Easergy range
Panorama
2010
Easergy range Panorama
Easergy: a range of solutions for MV network management
Easergy range dedicated Overhead switch Control unit for MV and MV/LV Communicating fault Communicating fault
remote control system control unit substations current detector for current detector for an
overhead lines MV substation
Capacity: Control of 1 or 2 Control of 1 to 16 Control of 4 Single-phase ammetric Three-phase, 2 channel
500 Easergy type devices switches switches switches detector fault current detector open
to all types of earthing
system
Main functions
b Network view with substation b Pole mounted b Wall-mounted b Ringmastermounted Flite 116: b Wall-mounted
alarm b Switch monitoring and control b Line installation b Phase-to-phase and
b Detailed substation view b Fault current detector b Phase-to-phase and phase-to-earth fault current
b Alarm logs, archives b Automation systems: sectionaliser, phase-to-earth fault current detection
b Direct access to substation power supply source changeover switch detection b U, I, P, Q, S, energy and
view via a list b Measurements: I, U, b Measurements: I, U b I and U presence power
b Automatic sorting of alarms P, Q, S, energy and measurements factor measurements cos
and archives by substation power factor cos j b Communication b Management of 3 digital
b Online help management with G200 outputs and 6 digital inputs
b Concentration of Modbus communication devices b Powered by lithium battery b 220 Vac supply backed-
b Data and measurements archives G200: up by Ni-CD battery
b Back-up power supply for control unit, b Pole-mounted b Concentration of Modbus
switch and transmission equipment b Flite 116 concentrator communication devices
b Processing and archiving b Data and measurements
b Free I/O: 3 digital outputs archives
and 6digital inputs
b 220 Vac, solar or 12 Vdc
supply
Communication
b Integrated communication b 1 to 2 serial communication ports b 915 MHz short range radio b 1 communication port
front-end b 1 Ethernet port communication b 1 Ethernet port (option)
b Permanent and non- b Communication port operation b 1 SCADA communication b Transmission interface:
permanent communications management port PSTN, Radio, GSM, GPRS,
management: b Transmission interface: PSTN, radio, GSM, GPRS, Ethernet, b Transmission interface: Ethernet, RS232, RS485
v telephone/GSM dedicated line, RS232, RS485 radio, GSM, GPRS, CDMA
v radio
v direct public and dedicated
private line
b Periodic call management
Communication protocol
b Modbus b IEC 870-5-101 and IEC 870-5-104 b IEC 870-5-101 b IEC 870-5-101
b Serial DNP3 and TCP/IP b Serial DNP3 and TCP/IP b DNP3
b Serial Modbus and TCP/IP b Modbus b Modbus
b Other proprietary protocols
Data configuration
b Professional communications b
Embedded web server b Local and remote b Local or remote
and database editor b
Local and remote configuration configuration with Easergy configuration
b Data creation via dialogue L500 b Embedded web server
boxes
Accessories
b Radio, PSTN, DL and b Simulation tools and tests b Installation tool b Open phase and zero
fibre optic modems sequence sensors
b Open phase
and zero
sequence sensors
Local fault
indication
Flite 110-SA Flite 210, 230 Flite 312, 315, 332, Flair 21D, 22D, 23DV Flair 219, 279 Flair 310, 370
335, 382
Fault current detectors for an overhead network Fault current detectors for MV substations
Single-phase ammetric Three-phase ammetric Three-phase directional DIN format three-phase Three-phase ammetric Three-phase directional
detector detectors detectors ammetric detectors detectors detectors
Main functions
b Line installation b Pole-mounted b Pole-mounted b Incorporated in the b Wall-mounted b Wall-mounted
switchgear
b Phase-to-phase and b Phase-to-phase and b Phase-to-phase and b Phase-to-phase and b
Phase-to-phase and b Phase-to-phase and
phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault
current detection current detection current detection current detection current detection current detection
b Indication of transient b Indication of transient b Transient and/or b Measurements: b Indication of transient
and permanent faults and permanent faults permanent fault indicator v ammeter and permanent faults
b Fault counter v maximeter
Communication
b
Option: signalling b
Signalling contacts b
Signalling contact for b
Signalling contact b
Signalling contact
contact for RTU for RTU RTU for RTU for RTU
Data configuration
b By micro-switches b By micro-switches b Configurable via b By micro-switches b By micro-switches b Configurable via
display unit or button and display unit display unit
Accessories
b Installation tool b Open phase and zero b Open phase and zero b Open phase and zero
sequence sensors sequence sensors sequence sensors
b Unit for wall-mounting
What are the expected advantages
of MV network management?
b Develop customer satisfaction
and services
b Increase economic performance
b Control investment (past and future)
Schneider Electric As standards, specifications and designs change from time to time, please ask for confirmation
35 Rue Joseph Monier of the information given in this publication.
CS 30323
92506 Rueil Malmaison Cedex This document has been printed
Tel : +33 (0)1 41 29 70 00 on ecological paper
Fax : +33 (0)1 41 29 71 00
Publishing: Schneider Electric Industries SAS
www.schneider-electric.com Design: Schneider Electric Industries SAS
Printing: Imprimerie du Pont de Claix/JPF - Made in France
AMTED107018EN 01-2010