Você está na página 1de 3

Doc. No. Rev.

Date
D104531-REF 3.06 2011-01-19
Damm Cellular Systems A/S, Denmark TMD412 TMA/TMD Tower Mounted Duplexer

1.1 TMD412 TMA/TMD TOWER MOUNTED DUPLEXER

Description
The TMD412 is a combined Tower Mounted Duplexer and RX Amplifier to be used with the
BS41x Base Stations.

The TMD412 contains two RX Amplifiers and a Duplex Filter, which can be used to combine
the TX Antenna feeder and one of the RX connections to a single antenna. The use of the
Duplex Filter option is provided by an external removable jumper.

The RX Amplifier part of the TMD412 is a mandatory part of the BS41x and shall normally be
tower mounted close to the antennas. When tower mounted make sure that the plate with the
sockets is positioned downwards. If tower mounting is not possible, it can be ground mounted
at the BS location.

The Amplifier part of the TMA412 contains two double directional couplers for the RFTL test
feature, two low-loss highly selective input filters and two low-noise high dynamic range
amplifiers built with PHEMT transistors. DC feed and RFTL direction control is provided from
the AI411 Antenna Interface Unit in the BS. The two RX antenna connections are galvanic
grounded in the filter for lightening protection. The three BS feeder connections with DC are
provided with lightening arrestors for protection.

The Duplexer Part of the TMD412 is optimised for low loss and extremely low inter-
modulation distortion.

N:\Doc\10xxxx\1045xx\104531\D104531-REF.doc Page 1 of 3
Doc. No. Rev. Date
D104531-REF 3.06 2011-01-19
Damm Cellular Systems A/S, Denmark TMD412 TMA/TMD Tower Mounted Duplexer

The TMD412 is sealed for IP65 encapsulation. Due to the sealing being completely airtight,
a pressure equalizing valve is inserted to ensure pressure compensation with temperature
change.

The TMD412 is provided with a flexible mounting plate, which can be either wall- or mast-
mounted. For mast up to 50mm diameter and normal weather conditions, the normal
delivered fixtures can be used. For thicker masts and extreme weather conditions, e.g. in
arctic areas with icing and heavy wind loads, creation of special rugged mounting fixtures for
the mounting plate is recommended. More information can be seen in the Application note
Antenna system for BS41x.

The TMD412 is as standard factory tested in the standard BS temperature range 20 to +55
Celsius. Optionally it is also available in an extended temperature version tested for
-55 to +70 Celsius.

Note, that when using the duplex filter option, care shall be taken not to use TX frequencies
generating 5th order IM products on the used RX frequencies.

Specification
Parameter Value
Frequency:
Range See ordering information
Bandwidth See ordering information

RX Amplifier:
Gain +15dB nom.
Noise figure 2.0dB typ.
3rd-order IM input intercept point +16dBm typ.
Selectivity in TX band 60dB min.
Input return loss 14dB min.
Amplifier supply voltages +12V from AI411
Test control voltage +/-8V from AI411
Connectors (x5) N female

Duplexer:
TX path insertion loss (10MHz duplex spacing) 0.6dB typ.
RX path insertion loss (10MHz duplex spacing) 0.8dB typ.
TX/RX path attenuation in RX/TX frequency bands 30dB min.
Maximum TX input power 8x10W Tetra
Inter-modulation at max. TX power -130dBm max.
TX and Antenna connectors DIN 7/16 female
RX connector N female

Physical:
Dimensions (W x D x H, excl. connectors) 245x130x337mm
Weight (incl. Mounting accessories) 8.9kg
Wind area 0.1sq.m
Storage temperature range -55 to +70 Celsius
Operating temperature range -25 to +55 Celsius
Optional temperature range -55 to +70 Celsius
Encapsulation IP65

N:\Doc\10xxxx\1045xx\104531\D104531-REF.doc Page 2 of 3
Doc. No. Rev. Date
D104531-REF 3.06 2011-01-19
Damm Cellular Systems A/S, Denmark TMD412 TMA/TMD Tower Mounted Duplexer

Ordering
Note: Actual 5MHz/14MHz Bandwidth shall be stated at order

Item number Description


104531 TMD412 TMA/TMD 380-390/390-400MHz, 5MHz BW
104532 TMD412 TMA/TMD 410-420/420-430MHz, 5MHz BW
104533 TMD412 TMA/TMD 450-460/460-470MHz, 5MHz BW
104535 TMD412 TMA/TMD 350-360/360-370MHz, 5MHz BW
104536 TMD412 TMA/TMD 300-310/336-346MHz, 10MHz BW
104538 TMD412 TMA/TMD 805-825/850-870MHz, RX-14MHz TX-20MHz BW
104591 TMD412 TMA/TMD Ext. temp. test

N:\Doc\10xxxx\1045xx\104531\D104531-REF.doc Page 3 of 3