Você está na página 1de 2

Escuela Politecnica Nacional

Diseo de separador trifasico


Raymi Campo

QL = 10000 BPD QO = 7000


BSW = 30% QW = 3000
GOR = 300 SCF/Bl O = 0.8762
P= 60 PSI tr.W = 10
tg = 5 min tr.O = 10
g = 1 g = 0.2893
T= 560 R O = 54.672
z= 1
Cd = 0.34
dm = 100
API = 30 O = 0.8762
O = 54.672
CAPACIDAD MANEJO DE GAS CAPACIDAD MANEJO DE LQUIDO

Leff*d = 35.0087 Leff*d2 = 142857.14286

Dimetro (in) Leff (ft) Ls/s (ft) Dimetro (in) Leff (ft)

6 5.835 6.33 6 3968.254


12 2.917 3.92 12 992.063
18 1.945 3.44 18 440.917
24 1.459 3.46 24 248.016
30 1.167 3.67 30 158.730
36 0.972 3.97 36 110.229
42 0.834 4.33 42 80.985
48 0.729 4.73 48 62.004
54 0.648 5.15 54 48.991
60 0.583 5.58 60 39.683
66 0.530 6.03 66 32.795
72 0.486 6.49 72 27.557
78 0.449 6.95 78 23.481
84 0.417 7.42 84 20.246
90 0.389 7.89 90 17.637
96 0.365 8.36 96 15.501
102 0.343 8.84 102 13.731

Recipiente ptimo 84" x 27'


BPD
BPD o = 10 cp
w = 1 cp
min
min
lb/ft3
lb/ft3

lb/ft3
IDAD MANEJO DE LQUIDO

Ls/s (ft) 12Ls/s /d

5291.01 10582.01
1322.75 1322.75
587.89 391.93
330.69 165.34
211.64 84.66
146.97 48.99
107.98 30.85
82.67 20.67
65.32 14.52
52.91 10.58
43.73 7.95
36.74 6.12
31.31 4.82
26.99 3.86
23.52 3.14
20.67 2.58
18.31 2.15

Você também pode gostar