ .40mm
SPAD
D R ILL 2
T
PILO
2.40mm
T RY-IN
DY
BO
ILL 3mm
T DR

SP
IS

AD
TW

E/
N 3mm
TRY-I

4
MA
DY

PIL
O

BO
B

RK
OT
ILL
AL DR

.20
DY
FIN

ING
DR
TW

TR

ILL
TW

DRI
B

Y-IN
IST

2.4
IST
OD

LL
DR

2.4
DR
YT

0mm
LL 3

1.90mm
FIN

ILL
R

0mm
Y-IN

mm
AL

3.50m
DRILL

3.5mm

C1 IMPLANT
SPADE / MAR

BODY TRY
PILOT DR

FI NAL

L
RI
L
DR

F I N AL D
-IN
ILL
KING

m
ILL

4
3.3

I N
2.40

2.40

B O DY TRY - m
DRI

4m
mm
mm

L
RIL
LL
0

TWIST D mm
.50
1.9

3
ILL
0m

TWIST DR
mm
m

R I LL3
TWIST D m
0m
2.4
Y-IN
BODY TR 0m
2.4 mm
R ILL .90
PILO T D 1
LL
G DRI
KIN
SPADE / MAR
5

Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
ST
NA

AN
RR

DA

WI
OW

DE
RD
1.90 2.40 2.40 3 3 3.50 3.50 4 4

Procedure Tools
Description.

Fin
al
Bo dr
dy ill
Tw try
ist -in
Bo dr 4
ill m
dy 4m m
Tw try m
ist -in , ex
Bo dr 3 ter
dy ill .50 na
3.5 l ir
Tw try 0m m rig
ist -in m m ati
Bo d rill 3m , ex on
dy 3m m ter
Pi try m na
lot -in ,e l ir
dr xte rig
i 2 r ati
Sp ll .40 n al on
ad 2.4 m irr
e 0m m iga
/m m tio
ar n
kin
g
dr
ill
1
.90
m
m
13.
22.
The Dual Stability Mechanism surgery. This differential drilling
method enables moderate
The C1 offers a Dual Stability
compression of the bone at
Mechanism ( DSM ) that
the top 2/3 of the implant body
combines the benefits of
in order to gain mechanical
high primary stability with an
stability, while preventing such
accelerated osseointegration
compression at the apical 1/3.
process, thus minimizing stability
loss during the first weeks after

AL
HANIC STABIL
EC ITY
M
Thanks
Thanks to a to a
unique
unique drilling methodology,
drilling methodology, the implant's
the implant's geometric design
geometric design enables a moderate
enables a moderate compression
compression
of the bone atofthethetop
bone 2/3atofthe
itstop 2/3
body.
ofThis
the body. This compression,
congestion, enabledenabled by a
by a distinctive
distinctive conical
conical shaped
shaped final
nal drill,
drill,
provides
provides an immediate and prolonged
an immediate and
prolonged
mechanical primarymechanical
stability.
primary stability.
The 'compartments' created between
the threads at the apical 1/3 are filled
with blood and bone particles, enabling
rapid bone growth.

ICAL STABI
LOG LIT
IO Y
B
An enhanced
An enhanced secondary
secondary biological stability
biological stability is achieved by
is achieved by integration of the
integration of the implant's geometry,
implant's geometry,
morphology morphology
and a differential and
drilling
a differential drilling approach.
approach. The compartments formed The
compartments
between formed
the implant's threadsbetween the
at the bottom
implant's
1/3 threads
of the cavity at thean
generate bottom 1/3 of
ideal habitat
thesustainable
for cavity, generate
bonean ideal leading
growth habitat
foraccelerated
to sustainable bone growth
osseointegration.
leading to an accelerated
osseointegration.
24.

Following the use of MIS length-


based pilot drills, the C1 Standard
Drill Stoppers Kit Platform Stoppers Kit ensures drilling
to the exact desired depth. The kit
Standard Platform. includes the most commonly used
lengths: 8, 10, 11.5 and 13mm.
MK-BC101

Stoppers
Four sleeves for each diameter
in 8, 10, 11.5 and 13mm lengths,
color-coded according to drills.

Box
The tray can be removed
from the box for ease of use.

Scale

Teflon IN Insert

Teflon OUT Insert

Simple. Kit Contents 3 stoppers 3.50 stoppers


(for 3.75mm implants) (for 4.20mm implants)
Quick, easy assembly.
Easy.
Color-coding for quick identification of
the sleeve diameter.

Safe.
Safe drilling to desired depth.

Fast.
Clearly arranged depth sleeves for quick and easy identification
of 8-13mm lengths and 3, 3.5mm diameter stoppers.
Following the use of MIS length-
based pilot drills, the C1 Drill Stoppers
Kit enables safe and easy drilling to Drill Stoppers Kit
the exact desired depth. MIS offers Depth Based.
4 different kits in lengths of: 8, 10,
11.5 and 13mm.

Stoppers
Five sleeves 3.0, 3.5, 4, 4.5 and
5mm diameters, color-coded
according to drills.

Box
The tray can be
removed from the box
for ease of use.

13mm
11.5mm
10mm
8mm Desired
drilling depth

Scale

Teflon IN Insert

Teflon OUT Insert

Simple. Kit Contents For 8mm implants For 10mm implants


MK-CDS08 MK-CDS10
Quick, easy assembly.
Easy.
Color coding for a quick identification
of sleeve diameter.
For 11.5mm implants For 13mm implants
Safe. MK-CDS11 MK-CDS13
Safe drilling to desired depth.

Fast.
Clearly arranged depth sleeves for quick and easy
identification of 3mm to 5mm diameter drills.
26.
22.
20.

Insertion Tools. C1 implant placement tools are specially


designed to facilitate quick and reliable
Standard platform tools shown
implant procedures.

Long ratchet insertion tool, SP

Short ratchet insertion tool, SP


Long insertion tool, SP

Short insertion tool, SP

Long drive for 0.05 inch hex.

Short drive for 0.05 inch hex.

CT-SSR10
CT-SLR10
CT-SSI10 MT-RDL30

CT-SLI10 MT-RDS30
20.

MIS offers a line of specially


engineered insertion tools suitable
for use either manually or with
the unique insertion tool system,
which allows secure implant
placement without the use of a
mount, effectively reducing the
number of tools required in the
armamentarium.
2

3
1

Insertion options: Please note: In order to assure their efficient


operation, tools should be fully inserted into
1 the implants. A complete insertion of the tool
optimizes the transfer of force during implant
Insertion tool in manual use
placement and enables simple release of
the tool from the hex. whenever necessary.
2
Insertion tool for motor Tool will not hold implant unless it is
completely inserted into the hex.
3
Insertion tool in ratchet wrench
28.

Each C1 implant comes with


Package Contents. sterilized components for multiple
clinical scenarios.

Following the "Make It Simple"


philosophy, MIS is proud to be the
first to present a comprehensive tool
set which includes: a single-use final
drill, a cover screw and a temporary
cylinder with every C1 implant, meeting
all your clinical needs.
Temporary Cylinder

Outer Tube
Inner Tube
Cover Screw

Final Drill
Implant
12.

Implant diameter & platform indication


The outer tube is color-coded indicating the
implant platform. The numeric indication
specifies the implant diameter and length.

Prosthetic platform indication

Packaging. Prosthetic components are


marked by specific colors,
representing platform sizes.

Providing a simple, immediate


identification of implant type, length
and diameter, the C1 package
is well designed for ease of use
during surgery.

A double packing system ensures sterilization and


safety. Packages are designed for ease of use during
surgery and for use with surgical gloves.

Implant identification markings


Quick identification of implant size and length.
Sticker on the box lid, specifies implant diameter,
length and platform size.

Easy pull tab


The convenient pull tab facilitates quick
and easy opening during surgery.
All rights reserved. No part of this publication
may be reproduced, transcribed, stored in
an electronic retrieval system, translated into
any language or computer language, or be
transmitted in any form whatsoever, without
the prior written consent of the publisher.
MC-UNO08 Rev.1
MC-CONEN Rev.13
The MIS Quality System complies with international
quality standards: ISO 13485:2003 - Quality

Management System for Medical Devices, ISO
9001: 2008 - Quality Management System and
CE Directive for Medical Devices 93/42/EEC. MIS
products are cleared for marketing in the USA
MIS Implants Technologies Ltd.
www.mis-implants.com
MIS Implants Technologies Ltd
0483
and CE approved.

www.mis-implants.com
Authorized European Representative:
MIS Germany, Paulinenstrae 12a, 32427 Minden, GERMANY

MIS Corporation. All rights reserved.

MIS Corporation. All Rights Reserved.

Você também pode gostar