Note: Gen2 Regen up to 2000kg is officially sales release on April 1st 2010 and Gen2
sales phase out at the same time
Configuration Upgrade
GeN2 GeN2-Regen
ABA20220AS ABA20220BD
Apply to 1150kg to 2000kg Gen2 Regen only
GeN2-Regen
GeN2
&Previous Gen2 Regen up to 1000kg
GeN2 GeN2-Regen
&Previous Gen2 Regen up to 1000kg
GeN2
& Previous Gen2 Regen up to 1000kg
GeN2-Regen
GeN2 GeN2-Regen
&Previous Gen2 Regen up to 1000kg
GeN2-Regen
GeN2
STD:9672D/E
STD:HN6000B/C Apply to 1150kg to 2000kg only
00kg
GeN2(OH-CON4424 Controller) g~20
30k
6
GeN2 GeN2-Regen
Apply to 630kg to 2000kg Gen2 Regen
Top floor
Gen2-Regen
GeN2
Note: MRO function is standard. ARO function should be offered as an optional function after June 2010.
Performance
Parameter Target
350 @ 1.0m/s
Min. Floor Distance (mm)
500 @ 1.5m/s ~1.75m/s
Max Floor Distance (m) 11
Maximum Acceleration (PMT measurement: m/s2) <1.2
Maximum Jerk (PMT measurement: m/s3) 1.0
150@1.0m/s
Maximum Starts Per Hour 180@ 1.5m/s ~1.75m/s,
40% duty cycle
Speed Tolerance (%) 5
Stopping Accuracy (mm) Typical/Maximum 3/ 5
Max In Car Noise (dB), Fan Off 52
Noise at Top landing with door closed. (dB) Average 52
A95,11
Max Vertical Vibrations (mg) @ normal speed
PK-PK,14
System Requirement
Power Supply
Max Elevation:
1000m: full performance
2000m: Reduced performance(1% of rated running current per 100m)
Operating Humidity
95% non-condensing