Você está na página 1de 11

Project 1

Partner for Contact:


Order No.:
Company:
Customer No.:

Date: 01.06.2017
Operator:
Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

GE Lighting - EURO-2 HPS 70W Pos 5B / Luminaire Data Sheet

Luminous emittance 1:

See our luminaire catalog for an image of the


luminaire.

Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table
CIE flux code: 41 76 98 100 79 can be displayed for this luminaire.

DIALux 4.13 by DIAL GmbH Page 2


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

GE LIGHTING SLBT/1/F/E/72/40/ SLBT LED 72W 4000K / Luminaire Data Sheet

Luminous emittance 1:

See our luminaire catalog for an image of the


luminaire.

Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table
CIE flux code: 42 75 96 100 100 can be displayed for this luminaire.

DIALux 4.13 by DIAL GmbH Page 3


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Planning data

Street Profile

Roadway 1 (Width: 6.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)

Maintenance factor: 0.67


Luminaire Arrangements

Luminaire: GE Lighting - EURO-2 HPS 70W Pos 5B


Luminous flux (Luminaire): 5202 lm Maximum luminous intensities
Luminous flux (Lamps): 6600 lm at 70: 360 cd/klm
Luminaire Wattage: 84.0 W at 80: 23 cd/klm
Arrangement: Single row, bottom at 90: 0.60 cd/klm
Pole Distance: 30.000 m Any direction forming the specified angle from the downward vertical, with the
Mounting Height (1): 5.000 m luminaire installed for use.
Height: 4.795 m Arrangement complies with luminous intensity class G3.
Overhang (2): 0.000 m Arrangement complies with glare index class D.6.
Boom Angle (3): 0.0
Boom Length (4): 0.000 m

DIALux 4.13 by DIAL GmbH Page 4


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Photometric Results

Maintenance factor: 0.67 Scale 1:258

Calculation Field List

1 Valuation Field Roadway 1


Length: 30.000 m, Width: 6.000 m
Grid: 17 x 10 Points
Accompanying Street Elements: Roadway 1.
Selected Lighting Class: CE3 (Not all lighting performance requirements are met.)
Additional EV Lighting Class: EV5 (Not all lighting performance requirements are met.)

Eav [lx] U0 Emin (vertical) [lx]


Calculated values: 11.69 0.08 0.03
Required values according to class: 15.00 0.40 5.00
Fulfilled/Not fulfilled:

DIALux 4.13 by DIAL GmbH Page 5


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Results overview

Maintenance factor: 0.67 Scale 1:258

Grid: 17 x 10 Points
Accompanying Street Elements: Roadway 1.
Selected Lighting Class: CE3 (Not all lighting performance requirements are met.)
Additional EV Lighting Class: EV5 (Not all lighting performance requirements are met.)

Eav [lx] U0 Emin (vertical) [lx]


Calculated values: 11.69 0.08 0.03
Required values according to class: 15.00 0.40 5.00
Fulfilled/Not fulfilled:

DIALux 4.13 by DIAL GmbH Page 6


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Isolines (E)

Values in Lux, Scale 1 : 258

Grid: 17 x 10 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
12 0.99 46 0.085 0.021

DIALux 4.13 by DIAL GmbH Page 7


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Greyscale (E)

Scale 1 : 258

Grid: 17 x 10 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
12 0.99 46 0.085 0.021

DIALux 4.13 by DIAL GmbH Page 8


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Value Chart (E)

Values in Lux, Scale 1 : 258


Not all calculated values could be displayed.

Grid: 17 x 10 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
12 0.99 46 0.085 0.021

DIALux 4.13 by DIAL GmbH Page 9


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Table (E)

5.700 3.05 3.59 3.33 2.25 1.65 1.30 1.11 1.06 0.99 1.06
5.100 4.35 4.79 4.32 2.83 2.05 1.67 1.43 1.27 1.13 1.27
4.500 6.86 6.69 6.07 3.81 2.77 2.34 2.07 1.51 1.33 1.51
3.900 15 11 9.83 6.17 4.68 4.47 3.00 1.90 1.54 1.90
3.300 27 18 16 10 8.64 7.08 4.39 2.29 1.79 2.29
2.700 39 26 22 17 14 10 5.48 2.65 2.03 2.65
2.100 42 30 26 23 18 11 6.24 2.99 2.24 2.99
1.500 46 33 26 25 18 12 6.54 3.27 2.42 3.27
0.900 44 33 23 23 17 10 6.31 3.34 2.49 3.34
0.300 42 29 18 18 14 8.03 5.49 3.18 2.49 3.18
m 0.882 2.647 4.412 6.176 7.941 9.706 11.471 13.235 15.000 16.765
Attention: The coordinates refer to the image above. Values in Lux.

Grid: 17 x 10 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


12 0.99 46 0.085 0.021

DIALux 4.13 by DIAL GmbH Page 10


Project 1
01.06.2017

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Table (E)

5.700 1.11 1.30 1.65 2.25 3.33 3.59 3.05


5.100 1.43 1.67 2.05 2.83 4.32 4.79 4.35
4.500 2.07 2.34 2.77 3.81 6.07 6.69 6.86
3.900 3.00 4.47 4.68 6.17 9.83 11 15
3.300 4.39 7.08 8.64 10 16 18 27
2.700 5.48 10 14 17 22 26 39
2.100 6.24 11 18 23 26 30 42
1.500 6.54 12 18 25 26 33 46
0.900 6.31 10 17 23 23 33 44
0.300 5.49 8.03 14 18 18 29 42
m 18.529 20.294 22.059 23.824 25.588 27.353 29.118
Attention: The coordinates refer to the image above. Values in Lux.

Grid: 17 x 10 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


12 0.99 46 0.085 0.021

DIALux 4.13 by DIAL GmbH Page 11

Você também pode gostar