Você está na página 1de 6

Fx(kN)

4000 4000

3000 3000

2000 2000

1 2
1 2 3

-2000 -2000

-4000 -4000

Member 1, Fx, E1: LOAD

Mz(kNm)
150 150

100 100

50 50

1 2
1 2 3

-50 -50

-100 -100
-100 -100

-150 -150

Member 1, Mz, E1: LOAD


My(kNm)
100 100

75 75

50 50

1 2
1 2 3

-50 -50

-100 -100

Member 1, My, E1: LOAD

Job Information

Engineer Checked Approved

Name:
Date: 17-Mar-17

Structure Type SPACE FRAME

Number of Nodes 2 Highest Node 2


Number of Elements 1 Highest Element 1
Number of Plates 0 Highest Plate 0

Number of Design Groups 1


Number of Design Slabs 0
Number of Load Cases 1
Number of Design Briefs 1

Included in this printout are data for:

Design Group Design Brief Design Code Members

G1: Design Group 1 B1: DES PARA IS456 Column M1

Design Group Summary - Design Group 1

Member Design Type Main Bars


Major Minor
M1 Initial Column Ok Ok
Column Input Data

Eff. Length Factors Braced


Length Cover Link
Member Type Major Minor Major Minor
(m) (cm) Size

M1 Column 3.000 1.00 1.00 Yes Yes 4.0 8

Column Main Reinforcement

Axial Major Minor Design As Req. Total As P


Member L/C
(kN) (kNm) (kNm) Axis (mm2) Bars (mm

M1 L1 3000.000 100.000 75.000 Biaxl min 5890 12T25

Members

Node Node Emt Length O. Length


Member Element Property
A B (m) (m)

M1 1 1 2 349 x 600 3.000 3.000

Member 1 - Scheduled Bars

Bar Type and No. of Bar Length Shape A B C D E/R

Mark size bars (mm) code (mm) (mm) (mm) (mm) (mm)

01 T25 12 3000 00
02 R8 10 1700 51 520 270
03 R8 10 1000 51 175 270
04 R8 20 775 13 125 520 50
Member 1 - Detailed IS456 Design Requirements

Design of Column is done as per IS:456-2000

Section Property: 349 x 600

Storey height = 3.000 m

Rectangular section: Width = 350 mmDepth = 600 mm

Cover = 40 mm

Member 1 - Detailed IS456 Main Reinforcement

Unsupported Length of column = 3.00 m

Slenderness checks:

Effective length Major, lex = 3.000 m

Effective length Minor, ley = 3.000 m

Slenderness ratio Major, (lex/H) = 5.000

Slenderness ratio Minor, (ley/B) = 8.571

Slenderness Limit = 12.000

NOT SLENDER

Critical Loadcase: LOADCASE 1

Axial Load P, = 3000.00 kN

Major M, End 1, = -100.00 kNm

End 2, = -100.00 kNm

Minor M, End 1, = 75.00 kNm

End 2, = 75.00 kNm

Minimum eccentricity about major axis = 26.00 mm

Minimum eccentricity about minor axis = 20.00 mm

Moment Due to Min Ecc Major = 78.00 kNm

Moment Due to Min Ecc Minor = 60.00 kNm

Min. Eccentricity moment about major axis ignored as per Cl 39.3

Design Moment Major = 100.00 kNm


Design Moment Minor = 75.00 kNm

Steel area required = 5890mm2 (12 No. 25 dia. bars)

Total steel area provided = 5890mm2

Pure Axial Capacity Pu =4129.646 KN

Axial Capacity Ratio P/Pu =0.726

Axial Capacity Axial Load OK for axial resistance

Major Axis Capacity Mux1 =275.351 KNm

Major Axis Capacity Ratio Mux / Mux1 =0.363

Major Axis Capacity Major Axis Moment OK for moment resistance

Minor Axis Capacity Muy1 =140.952 KNm

Minor Axis Capacity Ratio Muy / Muy1 =0.532

Minor Axis Capacity Minor Axis Moment OK for moment resistance

Biaxial Interaction equation = [(Mx/Mux1)]an + [(My/Muy1)]an1,0 Cl. 39.6

where exponent, n = 1.877

Biaxial Interaction equation = [(100.00/275.35)]1.88 + [(75.00/140.95)]1.88 = 0.73

Biaxial Interaction Result 1.0 OK for biaxial resistance

Member 1 - IS456 Transverse Reinforcement

Diameter of lateral ties = 8 mm

Spacing of lateral ties = 300 mm

List of Design Groups - BIAXAIL COLUMN DESIGN

Design Group Brief

G1 Design Group 1 DES PARA

List of Design Briefs - BIAXAIL COLUMN DESIGN

Brief Code
1 DES PARA IS456 Column

Brief Detail:

There is no data of this type.

Você também pode gostar