TEMARIO ORAL:
DIAGNOSTICO INICIAL
GRAD. = DENS. / 10
F1
200 MTS.
F2
200 MTS.
F3
400 MTS.
F4
800 MTS.
F5
A).- PH fondo = (1.38 x200) + (1.4 x 200) + (1.36 x 400) + (1.28 x 800) + (1.5 x 400) = 266 kg/cm2
B).- DLE (1600 mts.) = (10 x 2.06) / 1600 mts. = 1.28 g/cc
C).- DLE (200 mts.) = (10 x 266) / 2000 mts. = 1.33 g/cc
D).- DLE (500 mts.) = (10 x 55 + 13.6) / 500 mts. = 1.38 g/cc
PRUEBA DE GOTEO
DONDE:
DLE = (10 X PRESION ADMOSFERICA)
PROFUNDIDAD ZAPATA + DENSIDAD INICIAL
PRESION
PRESION
ADMOSFERICA
Q ( b -bl )
EJEMPLO: EN UN POZO DONDE CUYA T.R. SEA COLOCADO A 1200 MTS. , SE CORRIO UNA
PRUEBA DE GOTEO DONDE EL LODO TIENE UNA DENSIDAD DE 1.22 g/cc, Y DONDE SE
TABULARON LOS SIGUIENTES DATOS DE LA TABLA, OBTENEMOS LA DENSIDAD
EUIVALENTE QUE NO DEBE SER REBASADA EN EL POZO PARA NO CAUSAR PERDIDA.
PRESION GASTO
GRAFICA
70
65
60
50
40
30
20
10
1 2 3 4 4 4 4
CALCULO DE GRAFICA
E J E R C I C I O
PROBLEMA No 1
PROFUNDADAD
P.H.
CAUSAS DE BROTES
1.MALA PLANEACION DEL POZO. (MAL ASENTAMIENTO DE LA T.R.)
2.NO MANTENER LLENO EL AGUJERO. (CON FACTOR 0.1897)
3.SONDEO DEL POZO AL SACAR TUBERIA.
4.PERDIDA DE CIRCULACION.
5.PESO DEL LODO DEMACIADO BAJO, COMO NORMA TOMAR LA DENSIDAD Y VISCOC.
NOTA: DAR A CONOCER LOS PARAMETROS. EN DONDE LA BURBUJA DE GAS VIAJA A UNA
VELOCIDAD DE 5 KTS. POR MINUTO.
INDICACIONES DE UN REVENTOR
1. AUMENTO EN EL GASTO DE SALIDA.
2. AUMENTO EN EL NIVEL DE PRESAS.
3. AUMENTO EN LA VELOCIDAD DE PERFORACION (QUIEBRE)
4. FLUJO SIN CIRCULACION.
5. CABECEOS DE GAS.
6. DISMINUCION EN LA PRESION DE BOMBEO.
7. EL POZO ACEPTA MENOS LODO O FLUYE MAS LODO QUE EL NORMAL AL EFECTUAR
VIAJES.
8. AUMENTO DE GAS DE CONEXION
9. AUMENTO DE GAS DE VIAJE Y / O DEL GAS DE FONDO
10. LODO CANTAMINADO CON AGUA O AUMENTO DE CLORURO P.P.M.
PROCEDIMIENTOS DE CIERRE
HAY TRES SITUACIONES DE CIERRE IMPORTANTES.
1. LEVANTAR LAFLECHA.
2. SUSPENDER EL BOMBEO Y OBSERVAR SI HAY FLUJO.
3. ABRIR LONEA AL ESTRANGULADOR (VAL. HCR).
4. CERRAR PREVENTOR.
5. CERRAR EL ESTRANGULADOR.
6. ANOTAR PRESION DE CIERRE DE T.P. (PCTP).
7. ANOTAR PRESION DE CIERRE DE T.R. (PCTR).
8. ANOTAR INCREMENTO DE VOLUMEN EN PRESAS.
AL ESTRANGULAR VIAJANDO.
PCR = Pb x 0.27547
DONDE: Pb ES LA PRESION DE BOMBEO
0.27547 FACTOR
SEGUNDO PROBLEMA.
D.C. = (10 X PCTB) / PROF. ENTOCES: (10 X 40) / 3050 + 1.15 g/cc.
D.C. = 1.28 g/cc + 0.04
D.C. final = 1.32 g/cc
HOJA DE TRABAJO.
0 140KG/CM2
100 137 KG/CM2
200 134 KG/CM2
300 131 KG/CM2
400 128 KG/CM2
500 125 KG/CM2
600 121 KG/CM2
700 118 KG/CM2
800 114 KG/CM2
PASOS A SEGUIR PARA CONTROL DE POZOS.
PRESIONES DE CIERRE
TUBERIA DE PERFORACION DE 45 KG/CM2
TUBERIA DE REVESTIMIENTO DE 55 KG/CM2
2.- D.E. = 3.18 ( (DI X Q2) / PTR) ** .25 SI TRABAJAMOS CON 30 EMB./MIN.
D.E. = 3.18 ( (1.05 X(1250) ** 2) / 55) ** 0.25 DE = 3.18( (1.05 X (750)**2/55)**0.25
D.E. = 3.18 ( 1640625 / 55) ** 0.25 DE = 3.18(590625/55)**0.25)
D.E. = 3.18 (29829) ** 0.25 DE = 3.18(10738)**25
D.E. = 3.18 X 13.14 DE = 3.18(10.17)
D.E. = 41.79 DE = 32.34
D.E. =42/64 avos. DE = 32/64 avos,
GASTO DE BOMBA.
3.- Q = 25 LTS. / EMB. X 50 = 1250 LTS./MIN.
4.- VOL e. a. = (D2 - d2) x 0.5067
VOL e. a. = (12.615**2 - 5**2)
VOL e. a, = 134 x0.5067
VOL e. a. = 67.89 Lts./Mts.
VOL. = VOL. 1er. + VOL. 2do. ENTONCES 81468 + 1900.2 =100470 LTS.
EMBOLADAS PRESION
0 75
100 68.6
200 62.2
300 55.8
400 49.4
500 43
556 39
TIEMPO PRESION
0 MINS. 75 KG/CM2
5 MINS. 59 KG/CM2
10 MINS. 43 KG/CM2
11 MINS. 39 KG/CM2
SIMULADOR No 1
P R O B L E M A.
2800 MTS.
200 MTS.
EMBOLADAS PRESION
60.0
100.0 58.5
200.0 57.0
300.0 55.5
400.0 54.0
500.0 52.5
600.0 51.0
700.0 49.5
800.0 48.0
900.0 46.5
1000.0 45.0
1100.0 43.0
1200.0 42.0
1300.0 40.5
1400.0 39.0
1500.0 37.5
1600.0 36.0
1700.0 34.5
1800.0 33.0
1900.0 31.5
2000.0 30.0
2100.0 28.5
TIEMPO Ps
0 60.0
5.0 56.3
10.0 52.5
15.0 48.8
20.0 45.0
25.0 41.3
30.0 37.5
35.0 33.8
40.0 30.0
43.0 27.0
16.- NUMERO TOTAL DE EMBOLADAS (ES LA SUMA DEL 5to. PASO Y EL 12avo. PASO)
1. P.I.C. R - 60 KG/CM2
2. D.E. R - 36/64
3. Q. R -15 LTS./EMB.
4. VOL. e.a. R - 117536 HRS.
5. No DE EMB. R - 7835 EMB,
6. TIEMP. PARA DESALOJAR FLUIDO R - 156 MINS.
7. Ps MAX. T.R. R - 112 KG/CM2
8. Ds CONTROL R - 150 G/CC
9. BARITA NECESARIA R - 3.4 BTO. / MT3
10. PFC R - 27 KG/CM2
11. VOL. T.P. R - 31358 LTS.
12. TIEMPO EN EMB. PARA LLENAR ZAP. R - 2090 EMB. 4180
13. TIEMPO EN MINS. PARA LLENAR ZAP. R - 42 MINS.
14. P. CADA 100 EMB. R - 0.015 - 1.5
15. PROG. CADA CINCO MINUTOS
16. CANTIDAD DE EMBOLADAS R - 9925 EMB. - 19800 EMB.
17. TIEMPO R - 3.3 HRS.
P R O C E D I M I E N T O D E C I E R R E .
SUSPENDER OPERACION.
SUSPENDER BOMBEO.
OBSERVER POZO.
MANTENER AIRE AL SISTEMA.
ABRIR VALVULAS HIDRAULICAS.
CERRAR EL PREVENTOR.
CERRAR EL ESTRANGULADOR.
EVALUAR LA SITUACION .
DETERMINAR Ps EN T.P. Y T.R..
ASI COMO EL AUMENTO DE VOLUMEN EN LAS PRESAS.
P R O B L E M A No 3
77445 LTS.
1250 MTS.
5.- NUMERO DE EMBOLADAS PARA DESALOJAR FLUIDOS INVASORES (E.A.)
EMBOLADAS PRESION
0 58
100 55.3
200 52.6
300 49.9
400 47.2
503 44.5
TIEMPO EMBOLADAS
0 58
5 48.5
7 44.7
T = 7.1 + 51 = 58 MINUTOS
T = .96 HRS.
R E S PU E STAS
1. P.I.C. R - 58 KG/CM2
2. D.E. R - 53/64 avos.
3. Q. BOMBA . R - 1512 - 21.6
4. VOL. e.a. EN LITROS.
5. No DE EMBOLADAS PARA DESALOJAR FLUIDO INVASOR.
6. TIEMPO EN MINUTOS PARA DESALOJAR FLUIDO INVASOR.
7. PRESION MAXIMA EN T.R.
8. DENSIDAD DE CONTROL.
9. BARITA NECESARIA EN TONELADAS.
10. PRESION FINAL DE CIRCULACION .
11. VOLUMEN PARA LLENAR LA ZAPATA EN LITROS.
12. NUMERO DE EMBOLADAS PARA LLENAR LA ZAPATA.
13. TIEMPO EN MINUTOS PARA LLENAR ZAPATA .
14. PROGRAMA DE PRESION DE BOMBEO CON 100 EMBOLADAS.
15. PROGRAMA DE PRESION DE BOMBEO CON CINCO MINUTOS.
16. NUMERO DE EMBOLADAS.
17. TIEMPO DEL CICLO EN HORAS.
P R O B L E M A No 4
P R O B L E M A
EMBOLADAS. PRESION.
0 70 P.I.
100 66.1
200 2.2
300 58.3
306 57 P.F.
TIEMPO PRESION
0 70
5 64.3
7 57