MIS Warranty:
MIS exercises great care and effort in maintaining the superior quality of its
products. All MIS products are guaranteed to be free from defects in material
and workmanship. However, should a customer find fault with any MIS product
after using it according to the directions, the defective product will be replaced.
Warning: Products should be used by licensed dentists only.
Table of contents.
Introduction
Advantages
Surface Quality
C1 Surgical Kit
Drilling Procedures
Insertion Tools
Package Contents
Packaging
4.
Advantages. Yellow
indicates a
Narrow platform
Advantages.
Purple
indicates a
Standard platform
Platform switching
The C1 platform switching keeps the implant-abutment connection away
from the bone; minimizing bone resorption. Platform switching additionally
allows more vital growth of the soft tissue.
Conical connection
Featuring a 6-degree conical connection that ensures a secure fit between
abutment and implant, the C1 minimizes micro-movements reducing bone
loss at the crestal level. It has is a six-position cone index within the conical
connection to help orient the implant during insertion as well as placing the
abutment into the proper position.
Micro-rings
At the neck of the C1, micro-rings significantly increase the BIC (Bone to
Implant Contact), avoiding bone resorption at the crestal zone.
Dual thread
The C1 dual thread design increases the BIC (Bone to Implant Contact) over
the entire body of the implant. The dual thread doubles the implant insertion
rate (1.50mm), facilitating a simpler and faster implant placement.
Conical shape
With its conical, root-shaped geometry and a unique thread design, C1
ensures a superior primary stability and offers the ultimate choice for a wide
range of clinical cases and loading protocols Its root-shaped design makes
C1 ideal for narrow spaces, restricted by adjacent teeth or implants.
Advantages.
Surface Quality.
For the third time in a row, the Quality and Research (Q&R) Committee of BDIZ EDI is examining sterilepackaged implants under
the scanning electron microscope for the more than 5,500 members of the association. In cooperation with the University Hospital
of Cologne, extensive qualitative and quantitative elemental analyses are performed on each of the implants studied. In 2009/2008,
the surfaces of 23 implants were analyzed, a number that had grown to 54 different implants from manufacturers in nine countries
by 2012/2011. Here, isolated implants showed residue from the manufacturing and/or packaging process, pecularities in the
external threading or residual filings inside the implant.
65 dental implants from different leading manufacturers underwent topographical and chemical composition analysis. The protocol
included the use of a Scanning Electron Microscope (SEM), which enabled the topical evaluation of each implant surface. The
high sensitivity backscattered electron detector generates images in compositional and topographical modes to a magnification
of up to X5,000 for this study. The BSE detector also allows researchers to draw conclusions about the chemical nature and
allocation of remnants or contaminants on the sample material. Qualitative and quantitative analyses of implant surfaces were
done using Energy Dispersive X-ray Spectroscopy (EDX). This element identification software even allows the identification of
elements deep within the sample. Testing on MIS implants revealed percentages of Titanium, Oxygen, Aluminum and Vanadium.
Residue-free surface, MIS C1 implant (x 1000). MIS C1 implant surface with micro-nano-structure (x 2,500). MIS C1 implant side-view of a thread (x 2,000).
The study is available for download from the MIS Website: Surface
Analysis of Sterile-Packaged Implants: EDI Journal, Issue 2015/1:
http://www.mis-implants.com/Scientific/Articles.aspx
10.
3.30
mm
Surgical Tools
3.30mm
C1-10330 Length 10mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched
3.30mm
C1-11330 Length 11.5mm
C1-13330 3.30mm
Length 13mm
2.75
C1-16330 3.30mm
Length 16mm 3.2
3.30
200-
1200- 900- 400
Drilling Speed (RPM) 1500 1200 15-25
3
Diameter 1.90 2.40 2.40 3.60 3.30
Final drill
For bone
type 1,2&3
3.75
mm
4.20
mm
Surgical Tools
3.75mm
C1-08375 Length 8mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched
3.75mm
C1-10375 Length 10mm
C1-11375 3.75mm
Length 11.50mm
3.15
C1-13375 3.75mm
Length 13mm 3.60
3.75
200-
1200- 900- 500- 400
Drilling Speed (RPM) 1500 1200 700 15-25
3
Diameter 1.90 2.40 2.40 3 3 3.60 3.75
Final drill
For bone
type 1,2&3
4.20mm
Catalog No. Dimensions Standard Platform
C1-08420 4.20mm
Length 8mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched
C1-10420 4.20mm
Length 10mm
C1-11420 4.20mm
Length 11.50mm
3.15
C1-13420 4.20mm 4
Length 13mm
4.20
200-
1200- 900- 500- 400- 400
Drilling Speed (RPM) 1500 1200 700 700 15-25
3.50
Diameter 1.90 2.40 2.40 3 3.50 3.50 4 4.20
Final drill
For bone
type 1,2&3
5
mm
Surgical Tools
Gingival Gingival
heights: 5.5mm heights: 6.3mm
CW-HS355 CW-HA263
3, 4, 5, 6mm
CW-HS455 2, 3, 5mm
CW-HA363
CW-HS555 CW-HA563
CW-HS655
CC1-00500
16.
5mm
Catalog No. Dimensions Wide Platform
5mm
C1-08500 Length 8mm Titanium Alloy Ti 6Al 4V ELI
Sand-Blasted and Acid-Etched
5mm
C1-10500 Length 10mm
C1-11500 5mm
Length 11.50mm
4.90
C1-13500 5mm
Length 13mm
5
200-
1200- 900- 500- 400- 400- 400
Drilling Speed (RPM) 1500 1200 700 700 600 15-25
4.10
Diameter 1.90 2.40 2.40 3 3.50 4 4 4.90 5
Final drill
For bone
type 1,2&3
The C1 surgical kit comprises a complete range of drills and tools required for C1 implant
placement procedures. It features a convenient ergonomic layout that follows the surgical drilling
sequence, and includes a set of length-based pilot drills for a smoother, more accurate procedure.
Kit components are color-coded for immediate identification of diameters for both implants and
restorative platforms.
18.
25
10
24
27
14
26
36
13
32
C1 Surgical Kit 8
35 12
MK-0044 With external
irrigation drills
5
22
4
23 3
20
1
21
1 3 8 12
MT-TDN19 CT-P2408 CT-TDC30 CT-BTC24
Marking drill, 1.90mm Pilot drill with built-in stopper Step drill, 3/2.4mm, external irrigation Body try-in, 2.40mm
external irrigation 2.4/2.0mm, height 8mm
2 4 9 13
MT-SMD10 CT-P2410 CT-TDC35 CT-BTC30
Spade marking drill Pilot drill with built-in stopper Body try-in, 3mm
Step drill, 3.5/3mm, external irrigation
2.4/2.0mm, height 10mm
5 10
14
CT-P2411 CT-TDC40 CT-BTC35
Pilot drill with built-in stopper Step drill, 4/3.5mm, external irrigation Body try-in, 3.50mm
2.4/2.0mm, height 11.5mm
11
6 15
CT-P2413 CT-TDC45 CT-BTC40
Pilot drill with built-in stopper, Step drill, 4.5/4mm, external irrigation Body try-in, 4mm
2.4/2.0mm, height 13mm
7 16
CT-P2416
Pilot drill, 2.4/2.0mm, CT-BTC45
height 16mm Body try-in, 4.5mm
29
10
28
31
SURGICAL TOOLS
15 32
11
30 MT-PP240
Parallel pin, 2.40/3mm
33
16
MT-DE001
Drill extender
17
34
MT-RT070
Torque Ratchet for implant placement
18
35
MT-RE160
Int. connection abutment extractor, NP
19 34
36
5 MT-RE172
Int. connection abutment extractor, SP
6
33 37
MT-RDL30
7 Long hex. drive for 0.05 inch
2 38
37 38
MT-RDS30
Short hex. drive for 0.05 inch
17 20 24 28
18
21 25 29
MT-GDN33
Countersink, SP CT-NLR10 CT-SLR10 CT-WLR10
Long ratchet insertion tool, Long ratchet insertion tool, Long ratchet insertion tool,
conical conn., NP conical conn., SP conical conn., WP
19
22 26 30
MT-GDN50 CT-NSI10 CT-SSI10 CT-WSI10
Countersink, WP Short insertion tool, Short insertion tool, Short insertion tool,
conical conn., NP conical conn., SP conical conn., WP
27 31
23
CT-NLI10 CT-SLI10 CT-WLI10
Long insertion tool, Long insertion tool, Long insertion tool,
conical conn., NP conical conn., SP conical conn., WP
20.
3.75
DRILL 1.90mm
A R KING
M
E/ .40mm
SPAD
D R ILL 2
T
PILO
2.40mm
T RY-IN
DY
BO
ILL 3mm
T DR
SP
IS
AD
TW
E/
N 3mm
TRY-I
4
MA
DY
PIL
O
BO
B
RK
OT
ILL
AL DR
.20
DY
FIN
ING
DR
TW
TR
ILL
TW
DRI
B
Y-IN
IST
2.4
IST
OD
LL
DR
2.4
DR
YT
0mm
LL 3
1.90mm
FIN
ILL
R
0mm
Y-IN
mm
AL
3.50m
DRILL
3.5mm
C1 IMPLANT
SPADE / MAR
BODY TRY
PILOT DR
FI NAL
L
RI
L
DR
F I N AL D
-IN
ILL
KING
m
ILL
4
3.3
I N
2.40
2.40
B O DY TRY - m
DRI
4m
mm
mm
L
RIL
LL
0
TWIST D mm
.50
1.9
3
ILL
0m
TWIST DR
mm
m
R I LL3
TWIST D m
0m
2.4
Y-IN
BODY TR 0m
2.4 mm
R ILL .90
PILO T D 1
LL
G DRI
KIN
SPADE / MAR
5
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
ST
NA
AN
RR
DA
WI
OW
DE
RD
1.90 2.40 2.40 3 3 3.50 3.50 4 4
Procedure Tools
Description.
Fin
al
Bo dr
dy ill
Tw try
ist -in
Bo dr 4
ill m
dy 4m m
Tw try m
ist -in , ex
Bo dr 3 ter
dy ill .50 na
3.5 l ir
Tw try 0m m rig
ist -in m m ati
Bo d rill 3m , ex on
dy 3m m ter
Pi try m na
lot -in ,e l ir
dr xte rig
i 2 r ati
Sp ll .40 n al on
ad 2.4 m irr
e 0m m iga
/m m tio
ar n
kin
g
dr
ill
1
.90
m
m
13.
22.
The Dual Stability Mechanism surgery. This differential drilling
method enables moderate
The C1 offers a Dual Stability
compression of the bone at
Mechanism ( DSM ) that
the top 2/3 of the implant body
combines the benefits of
in order to gain mechanical
high primary stability with an
stability, while preventing such
accelerated osseointegration
compression at the apical 1/3.
process, thus minimizing stability
loss during the first weeks after
AL
HANIC STABIL
EC ITY
M
Thanks
Thanks to a to a
unique
unique drilling methodology,
drilling methodology, the implant's
the implant's geometric design
geometric design enables a moderate
enables a moderate compression
compression
of the bone atofthethetop
bone 2/3atofthe
itstop 2/3
body.
ofThis
the body. This compression,
congestion, enabledenabled by a
by a distinctive
distinctive conical
conical shaped
shaped final
nal drill,
drill,
provides
provides an immediate and prolonged
an immediate and
prolonged
mechanical primarymechanical
stability.
primary stability.
The 'compartments' created between
the threads at the apical 1/3 are filled
with blood and bone particles, enabling
rapid bone growth.
ICAL STABI
LOG LIT
IO Y
B
An enhanced
An enhanced secondary
secondary biological stability
biological stability is achieved by
is achieved by integration of the
integration of the implant's geometry,
implant's geometry,
morphology morphology
and a differential and
drilling
a differential drilling approach.
approach. The compartments formed The
compartments
between formed
the implant's threadsbetween the
at the bottom
implant's
1/3 threads
of the cavity at thean
generate bottom 1/3 of
ideal habitat
thesustainable
for cavity, generate
bonean ideal leading
growth habitat
foraccelerated
to sustainable bone growth
osseointegration.
leading to an accelerated
osseointegration.
24.
Stoppers
Four sleeves for each diameter
in 8, 10, 11.5 and 13mm lengths,
color-coded according to drills.
Box
The tray can be removed
from the box for ease of use.
Scale
Teflon IN Insert
Safe.
Safe drilling to desired depth.
Fast.
Clearly arranged depth sleeves for quick and easy identification
of 8-13mm lengths and 3, 3.5mm diameter stoppers.
Following the use of MIS length-
based pilot drills, the C1 Drill Stoppers
Kit enables safe and easy drilling to Drill Stoppers Kit
the exact desired depth. MIS offers Depth Based.
4 different kits in lengths of: 8, 10,
11.5 and 13mm.
Stoppers
Five sleeves 3.0, 3.5, 4, 4.5 and
5mm diameters, color-coded
according to drills.
Box
The tray can be
removed from the box
for ease of use.
13mm
11.5mm
10mm
8mm Desired
drilling depth
Scale
Teflon IN Insert
Fast.
Clearly arranged depth sleeves for quick and easy
identification of 3mm to 5mm diameter drills.
26.
22.
20.
CT-SSR10
CT-SLR10
CT-SSI10 MT-RDL30
CT-SLI10 MT-RDS30
20.
3
1
Outer Tube
Inner Tube
Cover Screw
Final Drill
Implant
12.
www.mis-implants.com
Authorized European Representative:
MIS Germany, Paulinenstrae 12a, 32427 Minden, GERMANY